heat wagon VG750 Portable and Construction Heaters Instruction Manual

June 16, 2024
Heat Wagon

heat wagon VG750 Portable and Construction Heaters

Product Information

Specifications

  • Model: VG750-VG1100 Construction Heater
  • Address: 342 N. Co. Rd. 400 East Valparaiso, IN 46383
  • Certification: C US
  • Revision: 12-23

Important Information

The VG750-VG1100 Construction Heater is designed for temporary heating of buildings under construction, alteration, or repair, as well as providing emergency heat. It is important to note the following:

  • This heater is not intended for use in pest remediation.
  • The primary purpose of the heater is to provide safe and economical heating.
  • The products of combustion are vented outside the area being heated.
  • The heater is not designed as an Unvented Gas Fired Room Heater and should not be used in homes.
  • The installation or storage of LP-gas containers, even temporarily, inside any recreational vehicle is prohibited.
  • The use of Unvented Heaters in recreational vehicles is also prohibited.
  • The use of the heater must be in accordance with ANSI Z83.7a-2000, NFPA-58, and all governing state and local codes.

Caution

Do not use this heater in a space where gasoline or other liquids having flammable vapors are stored or used. Failure to comply with this caution can result in hazards of fire, explosion, burn, asphyxiation, carbon monoxide poisoning, and/or electrical shock.

General Hazard Warning

Failure to comply with the precautions and instructions provided with this heater can result in death, serious bodily injury, and property loss or damage. Only persons who can understand and follow the instructions should use or service this heater.

Warranty

This heater is guaranteed against defective materials and workmanship for one (1) year from Heat Wagon invoice date.

Product Usage Instructions

Installation

  1. Choose a suitable location for the heater, ensuring it is not placed in a space where gasoline or other flammable liquids are stored.
  2. Follow the installation instructions provided in the manual for proper setup and connection of the heater.
  3. Ensure compliance with ANSI Z83.7a-2000, NFPA-58, and all governing state and local codes.

Maintenance

  1. Regularly inspect the heater for any signs of damage or wear.
  2. Clean the heater as recommended in the manual to remove any dust or debris that may affect its performance.
  3. Keep solid combustibles, such as building materials, paper or cardboard, a safe distance away from the heater as recommended by the instructions.

Usage Precautions

  • Never use the heater in spaces that contain volatile or airborne combustibles, such as gasoline, solvents, paint thinner, dust particles, or unknown chemicals.
  • Always follow the recommended safety distances and precautions provided in the manual.
  • If you have any questions or need assistance, contact your local Heat Wagon dealer or the manufacturer.

FAQs

  • Q: Can I use this heater in my home?
    • A: No, this heater is not designed for home use. It is intended for temporary heating of buildings under construction, alteration, or repair.
  • Q: Can I use this heater in a recreational vehicle?
    • A: No, the installation or storage of LP-gas containers, even temporarily, inside any recreational vehicle is prohibited. The use of Unvented Heaters in recreational vehicles is also prohibited.
  • Q: How long is the warranty for this heater?
    • A: This heater is guaranteed against defective materials and workmanship for one (1) year from Heat Wagon invoice date.

342 N. Co. Rd. 400 East Valparaiso, IN 46383
888-432-8924 · Fax 219-462-7985 www.heatwagon.com

Installation and Maintenance

Manual
Please retain this manual for future reference.

VG750 VG1100
Construction Heater

C

US

Revision 12-23

CAUTION: Do not use this heater in a space where gasoline or other liquids having flammable vapors are stored.

IMPORTANT INFORMATION! READ FIRST
The heater is designed for use as a construction heater under ANSI Z83.7a-2000. Heater is not intended for use in pest remediation. The primary purpose of construction heaters is to provide temporary heating of buildings under construction, alteration, or repair and to provide emergency heat. Properly used, the heater provides safe, economical heating. Products of combustion are vented outside the area being heated.
The heater IS NOT designed as an Unvented Gas Fired Room Heater under ANSI-Z21.11.2 and SHOULD NOT be used in the home.
ANSI A119.2(NFPA 501C)-1987 Recreational Vehicle Standard prohibits the installation or storage of LP-gas containers even temporarily inside any recreational vehicle. The standard also prohibits the use of Unvented Heaters in such vehicles.
NFPA-58 1989 STANDARD FOR THE STORAGE AND HANDLING OF LIQUEFIED PETROLEUM GASES
Use of the heater must be in accordance with this Standard and in compliance with all governing state and local codes. Storage and handling of propane gas and propane cylinders must be in accordance with NFPA 58 and all local governing codes.
We cannot anticipate every use which may be made for our heaters. CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT LOCAL REGULATIONS.
Other standards govern the use of fuel gases and heat producing products in specific applications. Your local authority can advise you about these.
CAUTION
DO NOT USE THIS HEATER IN A SPACE WHERE GASOLINE OR OTHER LIQUIDS HAVING FLAMMABLE VAPORS ARE STORED OR USED.
CONSTRUCTION HEATER GENERAL HAZARD WARNING:
Failure to comply with the precautions and instructions provided with this heater, can result in death, serious bodily injury and property loss or damage from hazards of fire, explosion, burn, asphyxiation, carbon monoxide poisoning, and/or electrical shock.
Only persons who can understand and follow the instructions should use or service this heater.
If you need assistance or heater information such as an instruction manual, labels, etc., contact your local Heat Wagon dealer or the manufacturer.
WARNING
Fire, burn, inhalation, and explosion hazard. Keep solid combustibles, such as building materials, paper or cardboard, a safe distance away from the heater as recommended by the instructions. Never use the heater in spaces which do or may contain volatile or airborne combustibles, or products such as gasoline, solvents, paint thinner, dust particles or unknown chemicals.
Not for home or recreational vehicle use! If you have read this entire manual and you still have questions,
please call us at 219-464-8818
1

