heat wagon VG750 Portable and Construction Heaters Instruction Manual
- June 16, 2024
- Heat Wagon
Table of Contents
heat wagon VG750 Portable and Construction Heaters
Product Information
Specifications
- Model: VG750-VG1100 Construction Heater
- Address: 342 N. Co. Rd. 400 East Valparaiso, IN 46383
- Certification: C US
- Revision: 12-23
Important Information
The VG750-VG1100 Construction Heater is designed for temporary heating of buildings under construction, alteration, or repair, as well as providing emergency heat. It is important to note the following:
- This heater is not intended for use in pest remediation.
- The primary purpose of the heater is to provide safe and economical heating.
- The products of combustion are vented outside the area being heated.
- The heater is not designed as an Unvented Gas Fired Room Heater and should not be used in homes.
- The installation or storage of LP-gas containers, even temporarily, inside any recreational vehicle is prohibited.
- The use of Unvented Heaters in recreational vehicles is also prohibited.
- The use of the heater must be in accordance with ANSI Z83.7a-2000, NFPA-58, and all governing state and local codes.
Caution
Do not use this heater in a space where gasoline or other liquids having flammable vapors are stored or used. Failure to comply with this caution can result in hazards of fire, explosion, burn, asphyxiation, carbon monoxide poisoning, and/or electrical shock.
General Hazard Warning
Failure to comply with the precautions and instructions provided with this heater can result in death, serious bodily injury, and property loss or damage. Only persons who can understand and follow the instructions should use or service this heater.
Warranty
This heater is guaranteed against defective materials and workmanship for one (1) year from Heat Wagon invoice date.
Product Usage Instructions
Installation
- Choose a suitable location for the heater, ensuring it is not placed in a space where gasoline or other flammable liquids are stored.
- Follow the installation instructions provided in the manual for proper setup and connection of the heater.
- Ensure compliance with ANSI Z83.7a-2000, NFPA-58, and all governing state and local codes.
Maintenance
- Regularly inspect the heater for any signs of damage or wear.
- Clean the heater as recommended in the manual to remove any dust or debris that may affect its performance.
- Keep solid combustibles, such as building materials, paper or cardboard, a safe distance away from the heater as recommended by the instructions.
Usage Precautions
- Never use the heater in spaces that contain volatile or airborne combustibles, such as gasoline, solvents, paint thinner, dust particles, or unknown chemicals.
- Always follow the recommended safety distances and precautions provided in the manual.
- If you have any questions or need assistance, contact your local Heat Wagon dealer or the manufacturer.
FAQs
- Q: Can I use this heater in my home?
- A: No, this heater is not designed for home use. It is intended for temporary heating of buildings under construction, alteration, or repair.
- Q: Can I use this heater in a recreational vehicle?
- A: No, the installation or storage of LP-gas containers, even temporarily, inside any recreational vehicle is prohibited. The use of Unvented Heaters in recreational vehicles is also prohibited.
- Q: How long is the warranty for this heater?
- A: This heater is guaranteed against defective materials and workmanship for one (1) year from Heat Wagon invoice date.
342 N. Co. Rd. 400 East Valparaiso, IN 46383
888-432-8924 · Fax
219-462-7985 www.heatwagon.com
Installation and Maintenance
Manual
Please retain this manual for future reference.
VG750 VG1100
Construction Heater
C
US
Revision 12-23
CAUTION: Do not use this heater in a space where gasoline or other liquids having flammable vapors are stored.
IMPORTANT INFORMATION! READ FIRST
The heater is designed for use as a construction heater under ANSI
Z83.7a-2000. Heater is not intended for use in pest remediation. The primary
purpose of construction heaters is to provide temporary heating of buildings
under construction, alteration, or repair and to provide emergency heat.
Properly used, the heater provides safe, economical heating. Products of
combustion are vented outside the area being heated.
The heater IS NOT designed as an Unvented Gas Fired Room Heater under
ANSI-Z21.11.2 and SHOULD NOT be used in the home.
ANSI A119.2(NFPA 501C)-1987 Recreational Vehicle Standard prohibits the
installation or storage of LP-gas containers even temporarily inside any
recreational vehicle. The standard also prohibits the use of Unvented Heaters
in such vehicles.
NFPA-58 1989 STANDARD FOR THE STORAGE AND HANDLING OF LIQUEFIED PETROLEUM
GASES
Use of the heater must be in accordance with this Standard and in compliance
with all governing state and local codes. Storage and handling of propane gas
and propane cylinders must be in accordance with NFPA 58 and all local
governing codes.
We cannot anticipate every use which may be made for our heaters. CHECK WITH
YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT LOCAL
REGULATIONS.
Other standards govern the use of fuel gases and heat producing products in
specific applications. Your local authority can advise you about these.
CAUTION
DO NOT USE THIS HEATER IN A SPACE WHERE GASOLINE OR OTHER LIQUIDS HAVING
FLAMMABLE VAPORS ARE STORED OR USED.
