Sunco MWP15 LED Full Cutoff Wall Pack Installation Guide
- June 17, 2024
- SUNCO
Table of Contents
LED WALL PACK
Installation Guide
MWP15 LED Full Cutoff Wall Pack
WARNING
READ ALL INSTRUCTIONS BEFORE ATTEMPTING INSTALLATION
- To avoid electric shock, disconnect power at source prior to installation.
- The installation should be performed by qualified electricians or lighting technicians.
- Before conducting any installation, maintenance, or removal, disable all power to the luminaries and wait until the fixture cool down.
- Do not touch the fixture while it is in service.
- If there is any problem with the fixture, DO turn off power and DO NOT attempt repair unless you are a qualified technician or the customer service member.
- This luminaire is designed to operate in ambient temperatures ranging from -40°F to 104°F and to be horizontally mounted with the LEDs facing down.
- This product is not available for several special environments, such as places with corrosive gas liquids or high pressure water vapor.
Junction Box Mounting
-
Loosen screws and remove the front case set carefully from the back plate.
(Angle between front case and back plate varies from O degree to 45 degree. Push up to take down the front case.) -
Knuckle out the1 /2″ hole in center (B) for wiring, the fixture supports standard 3 1 /4″ and 4″ junction box.
-
Attach the back plate on the wall, use the supplied gaskets for a weather tight seal.
-
Finish wiring (Black for Line, White for Neutral and Yellow Green for Ground).
-
Replace the lens set on the hinges, make connections and close the lens set then tighten the screws.
-
CCT Regulator adopted, make sure that red wire for V-plus, black for VH, and blue for VL.
-
When the sensor is configured, the sensor is tightened by assembling as shown below
( Note: When the fixture is equipped with both sensor and CCT controller, the sensor’s operation is only adjusted according to the maximum power of the fixture.
A – 1/2″ NPS tapped holes
(surface conduit or photo control)
B – 1/2″ Nps Tapped Holes
C – 5/16″ dia. Screw hole
Conduit Mounting
-
Loosen screws and remove the front case set carefully from the back plate.
(Angle between front case and back plate varies from O degree to 45 degree. Push up to take down the front case.) -
Knuckle out the 1/2″hole in sides of the fixture (Or remove the 1/2″plug in the top of fixture) where you intend to feed conduit.
-
Drilling out the holes (C) to secure it on the wall with choosing proper screws.
-
Finish wiring (Black for Line, White for Neutral and Yellow Green for Ground).
-
Replace the lens set on the hinges, make connections and close the lens set then tighten the screws.
-
CCT Regulator adopted,make sure that red wire for V-plus, black for VH, and blue for VL.
-
When the sensor is configured, the sensor is tightened by assembling as shown below
( Note: When the fixture is equipped with both sensor and CCT controller, the sensor’s operation is only adjusted according to the maximum power of the fixture.
Note: To ensure waterproof seal, apply weatherproof silicone sealant between the mounting surface and mounting box, as well as around the sides of the housing. This is especially important with an uneven wall surface. Silicone all plugs and unused conduit entries.
Power and CCT Selectable Version
- Loosen the two PM5*15 screws on the side of the fixture, open the front cover of the housing, and adjust the DIP switch to the corresponding color temperature and power in the actual application requirements. Instructions are as follows:
- Make sure that all wires are securely connected and that there are no exposed conductors. Cover the fixture, (make sure wires do not get pinched) then tighten the screws.
Caution: All electrical work must conform to the National Electric Code (NEC) and all applicable local codes and ordinances.
PHOTOCELL INSTALLATION
Universal voltage driver permits operation at 60 Hz except fixtures factory ordered with a 120-277VAC (PO)
- Install photocell and wire as per diagram.
- Use photocell rated for your supply voltage.
TROUBLESHOOTING
-
Check that the line voltage at the fixture is correct.
Refer to wiring directions. -
Is the fixture grounded properly.
WIRING DIAGRAM
For 0-10V dimming version, please check wiring diagram below.