Installation and Maintenance Manual
Model VG750-VG1100 Construction Heater

WARRANTY

This heater is guaranteed against defective materials and workmanship for one (1) year from Heat Wagon invoice date.
Warranty repairs may be made only by an authorized, trained and certified Heat Wagon dealer. Warranty repairs by other entities will not be considered. Warranty claims must include model number and serial number. Components are guaranteed to the extent of the component manufacturer’s warranty.
LIMITATIONS
Warranty claims for service parts (wear parts) such as spark plugs, igniters, and flame rods will not be allowed. Diagnostic parts such as voltage meters and pressure gauges are not warrantable. Evidence of improper fuel usage, fuel pressures outside of manufacturer’s specification, poor fuel quality, improper electric power, misapplication and/or evidence of abuse may be cause for rejection of warranty claims.
Labor, travel time, mileage and shipping charges will not be allowed. Minor adjustments to heaters are the responsibility of the dealer. Defective parts must be tagged and held for possible return to the factory for 60 days from date of repair. The factory will provide a return goods authorization, (RGA) for defective parts to be returned. No warranty will be allowed for parts not purchased from Heat Wagon.

342 N. Co. Rd. 400 East · Valparaiso, IN 46383

219-464-8818 · 888-432-8924 · Fax 800-255-7985

www.heatwagon.com

2

3

4

5

6

– VG750 – T30359-2 VG1100 – T30360-1
– VG750 – T30125 VG1100 – T30124

– VG750 – T30125 VG1100 – T30124

– VG750 – T30123

a

VG1100 – T30123

– VG750 – T30123 VG1100 – T30123

– T30361

f

VAPOR PROPANE QUICK REFERENCE HOSE CHART

Hose

BTU

Length 1 Million

in Feet 1/2PSI 10PSI 10 1-1/4 3/4

25 1-1/4 3/4

35 1-1/2 3/4

50 1-1/2 3/4

75 2 3/4

100 2 3/4

125 2 3/4

150 2 3/4

175 2 3/4

200 2 3/4

225 2 3/4

Hose

BTU

Length

1 Million

in Feet <1PSI 1PSI 2PSI 5PSI 10 1-1/2 1-1/4 3/4 3/4

25 2 1-1/4 3/4 3/4

NATURAL GAS QUICK

35 50

2 1-1/4 3/4 3/4 2 1-1/4 1 3/4

REFERENCE HOSE CHART

75 2 1-1/4 1-1/4 3/4 100 2 1-1/4 1-1/4 3/4 125 2-1/2 1-1/2 1-1/4 1

150 2-1/2 1-1/2 1-1/4 1

175 2-1/2 1-1/2 1-1/4 1

200 2-1/2 1-1/2 1-1/4 1-1/4

225 2-1/2 1-1/2 1-1/4 1-1/4

7

8

9

10

11

See page 47 for additional details
12

13

14

15

16

17

VG750 PARTS BREAKDOWn
18

VG750 PARTS BREAKDOWn
19

VG750 PARTS BREAKDOWn
20

VG1100 PARTS BREAKDOWn
21

VG1100 PARTS BREAKDOWn
22

VG1100 PARTS BREAKDOWn
23

24

25

26

VG750
27

(See page 7 for actual manifold assembly)

VG750

  • (field supplied) (T30361) (field supplied)

T30125 (T30123)

(T30123)

(Gas Selector – T30359-2) (gauge installed)

  • If max 14″ W.C. gas supply exceeded recommend 11SV08 regulator.

10″ wc

28

VG750
29

VG750
30

VG750
31

VG750
32

VG750
33

VG750
34

VG750
35

VG750
36

VG750
37

VG750
38

VG750
39

VG750
40

VG750
41

VG1100
42

VG1100
43

VG1100
44

VG1100
45

VG1100
46

VG1100
47

VG1100
48

VG1100
49

VG1100
50

VG1100
51

VG1100
52

EXHAUST FLUE PIPE GUIDELINES
CAPACITY OF TYPE B DOUBLEWALL VENTS SERVING A SINGLE DRAFT HOOD-HEATER x 1000 BTU’S FOR INDOOR APPLICATIONS
53

52

342 N. Co. Rd. 400 East Valparaiso, IN 46383
219-464-8818 · Fax 219-462-7985 www.heatwagon.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals