ecowitt WH46 NDIR CO and PM2.5 Haze Sensor User Manual
- June 16, 2024
- ECOWITT
Table of Contents
- NDIR CO₂ and PM2.5 haze sensor
- Manual
- Model WH46
- 1. Ecowitt Ecosystem
- 2.Similar sensor
- 3. Before Configuration
- 4. Getting Started
- 5. View Online Data
- 6. History data on ecowitt.net
- 7. Sensor Placement & Mounting
- 8. Features
- 9. Specification
- 10.Carbon Dioxide Levels and potential health problems are indicated
- 11. What types of NDIR sensors exist and how do they work?
- 12. CARE +MAINTENANCE
- 13. Warranty Information
- 14. Sensor Calibration
- 15. After-sales Service
- 16.Stay in Touch
- Manual
- Documents / Resources
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
NDIR CO₂ and PM2.5 haze sensor
CO₂/PM1.0/PM2.5/PM4.0/PM10/Temperature/Humidity 7-in-1
Manual
Model WH46
1. Ecowitt Ecosystem
- ecowitt app
- ecowitt CLOUD system
- ROUTER
- CO₂ SENSOR
- WiFi HUB
- Sub-GHz (RF)
- Internet
- LAN/2.4Hz Wi-Fi
Welcome to our product! To send data to the ecowitt cloud server and enable users to access it via our mobile app, our product requires the setup of a gateway and a router.
2.Similar sensor
Model
| WH41| WH43| WH45| WH46
---|---|---|---|---
Finish
| |
CO₂
| | | ✔| ✔
PM1.0| | | |
✔
PM2.5
| ✔| ✔| ✔| ✔
PM4.0| | | |
✔
PM10
| | | ✔| ✔
Temperature & Humidity| | | ✔|
✔
Solar power supply
| ✔| | |
Power cord supply| ✔| ✔| ✔|
✔
Battery backup
| ✔| ✔| ✔| ✔
Sensor ID Name| 4 CH PM2.5|
AQIN
Note: If you have a WH41/WH43/WH45/WH46 PM2.5 sensor, the reading of PM2.5 may be different due to different sensor type used.
3. Before Configuration
Prepare an console that has been added to Ecowitt APP, ensuring the frequency matches. The compatible models are listed in the table below.
GW1XXX
|
GW2000
|
WS3800
|
WS39XX
---|---|---|---
WN182X
|
WN19XX
|
WN1980
|
WN1920
HP25XX
|
HP3500
| |
4. Getting Started
4.1 Parts List
One NDIR CO₂ and PM2.5 haze sensor
One USB Cable
One User Manual
4.2 Sensor Set Up
1.Remove the battery door on the base of the air quality sensor as shown in Figure 1.
Figure 1
No
| Description
---|---
1
| LED Indicator
(RF transmission)
2
| AC Adapter USB Power Port
3
| Battery Compartment Cover
4
| Battery Compartment
2. Insert two AA batteries and close the battery door.
Note: The batteries (not included) are mainly for backup purpose.
2. Connect the USB cable between the sensor and an AC adapter(not included).
Note: After inserting the batteries or connecting AC power, the sensor LED indicator will light for 3 seconds flash once after 20s, and then flash once per 1 minute thereafter (10 minutes if only powered by batteries). Each time it flashes, the sensor is transmitting data.
4.3 Adding and setting sensor on APP
Open the ecowitt APP → “•••” → “Sensor ID”→ “ ”
→Enter sensor ID from WH46 to save
5. View Online Data
When paired with HP2550/HP2560 Console:
Figure 1 Dashboard
- The CO₂, PM1.0, PM2.5, PM4.0, PM10 data automatically scrolls displaying on the screen every 5 seconds.
Figure 2 Page Sensor Name &Data
- The T&H, CO₂, PM1.0, PM2.5, PM4.0, PM10 data on Figure 2 Page Sensor Name&Data
When paired with WS3800/WS3900 Console:
- Press button “+” to switch DATE, CO₂, PM1.0, PM2.5, PM10 and AQI data when default mode.
- Note: PM4.0,T&H reading on ecowitt APP or web page, but not display on console
When paired with WN1820:
Press button “+” to switch date, CO₂, CO₂24hAVG, CO₂1hMAX, CO₂24hMAX and CO₂MAX.
Note: PM1.0, PM2.5, PM4.0, PM10 reading on ecowitt APP or web page, but not display on console
When paired with other Console:
Configuration by built-in gateway of console, reading data on ecowitt APP or web page.
