ONAN HGJAA RV Generators Instruction Manual
- June 16, 2024
- ONAN
Table of Contents
Mobile GenSet
Operator’s Manual
HGJAA, HGJAB, HGJAC
HGJAA RV Generators
WARNING:
The engine exhaust from this product contains chemicals known to the State of
California to cause cancer, birth defects or other reproductive harm.
WARNING:
Do not use this genset on a boat Such use may violate U. S. Coast Guard
regulations and can result in severe personal injury or death from fire,
electrocution, or carbon monoxide poisoning
Safety Precautions
Thoroughly read the OPERATOR’S MANUAL before operating the genset. Safe
operation and top performance can only be obtained when equipment is operated
and maintained properly.
The following symbols in this manual alert you to po- tential hazards to the
operator, service person and equipment.
DANGER alerts you to an immediate hazard which will result in severe personal injury or death.
WARNING alerts you to a hazard or unsafe practice which can result in severe personal injury or death.
CAUTION alerts you to a hazard or unsafe practice which can result in personal injury or equipment damage.
Electricity, fuel, exhaust, moving parts and batteries present hazards which can result in severe personal injury or death.
GENERAL PRECAUTIONS
-
Keep ABC fire extinguishers handy.
-
Keep children away from the genset.
-
Make sure all fasteners are secure and torqued properly.
-
Keep the genset and its compartment clean.
Excess oil and oily rags can catch fire. Dirt and gear stowed in the compartment can restrict cooling air. -
Before working on the genset, disconnect the negative (–) battery cable at the battery to prevent accidental starting.
-
Use caution when making adjustments while the genset is running—hot, moving or electrically live parts can cause severe personal injury or death.
-
Used engine oil has been identified by some state and federal agencies as causing cancer or reproductive toxicity. Do not ingest, inhale, or contact used oil or its vapors.
-
Benzene and lead in some gasolines have been identified by some state and federal agencies as causing cancer or reproductive toxicity. Do not to ingest, inhale or contact gasoline or its vapors.
-
Do not work on the genset when mentally or physically fatigued or after consuming alcohol or drugs.
-
Carefully follow all applicable local, state and federal codes.
GENERATOR VOLTAGE IS DEADLY!
-
Generator output connections must be made by a qualified electrician in accordance with applicable codes.
-
The genset must not be connected to the public utility or any other source of electrical power.
Connection could lead to electrocution of utility personnel and damage to equipment. An approved switching device must be used to prevent interconnections. -
Use caution when working on live electrical equipment. Remove jewelry, make sure clothing and shoes are dry and stand on a dry wooden platform.
ENGINE EXHAUST IS DEADLY!
-
Learn the symptoms of carbon monoxide poisoning in this manual and never sleep in the vehicle while the genset is running unless the vehicle is equipped with a working carbon monoxide detector.
-
The exhaust system must be installed in accordance with the genset Installation Manual.
Engine cooling air must not be used for heating the working or living space or compartment. -
Inspect for exhaust leaks at every startup and after every eight hours of running.
-
Make sure there is ample fresh air when operating the genset in a confined area.
FUEL IS FLAMMABLE AND EXPLOSIVE
- Do not smoke or turn electrical switches ON or OFF where fuel fumes are present or in areas sharing ventilation with fuel tanks or equipment. Keep flame, sparks, pilot lights, arc-producing equipment and all other sources of ignition well away.
- Fuel lines must be secured, free of leaks and separated or shielded from electrical wiring.
- Leaks can lead to explosive accumulations of gas. Natural gas rises when released and can accumulate under hoods and inside housings and buildings. LPG sinks when released and can accumulate inside housings and basements and other below-grade spaces. Prevent leaks and the accumulation of gas.
BATTERY GAS IS EXPLOSIVE
- Wear safety glasses and do not smoke while servicing batteries.
- When disconnecting or reconnecting battery cables, always disconnect the negative (–) battery cable first and reconnect it last to reduce arcing.
MOVING PARTS CAN CAUSE SEVERE PERSONAL INJURY OR DEATH
- Do not wear loose clothing or jewelry near moving parts such as PTO shafts, fans, belts and pulleys.
- Keep hands away from moving parts.
- Keep guards in place over fans, belts, pulleys, etc.
Introduction
ABOUT THIS MANUAL
This manual covers the operation and maintenance of the HGJAA, HGJAB and
HGJAC Series of gener- ator sets (gensets). Each operator should study this
manual carefully and observe all of its instructions and safety precautions.
Keep this manual and the Installation Manual with the other vehicle manuals.
Operation, Periodic Maintenance and Trouble- shooting provide the instructions
necessary for operating the genset and maintaining it at top per- formance.
The owner is responsible for performing maintenance in accordance with the
PERIODIC MAINTENANCE SCHEDULE (Page 15). This man- ual also includes genset
specifications, information on how to obtain service, and information for
Califor- nia users.
WARNING This genset is not a life support sys- tem. It can stop without
warning. Children, per- sons with physical or mental limitations, and pets
could suffer personal injury or death. A per- sonal attendant, redundant power
or an alarm system must be used if genset operation is criti- cal.
NAMEPLATE
Model and Serial Numbers: Have the model and serial numbers handy (gray boxes, Figure 1) when contacting an Onan dealer for parts, service or prod- uct information. Each character is significant. (The last character of the model number is the specification letter, which is important for obtaining the right parts.) Record these numbers in the boxes in Fig- ure 1 so that they are handy when you need them.
Genuine Onan replacement parts are recom-mended for best performance and safety.
Federal Emissions Compliance Period: The Federal Emissions Compliance Period referred to on the nameplate indicates the number of operating hours for which the engine has been shown to meet Federal emissions requirements. Category C = 250 hrs, B = 500 hrs, A = 1000 hrs.
FIGURE 1. TYPICAL NAMEPLATE
TYPICAL GENSET
Figure 2 illustrates a typical self-enclosed genset with the maintenance
access cover removed.
Removing the access cover: Pull the top of the cover outward and lift it away.
Securing the access cover: Catch the bottom lip of the cover on the top edge
of the base tray and firmly push it into place.
If the cover pins and rubber grommets do not line up, check that the edging on
the top edge of the base tray lies flat and is pushed down all the way.
If the cover feels loose, one of the rubber grommets probably pushed through.
If so, remove the cover, insert the grommet back into its hole and try again.
CAUTION Operating the genset with the access cover off can lead to
overheating of components. Always secure the cover after starting the genset.
FIGURE 2. TYPICAL SELF-ENCLOSED GENSET
FUEL RECOMMENDATIONS
WARNING Gasoline and LPG are highly flammable and explosive and can cause severe personal injury or death. Do not smoke or turn electrical switches ON or OFF where fuel fumes, tanks or equipment are present or in areas sharing ventilation. Keep flames, sparks, pilot lights, arc-producing equipment and switches and all other sources of ignition well away. Keep a type ABC fire extinguisher in the vehicle.
Gasoline Models
Use clean, fresh unleaded gasoline having a minimum octane rating (Anti-Knock
Index) of 87.
CAUTION Do not use gasoline or gasoline additives containing methanol
because methanol can be corrosive to fuel system components.
Avoid using leaded gasoline because of the extra engine maintenance that will
be required.
LPG Models
Use clean, fresh HD-5 grade liquified petroleum gas (LPG) or equivalent
product consisting of at least 90 percent propane. Commercial liquified
petroleum gas fuels may contain more than 2.5 percent butane which can result
in poor fuel vaporization and poor engine starting in low ambient temperatures
(below 32° F (0° C).
Satisfactory performance on low-pressure LPG models requires that the LPG vapor be supplied at a pressure within the range indicated in Specifications.
