POWER MISER TM6
GAS WATER HEATER
FOR POTABLE WATER HEATING ONLY,
NOT SUITABLE FOR SPACE HEATING
NOT FOR USE IN MOBILE HOMES.
153.336160 Power Miser TM6 Gas Water Heater
MODEL NO.
153.336160
153.336260
153.336300 HA
153.336360
153.336400 HA
153.336464
153.336500 HA
153.336560
153.336760
153.336800 HA
153.336860
153.336900 HA
153.336960| 30 Gallon Short
40 Gallon Short
30 Gallon High Altitude
30 Gallon
40 Gallon High Altitude
40 Gallon
50 Gallon High Altitude
50 Gallon
30 Gallon Propane (LP.)
40 Gallon Propane (L.P.) High Altitude
40 Gallon Propane (LP.)
50 Gallon Propane (L.P.) High Altitude
50 Gallon Propane (LP.)
---|---
C3 Technology ™ Gas Water Heaters meet the new ANSI Z21,10,1 standard that deals with the accidental or unintended ignition of flammable vapors, such as those emitted by gasoline.
Read and understand instruction manuai and safety messages before installing,
operating or servicing this water heater
Failure to fallow instructionsand safety messages could result in death or
serious injury Instruction manua! must remain with water heater
For Your Safety
AN ODORANT ISADDEDTOTHE GASUSED BYTHIS WATER HEATER
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
-Do not store or use gasoJine or other flammable vapors and liquids in the vicinity of this orany other appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance
• Do not touch any electrical switch; do not use any phone in your building.
• immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions.
• if you cannot reach your gas supplier, call the fire department.
–installation and service must be performed by a qualified installer, service
agency or the gas supplier.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A
SAFE INSTALLATION, USE AND SERVICE
Your safety and the safety of others is extremely important in the
installation, use and servicing of this water heater.
Many safety-related messages and instructions have been provided in this
manual and on your own water heater to warn you and others of a potential
injury hazard. Read and obey all safety messages and instructions throughout
this manual. It is very important that the meaning of each safety message is
understood by you and others who install, use or service this water heater.
**| This is the safety alert symbol. It is used to alert you to potential
personal injury hazards. Obey all safety messages that follow this symbol to
avoid possible injury or death.
---|---
| DANGER indicates an imminentlyhazardous situation which, if not
avoided, could result in death or injury.
| WARNING indicates a potentially hazardoussituation which, if not
avoided, could result in death or injury.
| CAUTION indicates a potentially hazardoussituation which, if not
avoided, may result in minor or moderate injury.
| CAUTION** used without the safety alert symbol indicates a potentially
hazardous situation which, if not avoided, could result in property damage.
All safety messages will generally tell you about the type of hazard, what can
happen if you do not follow the safety message and how to avoid the risk of
injury.
IMPORTANT DEFINITIONS
Gas Supplier: The natural gas or propane utility or service who supplies gas
for utilization by the gas burning appliances within this application. The gas
supplier typically has responsibility for the inspection and code approval of
gas piping up to and including the natural gas meter or propane storage tank
of a building. Many gas suppliers also offer service and inspection of
appliances within the building.
SAFETY PRECAUTIONS
Read and understand instruction manual and safety messages before installing,
operating or servicing this water heater
Failure to follow instructions and safety messages could result in death or
serious Injury blstruction manual must [emain with water heater
Water temperature over 125°F (52°C) can cause severe burns instantly result ng
in severe injury or death.
Children, the elderly, and the physically or mentalJy dJsabted are at highest
riskfor scald injury.
Feel water before bathing or showering.
Temperature limiting valves are available
Read instruction manual for safe temperature setting
Fire or Explosion Hazard
- Do not store or use gasoline or other flammable vapors and liquids n the vicinity of this or any other appliance
- Avoid all ignition sources if you smell LP gas.
- Do not expose water heater control to excessive gas pressure
- Use only gas shown on rating plate.
- Maintain required clearances to combustibles
- Keep ignition sources away from faucets after,- extended period of non-use.
Read instruction manual before installing, using or servicing water heater
Fire Hazard
For continued protection against risk of fire;
- Do not install water heater on carpeted floor.
- Do not operate water heater if flood damaged
Explosion Hazard
- Overheated water can cause water tank explosion
- Properly sized tempeature end pressure relief valve must be installed in opening provided
Breathing Hazard – Carbon Monoxide Gas
-
Install vent system in accordance with codes
-
Do not operate water heater if flood damaged
• High altitude orifice mustbe installed for operation above 3,300 feet (1,006 m) (or above 5500 (I ,676 m) feet for high altitude models) -
Do not operateifsoot buildup.
-
Do not obstruct water heater air intake with insulating jacket.
-
Do not place chemical vapor emitting products near water heater
-
Gas and carbon monoxide detectors are available
Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual
Improper installation and use may result in property damage.
- Do not operate water heater if flood damaged.
- Inspect and replace anode
- Install in location with drainage.
- Fill tank with water before operat on
- Be alert for thermal expansion
Refer to instruction manual for installation and service.
CUSTOMER RESPONSIBILTIES
Thank You for purchasing a Kenmore water heater. Propedy installed and
maintained, it should give you years of trouble free service. If you should
decide that you want the new water heater professionally installed by Sears
call 1-800-4-MY-HOME ®.
They will arrange for prompt, quality installation by Sears authorized
contractors.
Abbreviations Found In This Instruction Manual:
- CSA – Canadian Standards Association
- ANSI – American National Standards Institute
- NFPA- National Fire Protection Association
- ASME – American Society of Mechanical Engineers
- GAMA – Gas Appliance Manufacturers Association
- This gas-fired water heater is design certified by CSA INTERNATIONAL under American National Standard/CSA Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1 (current edition).
- Read the “Safety Precautions” section, page 3 of this manual first and then the entire manual carefully. If you don’t follow the safety rules, the water heater will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.
This manual contains instructions for the installation, operation, and maintenance of the gas-fired water heater. It also contains warnings through out the manual that you must read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the first few pages, READ THE ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.
-
The installation must conform with these instructions and the local code authority having jurisdiction. In the absence of local codes, installations shall comply with the following: In the United States: The National Fuel Gas Code ANSI Z223.1/NFPA 54. This publication is available from the Canadian Standards Association, 8501 East Pleasant Valley Rd, Cleveland Ohio 44131, or The National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269.
-
If after reading this manual you have any questions or do not understand any portion of the instructions, call the Sears Service Center.
-
Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires. See figure 1.
Examine the location to ensure the water heater complies with the Facts to Consider About the Location section in this manual. -
For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during anearthquake. See instructions for correct installation procedures. Instructions may be obtained from your local dealer, wholesaler, public utilities or California Office of the State Architect, 400 P Street, Sacramento, CA 95814.
-
Massachusetts Code requires this water heater to be installed in accordance with Massachusetts 248-CMR 2.00: State Plumbing Code and 248-CMR 5.00.
-
Complies with SCAQMD rule #1121 and districts having equivalent NOx requirements.
PRODUCT SPECIFICATIONS
MODEL NUMBER| ANK CAPACITY IN GALS (LTRS)| TYPE OF GAS| BTU
RATE| RECOVERY RATE GALS. PER HOUR @ 90°F RISE| MINIMUM VENT PIPE
INCHES (mm)| DIAMETER INCHES (mm)| DIMENSIONS IN INCHES (mm) HEIGHT
TO JACKET TOP
---|---|---|---|---|---|---|---
153336160| 30(114)| NATURAL| 32,000| 32.8| 3″(76)or 4″(102)| 181/4″(464)|
433/4″(1,111)
153.336260| 40 (151)| NATURAL| 35,500| 36.3| 3″(76)or 4″(102)| 20 1/4″ (514)|
47 1/4″ (1,200)
153.336300 HA| 30(114)| NATURAL| 35,500| 36.3| 3″(76)| 15 3/4″ (400)|
571/2″(1,461)
153.336360| 30(114)| NATURAL| 35,500| 36.3| 3″(76)| 15 3/4″ (400)|
571/2″(1,461)
153.336400 HA| 40 (151)| NATURAL| 35,500| 36.3| 3″(76)| 18 1/4″ (464)| 55 1/2″
(1,410)
153.336464| 40 (151)| NATURAL| 35,500| 36.3| 3″(76)| 18 1/4″ (464)| 55 1/2″
(1,410)
153.336500 HA| 50 (189)| NATURAL| 35,500| 36.3| 3″(76)| 20 1/4″ (514)| 56 1/2″
(1,435)
153.336560| 50 (189)| NATURAL| 35,500| 36.3| 3″(76)| 20 1/4″ (514)| 56 1/2″
(1,435)
153.336760| 30(114)| PROPANE| 35,500| 36.3| 3″(76)| 153/4″(400)| 571/2″(1,461)
153.336800 HA| 40 (151)| PROPANE| 35,500| 36.3| 3″(76)| 18 1/4″ (464)| 55 1/2″
(1,410)
153.336860| 40 (151)| PROPANE| 35,500| 36.3| 3″(76)| 18 1/4″ (464)| 55 1/2″
(1,410)
153.336900 HA| 50 (189)| PROPANE| 35,500| 36.3| 3″(76)| 20 1/4″ (514)| 56 1/2″
(1,435)
153.336960| 50 (189)| PROPANE| 35,500| 36.3| 3″(76)| 20 1/4″ (514)| 56 1/2″
(1,435)
MATERIALS AND BASIC TOOLS NEEDED
Materials Needed
To simplify the installation Sears has available the installation parts shown
below. You may or may not need all of these materials, depending on your type
of installation.
