Grizzly Industrial H6441 Halogen Lamp Instruction Manual

June 17, 2024
Grizzly Industrial

grizzly-logo

Grizzly Industrial H6441 Halogen Lamp

Specifications

  • Power Requirements: Grounded 110V
  • Transformer: 24V
  • Halogen Bulb (H6440): 70 Watt
  • Halogen Bulb (H6441): 50 Watt

Inventory

Model H6440:

  • 1. PH6440001 – POWER CORD & TRANSFORMER ASSY
  • 2. PH6440002 – MOUNTING BASE
  • 3. PH6440003 – SUPPORTING ARM ASSEMBLY
  • 4. PH6440004 – LAMP HOUSING ASSEMBLY
  • 5. PH6440005 – SWITCH ASSEMBLY
  • 6. H3250 – HALOGEN BULB ASSY 70 WATT

Model H6441:

  • 1. PH6441001 – POWER CORD & TRANSFORMER ASSY
  • 2. PH6441002 – MOUNTING BASE
  • 3. PH6441003 – SUPPORTING ARM ASSEMBLY
  • 4. PH6441004 – LAMP HOUSING ASSEMBLY
  • 5. PH6441005 – SWITCH ASSEMBLY
  • 6. H3252 – HALOGEN BULB ASSY 50 WATT

Product Usage Instructions

Power Connection
Only connect this lamp to a properly grounded 110V power source

Mounting and Safety
Halogen lamps can become very hot. Securely mount this lamp to a stable surface that is safely away from combustible materials of any kind. Never place combustible materials, such as cloth or paper items, volatile liquids, or explosive gases, etc., near the lamp at any time.

Bulb Replacement
DO NOT replace the halogen bulb with a wattage higher than what this lamp is rated for.

  1. Turn the lamp OFF, unplug it from the power source, then allow it to cool.
  2. Remove the six flat head screws from the cover plate on the back of the lamp housing.
  3. Carefully remove the back cover, rubber gasket, and the retaining plate from the lamp housing.
  4. Identify the bulb assembly connection and retaining cap inside the lamp housing.
  5. To remove the retaining cap and bulb assembly from the reflective cone, push the cap down as you twist it counterclockwise.
  6. Slide the insulation sleeve surrounding the bulb assembly connection down the wire, then carefully pull the connection apart.
  7. Re-connect the new bulb assembly, slide the insulation over the connection area, then reinstall the parts in the reverse order they were removed.

Safety Precautions

  • To avoid electrical fires or electrocution, DO NOT allow any liquid to come in contact with the lamp.
  • To avoid burns or electrocution, turn the lamp OFF, unplug it from the power source, and allow it to cool before making adjustments or performing maintenance.
  • Children or pets are unaware of the hazards of a hot halogen lamp. DO NOT allow children or pets near the lamp.
  • To avoid burns or fire, never handle the hot lamp or discard a hot halogen bulb.
  • For safe operation, never operate this lamp with missing or broken parts.

FAQ

Q: Can I use a higher-wattage bulb than specified?
A: No, DO NOT replace the halogen bulb with a wattage higher than what this lamp is rated for.

Q: Can I touch the lamp or bulb when it’s hot?
A: No, to avoid burns or fire, never handle the hot lamp or discard a hot halogen bulb.

Q: Can children or pets be near the lamp?
A: No, children or pets are unaware of the hazards of a hot halogen lamp. DO NOT allow children or pets near the lamp.

WARNING

  1. Only connect this lamp to a properly grounded 110V power source.
  2. Halogen lamps can become very hot. Securely mount this lamp to a stable surface that is safely away from combustible materials of any kind. Never place combustible materials, such as cloth or paper items, volatile liquids, or explosive gases, etc., near the lamp at any time.
  3. DO NOT replace the halogen bulb with a wattage higher than what this lamp is rated for.
  4. To avoid electrical fires or electrocution, DO NOT allow any liquid to come in contact with the lamp.
  5. To avoid burns or electrocution, turn the lamp OFF, unplug it from the power source, and allow it to cool before making adjustments or performing maintenance.
  6. Children or pets are unaware of the hazards of a hot halogen lamp. DO NOT allow children or pets near the lamp.
  7. To avoid burns or fire, never handle the hot lamp or discard a hot halogen bulb.
  8. F or safe operation, never operate this lamp with missing or broken parts.

Specifications

  • Power Requirements………………. Grounded 110V
  • Transformer……………………………………………. 24V
  • Halogen Bulb (H6440)…………………………70 Watt
  • Halogen Bulb (H6441)…………………………50 Watt

Inventory

Figure 1. Inventory and identification (Model H6440 shown).

REF PART # DESCRIPTION
Model H6440

Model H6441

Copyright © SEPT EMBER, 2008 By Grizzly Industrial, Inc.

WARNING : NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL, INC. #TS11149 PRINTED IN CHINA

Replacing Bulb

  1. Turn the lamp OFF, unplug it from the power source, then allow it to cool.
  2. Remove the six flat head screws from the cover plate on the back of the lamp housing, as shown in Figure 2. Figure 2. The back cover plate was removed from the lamp housing.
  3. Carefully remove the back cover, rubber gasket, and the retaining plate from the lamp housing.
  4. Identify the bulb assembly connection and retaining cap inside the lamp housing, as shown in Figure 3. Figure 3. Bulb assembly connection and retaining cap.
  5. To remove the retaining cap and bulb assembly from the reflective cone, push the cap down as you twist it counterclockwise. Note: Notice how the compression spring is mounted on the inside flanges of the retaining cap.
  6. Slide the insulation sleeve surrounding the bulb assembly connection down the wire, then carefully pull the connection apart, as shown in Figure 4. Figure 4. The bulb assembly and retaining cap were removed from the lamp housing
  7. Re-connect the new bulb assembly, slide the insulation over the connection area, and then reinstall the parts in the reverse order they were removed.

WARNING
Like all high-intensity lamps, there is a potential danger when operating this lamp. Accidents are frequently caused by a lack of familiarity or failure to pay attention. Use this lamp with respect and caution to decrease the risk of operator injury. If normal safety precautions are overlooked or ignored, serious personal injury may occur.

If you need help with your new halogen lamp, call our Tech Support at 570-546-9663.