WARNING High LPG supply pressure can cause gas leaks which can lead to fire and severe personal injury or death. LPG supply pressure must be adjusted to Specifications by trained and experienced personnel.
ENGINE OIL RECOMMENDATIONS
Use API (American Petroleum Institute) perfor- mance Class SJ, SH or SG engine
oil, which may be in combination with performance Class CH-4, CG-4 or CF-4
(for example: SJ/CH-4). Also look for the SAE (Society of Automotive
Engineers) viscosity grade. Referring to Table 1, choose the viscosity grade
appropriate for the ambient temperatures expected until the next scheduled oil
change.
Single-grade SAE 30 oil is preferable when temper- atures are consistently
above freezing. Multigrade oils are better when wide temperature variations
are expected.
TABLE 1. OIL VISCOSITY VS. TEMPERATURE
EXPECTED AMBIENT TEMPERATURES | SAE VISCOSITY GRADE |
---|---|
32° F (0° C) and higher | 30 |
10° F to 100° F (–12° C to 38° C) | 15W-40 (OnaMaxTM) |
0° F to 80° F (–18° C to 27° C) | 10W-30 |
10W-40
–20° F to 50° F (–28° C to 10° C)| 5W-30
STARTING BATTERIES
The genset has a 12 volt, direct current (DC) engine cranking and control system. See Specifications (Page 29) regarding minimum battery ratings for reliable genset cranking, especially in cold weather. Also see PERIODIC MAINTENANCE SCHEDULE (Page 15) and the battery manufacturer’s instructions regarding battery maintenance. Reliable gen- set starting and starter service life depend upon adequate battery system capacity and proper maintenance.
GENSET CONTROL PANEL
The genset control panel (Figure 3) is located behind the maintenance access
cover (Figure 2) and has the following features:
Control Switch – This switch is used to prime the fuel system, start and
stop the genset and display the fault code. Hold the switch in its START
position to crank and start the genset. Press the switch to its STOP position
to stop the genset. Hold the switch in its STOP/PRIME position (starts in 2
seconds) to prime the fuel system (gasoline models only). See Troubleshooting
(Page 22) about displaying fault codes.
Status Indicator Light – This light is an LED (light emitting diode) in
the control switch which blinks rapidly during cranking and comes on solid
when the starter disconnects, indicating that the genset is running. If the
genset shuts down abnormally, the light will blink a code to indicate the
cause of the shutdown. See Troubleshooting (Page 22).
Line Circuit Breaker – The line circuit breaker protects the AC power
leads connected to the genset from overloads and equipment short circuits.
REMOTE CONTROL PANEL
The vehicle probably has a control panel inside the vehicle for remote control
of the genset. Onan offers three remote control kits as follows:
- Remote switch with status indicator light only (Figure 4).
- Remote switch with status indicator light and hour meter (Figure 5).
- Remote switch with status indicator light and DC voltmeter (Figure 6).
The hour meter (time totalizing meter) records gen- set operating time in
hours. It cannot be reset. See the PERIODIC MAINTENANCE SCHEDULE (Page 15).
The DC voltmeter indicates whether voltage across the 12 VDC control system
and battery is normal. If the indicator consistently stays above or below the
normal zone, see MAINTAINING THE BATTERY AND BATTERY CONNECTIONS (Page 19).
FIGURE 3. GENSET CONTROL PANEL
FIGURE 4. REMOTE SWITCH
FIGURE 5. REMOTE SWITCH / HOUR METER
FIGURE 6. REMOTE SWITCH / DC VOLTMETER
Operation
WARNING EXHAUST GAS IS DEADLY!
Exhaust gases contain carbon monoxide, an odorless, colorless gas. Carbon
monoxide is poisonous and can cause unconsciousness and death. Symptoms of
carbon monoxide poisoning include:
- Dizziness
- Muscular Twitching
- Weakness and Sleepiness
- Throbbing in Temples
- Headache
- Inability to Think Clearly
- Nausea
- Vomiting
IF YOU OR ANYONE ELSE EXPERIENCES ANY OF THESE SYMPTOMS, GET OUT INTO THE
FRESH AIR IMMEDIATELY. If symptoms persist, seek medical attention. Shut down
the genset and do not operate it until it has been inspected and repaired.
Never sleep in the vehicle with the genset running unless the vehicle is
equipped with a working carbon monoxide detector. Primary protection against
inhaling carbon monoxide, however, is proper installation of the exhaust
system, daily (every eight hour) inspection for visible and audible exhaust
system leaks.
CONDUCTING PRE-START CHECKS
Before the first start of the day and after every eight hours of operation,
inspect the genset as instructed under CONDUCTING GENERAL INSPECTIONS (Page
16). Keep a log of maintenance and the hours run and perform any maintenance
that may be due.
See Returning the Genset to Service (Page 14) if the vehicle has been in
storage.
Before each start:
- Make sure all vehicle CO detectors are working.
- Check for signs of fuel and exhaust leaks and for damage to the exhaust system.
- Turn off the air conditioner and other large appliances.
PRIMING GASOLINE FUEL SYSTEMS
If a gasoline genset ran out of fuel prime the fuel system by holding the
control switch at STOP/PRIME for 30 seconds. (The status indicator light will
stay on solid while the pump is on.)
STARTING THE GENSET
Start the genset from the genset control panel or remote control panel inside the vehicle (Page 7).
-
Push and hold the switch at START until the genset starts. The status indicator light on the switch flashes while cranking. It will come on solid when the starter disconnects, indicating that the genset is running.
-
The genset control will discontinue cranking if the genset does not start within 30 seconds and will cause the status indicator light to blink Fault Code No. 4. Wait 5 seconds for the control to reset before trying again. See Troubleshooting (Page 22) if the genset does not start after two or three tries.
CAUTION Do not risk burning out the starter motor by continued attempts to start. Find out why the genset is not starting and repair as necessary. -
For top performance and engine life, especially in colder weather, let the engine warm up for two minutes before connecting appliances.
-
Check for fuel and exhaust leaks. Stop the genset immediately if there is a fuel or exhaust leak and have it repaired.
-
See Troubleshooting (Page 22) if the engine shuts down and the status indicator light blinks.
-
Always secure the access cover after starting the genset at the genset control panel.
WARNING Operating the genset with the access cover off can lead to severe burns and overheating of components. Always secure the cover after starting the genset.
STOPPING THE GENSET
Turn off the air conditioner and other large appliances and let the genset run
for two minutes to cool down before stopping. This reduces backfiring and run-
on. Then press the switch to STOP to stop the genset.
RESTARTING THE GENSET
See Troubleshooting (Page 22) if the genset shuts down abnormally.
LOADING THE GENSET
The genset can power AC motors, air conditioners, AC/DC converters and other
appliances. How much appliance load* can be powered depends upon the genset
power rating. The genset will shut down or its circuit breakers will trip if
the sum of the loads exceeds genset power.
To avoid overloading the genset and causing shut- downs, compare the sum of
the loads of the appliances that are likely to be used at the same time with
the power rating of the genset. Use Table 2 or the ratings on the appliances
themselves (if so marked) to obtain the individual appliance loads. It may be
necessary to run fewer appliances at the same time—the sum of the loads must
not be greater than genset rating.
Note that the genset may shut down due to over- load—even though the sum of
the loads is less than genset rating—when a large motor or air conditioner is
started last or cycles off and then on again. The reason for this is that a
motor’s startup load is much larger than its running load. It may be necessary
to run fewer appliances when large motors and air conditioners are cycling on
and off.
TABLE 2. TYPICAL APPLIANCE LOADS
Appliance | Load (watts) |
---|---|
Air Conditioner | 1400-2000 |
Battery Charger | Up to 3000 |
DC Converter | 300-700 |
Refrigerator | 600-1000 |
Microwave Oven | 1000-1500 |
Electric Frying Pan or Wok | 1000-1500 |
Electric Stove Element | 350-1000 |
Electric Water Heater | 1000-1500 |
Electric Iron | 500-1200 |
Electric Hair Dryer | 800-1500 |
Coffee Percolator | 550-750 |
Television | 200-600 |
Radio | 50-200 |
Electric Drill | 250-750 |
Electric Broom | 200-500 |
Electric Blanket | 50-200 |
Note also that air density decreases as altitude increases, causing rated genset engine power to decrease—approximately 3.5 percent each increase of 1000 feet (305 m) above the maximum elevation at which the engine can maintain rated power (Table 3). It may be necessary to run fewer appliances at higher altitudes.
De-rating for temperature usually is not necessary because the engine can maintain rated power in ambient air temperatures of up to 120° F (49° C).
TABLE 3. POWER VS. ALTITUDE
Genset Rated
7.0 kW 1| Genset Rated
6.5 kW 1| Genset Rated
5.5 kW 1
---|---|---
7000 watts up to 3000 ft (914 m)| 6500 watts up to 3000 ft (914 m)| 5500 watts
up to 5000 ft (1524 m)
6755 watts @
4000 ft (1219 m)| 6272 watts @
4000 ft (1219 m)| 5307 watts @
6000 ft (1829 m)
6510 watts @
5000 ft (1524 m)| 6044 watts @
5000 ft (1524 m)| 5114 watts @
7000 ft (2134 m)
Subtract 245 watts each additional 1000 ft
(305 m)| Subtract 228 watts each additional 1000 ft
(305 m)| Subtract 193 watts each additional 1000 ft
(305 m)
1. – This table does not take into account the effect circuit breakers may
have in limiting maximum genset power. Also, power decreases even though the
altitude adjust knob is set correctly (Page 11).
- Appliance load and genset power are measured in terms of watts (W) or kilowatts (kW), where 1 kilowatt (kW) = 1000 watts (W).
RESETTING CIRCUIT BREAKERS
If a circuit breaker in the main power distribution panel of the vehicle or on
the genset (Figure 7) trips, either a circuit shorted or too many appliances
were running. Note that the genset may continue to run after a circuit breaker
trips.
If a circuit breaker trips, disconnect or turn off as many loads as possible
and reset the circuit breaker. (Push the circuit breaker to OFF to reset it
and then to ON to reconnect the circuit.) If the circuit breaker trips right
away, either the electrical distribution system has a short circuit or the
circuit breaker is faulty. Call a qualified electrician.
If the circuit breaker does not trip, reconnect the appliances, one by one, up
to a total load that does not overload the genset or cause the circuit breaker
to trip. If a circuit breaker trips right away when an appliance is connected,
the appliance probably has a short.
Electrical appliances and tools must be used and maintained properly and be
properly grounded to cause the line circuit breakers to trip when short
circuits occur.
WARNING Short circuits in electrical appliances and tools can cause fire and electrical shock leading to severe personal injury or death. Read and follow the equipment and tool manufacturer’s instructions and warnings regarding use, maintenance and proper grounding.
CONNECTING UTILITY POWER
A vehicle with provisions for connecting utility power must have an approved
device to keep the genset and utility from being interconnected. See the
genset Installation Manual for more information.
WARNING Interconnecting the genset and the public utility (or any other power source) can lead to electrocution of utility line workers, equipment damage and fire. Use an approved switching device to prevent interconnections.
FIGURE 7. LINE CIRCUIT BREAKER
OPERATING IN COLD WEATHER
Pay particular attention to the following items when operating the genset in
cold weather:
- Make sure engine oil viscosity is appropriate for the ambient temperatures. Change oil if there is a sudden drop in temperature. See ENGINE OIL RECOMMENDATIONS (Page 6).
- Perform spark plug maintenance (Page 20).
- Perform battery maintenance (Page 19).
- If so equipped, reset the carburetor for altitude (Figure 8).
OPERATING IN HOT WEATHER
Pay particular attention to the following items when operating the genset in
hot weather:
- Make sure nothing blocks airflow to and from the genset.
- Make sure engine oil viscosity is appropriate for the ambient temperatures. See ENGINE OIL RECOMMENDATIONS (Page 6).
- Keep the genset clean.
- Perform maintenance due. See PERIODIC MAINTENANCE SCHEDULE (Page 15).
- If so equipped, reset the carburetor for altitude (Figure 8).
OPERATING AT HIGH ALTITUDE
Series HGJAB / HGJAC Only – For best fuel economy and genset operation reset
the carburetor for the current altitude (Figure 8). Altitude may be found on
road maps and road signs. For the effect of altitude on maximum power, see
LOADING THE GENSET (Page 9).
CAUTION Operating the genset at low altitude with a high altitude setting can cause power loss, overheating and engine damage. Always reset when returning to lower altitudes.
FIGURE 8. ALTITUDE ADJUST KNOB
(SERIES HGJAB / HGJAC GASOLINE ONLY)
OPERATING IN DUSTY ENVIRONMENTS
Pay particular attention to the following items when operating the genset in dusty environments:
- Do not let dirt and debris accumulate inside the genset compartment. Keep the genset clean.
- Perform air cleaner maintenance more often (Page 19).
- Change engine oil every 50 hours.
- Keep containers of engine oil that have been opened tightly closed to keep out dust.
BREAKING IN A NEW ENGINE
Proper engine break-in on a new genset or on one with a rebuilt engine is
essential for top engine performance and acceptable oil consumption. Run the
genset at approximately 1/2 rated power for the first 1 hour and then at 3/4
rated power for 1 more hour.
See LOADING THE GENSET (Page 9).
Proper engine oil and oil level are especially critical during break-in
because of the higher engine tem- peratures that can be expected. Change the
oil if not appropriate for the ambient temperatures during break-in. See
ENGINE OIL RECOMMENDATIONS (Page 6). Check oil level twice a day or every 4
hours during the first 20 hours of operation and change the oil after the
first 20 hours of operation.
EXERCISING THE GENSET
Exercise the genset at least 1 hour each month if use is infrequent. Run the
genset at approximately 1/2 rated power. See LOADING THE GENSET (Page 9). A
single exercise period is better than several shorter periods.
Exercising a genset drives off moisture, re-lubri- cates the engine, replaces
stale fuel in fuel lines and carburetor and removes oxides from electrical
con- tacts and generator slip rings. The result is better starting, more
reliable operation and longer engine life.
STORING THE GENSET
Proper storage is essential for preserving top gen- set performance and reliability when the genset cannot be exercised regularly and will be idle for more than 120 days.
Storing Genset
-
Gasoline Models Only – Fill the fuel tank with fresh fuel and add a fuel preservative (Ona- FreshTM), following the instructions on the con- tainer label. Unless a preservative (stabilizer) is added, the gasoline in the fuel system will dete- riorate causing fuel system corrosion, gum formation and varnish-like deposits which can lead to hard starting and rough operation. Then run the genset for about 10 minutes at approximately 1/2 rated power to fill the fuel lines with the fresh fuel and preservative.
**WARNING** Gasoline preservatives (stabi- lizers) are toxic. Follow the instructions on the container. Avoid skin contact. Wash hands with soap and water after using. -
Change the engine oil (Page 18) and attach a tag indicating grade of oil viscosity (Page 6).