Basic Tools
You may or may not need all these tools, depending on your type of
installation. These tools can be purchased at your local Sears Store.
- Pipe Wrenches (2) 14″ (356 mm)
- Screwdriver
- Tin Snips
- 6′ (1.82 m) Tape or Folding Ruler
- Garden Hose
- Drill
- Pipe Dope or Teflon Tape
Additional Tools Needed
When Sweat Soldering
- Tubing Cutters or Hacksaw
- Propane Tank
- Soft Solder
- Solder Flux
- Emery Cloth
- Wire Brushes
TYPICAL INSTALLATION
GET TO KNOW YOUR WATER HEATER – GAS MODELS
A Vent Pipe
B Draft Hood
C Anode
D Hot Water Outlet
E Outlet
F Flexible Water Connections
G Gas Supply
H Manual Gas Shut-off Valve
I Ground Joint Union
J Drip Leg (Sediment Trap)
K [nner Door
L Outer door
M Union
N Inlet Water Shut-off Valve
O Cold Water Iniet
P Inlet Dip Tube
Q Temperature-Pressure Relief Valve
R Rating Plate
S Flue Baffle
T Thermostat
U Drain Valve
V Pilot and Main Burner
W Flue
X Drain Pan
Y Thermostat Shield (optional)
Z Piezo ignitor
AA Air Intake Screen
INSTALLATION INSTRUCTIONS
Removing the Old Water Heater
-
Turn “OFF” the gas supply to the water heater.
If the main gas line Shut-off valve serving all gas appliances is used, also shut “OFF” the gas at each appliance. Leave all gas appliances shut “OFF” until the water heater installation iscompleted, see Figures 2 and 3. -
Turn “OFF” the water supply to the water heater at the water shut off valve or water meter. Some installations require that the water be turned off to the entire house, see Figures 2 and 4.
-
Check again to make sure the supply is “OFF” to thegas water heater. Then disconnect the gas supply connection from the gas control valve. • Burn hazard
• Hot water discharge.
• Keep hands clear of drain valve discharge. -
Attach hose to the water heatera drain valve and put the other end in a floor drain or outdoors. Open the water heater drain valve. Open a nearby hot water faucet which will relieve pressure in the water heater and speed draining. The water passing out of the drain valve may be extremely hot. To avoid being scalded, make sure all connections are tight and that the water flow is directed away from any person, see Figures 2 and 5.
-
Disconnect the vent from the draft hood where it connectspipe to the water heater. In most installations the vent pipe can be lifted off after any screw or other attached devices are removed. Dispose of the draft hood. The new water heater has a draft hood which must be used for proper operation,
-
lf you have copper piping to the water heater, the two copper water pipes can be cut with a hacksaw approximately four inches away from where they connect to the water heater, see Figure 6. This will avoid cutting off pipes too short.
Additional cuts can be made later if necessary. Disconnect the temperature- pressure relief valve drain line. When the water heater is drained, disconnect the hose from the drain valve. Close the drain valve. The water heater is now completely disconnected and ready to be removed.
If you have galvanized pipes to the water heater, loosen the two galvanized
pipes with a pipe wrench at the union in each line. Also disconnect the piping
remaining to the water heater, see Figure 7. These pieces should be saved
since they may be needed when reconnecting the new water heater.
Disconnect the temperature-pressure relief valve drain line.
When the water heater is drained, disconnect the hose from the drain valve.
Close the drain valve. The water heater is now completely disconnected and
ready to be removed.
Mineral buildup or sediment may have accumulated in the old water heater. This
causes the water heater to be much heavier than normal and this residue, if
spilled out, could cause staining.
Facts to Consider About the Location
Carefully choose an indoor location for the new water heater, because the
placement is a very important consideration for the safety of the occupants in
the building and for the most economical use of the appliance. This water
heater is not for use in manufactured (mobile) homes or outdoor installation.
Whether replacing an old water heater or putting the water heater in a new
location, the following critical points must be observed: Select a location
indoors as close as practical to the gas vent or chimney to which the water
heater vent is going to be connected, and as centralized with the water piping
system as possible.
Selected location must provide adequate clearances for servicing and proper
operation of the water heater.
Property Damage Hazard
- AIIwater heaters eventually leak
- Do not install without adequate drainage
Installation of the water heater must be accomplished in such a manner that if
the tank or any connections should leak, the flow will not cause damage to the
structure. For this reason, it is not advisable to install the water heater in
an attic or upper floor.
When such locations cannot be avoided, a suitable drain pan should be
installed under the water heater. Drain pans are available at your local Sears
or hardware store. Such a drain pan must have a minimum length and width of at
least 2 inches (51 mm) greater that the water heater dimensions and must be
piped to an adequate drain. The pan must not restrict combustion air flow.
Fire or Explosion Hazard
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other app))ance
- Avod all ignition sources if you smell LP gas.
- Do not expose water heater centre1to excessive gas pressure
- Use only gas shown on rating pJate.
- Maintain required clearances to combustibles
- Keep ignition sources away from faucets after,. extended period of non use
Read instruction manual before installing, using or servicing water heater
INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS (VAPORS) ARE LIKELY TO BE
PRESENT OR STORED (GARAGES, STORAGE AND UTILITY AREAS, ETC.):
Flammable liquids (such as gasoline, solvents, propane [LP or butane, etc.]
and other substances such as adhesives, etc.) emit flammable vapors which can
be ignited by a gas water heater’s pilot light or main burner. The resulting
flashback and fire can cause death or serious burns to anyone in the area.
Even though this water heater is a flammable vapors ignition resistant water
heater and is designed to reduce the chances of flammable vapors being
ignited, gasoline and other flammable substances should never be stored or
used in the same vicinity or area containing a gas water heater or other open
flame or spark producing appliance.
Also, the water heater must be located and/or protected so it is not subject
to physical damage by a moving vehicle.
Fire Hazard
For continued protection against risk of fire:
- Do not instalJ water heater on carpeted floor
- Do not operate water heater if flood damaged.
This water heater must not be installed directly on carpeting.
Carpeting must be protected by metal or wood panel beneath the appliance
extending beyond the full width and depth of the appliance by at least 3
inches (76.2 mm) in any direction, or if the appliance is installed in an
alcove or closet, the entire floor must be covered by the panel. Failure to
heed this warning may result in a fire hazard.
Fire or Explosion Hazard
Read instruction manual before installing, using or servicing water heaier.
- Improper use may result in fire or explosion
- Maintain required clearances to combustibles.
Minimum clearances between the water heater and combustible construction are 0 inch at the sides and rear, 4 inches (102 mm) at the front, and 6 inches (153 ram) from the vent pipe, see Figure 8. Clearance from the top of the jacket is 12 inches (305 mm) on most models. Note that a lesser dimension may be allowed on some models, refer to the label attached adjacent to the gas control valve on the water heater.
Breathing Hazard – Carbon Monoxide Gas
- Install water heater in accordance with the instruction manual and NFPA 54.
- To avoid injury, combustion and ventilation air must be taken from outdoors.
- Do not place chemical vapor emitting products near water heater.
Breathingcarbon monoxidecan cause brain damage or death. Always read and understandinstructionmanual
A gas water heater cannot operate properly without the correct amount of air for combustion, see Figure 9. Do not install in a confined area such as a closet, unless you provide air as shown in the Locating The New Water Heater section. Never obstruct the flow of ventilation air. If you have any doubts or questions at all, call your gas supplier. Failure to provide the proper amount of combustion air can result in a fire or explosion and cause death, serious bodily injury, or property damage.
If this water heater will be used in beauty shops, barber shops, cleaning
establishments, or self-service laundries with dry cleaning equipment, it is
imperative that the water heater or water heaters be installed so that
combustion and ventilation air be taken from outside these areas.
Propellants of aerosol sprays and volatile compounds, (cleaners, chlorine
based chemicals, refrigerants, etc.) in addition to being highly flammable in
many cases, will also change to corrosive hydrochloric acid when exposed to
the combustion products of the water heater. The results can be hazardous, and
also cause product failure.
Insulation Blankets
Insulation blankets available to the general public for external use on gas
water heaters are not necessary with Kenmore products. The purpose of an
insulation blanket is to reduce the standby heat loss encountered with storage
tank heaters, Your Kenmore water heater meets or exceeds the National
Appliance Energy Conservation Act standards with respect to insulation and
standby loss requirements, making an insulation blanket unnecessary.
Breathing Hazard – Carbon Monoxide Gas
- Do not obstruct water heater air intake with insulating blanket.
- Gas and carbon monoxide detectors are available.
- Install water heater in accordance with the instruction manual.
Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual
WARNING
Should you choose to apply an insulation blanket to this heater, you should
follow these instructions (See Figure 1 for identification of components
mentioned below). Failure to follow these instructions can restrict the air
flow required for proper combustion, potentially resulting in fire,
asphyxiation, serious personal injury or death.
- Do not apply insulation to the top of the water heater, as this will interfere with safe operation of the draft hood.
- Do not cover the outer door, thermostat or temperature & pressure relief valve.
- Do not allow insulation to come within 2″ (50.8 mm) of the floor to prevent blockage of combustion air flow to the burner.
- Do not cover the instruction manual. Keep it on the side of the water heater or nearby for future reference.
- Do obtain new warning and instruction labels from Sears for placement on the blanket directly over the existing labels.
- Do inspect the insulation blanket frequently to make certain it does not sag, thereby obstructing combustion air flow.