CONSTRUCTION HEATER GENERAL HAZARD WARNING:
Failure to comply with the precautions and instructions provided with this
heater, can result in death, serious bodily injury and property loss or damage
from hazards of fire, explosion, burn, asphyxiation, carbon monoxide
poisoning, and/or electrical shock.
Only persons who can understand and follow the instructions should use or
service this heater.
If you need assistance or heater information such as an instruction manual,
labels, etc., contact your local Heat Wagon dealer or the manufacturer.
WARNING
Fire, burn, inhalation, and explosion hazard. Keep solid combustibles, such as
building materials, paper or cardboard, a safe distance away from the heater
as recommended by the instructions. Never use the heater in spaces which do or
may contain volatile or airborne combustibles, or products such as gasoline,
solvents, paint thinner, dust particles or unknown chemicals.
Not for home or recreational vehicle use! If you have read this entire manual
and you still have questions,
please call us at 219-464-8818
1
Installation and Maintenance Manual
Model VG750-VG1100 Construction Heater
WARRANTY
This heater is guaranteed against defective materials and workmanship for one
(1) year from Heat Wagon invoice date.
Warranty repairs may be made only by an authorized, trained and certified Heat
Wagon dealer. Warranty repairs by other entities will not be considered.
Warranty claims must include model number and serial number. Components are
guaranteed to the extent of the component manufacturer’s warranty.
LIMITATIONS
Warranty claims for service parts (wear parts) such as spark plugs, igniters,
and flame rods will not be allowed. Diagnostic parts such as voltage meters
and pressure gauges are not warrantable. Evidence of improper fuel usage, fuel
pressures outside of manufacturer’s specification, poor fuel quality, improper
electric power, misapplication and/or evidence of abuse may be cause for
rejection of warranty claims.
Labor, travel time, mileage and shipping charges will not be allowed. Minor
adjustments to heaters are the responsibility of the dealer. Defective parts
must be tagged and held for possible return to the factory for 60 days from
date of repair. The factory will provide a return goods authorization, (RGA)
for defective parts to be returned. No warranty will be allowed for parts not
purchased from Heat Wagon.
342 N. Co. Rd. 400 East · Valparaiso, IN 46383
219-464-8818 · 888-432-8924 · Fax 800-255-7985
2
3
4
5
6
– VG750 – T30359-2 VG1100 – T30360-1
– VG750 – T30125 VG1100 – T30124
– VG750 – T30125 VG1100 – T30124
– VG750 – T30123
a
VG1100 – T30123
– VG750 – T30123 VG1100 – T30123
– T30361
f
VAPOR PROPANE QUICK REFERENCE HOSE CHART
Hose
BTU
Length 1 Million
in Feet 1/2PSI 10PSI 10 1-1/4 3/4
25 1-1/4 3/4
35 1-1/2 3/4
50 1-1/2 3/4
75 2 3/4
100 2 3/4
125 2 3/4
150 2 3/4
175 2 3/4
200 2 3/4
225 2 3/4
Hose
BTU
Length
1 Million
in Feet <1PSI 1PSI 2PSI 5PSI 10 1-1/2 1-1/4 3/4 3/4
25 2 1-1/4 3/4 3/4
NATURAL GAS QUICK
35 50
2 1-1/4 3/4 3/4 2 1-1/4 1 3/4
REFERENCE HOSE CHART
75 2 1-1/4 1-1/4 3/4 100 2 1-1/4 1-1/4 3/4 125 2-1/2 1-1/2 1-1/4 1
150 2-1/2 1-1/2 1-1/4 1
175 2-1/2 1-1/2 1-1/4 1
200 2-1/2 1-1/2 1-1/4 1-1/4
225 2-1/2 1-1/2 1-1/4 1-1/4
7
8
9
10
11
See page 47 for additional details
12
13
14
15
16
17
VG750 PARTS BREAKDOWn
18
VG750 PARTS BREAKDOWn
19
VG750 PARTS BREAKDOWn
20
VG1100 PARTS BREAKDOWn
21
VG1100 PARTS BREAKDOWn
22
VG1100 PARTS BREAKDOWn
23
24
25
26
VG750
27
(See page 7 for actual manifold assembly)
VG750
- (field supplied) (T30361) (field supplied)
T30125 (T30123)
(T30123)
(Gas Selector – T30359-2) (gauge installed)
- If max 14″ W.C. gas supply exceeded recommend 11SV08 regulator.
10″ wc
28
VG750
29
VG750
30
VG750
31
VG750
32
VG750
33
VG750
34
VG750
35
VG750
36
VG750
37
VG750
38
VG750
39
VG750
40
VG750
41
VG1100
42
VG1100
43
VG1100
44
VG1100
45
VG1100
46
VG1100
47
VG1100
48
VG1100
49
VG1100
50
VG1100
51
VG1100
52
EXHAUST FLUE PIPE GUIDELINES
CAPACITY OF TYPE B DOUBLEWALL VENTS SERVING A SINGLE DRAFT HOOD-HEATER x 1000
BTU’S FOR INDOOR APPLICATIONS
53
52
342 N. Co. Rd. 400 East Valparaiso, IN 46383
219-464-8818 · Fax
219-462-7985
www.heatwagon.com