-
Remove the air filter (Page 19) and restart the genset. While the genset is running, spray an engine fogger (OnaGardTM) into the carburetor, following the instructions on the container label, and stop the genset. The fogger leaves a protective coat of oil on the internal surfaces of the engine.
-
Gasoline Models with Carburetor – Drain the carburetor float bowl (Figure 9) into a container and dispose of the fuel in accordance with local environmental regulations. Draining the float bowl prevents deposits of gum from clogging the tiny passages in the carburetor as the gaso- line in the bowl evaporates during storage.
-
High Pressure LPG Models – Open the LPG oil drain valve (Figure 10) to drain the oil-like substance visible in the clear plastic drain hose. Oil-like sludge can migrate from the LPG sup- ply system during operation, and if allowed to accumulate, can cause hard starting and rough running. The sludge drains out through the engine oil drain hose (Page 18). Make sure to re- close the valve to keep out dust and to keep the engine running smoothly.
-
Disconnect the battery cables (negative [–] cable first) from the starting battery and store the battery according to the battery manufac- turer’s recommendations. See MAINTAINING THE BATTERY AND BATTERY CONNEC- TIONS (Page 19).
-
Plug the exhaust tail pipe to keep out dirt, mois- ture, bugs, etc.
-
Shut off the fuel supply valve (if so equipped).
-
LPG Models – Check the local ordinances if the vehicle is to be garaged. Generally, ordi- nances require that the LPG system be leak- free, that the LPG container not be filled beyond specified limits, that the container shutoff valve be closed and that the vehicle not be parked near sources of heat or ignition.
WARNING LPG leaks can lead to explosive accumulations in pits, sumps or other below-grade locations. Comply with all lo- cal ordinances regarding the garaging of vehicles with LPG engine fuel systems. -
Push the genset line circuit breaker OFF (Page 10).
|
---|---
FIGURE 9. DRAINING CARBURETOR FLOAT BOWL| FIGURE 10. DRAINING HIGH
PRESSURE LPG OF OIL
Returning Genset to Service
- Check the oil tag on the genset and change the oil if the viscosity indicated is not appropriate for the temperatures expected. See ENGINE OIL RECOMMENDATIONS (Page 6).
- Reconnect the starting battery (negative [–] cable last). See MAINTAINING THE BATTERY AND BATTERY CONNECTIONS (Page 19).
- Remove the plug from the exhaust tailpipe.
- Change the air filter element if it is dirty (Page 19).
- Open the fuel supply valve (if so equipped).
- Inspect the genset. See CONDUCTING GENERAL INSPECTIONS (Page 16).
- Gasoline Models – Prime the genset fuel system by holding the control switch at STOP/ PRIME for 30 seconds. (The status indicator light will stay on solid while the pump is on.)
High Pressure LPG Models – Make sure the LPG oil drain valve (Figure 10, Page
- is closed.
- Start the genset. There may be smoke and rough operation for a few minutes until the oil from the fogger burns off. If the engine does not start, clean or replace the spark plugs, which may have been fouled by the fogger.
- Push the genset line circuit breaker ON (Page 10) when the genset is ready to power appliances.
Periodic Maintenance
Periodic maintenance is essential for top perfor- mance and long genset life.
Use Table 4 as a guide for normal periodic maintenance. In hot and dusty
environments some maintenance procedures should be performed more frequently,
as indicated by the footnotes in the table. Keeping a log of main- tenance
performed and hours run will help you keep genset maintenance regular and
provide a basis for supporting warranty claims (Page 33).
Maintenance, replacement or repair of emission control devices and systems may
be performed by any engine repair establishment or individual. However,
warranty work must be completed by an authorized Onan dealer.
TABLE 4. PERIODIC MAINTENANCE SCHEDULE
MAINTENANCE PROCEDURE | MAINTENANCE FREQUENCY |
---|---|
Every Day or Every 8 Hours | After First 20 Hours |
Every 150 Hours | Every 450 Hours |
General Inspections | X |
Check Engine Oil Level | X |
Clean and Check Battery | |
Clean Spark Arrestor | |
Change Engine Oil & Oil Filter | |
Replace Air Filter Element | |
Replace Spark Plugs | |
Clean Engine Cooling Fins | |
Replace Fuel Filter | |
Adjust Valve Lash | |
Clean or Replace Cylinder Heads |
1 – As a part of engine break-in, change the engine oil after the first 20
hours of operation.
2 – Perform more often when operating in dusty environments.
3 – Perform more often when operating in hot weather.
4 – Perform at least once a year.
5 – Perform sooner if engine performance deteriorates.
6 – Must be performed by a qualified mechanic (authorized Onan dealer).
CONDUCTING GENERAL INSPECTIONS
Inspect the genset before the first start of the day and after every eight
hours of operation.
Oil Level
Check engine oil level (Page 17).
Exhaust System
Look and listen for exhaust system leaks while the genset is running. Shut
down the genset if a leak is found and have it repaired before operating the
genset again.
Look for openings or holes between the genset compartment and vehicle cab or
living space if the genset engine sounds louder than usual. Have all such
openings or holes closed off or sealed to prevent exhaust gases from entering
the vehicle.
Replace dented, bent or severely rusted sections of the tailpipe and make sure
the tailpipe extends at least 1 inch (25.4 mm) beyond the perimeter of the
vehicle.
Park the vehicle so that genset exhaust gases disperse away from the vehicle.
Barriers such as walls, snow banks, high grass and brush and other vehicles
can cause exhaust gases to accumulate in and around the vehicle.
Do not operate power ventilators or exhaust fans while the vehicle is standing
with the genset running. The ventilator or fan can draw exhaust gases into the
vehicle.
Check all CO monitors to assure proper operation.
WARNING EXHAUST GAS IS DEADLY! Do not operate the genset if there is an
exhaust leak or any danger of exhaust gases entering or being drawn into the
vehicle.
WARNING Do not park the vehicle in high grass or brush. Contact with the
exhaust system can cause a fire.
Fuel System
Check for leaks at the hose, tube and pipe fittings in the fuel supply and
return systems while the genset is running and while it is stopped. Do not use
a flame to check for LPG leaks. Check flexible fuel hose sections for cuts,
cracks, and abrasions. Make sure the fuel line is not rubbing against other
parts. Replace worn or damaged fuel line parts before leaks occur.
If you smell gas, close the LPG container shutoff valve and have the genset
serviced before using it again.
WARNING Gasoline and LPG are highly flammable and explosive and can cause severe personal injury or death. Shut down the genset and repair leaks immediately.
Battery Connections
Check the battery terminals for clean, tight connections. Loose or corroded
connections have high electrical resistance which makes starting harder. See
MAINTAINING THE BATTERY AND BATTERY CONNECTIONS (Page 19).
WARNING Arcing at battery terminals or light switch or other equipment or flames and sparks can ignite battery gas causing severe personal injury—Ventilate battery area before working on or near battery—Wear safety glasses—Do not smoke—Switch trouble light ON / OFF away from battery—Do not disconnect battery cables while genset is running or vehicle battery charging system is on—Always disconnect negative (–) cable first and reconnect it last.
Mechanical
Look for mechanical damage. Start the genset and look, listen and feel for any
unusual noises and vibrations.
Check the genset mounting bolts to make sure they are secure.
Check to see that the genset air inlet and outlet openings are not clogged
with debris or blocked.
Clean accumulated dust and dirt from the genset.
Do not clean the genset while it is running or still hot.
Protect the generator, air cleaner, control panel, and electrical connections
from water, soap and cleaning solvents.
WARNING Always wear safety glasses when using compressed air, a pressure washer or a steam cleaner to avoid severe eye injury.