Combustion Air and Ventilation for Appliances Located in Unconfined
Spaces
UNCONFINED SPACE is space whose volume is not less than 50 cubic feet per
1,000 Btu per hour (4.8 m 3 per kW) of the aggregate input rating of all
appliances installed in that space. Rooms communicating directly with the
space in which the appliances are installed, through openings not furnished
with doors, are considered a part of the unconfined space.
In unconfined spaces in buildings, infiltration may be adequate to provide air
for combustion, ventilation and dilution of flue gases. However, in buildings
of tight construction (for example, weather stripping, heavily insulated,
caulked, vapor barrier, etc.), additional air may need to be provided using
the methods described in Combustion Air and Ventilation for Appliances Located
in Confined Spaces.
Combustion Air and Ventilation for Appliances Located in Confined
Spaces
CONFINED SPACE is a space whose volume is less than 50 cubic feet per 1,000
Btu per hour (4.8 m 3 per kW) of the aggregate input rating of all appliances
installed in that space.
A. ALL AIR FROM INSIDE BUILDINGS:
(See Figure 9 on page 9 and Figure 10 below)
The confined space shah be provided with two permanent openings communicating
directly with an additional room(s) of sufficient volume so that the combined
volume of all spaces meets the criteria for an unconfined space. The total
input of all gas utilization equipment installed in the combined space shall
be considered in making this determination. Each opening shall have a minimum
free area of one square inch per 1,000 Btu per hour (22 cm_/kW) of the total
input rating of all gas utilization equipment in the confined space, but not
less than 100 square inches (645 cm2). One opening shall commence within 12
inches (30 cm) of the top and one commencing within 12 inches (30 cm) of the
bottom of the enclosures.
B. ALL AIR FROM OUTDOORS: (See Figures 9, 11,12 and 13)
The confined space shall be provided with two permanent openings, one
commencing within 12 inches (30 cm) of the top and one commencing within 12
inches (30 cm) from the bottom of the enclosure. The openings shall
communicate directly, or by ducts, with the outdoors or spaces (crawl or
attic) that freely communicate with the outdoors.
- When directly communicating with the outdoors, each opening shall have a minimum free area of 1 square inch per 4,000 Btu per hour (5.5 cm2/kW) of total input rating of all equipment in the enclosure, see Figure 12.
- When communicating with the outdoors through vertical ducts, each opening shall have a minimum free area of 1 square inch per 4,000 BTU per hour (5.5 cm2/kW) of total input rating of aH equipment in the enclosure, see Figure 12.
- When communicating with the outdoors through horizontal ducts, each opening shall have a minimum free area of 1 square inch per 2,000 BTU per hour (11 cm2/kW) of total input rating of aH equipment in the enclosure, see Figure 13.
- When ducts are used, they shall be of the same crosssectional area as the free area of the openings to which they connect. The minimum short side dimension of rectangular air ducts shall not be less than 3 inches (76.2 mm), see Figure 13.
- Louvers and Grilles: in calculating free area, considerafion shall be given to the blocking effect of louvers, grilles or screens protecting openings. Screens used shall not be smaller than 1/4 inch (6.4 mm) mesh. If the free area through a design of louver or grille is known, it should be used in calculating the size opening required to provide the free area specified. If the design and free area is not known, it may be assumed that wood louvers will be 20-25 percent free area and metal louvers and grilles will have 60-75 percent free area. Louvers and grilles shall be fixed in the open position or interlocked with the equipment so that they are opened automatically during equipment operation.
- Special Conditions Created by Mechanical Exhausting or Fireplaces: operation of exhaust fans, ventilation systems, clothes dryers or fireplaces may create conditions requiring special attention to avoid unsatisfactory operation of installed gas utilization equipment.
Water Piping
Water temperature over 125°F (52°C) car cause severe burns instantly resulting
in severe injury or death.
Children, elderly, and the physically or mentally disabled are at h ghest
risk_or scald injury
Feel water before bathing or showering.
Temperature limiting valves are available. Read instruction manuaJ for safe
temperature setting
HOTTER WATER CAN SCALD:
Water heaters are intended to produce hot water. Water heated to a temperature
which will satisfy space heating, clothes washing, dish washing, cleaning and
other sanitizing needs can scald and permanently injure you upon contact. Some
people are more likely to be permanently injured by hot water than others.
These include the elderly, children, the infirm, or physically/mentally
handicapped. If anyone using hot water in your home fits into one of these
groups or if there is a local code or state law requiring a certain
temperature water at the hot water tap, then you must take special
precautions. In addition to using the lowest possible temperature setting that
satisfies your hot water needs, a means such as a *mixing valve, shall be used
at the hot water taps used by these people or at the water heater. Mixing
valves are available at plumbing supply or hardware stores, see Figure 14
below. Valves for reducing point of use temperature by mixing cold and hot
water are also available. Follow manufacturer’s instructions for
installation of the valves. Before changing the factory setting on the
thermostat, read the Temperature Regulation section in this manual.
Toxic Chemical Hazard
- Do not connect to non-potablewater system.
This water heater shall not be connected to any heating systems or
component(s) used with a non-potable water heating appliance.
All piping components connected to this unit for space heating applications
shall be suitable for use with potable water.
Toxic chemicals, such as those used for boiler treatment shall not be
introduced into this system.
Water supply systems may, because of such events as high line pressure,
frequent cut-offs or the effects of water hammer among others, have installed
devices such as pressure reducing valves, check valves, back flow preventers,
etc. to control these types of problems. When these devices are not equipped
with an internal by-pass, and no other measures are taken, the devices cause
the water system to be closed. As water is heated, it expands (thermal
expansion) and closed systems do not allow for the expansion of heated water.
The water within the water heater tank expands as it is heated and increases
the pressure of the water system. If the relieving point of the water heater’s
temperature-pressure relief valve is reached, the valve will relieve the
excess pressure. The temperature-pressure relief valve is not intended for the
constant relief of thermal expansion. This is an unacceptable condition and
must be corrected, It is recommended that any devices installed which could
create a closed system have a by-pass and/or the system have an expansion tank
to relieve the pressure built by thermal expansion in the water system. Refer
to the Thermal Expansion section under Troubleshooting Guide or contact local
plumbing authority or local Sears Service Center on how to control this
situation.
NOTE: To protect against untimely corrosion of hot and cold water
fittings, it is strongly recommended that di-electric unions or couplings be
installed on this water heater when connected to copper pipe.
Property Damage Hazard
- Avoid water heater damage.
- Install thermal expansion tank if necessary.
- Do not apply heat to cold water inlet.
- Contact qualified insta/ier or Sears Service Center
Figure 15 shows the typical attachment of the water piping to the water
heater. The water heater is equipped with 3/4″ NPT water connections.
NOTE: if using copper tubing, solder tubing to an adapter before
attaching the adapter to the cold water inlet connection. Do not solder the
cold water supply line directly to the cold water inlet. It will harm the dip
tube and damage the tank.
- Look at the top cover of the water heater. The water outlet is marked “HOT”. Put two or three turns of teflon tape around the threaded end of the threaded-to-sweat coupling and around both ends of the 3/4″ NPT threaded nipple. Using flexible connectors, connect the hot water pipe to the hot water outlet on the water heater.
- Lookatthetopofthewaterheater.Thecoldwaterinletis marked “COLD”. Put two or three turns of teflon tape around the threaded end of the threaded-to-sweat coupling and around both ends of the 3/4″ NPT threaded nipple. Using flexible connectors, connect the cold water pipe to the cold water inlet of the water heater.
NOTE: This water heater is super insulated to minimize heat loss from the tank. Further reduction in heat loss can be accomplished by insulating the hot water lines from the water heater.
Temperature-Pressure Relief Valve
Explosion Hazard
- Temperature-pressure relief valve must comply with ANSI Z21.22 and ASME code
- Properly sized temperaturepressure relief valve must be installed in opening provided.
- Can result in overheating and excessive tank pressure.
- Can cause serious injury or death.
This heater is provided with a properly certified combination temperature –
pressure relief valve by the manufacturer.
The valve is certified by a nationally recognized testing laboratory that
maintains periodic inspection of production of listed equipment of materials
as meeting the requirements for Relief Valves and Automatic Gas Shut-off
Devices for Hot Water Supply Systems, ANSI Z21.22 and the code requirements of
ASME.
If replaced, the valve must meet the requirements of local codes, but not less
than a combination temperature and pressure relief valve certified as
indicated in the above paragraph.
The valve must be marked with a maximum set pressure not to exceed the marked
hydrostatic working pressure of the water heater (150 psi = 1,035kPa) and a
discharge capacity not less than the water heater input rate as shown on the
model rating plate.
For safe operation of the water heater, the relief valve must not be removed
from its designated opening nor plugged.
The temperature-pressure relief valve must be installed directly into the
fitting of the water heater designed for the relief valve. Position the valve
downward and provide tubing so that any discharge will exit only within 6
inches (153 mm) above, or at any distance below the structural floor, see
Figure 16. Be certain that no contact is made with any live electrical part.
The discharge opening must not be blocked or reduced in size under any
circumstances. Excessive length, over 30 feet (9.14 m), or use of more than
four elbows can cause restriction and reduce the discharge capacity of the
valve.
No valve or other obstruction is to be placed between the relief valve and the
tank. Do not connect tubing directly to discharge drain unless a 6 inch air
gap is provided. To prevent bodily injury, hazard to life, or property damage,
the relief valve must be allowed to discharge water in quantities should
circumstances demand. If the discharge pipe is not connected to a drain or
other suitable means, the water flow may cause property damage.
Water Damage Hazard
- Temperature-pressure relief valve discharge pipe must terminate at adequate drain.
The Discharge Pipe:
- Shall not be smaller in size than the outlet pipe size of the valve, or have any reducing couplings or other restrictions.
- Shall not be plugged or blocked.
- Shall be of material listed for hot water distribution.
- Shall be installed so as to allow complete drainage of both the temperature-pressure relief valve, and the discharge pipe.
- Shall terminate at an adequate drain.
- Shall not have any valve between the relief valve and tank.
Water temperature over 125°F (52°C) can cause severe burns instantly resulting
in severe injury or death.
Children, the elderly, and the physically or mentally disabled are at highest
risk for scald injury.
Fee. water before bathing or showering Temperature limiting valves are
available.
Read instruction manual for safe temperature setting.
The temperature-pressure relief valve must be manually operated at least once
a year. Caution should be taken to ensure that (1) no one is in front of or
around the outlet of the temperature-pressure relief valve discharge line, and
(2) the water manually discharged will not cause any bodily injury or
property damage because the water may be extremely hot.
If after manually operating the valve, it fails to completely reset and
continues to release water, immediately close the cold water inlet to the
water heater, follow the draining instructions, and replace the temperature-
pressure relief valve with a new one.
Filling the Water Heater
Property Damage Hazard
- Avoid water heater damage.
- Fill tank with water before operating
Never use this water heater unless it is completely full of water.
To prevent damage to the tank, the tank must be filled with water. Water must
flow from the hot water faucet before turning “ON” gas to the water heater.
To fill the water heater with water:
-
Close the water heater drain valve by turning the handle to the right (clockwise). The drain valve is on the lower front of the water heater.
-
Open the cold water supply valve to the water heater.
NOTE: The cold water supply valve must be left open when the water heater is in use. -
To insure complete filling of the tank, allow air to exit by opening the nearest hot water faucet. Allow water to run until a constant flow is obtained. This will let air out of the water heater and the piping.
-
Check all water piping and connections for leaks. Repair as needed.
Venting
Breathing Hazard – Carbon Monoxide Gas
- Vent dampers must be certified inaccordance with ANSIZ21.68.
- Vent damper must permit proper drafting of water heater.
- Install properly sized venting.
- Da not install without venting outdeors.
- Donotinstall withoutdrafthood.
- if common1 vented install in accordance with NFPA 54
- Be alert for obstructed or deterio- rated vent system to avoid serious injury or death
Breathing carbon mono×ide can cause brain damage or death Always read and understand nstruction manual
VENT DAMPERS – Any vent damper, whether it is operated thermally or otherwise
must be removed if its use inhibits proper drafting of the water heater.
Thermally Operated Vent Dampers: Gas-fired water heaters having thermal
efficiency in excess of 80% may produce a relatively low flue gas temperature.
Such temperatures may not be high enough to properly open thermally operated
vent dampers. This would cause spillage of the flue gases and may cause carbon
monoxide poisoning.
Vent dampers must bear evidence of certification as complying with the current
edition of the American National Standard ANSI Z21.68 (ANSI Z21.66 & 67,
respectively, cover electrically and mechanically actuated vent dampers).
Before installation of any vent damper, consult your local Sears Service
Center or the local gas supplier for further information.
To insure proper venting of this gas-fired water heater, the correct vent pipe
diameter must be utilized. Any additions or deletions of other gas appliances
on a common vent with this water heater may adversely affect the operation of
the water heater. Consult your gas supplier if any such changes are planned.
For proper venting in certain installations, a larger diameter vent pipe may
be necessary. Consult your local Sears Service Center or gas supplier to aid
you in determining the proper venting for your water heater from the vent
tables in the current edition of the National Fuel Gas Code ANSI 2223.1/NFPA
54.
Periodically check the venting system for signs of obstruction or
deterioration and replace if needed.
The combustion and ventilation air flow must not be obstructed.
The water heater with draft hood installed must be connected to a chimney or
listed vent pipe system, which terminates to the outdoors. Never operate the
water heater unless it is vented to the outdoors and has adequate air supply
to avoid risks of improper operation, explosion or asphyxiation.
- For proper draft hood attachment, the draft hood legs may be angled slightly inward.
- Place the draft hood legs in the receiving holes on the top of the water heater. The legs will snap in the holes to give a tight fit. Secure two legs to top with sheet metal screws.
- Place the vent pipe over the draft hood. With the vent pipe in position, drill a small hole through both the vent pipe and draft hood. Secure them together with a sheet metal screw, see Figure 17.
Obstructed or deteriorated vent systems may present serious health risk or
asphyxiation.
The vent pipe from the water heater must be no less than the diameter of the
draft hood outlet on the water heater and must slope upward at least 1/4 inch
per linear foot (21 mm per meter), see Figure 18,
All vent gases must be completely vented to the outdoors of the structure
(dwelling), Install only the draft hood provided with the new water heater and
no other draft hoed. Vent pipes must be secured at each joint with sheet metal
screws,
There must be a minimum of 6 inches (153 mm) clearance between single wall
vent pipe and any combustible material. Fill and seal any clearance between
single wall vent pipe and combustible material with mortar mix, cement, or
other noncombustible substance, For other than single wall, follow vent pipe
manufacturer’s clearance specifications, To insure a tight fit of the vent
pipe in a brick chimney, seal around the vent pipe with mortar mix cement,
Failure to have required clearances between vent piping and combustible
material will result in a fire hazard,
Be sure vent pipe is propedy connected to prevent escape of dangerous flue
gases which could cause deadly asphyxiation.
Breathing Hazard – Carbon Monoxide Gas
- Flue gases may escape If vent pipe is not connected.
- Do net store corrosive chemicals inv cinity of water heater.
- Chemical corresion of flue and vent system can cause serious injury or death.
- Contact a qualified installer or service agency.
Breathing carbon monoxide can cause brain camage ordeath Always read and understand instruction manual.
Chemical vapor corrosion of the flue and vent system may occur if air for
combustion contains certain chemical vapors.
Spray can propellants, cleaning solvents, refrigerator and air conditioner
refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes,
bleach and process chemicals are typical compounds which are potentially
corrosive.
Gas Piping
Fire and Explosion Hazard
- Do not use water heater with any gas other than the gas shown on the rating plate
- Excessve pressure to gas control valve can cause serious injury or death
- Turn off gas lines during installation
- Contact qualified installer or service agency
Make sure the gas supplied is the same type listed on the model rating plate.
The inlet gas pressure must not exceed 14 inch water column (3.5kPa) for
natural and propane gas (L.P.). The minimum inlet gas pressure listed on the
rating plate is for the purpose of input adjustment. If the gas control valve
is subjected to pressures exceeding 1/2 pound per square inch (3.5kPa), the
damage to the gas control valve could result in a fire or explosion from
leaking gas.
if the main gas line shut-off serving all gas appliances is used, also turn
“OFF” the gas at each appliance. Leave all gas appliances shut “OFF” until the
water heater installation is complete.
A gas line of sufficient size must be run to the water heater. Consult the
current edition of National Fuel Gas Code ANSI 2223.1/NFPA 54 and your gas
supplier concerning pipe size.
There must be:
- Areadily accessible manual shut off valve in the gas supply line serving the water heater, and
- Adrip leg (sediment trap) ahead of the gas control valve to help prevent dirt and foreign materials from entering the gas control valve.
- A flexible gas connector or a ground joint union between the shut off valve and control valve to permit servicing of the unit.
Be sure to check all the gas piping for leaks before lighting the water
heater. Use a soapy water solution, not a match or open flame. Rinse off soapy
solution and wipe dry.
The minimum inlet gas pressure shown on the rating plate is that which will
permit firing at the rated input.
Breathing Hazard – Carbon Monoxide Gas
- High altitude orifice must be installed for operation above 3,300 ft. (1,006 m) or 5.500 tt. (1.6/8 m) tor a high altitude madels.
- Contact a qualified installer or service agency.
Breathing carocn monoxide can cause brain damage or death. Always read and understand instruction manual.
If a standard model is installed above 3,300 feet (1,006 m) or a high altitude
model is installed above 5,500 feet (1,676 m) the input rating should be
reduced at the rate of 4 percent for each 1,000 feet (305 m ) above sea level
which requires replacement of the burner orifice in accordance with National
Fuel Gas Code ANSI Z223.1IN FPA 54. Contact your local Sears Service Center or
local gas supplier for further information.
Failure to replace the standard orifice with a high altitude orifice when
installed at elevations above 3,300 feet (1,006 m) or above 5,500 feet (1,676
m) for high altitude model) could result in improper and inefficient operation
of the appliance, producing carbon monoxide gas in excess of safe limits,
which could result in serious injury or death, Contact your local Sears
Service Center or local gas supplier for any specific changes which may be
required in your area,
Fire and Explosion Hazard
- Use joint compound or tape corn patible with propane
- Leak test before operating heater
- Disconnect gas p!ping and shut-off valve before pressure testing system
Use pipe joint compound or teflon tape marked as being resistant to the action
of petroleum (Propane [L,R]) gases.
The appliance and its gas connection must be leak tested before placing the
appliance in operation.
The appliance and its individual shut-off valve shall be disconnected from the
gas supply piping system during any pressure testing of that system at test
pressures in excess of 1/2 pound per square inch (3.5kPa). It shall be
isolated from the gas supply piping system by closing its individual manual
shut-off valve during any pressure testing of the gas supply piping system at
test pressures equal to or less than 1/2 pound per square inch (3.5kPa).
Connecting the gas piping to the gas control valve of the water heater can be
accomplished by either of the two methods shown in Figures 19 and 20.