CHECKING ENGINE OIL LEVEL
Park the vehicle on level ground and shut off the genset before checking the
engine oil level.
WARNING Crankcase pressure can blow hot engine oil out the fill opening causing severe burns. Always stop the genset before removing the oil fill cap.
-
Unscrew the oil fill cap and wipe oil off the dipstick (Figure 11). Screw the cap back on, remove it and check the oil level on the dip stick.
-
Add or drain oil as necessary. See ENGINE OIL RECOMMENDATIONS (Page 6). Keep the oil level between the FULL and ADD marks.
CAUTION Too much oil can cause high oil consumption. Too little oil can cause severe engine damage. Keep the oil level between the FULL and ADD marks. OIL FILLS VERY SLOWLY. TAKE YOUR TIME AND CHECK LEVEL OFTEN WHILE FILLING. IT TAKES TIME FOR THE AIR IN THE CRANKCASE TO ESCAPE AND ALLOW OIL TO ENTER. -
Screw the oil fill cap back on securely.
FIGURE 11. OIL FILL/DIPSTICK AND DRAIN VALVE
CHANGING ENGINE OIL AND OIL FILTER
WARNING State and federal agencies have determined that contact with used
engine oil can cause cancer or reproductive toxicity. Try to avoid skin
contact and breathing of vapors. Use rubber gloves and wash exposed skin.
Refer to Table 4 for scheduled engine oil change.
Change oil more often in hot or dusty environments.
-
Place a pan underneath the oil drain hose and filter (Figure 12). Run and then stop the engine when it is warm.
WARNING Crankcase pressure can blow hot engine oil out the fill opening causing severe burns. Always stop the genset be- fore removing the oil fill cap. -
Remove the oil fill cap, open the oil drain valve (Figure 11), let all oil drain from the engine and then close the drain valve.
-
High Pressure LPG Gensets: Drain the LPG system of accumulated oil (Item 5, Page 13).
-
Spin off the old oil filter and thoroughly wipe off the filter mounting surface. Remove the old gasket if it does not come off with the filter.
-
Apply a film of oil to the filter gasket and spin the new filter on by hand until the gasket just touches the mounting pad. Then turn it 1/2 to 3/4 turn—not more.
-
Refill with 2 quarts (1.8 l) of oil. See ENGINE OIL RECOMMENDATIONS (Page 6). Check and add or drain oil as necessary.
CAUTION Too much oil can cause high oil consumption. Too little oil can cause severe engine damage. Keep the oil level between the FULL and ADD marks.
OIL FILLS VERY SLOWLY. TAKE YOUR TIME AND CHECK LEVEL OFTEN WHILE FILLING. IT TAKES TIME FOR THE AIR IN THE CRANKCASE TO ESCAPE AND ALLOW OIL TO ENTER. -
Dispose of the used oil and oil filter in accordance with local environmental regulations.
FIGURE 12. OIL FILTER AND DRAIN HOSE—VIEW FROM BELOW OF FRONT EDGE OF GENSET
MAINTAINING BATTERY AND BATTERY CONNECTIONS
WARNING Arcing at battery terminals or light switch or other equipment or flames and sparks can ignite battery gas causing severe personal injury—Ventilate battery area before working on or near battery—Wear safety glasses—Do not smoke—Switch trouble light ON / OFF away from battery—Do not disconnect battery cables while genset is running or vehicle battery charging system is on—Always disconnect negative (–) cable first and reconnect it last.
Refer to Table 4 for scheduled battery maintenance, and follow the battery
manufacturer’s instructions.
Have the battery charging system serviced if DC system voltage is consistently
low or high.
Always:
- Keep the battery case and terminals clean and dry and the terminals tight.
- Remove battery cables with a battery terminal puller.
- Make sure which terminal is positive (+) and which is negative (–) before making battery connections, always removing the negative (–) cable first and reconnecting it last to reduce arcing.
REPLACING THE AIR FILTER ELEMENT
Refer to Table 4 for scheduled air filter element replacement. In dusty
environments the filter element should be inspected and changed more
frequently. To change the filter element (Figure 13):
- Unlatch the three spring clips and rotate the cover out and away from the hooks on top. Remove the air filter element.
- Wipe the filter element sealing surfaces clean and reassemble the air filter with a new filter element.
REPLACING SPARK PLUGS
Refer to Table 4 for scheduled spark plug replacement. (The genset has two
spark plugs, Figure 14.) The spark plugs must be in good condition for proper
engine starting and performance. A spark plug that fouls frequently or has
heavy soot deposits indicates the need for engine service. See Troubleshooting
(Page 22).
To prevent cross threading, always thread a spark plug in by hand until it
seats and then torque to 10 lbs-ft (13 N-m).
CLEANING THE SPARK ARRESTOR
Refer to Table 4 for scheduled cleaning of the spark arrestor muffler.
Cleaning is required for maximum genset performance. Park the vehicle away
from grass, brush or debris that could be ignited by sparks expelled during
this procedure.
WARNING A hot muffler can cause severe burns. Let the muffler cool down before removing or installing cleanout plugs or screens.
Series HGJAA: A double-drum muffler is mounted inside the genset. The cleanout plug is in the top drum, but accessible from below, though not readily visible. In Figure 15 a portion of the lower drum is cut out so that the location of the plug is visible.
- Locate the square-headed cleanout plug by hand and solidly seat a 7/16 inch, eight point, 3/8 inch drive socket wrench with 3 inch extension on the plug. Then add a swivel section and 6 inch extension and turn with a ratchet to remove the plug.
- Start and load the genset to near full power (Page 9). Let the genset run for about five minutes to expel the soot in the muffler.
- Stop the genset, allow the muffler to cool down and then reinstall the plug.
Series HGJAB: See Figure 15 if double-drum or Figure 16 if single-drum. On a single-drum muffler the cleanout plug is accessible from below as shown in Figure 16.
- Remove the plug with a 7/16 inch, eight point socket wrench.
- Start and load the genset to near full power (Page 9). Let the genset run for about five minutes to expel the soot in the muffler.
- Stop the genset, allow the muffler to cool down and then reinstall the plug.
Series HGJAC: The muffler is externally mounted.
If it has a clean out plug like the one shown in Figure 16, use the
instructions for Series HGJAB as a guide. Alternatively, the end of the tail
pipe may have a spark screen (Figure 17). If so, remove the screw that secures
the spark screen, clean the screen with a wire brush and re-install it.
FIGURE 15. HJGAA CLEANOUT PLUG—VIEW FROM BELOW
FIGURE 16. HJGAB CLEANOUT PLUG—VIEW FROM BELOW
FIGURE 17. TYPICAL SPARK SCREEN
Troubleshooting
WARNING Hot engine parts can cause severe burns. Always allow the engine time to cool before performing any maintenance or service.
TABLE 5. TROUBLESHOOTING lists the Fault Codes in numerical order along with step-by-step corrective actions. If you are unable to resolve the problem after taking the corrective actions suggested, contact an authorized Onan dealer. See How to Obtain Service (Page 32).
First note the following:
- Maintaining engine oil level, keeping battery connections clean and tight, watching the fuel gauge, not overloading the genset, etc. will prevent most shutdowns.
- When the genset and vehicle engine share a common fuel tank the fuel dip tubes are usually arranged so that the genset will run out of fuel first. Marking the genset empty point on the fuel gauge will make it easier to tell when to stop the genset before running it out of fuel.
FAULT CODES
The genset controller provides extensive diagnostics by causing the status
indicator light on the Control Switch to blink in a coded fashion. Following a
fault shutdown, the indicator light will repeatedly blink 2, 3 or 4 blinks at
a time.