Sediment Traps
Fire and Explosion Hazard
- Contaminants in gas lines can cause fire or explosion.
- Clean all gas piping before installation.
- Install drip leg in accordance with NFPA 54,
Contaminants in the gas lines may cause improper operation of the gas control valve that may result in fire or explosion. Before attaching the gas line be sure that all gas pipe is clean on the inside. To trap any dirt or foreign material in the gas supply line, a drip leg (sometimes called a sediment trap) must be incorporated in the piping. The drip leg must be readily accessible. Install in accordance with the Gas Piping section. Refer to the current edition of the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
A sediment trap shall be installed as close to the inlet of the water heater as practical at the time of water heater installation. The sediment trap shall be either a tee fitting with a capped nipple in the bottom outlet or other device recognized as an effective sediment trap. If a tee fitting is used, it shall be installed in conformance with one of the methods of installation, shown in Figures 19 and 20.
OPERATING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: ff you do not follow these instructions exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
BEFORE OPERATING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM
ALL LINES.
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to
smell next to the floor because some gas is heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS:
- Donottry te light any appliance.
- Donottouch any electric switch; do not use any phone in your building.
- immediately call your gas supplier from a neighbor’s phone. Foliow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use
tools. If the knob will not push in or tum by hand, don’t try to repair it,
call a qualified service technician . Force or attempted repair may result in
a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately
cali a qualified service technician to inspect the appliance and to replace
any part of the control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS
-
STOP! Readthesafetyinformation above on this label.
-
Set the thermostat to lowest setting (PILOT SETTING).
Turn thermostat dial fully clockwise until it stops. -
Push thegas control knobdown slightly and turn clockwise to”OFF”, SEE FIGURE “A”.
NOTE: Knob CANNOT beturned from “PILOT” to “OFF” unless it is pushed down slightly. Do not force. -
Remove the outer burner door located below the gas control.
-
Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow”B” in the safety information above on this label. Ifyou don’t smell gas, go to next step.
-
This unit is equipped with a push button pilot ignitor,which is used to light the pilot. Locate the ignitor on the gas control.
-
Turn gas control knob counterclockwise to “PILOT”, SEEFIGURE “B”.
-
The pilot is located on the right side of the burner. It can be located by looking through the glass view port while pressing the pieze ignitor button several times. Look for a spark at the pilot location, FIGURE”D”.
-
Once the pilot has been found, push the gas knob all the way down. Immediately press the pilot ignitor button rapidly (4) to (5) times. If the pilot will net light, repeat step (3) through (9).
-
Continue to hold the gas control knob down for about one (1) minute after the pilot is lit. Release the gas control knob and it will pep back up. Pilot should remain lit.If it goes out, repeat step (3) through (9). It may take several minutes for air to clear the lines before the pilot will light.
If knob does not pop up when released, stop and immediately call your service technician or gas supplier.
If the pilot will not stay lit after several tries, turn the gas control knob clockwise to “OFF” and call your service technician orgas supplier. SEE FIGURE”A”. -
Once the pilot flame is establishedreplace the euter bumer door.
-
At arms length away, turn gas control knob counterclockwise to”ON”. SEE FIGURE”C”.
-
Set thermostat to desired setting.
DANGER: Hotter water increases the risk of scald injury. Consult the instruction manual before changing temperature.
TOTURN OFF GAS TO APPLIANCE
- Set thermostat to the lowest setting (PILOT LIGHTING).
- Push gas control knob down slightly and turn clockwise to “OFF”. Do not force. SEE FIGURE “A”.
Water temperature over 125°F (52°0) can cause severe burns instantly resulting
in severe injury or death.
Children, the elderly, and the physically or mentally disabled are at highest
risk for scald injury
Feel water before bathing or showering.
Temperature limiting valves are available Read instruction manual for safe
temperature setting
HOTTER WATER CAN SCALD: Water heaters are intended to produce hot water. Water
heated to a temperature which will satisfy space heating, clothes washing,
dish washing, and other sanitizing needs can scald and permanently injure you
upon contact. Some people are more likely to be permanently injured by hot
water than others. These include the elderly, children, the infirm, or
physically/mentally handicapped. If anyone using hot water in your home fits
into one of these groups or if there is a local code or state law requiring a
certain temperature water at the hot water tap, then you must take special
precautions. In addition to using the lowest possible temperature setting that
satisfies your hot water needs, a means such as a mixing valve, shall be used
at the hot water taps used by these people or at the water heater. Mixing
valves are available at plumbing supply or hardware stores. Follow
manufacturer’s instructions for installation of the valves. Before changing
the factory setting on the thermostat, read the Temperature Regulation section
in this manual, see Figures 21 and 22.
Never allow small children to use a hot water tap, or to draw their own bath
water. Never leave a child or handicapped person unattended in a bathtub or
shower.
NOTE: A water temperature range of 120°F-140°F (49°C-60°C) is recommended
by most dishwasher manufacturers.
The thermostat of this water heater has been factory set at its lowest
position. It is adjustable and must be reset to the desired temperature
setting to reduce the risk of scald injury.
The mark ( ****) indicative of approximately 120°F (49°0) is preferred
starting point. Some states have a requirement for a lower setting.
Turn the water temperature dial clockwise ( ) to decrease the temperature, or
counterclockwise ( ) to increase the temperature.
Should overheating occur or the gas supply fail to shut off, turn off the
manual gas control valve to the appliance.
SERVICE AND ADJUSTMENT
Tank (Sediment) Cleaning
Sediment build-up on the tank bottom may create varying amount of noise, and
if left in the tank will cause permanent tank failure, tn some water areas,
you may not be able to drain all sediment deposits by simply draining the
tank. In these cases Mag-Erad (part no. 23600) can be used to help remove the
sediment deposits. This may be ordered from the Sears Service Center. For
ordering, refer to the Parts Order List section.
Vent System Inspection
Carbon Monoxide and Fire Hazard
- Flue gases may escape if vent pipe is not connected.
- Be alert for obstructed, sooted or deteriorated vent system to avoid serious injury or death.
- Do not store corrosive chemicals in vicinity of water heater.
- Chemical corrosion of flue and vent system can cause serious injury or death
Breathing carbon moroxide can cause brain damage or death. Always reac and understand instruction manual
At least once a year a visual inspection should be made of the
venting system. You should look for:
- Obstructions which could cause improper venting. The combustion and ventilation air flow must not be obstructed.
- Damage or deterioration which could cause improper venting or leakage of combustion products.
- Rusted flakes around top of water heater.
Be sure the vent piping is properly connected to prevent escape of dangerous
flue gasses which could cause deadly asphyxiation.
Obstructions and deteriorated vent systems may present serious health risk or
asphyxiation.
Chemical vapor corrosion of the flue and vent system may occur if air for
combustion contains certain chemical vapors.
Spray can propellants, cleaning solvents, refrigerator and air conditioner
refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes,
bleach and process chemicals are typical compounds which are potentially
corrosive.
If when inspecting the vent system you find sooting or deterioration,
something is wrong. Call the local gas supplier to correct the problem and
clean or replace the flue and venting before resuming operation of the water
heater.
Burner Inspection
Flood damage to a water heater may not be readily visible or immediately
detectable. However, over a period of time a flooded water heater will create
dangerous conditions which can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY
DAMAGE. Contact a Sears Service Center to replace a flooded water heater. Do
not attempt to repair the unit! It must be replaced!
At least once a year a visual inspection should be made of the main burner and
pilot burner, see Figure 23.
You should check for sooting. Soot is not normal and will impair proper
combustion.
Soot build-up indicates a problem that requires correction before further use.
Turn “OFF” gas to water heater and leave “OFF” until repairs are made, because
failure to correct the cause of the sooting can result in a fire causing
death, serious injury, or property damage.
Burner Cleaning
Fire or Explosion Hazard
Failure to properly reseal the combustion chamber will disable the flammable
vapor ignition resistance feature of this water heater, which could result in
death or serious injury Contact your local Sears Service Center for assistance
Read instruction manual before installing, using or servicing water heater
In the event your burner needs cleaning, following these instructions:
If inspection of the burner shows that cleaning is required, turn the gas
control knob clockwise ( ) to the “OFF” position, depressing slightly.
NOTE: The knob cannot be turned from “PILOT” to “OFF” unless knob is
depressed slightly. DO NOT FORCE.
The burner needs to be removed for cleaning. Call the Sears Service Center to
remove and clean the burner and correct the problem that required the burner
to be cleaned.
Housekeeping
Vacuum around base of water heater for dust, dirt, and lint on a regular
basis.
Fire and Explosion Hazard
- Do not obstruct combustion air openings at the bottom of the water heater
- Do not use or stere flammable vapor products such as gasoline, solvents or adhesives in the same room or area rlear water heater or other appliance
- Visibly inspect air intake screen at least once every six months and clean if accumulated lint
- Can cause serious injury or death
AT LEAST ONCE EVERY SIX MONTHS A VISUAL INSPECTION SHOULD BE MADE OF THE AIR
INTAKE SCREEN. CLEAN IF LINT ACCUMULATIONS ARE NOTICED.
INSTALLED IN SUITABLEAREA: To insure sufficient ventilation and combustion air
supply, proper clearances from the water heater must be maintained. See Facts
to Consider About the Location section. Combustible materials such as
clothing, cleaning materials, or flammable liquids, etc. must not be placed
against or adjacent to the water heater because they could catch on fire.
Anode Rod Inspection
Property Damage Hazard
- Avoid water heater damage
- InlspectJon arid replacement of anode rod required
The anode rod is used to protect the tank from corrosion. Most hot water tanks
are equipped with an anode rod. The submerged rod deteriorates to protect the
tank. Instead of corroding the tank, water ions attack and eat away the anode
red. This does not affect the water’s taste or color. The rod must be
maintained to keep the tank in operating condition.
Anode deterioration depends on water conductivity, not necessarily water
condition. A corroded or pitted anode rod indicates high water conductivity
and should be checked and/ or replaced more often than an anode rod that
appears to be intact. Replacement of a depleted anode rod can extend the life
of your water heater. Inspection should be conducted by calling the Sears
Service Center for an authorized contractor. At a minimum, the anede(s) should
be checked annually after the warranty period.
Temperature-Pressure Relief Valve Operation
The temperature-pressure relief valve must be manually operated at least once
a year.
- Burn hazard
- Hot water discharge.
- Keep clear of relief valve discharge outlet.
When checking the temperature-pressure relief valve operation, make sure that (1) no one is in front of or around the outlet of the temperature-pressure relief valve discharge line, and (2) that the water discharge will not cause any property damage, as the water may be extremely hot, see Figure 24.
If after manually operating the valve, it fails to completely reset and
continues to release water, immediately close the cold water inlet to the
water heater, follow the draining instructions, and replace the temperature-
pressure relief valve with a new one.
If the temperature-pressure relief valve on the appliance weeps or discharges
periodically, this may be due to thermal expansion. You may have a check valve
installed in the water line or a water meter with a check valve. Consult the
Sears Service Center for further information. Do not plug the temperature-
pressure relief valve.
Draining
- Burn hazard
- Hot water discharge.
- Keep hands clear of drain valve discharge.
The water heater should be drained if being shut down during freezing temperatures. Also periodic draining and cleaning of sediment from the tank may be necessary.
-
Turn the gas control knob to the “OFF” position.
-
CLOSE the cold water inlet valve to the water heater.
-
OPEN a nearby hot water faucet and leave open to allow for draining.
-
Connect a hose to the drain valve and terminate to an adequate drain.
-
OPEN the water heater drain valve to allow for tank draining.
NOTE: If the water heater is going to be shut down and drained for an extended period, the drain valve should be left open with hose connected allowing water to terminate to an adequate drain. -
CLOSE the drain valve.
-
Follow instructions in the Filling The Water heater section.
-
Follow the lighting instructions in the Lighting section to restart the water heater.
Drain Valve Washer Replacement
(See Figure 25)
- Turn “OFF” gas supply to water heater.
- Follow “Draining” instructions.
- Turning counter clockwise ( ), remove the hex cap below the screw handle.
- Remove the washer and put the new one in place.
- Screw the handle and cap assembly back into the drain valve and retighten using a wrench. DO NOT OVER TIGHTEN.
- Follow instructions in the Filling The Water Heater section.
- Check for leaks.
- Follow the lighting instructions in the Lighting section to restart the water heater.
Service
Before calling for repair service, read the Start Up Conditions and
Operational Conditions found in the Troubleshooting Guide of this manual.
If a condition persists or you are uncertain about the operation of the water
heater, let the Sears Service Center check it out.
Contact Sears Service Center at:
1-800-4-MY-HOME (1-800-469-4663).
TROUBLESHOOTING GUIDE
Start Up Conditions
Thermal Expansion
Property Damage Hazard
- Avoid water heater damage
- Install thermal e×paneion tank if necessary
- Contact quatified installer or sewice agency
Water supply system may, because of such events as high line pressure,
frequent cut-offs, and the effects of water hammer have installed devices such
as pressure reducing valves, check valves, back flow preventers, etc., to
control these types of problems. When these devices are not equipped with an
internal by-pass, and no other measures are taken, the devices cause the water
system to be closed. As water is heated, it expands (thermal expansion} and
closed systems do not allow for the expansion of heated water.
The water within the water heater tank expands as it is heated and increases
the pressure of the water system. If the relieving point of water heater’s
temperature-pressure relief valve is reached, the valve will relief the excess
pressure. The temperature-pressure relief valve is not intended for the
constant relief of thermal expansion. This is an unacceptable condition and
must be corrected,
It is recommended that any devices installed which could create a closed
system have a by-pass and/or the system have an expansion tank to relieve the
pressure built by thermal expansion. Thermal expansion tanks are available
from Sears stores and through the Sears Service Centers. Contact the local
plumbing inspector, water supplier and/or the Sears Service Center for
assistance in controlling these situations, see Figure 26.
Thermal Expansion Tank Specifications
Model Number| Tank Capacity In Gallons| Dimensions in
Inches| Pipe Fitting On Tank
---|---|---|---
Diameter| Length
153.331929| 2| 8(293rnm)| 12-3/4(323mm)| 3/4″Male
153.331050| 5| 11 (279 mm)| 14-3/4 (375 mm)| 3/4″ Male
Expansion Tank Sizing Chart
Expansion
Tank Capacity
Needed| Inlet Water Pressure| * Water Heater Capacity (Ganons]
---|---|---
30| 40| 50| 66| 80
40psi| 2| 2| 2| 5| 5
50psi| 2| 2| 2| 5| 5
60psi| 2| 2| 5| 5| 5
70psi| 2| 2| 5| 5| 5
80psi| 2| 5| 5| 5| 5
*Highest recorded inlet water pressure in a 24 hour period or regulated water pressure.
NOTE: Expansion tanks are pre-charged with a 40 psi air charge. If the inlet water pressure is higher than 40 psi, the expansion tank’s air pressure must be adjusted to match that pressure, but must not be higher than 80 psi.
Strange Sounds
Possible noises due to expansion and contraction of some metal parts during
periods of heat-up and cool-down do not represent harmful or dangerous
conditions.
Condensation causes sizzling and popping within the burner area during heating
and cooling periods and should be considered normal. See Condensation section.
Draft Hood Operation
Check draft hood operation by performing a worst case depressurization of the
building. With all doors and windows closed, and with all air handling
equipment and exhaust fans operating such as furnaces, clothes dryers, range
hoods and bathroom fans, a match flame should still be drawn into the draft
hood of the water heater with its burner firing. If the flame is not drawn
toward the draft hood, shut off water heater and make necessary air supply
changes to correct.
Condensation
Whenever the water heater is filled with cold water, some condensate will form
while the burner is on. A water heater may appear to be leaking when in fact
the water is condensation.
This usually happens when:
- Anew water heater is filled with cold water for the first time.
- Burning gas produces water vapor In water heaters, particularly high efficiency models where flue temperatures are lower.
- Large amounts of hot water are used in a short time and the refill water in the tank is very cold.
Moisture from the products of combustion condense on the cooler tank surfaces
and form drops of water which may fall onto the burner or other hot surfaces
to produce a “sizzling” or “frying” noise.
Excessive condensation can cause pilot outage due to water running down the
flue tube onto the main burner and putting out the pilot.
Because of the suddenness and amount of water, condensation water may be
diagnosed as a “tank leak”. After the water in the tank warms up (about 1-2
hours), the condition should disappear.
Do not assume the water heater is leaking until there has been enough time for
the water in the tank to warm up.
An undersized water heater will cause more condensation. The water heater must
be sized properly to meet the family’s demands for hot water including
dishwashers, washing machines and shower heads.
Excessive condensation may be noticed during the winter and eany spring months
when incoming water temperatures are at their lowest.
Good venting is essential for a gas fired water heater to operate properly as
well as to carry away products of combustion and water vapor.
Smoke Odo
It is not uncommon to experience a small amount of smoke and odor during
the initial start-up. This is due to burning off of oil from metal parts, and
will disappear in a short while.
Operational Conditions
Smelly Odor
In each water heater there is installed at least one anode rod (see parts
section) for corrosion protection of the tank. Certain water conditions will
cause a reaction between this rod and the water. The most common complaint
associated with the anode rod is one of a “rotten egg smell”. This odor is
derived from hydrogen sulfide gas dissolved in the water. The smell is the
result of four factors which must all be present for the odor to develop:
- aconcentration of sulfate in the supply water.
- little or no dissolved oxygen in the water.
- a sulfate reducing bacteria within the water heater. (This harmless bacteria is non-toxic to humans.)
- an excess of active hydrogen in the tank. This is caused by the corrosion protective action of the anode.
Smelly water may be eliminated or reduced in some water heater models by
replacing the anode(s) with one of less active material, and then chiorinating
the water heater tank and all hot water lines. Contact Sears Service for
further information concerning an Anode Replacement Kit #9001453 and this
Chlorination Treatment.
lf the smetly water persisis after the anode replacement and chlorination
treatment, we can only suggest that chlorination or aeration of the water
supply be considered to eliminate the water problem.
Do not remove the anode feaving the tank unprotected. By doing so, atl
warranty on the water heater tank is voided.
“AIR” in Hot Water Faucets
Explosion Hazard
- Flammable hydregen gases may be resent
- Keep all grtion sources awey “rom faucet when turning on hel water.
HYDROGEN GAS: Hydrogen gas can be produced in a hot water system that has not
been used for a long period of time (generally two weeks or more). Hydrogen
gas is extremely flammable and explosive. To prevent the possibility of injury
under these conditions, we recommend the hot water faucet, located farthest
away, be opened for several minutes before any electrical appliances which are
connected to the hot water system are used (such as a dishwasher or washing
machine).
If hydrogen gas is present, there will probably be an unusual sound similar to
air escaping through the pipe as the hot water faucet is opened. There must be
no smoking or open flame near the faucet at the time it is open.