-
Two blinks indicates a low oil pressure fault.
-
Three blinks indicates a service fault. Press Stop once to cause the two-digit, secondlevel fault code to blink. (Pressing Stop again will stop the blinking.)The two-digit code consists of 1, 2, 3, 4 or 5 blinks, a brief pause, and then 1 to 9 blinks. The first set of blinks represents the tens digit and the second set of blinks the units digit of the fault code number.
For example, Fault Code No. 36 appears as: blink-blink-blink—pause—blink- blink-blink-blink-blink-blink—long pause—repeat -
Four blinks indicates that cranking exceeded 30 seconds without the engine starting.
-
Note: Fault Code Nos. 3 and 4 are first level faults. Avoid interpreting them as second-level Fault Code Nos. 33 and 44, which have not been assigned as fault codes.
Restoring Fault Code Blinking – The fault code stops blinking after five minutes (15 minutes, Series HGJAA). Press Stop three times within five seconds to restore blinking. Note that the last fault logged will blink, even after the condition that caused the shutdown has been corrected.
TABLE 5. TROUBLESHOOTING
WARNING
Some genset service procedures present hazards that can result in severe
personal injury or death. Only trained and experienced service personnel with
knowledge of fuels, electricity, and machinery hazards should perform genset
service. See Safety Precautions.
STATUS INDICATOR LIGHT DEAD
(Faulty connections, no battery voltage)
Corrective Action:
- Try the genset Start Switch if the remote Start Switch does not work, and vice versa.
- Clean and tighten the positive (+) and negative (–) battery cable connections at the battery, vehicle frame and genset.
- Recharge or replace the battery. Refer to the battery manufacturer’s recommendations.
STARTING BATTERIES RUN DOWN
(Marginal batteries, connections, or charging system or, parasitic loads)
Corrective Action:
- Clean and tighten the positive (+) and negative (–) battery cable connections at the battery, vehicle frame and genset.
- Recharge or replace the battery. Refer to the battery manufacturer’s recommendations.
- Have a battery charging system installed or serviced in the vehicle.
STARTER ENGAGES-DISENGAGES
(Cranking voltage dips below 6 volts—low battery charge, poor connections,
long cables)
Corrective Action:
- Have the vehicle propulsion engine running while trying to start the genset—the battery charging alternator may be able to maintain starting voltage high enough to get the genset started.
- Clean and tighten the positive (+) and negative (–) battery cable connections at the battery, vehicle frame and genset.
- Recharge or replace the battery. Refer to the battery manufacturer’s recommendations.
- Increase battery cable size or run parallel cables.
NO POWER—GENSET RUNNING, STATUS LIGHT ON
(Line circuit breaker OFF, or tripped due to short circuit or overload)
Corrective Action:
- Turn on or reset the line circuit breaker on the genset (Page 10).
- Turn on or reset the line circuit breakers on the main distribution panel in the vehicle.
LOW OIL PRESSURE FAULT—CODE NO. 2
(First-level fault code—Low oil pressure cutoff switch did not open)
Corrective Action:
- Check engine oil level and add oil as necessary (Page 17).
- Drain excess oil (above dipstick Full mark.)
SERVICE CHECK FAULT—CODE NO. 3
(First-level fault code—Indicates fault with second-level fault code)
Corrective Action: Check the second-level fault code by pressing STOP once. The second-level fault code will have two-digits. The faults are listed in numerical order in this table.
OVERCRANK FAULT—CODE NO. 4
(First-level fault code—Cranking exceeded 30 seconds without engine starting)
Corrective Action:
- Gasoline Models – Check and fill the fuel tank, as necessary. (Note: The genset fuel pickup tube is probably higher up in the fuel tank than the vehicle engine pickup.)
- Prime the engine fuel system by holding the control switch at Stop/Prime for 30 seconds.
- Low Pressure LPG Models – Check and fill the LPG container, as necessary. On cold days the LPG container may have to be kept at least half full to provide the rate of vaporization necessary to keep up with the genset fuel demand.
- High Pressure LPG Models – Check and fill the LPG container, as necessary, and drain the genset LPG system of oil that may have migrated from the supply system (Item 5, Page 13). Make sure to re-close the drain valve.
- Open any closed fuel valves.
- Secure the spark plug leads on the spark plugs (Page 20).
- Replace the spark plugs (Page 20).
- Service the air cleaner (Page 19).
OVERVOLTAGE FAULT—CODE NO. 12
(Controller unable to maintain rated voltage)
Corrective Action: See an authorized Onan dealer.
UNDERVOLTAGE FAULT—CODE NO. 13
(Controller unable to maintain rated voltage)
Corrective Action: Reduce the number of connected appliances, especially
when air conditioners and battery chargers are running.
OVERFREQUENCY FAULT—CODE NO. 14
(Engine governor unable to maintain rated frequency)
Corrective Action: See an authorized Onan dealer.
UNDERFREQUENCY FAULT—CODE NO. 15
(Engine governor unable to maintain rated frequency)
Corrective Action:
- Reduce the number of connected appliances, especially when air conditioners and battery chargers are running.
- High Pressure LPG Models – Drain the genset LPG system of oil that may have migrated from the supply system (Item 5, Page 13). Make sure to re-close the drain valve.
GOVERNOR ACTUATOR FAULT—CODE NO. 19
(Controller sensed open or shorted circuit)
Corrective Action: See an authorized Onan dealer.
GOVERNOR ACTUATOR OVERLOAD FAULT—CODE NO. 22
(Duration of operation at or near full-duty cycle beyond design limit)
Corrective Action:
- Reduce the number of connected appliances, especially when air conditioners and battery chargers are running.
- Service the air cleaner (Page 19).
- Check for and repair a blocked exhaust system.
LOW OIL PRESSURE CUTOFF SWITCH FAULT—CODE NO. 23
(Controller sensed switch still open during start—not a running fault)
Corrective Action: See an authorized Onan dealer.
VOLTAGE SENSE FAULT—CODE NO. 27
(Controller unable to sense output voltage)
Corrective Action: See an authorized Onan dealer.
HIGH BATTERY VOLTAGE FAULT—CODE NO. 29
(Voltage across battery system greater than 19 volts)
Corrective Action:
- Check battery bank connections and reconnect if necessary so that the 12 volt batteries serving the genset are connected in parallel (12 volt) rather than in series (24 volt).
- Select a lower battery boost charge rate.
OVERSPEED FAULT—CODE NO. 31
(Engine speed greater than 3400 rpm)
Corrective Action : See an authorized Onan dealer.
LOW CRANKING SPEED FAULT—CODE NO. 32
(Cranking speed less than 180 rpm for more than 2 seconds)
Corrective Action:
- Clean and tighten the positive (+) and negative (–) battery cable connections at the battery and at the genset.
- Recharge or replace the battery. Refer to the battery manufacturer’s recommendations.
- Replace engine oil with oil of proper viscosity for ambient temperatures (Page 6). (High oil viscosity can slow down cranking speed.)
CONTROL CARD FAILURE FAULT—CODE NO. 35
(Microprocessor EEPROM error during self-test)
Corrective Action: See an authorized Onan dealer.
ENGINE STOPPED FAULT—CODE NO. 36
(Engine stopped without command by controller)
Corrective Action:
- Gasoline Models – Check and fill the fuel tank, as necessary. (Note: The genset fuel pickup tube is probably higher up in the fuel tank than the vehicle engine pickup.)
- Low Pressure LPG Models – Check and fill the LPG container, as necessary. On cold days the LPG container may have to be kept at least half full to provide the rate of vaporization necessary to keep up with the genset fuel demand.