High Temperature Shut-Off System
This water heater is equipped with an automatic gas shutoff system. This
system works when high water temperatures are present. Turn “OFF” the entire
gas supply to the water heater. The high temperature shutoff is built into the
gas control valve. It is non-resettable. If the high temperature shutoff
activates, the gas control valve must be replaced. Contact your gas supplier.
Operational Conditions (Continued)
Read and understand instruction manual and safety messages before installing,
operating or servicingthis water heaten
Failure to follow instructions and safety messages could result in death
orserious injury
Instruction Manual must remain with water heater
Read this manual first, Then before checking the water heater make sure the
gas supply has been turned “OFF”, and never turn the gas “ON” before the tank
is completely full of water.
Never use this water heater unless it is completely filled with water. To
prevent damage to the tank, the tank must be filled with water. Water must
flow from the hot water faucet before turning “ON” gas to the water heater,
see Figure 27.
A Water at the draft hood is water vapor which has condensed out of the
combustion products. This is caused by a problem in the vent. Contact the gas
utility.
B. Condensation may be seen on pipes in humid weather or pipe connections may
be leaking.
C. The anode rod fitting may be leaking.
D. Small amounts of water from temperature-pressure relief valve may be due to
thermal expansion or high water pressure in your area.
E. The temperature-pressure relief valve may be leaking at the tank fitting.
R Water from a drain valve may be due to the valve being slightly opened.
G. The drain valve may be leaking at the tank fitting.
H. Combustion products contain water vapor which can condense on the cooler
surfaces of the tank. Droplets form and drip onto the burner or run on the
floor. This is common at the time of start-up after installation and when
incoming water is cold.
I Water in the water heater bottom or on the floor may be from condensation,
loose connections, or the relief valve.
DO NOT replace the water heater until a full inspection of all possible water
sources is made and necessary corrective steps taken.
Leakage from other appliances, water lines, or ground seepage should also be checked.
- To check where threaded portion enters tank, insert cotton swab between jacket opening and fitting. If cotton is wet, follow “Draining” instructions in the Periodic Maintenance section and then remove fitting. Put pipe dope or teflon tape on the threads and replace. Then follow Filling the Water Heater instructions in the Installing the New Water Heater section.
These guidelines shouid be used by a qualified service agent. Call Sears Service at 1-800-4-MY-HOME (1-800-469-46 for assistance. inform the associate that this is a “Flammable Vapor Ignition Resistant’ Product.
Problem | Cause | Solution |
---|---|---|
WATER LEAKS | Improperly sealed. hot or cold supply connection, relief valve, | |
drain valve. or thermostat threads. | Tighten threaded connections. | |
Leakage from other appliances or water lines. | Inspect other appliances near |
water heater.
Condensation of nue products.| Refer to CONDENSATION.
LEAKING T&P VALVE| Thermal expansion :n closed water system.| Install thermal
expansion tank (DO NOT plug T&P valve).
Improperly seated valve.| Check relief valve for proper operation (DO NOT plug
T&P valve).
SMELLY ODORS| High sulfate or mineral content in water supply.| Drain and
flush heater thoroughly. then refill.
Bacteria in water supply.| Chlorinate or aerate water supply.
PILOT WILL NOT LIGHT| Gas control knob not positioned correctly.| Refer to
LIGHTING INSTRUCTIONS.
Main gas supply off.| Turn on main gas shutoff valve.
Igniter tip more than 1/8 from pilot hood.| Adjust ignitor tip.
Thermocouple malfunction.| Replace pilot assembly.
Thermocouple TCO malfunction.| Replace pilot assembly.
Melted insulation on ignitor wire or shorting of ignitor wire.| Contact Sears
Service to determine cane.
High ambient room temperature.| Contact Sears Service to determine cause.
‘Mre disconnected from spark ignitor.| Reconnect wire connector to spark
ignitor.
Broken electrode or electrical wire.| Replace pilot assembly.
Piezo Ignitor generator fails to operate or malfunctions.| Replace Piezo
Ignitor generator.
BURNER WILL NOT STAY LIT| Thermocouple TCO malfunction.| Replace pilot
assembly.
High ambient room temperature.| Contact a service agency to determine cause.
Dirty or clogged air intake screen.| Clean and reinstall air intake screen.
Flame arrestor openings blocked.| Contact Sears Service to determine cause.
Defective Gas Control.| Replace Gas Control.
PILOT OUTAGE| Duty pilot burner.| Clean pilot assembly.
Ditty or clogged air intake screen.| Clean and reinstall air intake screen.
Thermocouple tip is not in contact with pilot flame.| Insert thermocouple
correctly.
Thermocouple malfunction.| Replace pilot assembly.
Thermocouple TCO malfunction.| Replace pilot assembly.
Defective Gas Control.| Replace Gas Control.
NOT ENOUGH HOT WATER| Heater not lit or thermostat not on.| Refer to LIGHTING
INSTRUCTIONS.
Thermostat set too low.| Refer to TEMPERARRE REGULATION.
Heater undersized.| Reduce hot water use.
Low gas pressure.| Contact your gas supplier.
Incoming water is unusually cold.| Allow more time for heater to re-heat.
Leaking hot water pipes or fixtures.| Have plumber check and repair leaks.
High temperature limit switch activated.| Contact Sears Service to determine
cause.
WATER TOO HOT| Thermostat set too high.| Refer to TEMPERATURE REGULATION.
WATER HEATER SOUNDS| Condensation dripping on burner.| Refer toCONDENSAMN.
SIZZLING-RUMBLING-RUMBLING| Sediment or calcium in bottom of heater tank.|
Clean sediment from tank. Refer to DRAINING instructions in Maintenance
section of manual.
SOOTING| Improper combustion.| No adjustment available. Contact Sears Service
to determine cause.
VENT GAS ODORS| I ack of supply sir.| Contact Sears Service to determine
cause.
Improperly installed vent piping.
Downdraft.
Poor combustion.
PARTS ORDER LIST
POWER MISER TM 6 GAS WATER HEATER
MODEL NO”S
153,336160 | 30 Gallon Short |
---|---|
153.336260 | 40 Gallon Short |
153,336300 HA | 30 Gallon High Altitude |
153.336360 | 30 Gallon |
| | Model Numbers
---|---|---
Key No.| Part Description| 153.336160| 153.336260|
153.336300 HA| 153.336360
1| Burner Assembly (Includes items 2-7)| 9003477| 9003485| 9003456| 9003442
2| Burner Head| 9003385| 9003385| 9003385| 9003385
3 “3| Burner Orifice| 9003478 (#38)| 9003443 (#36)| 9003457 (#37)| 9003443
(#36)
4| Burner Tube w/Rubber Boot”| 9003479| 9003468| 9003390| 9003390
5| PilotAssembly w/Grommer| 9003444| 9003444| 9003542| 9003530
6| Inner 000r*| 9003400| 9003398| 9003399| 9003399
7| Inner Door Gasket| 9003401| 9003401| 9003401| 9003401
8| Flue Baffle| 9003480| 9003480| 9003403| 9003403
9| Flue Restrictor| 9003445| 9003445| 9003445| 9003445
10| Draft Hood| 9003405| 9003405| 9003446| 9003446
11| Air Intake Screen| 9003406| 9003406| 9003406| 9003406
12| Inlet Tube| 9003500| 9003500| 9003463| 9003463
13| Gas Control Valve| F145-1278| F145-1278| F145-1278| F145-1278
14| Temperature Adjustment Knob| F145-1280| F145-1280| F145-1280| F145-1280
15| Drain Valve| 9003482| 9003482| 9003448| 9003448
16| Drain Valve Washer| 9001584| 9001584| 9001584| 9001584
17| Outer Door| 9003409| 9003409| 9003409| 9003409
18| Piezo Ignitor w/Bracket| 9003410| 9003410| 9003410| 9003410
19| Anode Rod| 9003483| 9003487| 9003413| 9003413
20| Temperature-Pressure Relief Valve| 9003484| 9003484| 9000071| 9000071
21| Viewport Assembly| 9003414| 9003414| 9003414| 9003414
22| Instruction Manual| 184482-000| 184482-000| 184482-000| 184482-000
*23| Mag-Erad| 23600| 23600| 23600| 23600
- Not Shown.
**Includes Inner Door Gasket
Now that you have purchased your gas water heater, should a need ever exist
for repair parts or service, simply contact any Sears Service Center or call
1-800-4-MY-HOME (1-800-469-4663). Be
sure to provide all pertinent facts when you call or visit.
All parts listed may be ordered from any Sears Service Center and by calling t
-800-366-PART (1-800-366-7278). If the
parts you need are not stocked locally, your order will be electronically
transmitted to a SEARS Repair Parts Distribution Center for handling.
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION:
- MODELNUMBER
- SERIAL NUMBER
- TYPE GAS- NATURAL OR PROPANE (L.Ft)
- PARTDESCPJPTION
THIS IS A REPAIR PARTS LIST, NOT A PACKING LIST.
POWER MISER TM 6 GAS WATER HEATER
MODEL NO”S
153.336400 HA | 40 Gallon High Altitude |
---|---|
153.336464 | 40 Gallon |
153.336500 HA | 50 Gallon High Altitude |
153.336360 | 50 Gallon |
| | Model Numbers
---|---|---
Key No.| Part Description| 153.336400 HA| 153.336464|
153.336500 HA| 153.336560
1| Burner Assembly (Includes items 2-7)| 9003461| 9003458| 9003474| 9003467
2| Burner Head*| 9003385| 9003385| 9003385| 9003385
3| Burner Orifice’| 9003457(#37)| 9003443(#36)| 9003457(#37)| 9003443(#36)
4| Burner Tube w/Rubber Boot”| 9003391| 9003391| 9003468| 9003468
5| Pilot Assembly w/Grommer| 9003531| 9003459| 9003542| 9003530
6| Inner Door| 9003400| 9003400| 9003398| 9003398
7| Inner Door Gasket| 9003401| 9003401| 9003401| 9003401
8| Flue Baffle| 9003403| 9003403| 9003403| 9003403
9| Flue Restrictor| 9003445| 9003445| 9003445| 9003445
10| Draft Hood| 9003446| 9003446| 9003446| 9003446
11| Air Intake Screen| 9003406| 9003406| 9003406| 9003406
12| Inlet Tube| 9003463| 9003463| 9003473| 9003473
13| Gas Control Valve| F145-1278| F145-1278| F145-1278| F145-1278
14| Temperature Adjustment Knob| F145-1280| F145-1280| F145-1280| F145-1280
15| Drain Valve| 9003448| 9003448| 9003448| 9003448
16| Drain Valve Washer| 9001584| 9001584| 9001584| 9001584
17| Outer Door| 9003409| 9003409| 9003409| 9003409
18| Piezo Ignitor w/Bracket| 9003410| 9003410| 9003410| 9003410
19| Anode Rod| 9003413| 9003413| 9003465| 9003465
20| Temperature-Pressure Relief Valve| 9000071| 9000071| 9003466| 9003466
21| Viewport Assembly| 9003414| 9003414| 9003414| 9003414
22| Instruction Manual| 184482-000| 184482-000| 184482-000| 184482-000
*23| Mag-Erad| 23600| 23600| 23600| 23600
- Not Shown.
** Includes Inner Door Gasket
Now that you have purchased your gas water heater, should a need ever exist
for repair parts or service, simply contact any Sears Service Center or call
1-800-4-MY-HOME (1-800-469-4663). Be
sure to provide all pertinent facts when you call or visit.
All parts listed may be ordered from any Sears Service Center and by calling
1-800-366-PART (1-800-366-7278). If the
parts you need are not stocked locally, your order will be electronically
transmitted to a SEARS Repair Parts Distribution Center for handling.
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION:
- MODEL NUMBER
- SERIAL NUMBER
- TYPE GAS- NATURAL OR PROPANE (L.Ft)
- PART DESCPJPTION
THIS IS A REPAIR PARTS LIST, NOT A PACKING LIST.
POWER MISER™ 6 GAS WATER HEATER
MODEL NO”S
153.336760 | 30 Gallon Propane (L,E) |
---|---|
153,336800 HA | 40 Gallon Propane (LE) High Altitude |
153.336860 | 40 Gallon Propane (L,P.) |
153,336900 HA | 50 Gallon Propane (LP,) High Altitude |
153.336960 | 50 Gallon Propane (L,P.) |
| | Model Numbers
---|---|---
Ke No. Part Description| 153.336760| 153.336800|
153.336860| 153.336900| 153.336960
1 Burner Assembly (Includes items 2-7)| 9003451| 9003462| 9003460| 9003475|
9003470
2 Burner Head| 9003422| 9003422| 9003422| 9003422| 9003422
3 Burner Orifice| 9003453(#51)| 9003532(#52)| 9003453(#51)| 9003532(#52)|
9003453(#51
4 Burner Tube w/Rubber Boor| 9003454| 9003392| 9003392| 9003476| 9003471
5 PilotAssembly w/Grommet| 9003455| 9003455| 9003455| 9003472| 9003472
6 Inner Door| 9003399| 9003400| 9003-400| I 9003398| 9003398
7 Inner Door Gasket| 9003401| 9003401| 9003401| 9003401| 9003401
8 Flue Baffle| 9003403| 9003403| 9003403| 9003403| 9003403
9 Flue Restrictor| 9003445| 9003445| 9003445| 9003445| 9003445
10 Draft Hood| 9003446| 9003446| 9003446| 9003446| 9003446
11 Air Intake Screen| 9003406| 9003406| 9003406| 9003406| 9003406
12 Inlet Tube| 9003463| 9003463| 9003463| 9003473| 9003473
13 Gas Control Valve| F145-1279| F145-1279| F145-1279| F145-1279| F145-1279
14 Temperature Adjustment Knob| F145-1280.| F145-1280| F145-1280| F145-1280|
F145-1280
15 Drain Valve| 9003448| 9003448| 9003448| 9003448| 9003448
16 Drain Valve Washer| 9001584| 9001584| 9001584| 9001584| E 9001584
17 Outer Door| 9003409| 9003409| 9003409| 9003409| 9003409
18. Piezo Ignitor w/Bracket| 9003410| 9003410| 9003410| 9003410| ; 9003410
19 Anode Rod| 9003413| 9003413| 9003413| 9003465| 9003465
20 Temperature-Pressure Relief Valve| 9000071| 9000071| 9000071| 9003466|
19003466
21 Viewport Assembly| 9003414| 9003414| 9003414| 9003414| l9003414
22 Instruction Manual| 184482000| 184482-000| 184482000| 184482000| 184482-000 .
*23 Mag-Erad| 23600| 23600| 23600| 23600| 23600 1
- Not Shown.
** Includes InnerDoor Gasket
Now that you have purchased your gas water heater, should a need ever exist
for repair parts or service, simply contact any Sears Service Center or call
1-8O0-4-MY-HOME (1-800-469-4663). Be
sure to provide all pertinent facts when you call or visit.
All parts listed may be ordered from any Sears Service Center and by calling
1-800-366-PART (1-800-366-7278). If the
parts you need are not stocked locally, your order will be electronically
transmitted to a SEARS Repair Parts Distribution Center for handling.
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION:
- MODEL NUMBER
- SERIAL NUMBER
- TYPEGAS-NATURALOR PROPANE(L.R)
- PART DESCRPTION
THIS ISA REPAIR PARTS LIST, NOTA PACKING LIST.
FULLONEYEARWARRANTYONWATERHEATER
For oneyear from the date of purchase, when yourSears Kenmore water heater is
installed and operated in a single-family residence in accordance with the
instructions in this manual, Sears will:
- Repair defects in material or workmanship in this water heater, free of charge.
- Furnish and install a new current model water heater of equal capacity and quality, free of charge, if a leak occurs in the tank.
LIMITED WARRANTY ON TANKS THAT LEAK
After one year and through 6 years from date of purchase for water heaters
used in a single-family residence, if a leak occurs in the tank, Sears will
furnish a new current model water heater of equal capacity and quality. You
will be charged for any installation.
LIMITED WARRANTY ON PARTS
After one year and through 6 years from the date of purchase, when your Sears
Kenmore water heater is used in a single-family residence and is installed and
operated inaccordance with theinformation inthis manual, if a part fails due
to materials or workmanship, Sears will furnish a replacement free of charge.
Youwill be charged for labor.
If the water heater is subject to commercial, institutional, industrial or use
in residences of two families or more, the above warranty coverage for tanks
that leak is effective for 2 years from the date of purchase and the above
parts warranty is effective for I year from the date of purchase.
To obtainwarranty service, SIMPLY CALL 1-800-4-MY-
HOME®(1-800-469-4663). This warranty
applies only while this product is in use in the United States.
This warranty gives you specific legal rights and you may also have other
rights which vary from state to state.
Sears, Roebuck and CO, Dept 817 WA, Hoffman Estates, IL 60179
The price of your water heater does not include a free checkup service call.
On water heater installations arranged by Sears, Sears warrants the
installation.
A charge will be made on service calls due to poor or incomplete installation.
These include:
a. Adjusting thermostat
b. Lighting pilot
c. Leaks in pipes or fittings
d. Improper venting
e. Condensation
MASTER PROTECTION AGREEMENTS
Congratulations on making a smart purchase. Your new Kenmore® product is
designed and manufactured for years of dependable operation.
But like all products, it may require preventive maintenance or repair from
time to time. That’s when having a Master Protection Agreement can save you
money and aggravation.
Purchase a Master Protection Agreement now and protect yourself from
unexpected hassle and expense.
The Master Protection Agreement also helps extend the life of your new
product. Here’s what’s included in the Agreement:
- Expert Service by our 12,000 professional repair specialist.
- Unlimited service and nocharge for partsand laboron all covered repairs.
- “No-lemon” guarantee – replacement of your covered productif four or more product failures occur within twelve months.
- Product replacement if your covered productcan’t be fixed.
- Annual Preventive Maintenance Check at your request – no extra charge.
- Fast help by phone- phone support from a Sears technician on products requiring in-homerepair, plus convenient repair scheduling.
- Power surge protection against electrical damage due to power fluctuations.
- Rental reimbursement if repair of your covered product takes longer than promised.
Once you purchasethe Agreement, a simple phone call is all that ittakes for
you to schedule service. You can call anytime day or night, or schedule a
service appointment on-line.
Sears has over 12,000 professional repair specialists, who have access to over
4.5 million quality parts and accessories. That’s the kind of professionalism
you can count on to help prolong the life of your new purchase foryears to
come. Purchase your Master ProtectionAgreement today!
Some limitations and exclusions apply. For prices and additional information
call 1-800-827-6655.
SEARS INSTALLATION SERVICE
For Sears professional Installationof home appliances, garage door openers,
water heaters, and othermajor home items,inthe U.S.A., call 1-80O-4-MY-HOME®.
For in-home major brand repair service
Call 24 hours a day, 7 days a week (U.S.A. and Canada)
1-800-4-MY-HOME®
(1-800-469-4663)
www.sears.com
The model number of yourwater heateris found on the model rating plate on the
front of the water heater.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A