- High Pressure LPG Models – Check and fill the LPG container, as necessary, and drain the genset LPG system of oil that may have migrated from the supply system (Item 5, Page 13). Make sure to re-close the drain valve.
- Secure the spark plug leads on the spark plugs (Page 20).
- Replace the spark plugs (Page 20).
- Service the air cleaner (Page 19).
- Check for mechanical damage.
INVALID GENSET CONFIGURATION FAULT—CODE NO. 37
(Wrong frequency/rpm ratio)
Corrective Action: See an authorized Onan dealer.
OVERCURRENT (FIELD OVERLOAD) FAULT—CODE NO. 38
(Low power factor loads)
Corrective Action:
- Reduce the number of appliances running at the same time, especially those with high motor starting loads such as air conditioners.
- Have air conditioners and other appliances checked for proper operation. (A locked compressor rotor can cause very low power factor.)
GENERATOR ROTOR FAULT—CODE NO. 41
(Controller unable to sense field or output voltage)
Corrective Action: See an authorized Onan dealer.
PROCESSOR FAULT—CODE NO. 4 2
(Microprocessor ROM error during self-test)
Corrective Action: See an authorized Onan dealer.
PROCESSOR FAULT—CODE NO. 43
(Microprocessor RAM error during self-test)
Corrective Action: See an authorized Onan dealer.
SPEED SENSE FAULT—CODE NO. 45
(Controller unable to sense quadrature frequency)
Corrective Action: See an authorized Onan dealer.
IGNITION FAULT—CODE NO. 47
(Controller unable to sense ignition)
Corrective Action: See an authorized Onan dealer.
GENERATOR FIELD SENSE FAULT—CODE NO. 48
(Controller unable to sense field voltage)
Corrective Action: See an authorized Onan dealer.
PROCESSOR FAULT—CODE NO. 51
(Microprocessor malfunction)
Corrective Action: See an authorized Onan dealer.
FUEL INJECTOR FAULT—CODE NO. 52
(Open or short circuit in fuel injector)
Corrective Action: See an authorized Onan dealer.
MAT SENDER FAULT—CODE NO. 54
(Open or short circuit in MAT sender)
Corrective Action: See an authorized Onan dealer.
MAP SENDER FAULT—CODE NO. 56
(Open or short circuit in MAP sender)
Corrective Action: See an authorized Onan dealer.
OVERPRIME FAULT—CODE NO. 57
(Prime mode exceeded 3 minutes)
Corrective Action: Check for and remove any object that may be holding either
control switch (remote or local) in the prime position.
Specifications
| GASOLINE MODELS
---|---
7.0 HGJAA| 7.0 HGJAB| 7.0 HGJAC| 5.5 HGJAA| 5.5
HGJAB| 5.5 HGJAC
GENERATOR: 2-Pole Revolving Field, 2-Bearing, Self-Excited, 1-Phase,
Vertical Shaft, Capped Digital Voltage Regulation
Power| 7000 watts| 5500 watts
Frequency| 60 Hertz| 60 Hertz
Voltage| 120 volts| 120 volts
Current| 58.3 amp| 45.8 amp
Speed| 3600 rpm| 3600 rpm
FUEL CONSUMPTION:
No load| 0.43 gph (1.6 l/h)| 0.43 gph (1.6 l/h)| 0.43 gph (1.6 l/h)| 0.34 gph
(1.3 l/h)| 0.35 gph (1.3 l/h)| 0.35 gph (1.3 l/h)
Half load| 0.70 gph (2.7 l/h)| 0.73 gph (2.8 l/h)| 0.73 gph (2.8 l/h)| 0.58
gph (2.2 l/h)| 0.60 gph (2.3 l/h)| 0.60 gph (2.3 l/h)
Full load| 1.13 gph (4.3 l/h)| 1.22 gph (4.6 l/h)| 1.22 gph (4.6 l/h)| 0.89
gph (3.4 l/h)| 0.95 gph (3.6 l/h)| 0.95 gph (3.6 l/h)
ENGINE: Air-Cooled, 4-Cycle Spark-Ignited, OHV, 90° V Twin Cyl, Vertical
Shaft
Fueling Method| SFI1| Carburetor| Carburetor| SFI1| Carburetor| Carburetor
Governor| Digital| Mechanical| Mechanical| Digital| Mechanical| Mechanical
Speed| 2880 rpm| 2400 rpm
Bore| 3.15 in (80 mm)| 3.15 in (80 mm)
Stroke| 2.56 in (65 mm)| 2.56 in (65 mm)
Displacement| 39.8 in3 (653 cc)| 39.8 in3 (653 cc)
Comp. Ratio| 8.0 : 1| 8.0 : 1
Oil Capacity| 2.0 quart (1.8 l)| 2.0 quart (1.8 l)
Valve Lash (Cold)| 0.004 in (0.10 mm), Intake & Exhaust| 0.004 in (0.10 mm),
Intake & Exhaust
Spark Plug| 18–25 lbs-ft (23–32 N-m)| 18–25 lbs-ft (23–32 N-m)
Ignition Timing| 20° BTDC, non-adjustable magneto| 20° BTDC, non-adjustable
magneto
Magneto Air Gap| 0.012 in (0.3 mm)| 0.012 in (0.3 mm)
Spark Plug Gap| 0.025 in (6-7 mm)| 0.025 in (6-7 mm)
DC SYSTEM:
Battery Voltage| 12 volts| 12 volts
Min. Battery CCA| 450 @ 0° F (–18° C)| 450 @ 0° F (–18° C)
INSTALLATION:
Exhaust O. D.| 1-1/4 in| 1-1/4 in
Max. Exhaust Back Pressure| –| –| 35 in (889 mm) WC| –| –| 35 in (889 mm) WC
Fuel Supply Connection| 5/16 in. SAE J1231 Type 1| 1/4 in. SAE J1231 Type 1|
1/4 in. SAE J1231 Type 1| 5/16 in. SAE J1231 Type 1| 1/4 in. SAE J1231 Type 1|
1/4 in. SAE J1231 Type 1
Fuel Return Connection| 1/4 in. SAE J1231 Type 1| –| –| 1/4 in. SAE J1231 Type
1| –| –
Noise dB(A)2| 65| 67| 75| 64| 66| 74
Weight| 290 lb (132 Kg)| 290 lb (132 Kg)| 239 lb (107 Kg)| 279 lb (127 Kg)|
279 lb (127 Kg)| 228 lb (104 Kg)
Compartment (H x D x W)3| HGJAA/HGJAB: 17.2 in x 23.2 in x 34.6 in (438 mm x
589 mm x 879 mm)
HGJAC: 16.5 in x 22.8 in x 27.9 in (420 mm x 579 mm x 709 mm)
1. Sequential Multiport Fuel Injection
2. Measurements @ 10 ft (3 m) in a typical RV installation, under an 4 kW
load.
3. With 1/2 in. clearances. See the Installation Manual for additional
considerations when sizing the genset compartment.
| LPG MODELS
---|---
6.5 HGJAA| 6.5 HGJAB| 6.5 HGJAC| 5.5 HGJAA| 5.5
HGJAB| 5.5 HGJAC
GENERATOR: 2-Pole Revolving Field, 2-Bearing, Self-Excited, 1-Phase,
Vertical Shaft, Capped Digital Voltage Regulation
Power| 6500 watts| 5500 watts
Frequency| 60 Hertz| 60 Hertz
Voltage| 120 volts| 120 volts
Current| 54.2 amp| 45.8 amp
Speed| 3600 rpm| 3600 rpm
FUEL CONSUMPTION:
No load| 2.2 lbs/h (1.0 kg/h)| 2.2 lbs/h (1.0 kg/h)| 2.2 lbs/h (1.0 kg/h)| 1.8
lbs/h (0.8 kg/h)| 1.8 lbs/h (0.8 kg/h)| 1.8 lbs/h (0.8 kg/h)
Half load| 3.9 lbs/h (1.8 kg/h)| 3.9 lbs/h (1.8 kg/h)| 3.9 lbs/h (1.8 kg/h)|
3.3 lbs/h (1.5 kg/h)| 3.3 lbs/h (1.5 kg/h)| 3.3 lbs/h (1.5 kg/h)
Full load| 5.3 lbs/h (2.4 kg/h)| 5.3 lbs/h (2.4 kg/h)| 5.3 lbs/h (2.4 kg/h)|
4.6 lbs/h (2.1 kg/h)| 4.6 lbs/h (2.1 kg/h)| 4.6 lbs/h (2.1 kg/h)
ENGINE: Air-Cooled, 4-Cycle Spark-Ignited, OHV, 90° V Twin Cyl, Vertical
Shaft
Fueling Method| Air/Fuel Mixer| Air/Fuel Mixer
Governor| Mechanical| Mechanical
Speed| 2880 rpm| 2400 rpm
Bore| 3.15 in (80 mm)| 3.15 in (80 mm)
Stroke| 2.56 in (65 mm)| 2.56 in (65 mm)
Displacement| 39.8 in3 (653 cc)| 39.8 in3 (653 cc)
Comp. Ratio| 8.0 : 1| 8.0 : 1
Oil Capacity| 2.0 quart (1.8 l)| 2.0 quart (1.8 l)
Valve Lash (Cold)| 0.004 in (0.10 mm), Intake & Exhaust| 0.004 in (0.10 mm),
Intake & Exhaust
Spark Plug| 18–25 lbs-ft (23–32 N-m)| 18–25 lbs-ft (23–32 N-m)
Ignition Timing| 20° BTDC, non-adjustable magneto| 20° BTDC, non-adjustable
magneto
Magneto Air Gap| 0.012 in (0.3 mm)| 0.012 in (0.3 mm)
Spark Plug Gap| 0.025 in (6-7 mm)| 0.025 in (6-7 mm)
DC SYSTEM:
Battery Voltage| 12 volts| 12 volts
Min. Battery CCA| 450 @ 0° F (–18° C)| 450 @ 0° F (–18° C)
INSTALLATION:
Exhaust O. D.| 1-1/4 in| 1-1/4 in
Max. Exhaust Back Pressure| –| –| 35 in (889 mm) WC| –| –| 35 in (889 mm) WC
LPG Vapor:
Connection Pressure| 3/8–18 NPTF
9-13 in (228-330 mm) WC| 3/8–18 NPTF
9-13 in (228-330 mm) WC
LPG Liquid:
Connection Pressure| 1/4–18 NPTF
Tank Pressure| 1/4–18 NPTF
Tank Pressure
Noise dB(A)1| 65| 67| 75| 64| 67| 74
Weight| 290 lb (132 Kg)| 290 lb (132 Kg)| 239 lb (107 Kg)| 279 lb (127 Kg)|
279 lb (127 Kg)| 228 lb (104 Kg)
Compartment (H x D x W)2| HGJAA/HGJAB: 17.2 in x 23.2 in x 34.6 in (438 mm x
589 mm x 879 mm)
HGJAC: 16.5 in x 22.8 in x 27.9 in (420 mm x 579 mm x 709 mm)
1. Measurements @ 10 ft (3 m) in a typical RV installation, under an 4 kW
load.
2. With 1/2 in. clearances. See the Installation Manual for additional
considerations when sizing the genset compartment.
Information for California Genset Users
This genset meets the requirements of California’s Exhaust Emissions Standards
as stated on the nameplate. Figure 1 (Page 4) illustrates where this
information appears on the nameplate.
As a California user of this genset, please be aware that unauthorized
modifications or replacement of fuel, exhaust, air intake, or speed control
system components that affect engine emissions are prohibited. Unauthorized
modification, removal or replacement of the genset label is prohibited.
You should carefully review Operator (Owner), Installation and other manuals
and information you receive with your genset. If you are unsure that the
installation, use, maintenance or service of your genset is authorized, you
should seek assistance from an approved Onan dealer.
California genset users may use Table 6 as an aid in locating information
related to the California Air Resources Board requirements for emissions
control.
TABLE 6. EMISSIONS CONTROL INFORMATION
Genset Warranty Information| The California emissions control warranty
statement is located in the same packet of information as this manual when the
genset is shipped from the factory.
---|---
Engine Valve Lash| See Specifications (Page 29).
Engine Ignition Timing| See Specifications (Page 29).
Engine Fuel Requirements| Gasoline Models: The engine is certified to
operate on unleaded gasoline. See Fuel Recommendations (Page 6).
LPG Models: The engine is certified to operate on LPG. See Fuel
Recommendations (Page 6).
Engine Lubricating Oil Requirements| See ENGINE OIL RECOMMENDATIONS (Page 6).
Engine Fuel Mixture Settings| Gasoline Models—Fuel Injection: The
precision-manufac-tured fuel injection system is not adjustable.
All Other Models: The precision-manufactured carburetor is not
adjustable.
Engine Adjustments| Gasoline Models—Fuel Injection: Not applicable
Gasoline Models—Carburetor: See Figure 8 (Page 11).
LPG Models: Not applicable.
Engine Emission Control System| Gasoline Models—Fuel Injection: The
engine emissions con- trol system consists of Sequential Multiport Fuel
Injection (SFI).
All Other Models: The engine emissions control system con- sists of
internal engine design.
How to Obtain Service
When you need service, parts, or product literature (such as the Service
Manual) for your genset, con- tact the nearest authorized distributor. Onan
has factory-trained representatives to handle your needs for genset parts and
service.
Call 1-800-888-ONAN to contact the nearest Cum- mins/Onan or Onan-only
distributor in the United States or Canada. (This automated service utilizes
touch-tone phones only). Select OPTION 1 (press 1) to be automatically
connected to the distributor nearest to you.
If you are unable to contact a distributor using the automated service,
consult the Yellow Pages. Typically, our distributors are listed under:
GENERATORS – ELECTRIC,
ENGINES – GASOLINE OR DIESEL, or
RECREATIONAL VEHICLES – EQUIPMENT,
PARTS AND SERVICE.
If you are outside North America, call Onan Corporation at 1–763–574–5000 from 7:30 AM to 4:00 PM, Central Standard Time, Monday through Friday, or fax 1–763–528–7229.
Before calling for service, have the following information available:
- The complete genset model number and serial number. See Model Identification (Page 4).
- The date of purchase.
- The nature of the problem. See Troubleshooting (Page 22).
If you have difficulty in arranging service or resolving a problem, please contact the Service Manager at the nearest Cummins/Onan distributor for assistance.
WARNING Improper service or replacement of parts can result in severe personal injury, death, and/or equipment damage. Service personnel must be trained and experienced in performing electrical and/or mechanical service.
Maintenance Record
Record all periodic and unscheduled maintenance and service. See Periodic Maintenance (Page 15).
DATE | HOUR METER READING | MAINTENANCE OR SERVICE PERFORMED |
---|---|---|
Record the name, address, and phone number of your authorized Onan service center.
Cummins Power Generation
1400 73rd Avenue N.E.
Minneapolis, MN 55432
763-574-5000
Fax: 763-528-7229
Cummins and Onan are registered trademarks of Cummins Inc.
Redistribution or publication of this document,
by any means, is strictly prohibited.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>