When uploaded to Ecowitt APP:
- Edit panel and title by “•••”.
- Tap “ ” to get graph of history data.
When uploaded to Ecowitt Weather Server:
- View current sensor data & history records & graph on the website.
- Set and receive email alerts from the server when alarm condition set under your account.
- Remote monitoring with smart phone, laptop, or computer by visiting the website.
Note: On the 48-hour self-test which takes place with maximum fan rotation and is therefore clearly perceptible. You can set the commissioning start time by removing the batteries and the USB connection to a point in time where the necessary fan noise does not interfere.
6. History data on ecowitt.net
Export history data: ecowitt.net – click “Export” button on the dashboard.
You can set the time period and data frequency for the data here.
The data will be exported in .csv format.
Clear history data: Under “menu” → “devices” → “•••” button to reset history data.
7. Sensor Placement & Mounting
Place the sensor on a horizontally surface. Note that the vents must be clear
of any obstructions, and we recommend placement away from other electronic
devices to prevent interference. Do not place on a metal table to prevent RF
signal loss.
Note: This sensor is designed for indoor use only.
Wireless communication is susceptible to interference, distance, walls and
metal barriers. We recommend the following best practices for trouble free
wireless communication.
- Electro-Magnetic Interference (EMI). Keep the console several feet away from computer monitors and TVs.
- Radio Frequency Interference (RFI). If you have other devices using the same RF frequency and communication is intermittent, try turning off these other devices for troubleshooting purposes. You may need to relocate the transmitters or receivers to avoid intermittent communication.
- Line of Sight Rating. This device is rated at 300feet line of sight (no interference, barriers or walls) but typically you will get 100 feet maximum under most real-world installations, which include passing through barriers or walls.
- Metal Barriers. Radio frequency will not pass through metal barriers such as aluminum siding. If you have metal siding, align the remote and console through a window to get a clear line of sight.
- Finally, please reset your sensor data on ecowitt.net and start using it.
Note:
This device is mainly used to detect the particle concentration in air. The
accuracy for temperature and humidity reading may vary due to different
environment:
When the sensor is placed at unventilated environment, the temperature reading
may be 2 degrees higher in worst case. When the sensor is placed at ventilated
environment, the temperature and humidity reading may be lower than the actual
reading.
8. Features
CO₂ and PM2.5 haze sensor
- CO₂ photoacoustic NDIR sensors are usually more mechanically and thermally robust.
- Measures indoor PM1.0, PM2.5, PM4.0, PM10, CO₂ concentration, Temperature and Humidity every 60 seconds when powered with USB or detecting every 10 minutes when powered with batteries only.
- USB power Connection for indoor use only.
- This CO₂ and PM2.5 haze sensor doesn’t has a display function and you need to view the data on weather server after pairing this device with our the WiFi Gateway or Console (all sold separately).
9. Specification
Model | WH46 |
---|---|
Name | CO₂ and PM2.5 haze sensor |
Types of CO₂ sensors | NDIR |
Dimensions: | 106×68×67(mm) |
Material of Plastic Casing | ABS |
Mass concentration range | 0 ug/m³ to 1000 ug/m³ |
Mass concentration precision for PM1 & PM2.5 | ±【5ug/m³+5%】(0 ug/m³ to 100 |
ug/m³), ±10 % (100 ug/m³ to 1000 ug/m³)
Mass concentration precision for PM4 & PM10| ±25 ug/m³ (0 ug/m³ to 100 ug/m³)
±25 % (100 ug/m³ to 1000 ug/m³)
Mass concentration resolution| 1 ug/m³
CO₂ measuring range| 0 to 40000 ppm
CO₂ measurement accuracy| ± (50 ppm + 5% of reading) when 400 to 2000 ppm
CO₂ Accuracy drift per year| ± (5ppm + 5% of reading)
CO₂ measurement resolution| 1 ppm
Temperature Metering Range| -10°C to 60°C (14°F to 140°F)
Temperature Metering Accuracy| ±0.8°C (1.5°F) when 15°C to 35°C (59°F to 95°F)
±1.5°C (2.7°F) when -10°C to 60°C (14°F to 140°F)
Temperature Metering Resolution| 0.1°C ( 0.1°F)
Humidity Metering Range| 1%RH to 99%RH
Humidity Metering Accuracy| ± 6%RH when 15°C to 35°C (59°F to 95°F)
± 9%RH when -10°C to 60°C (14°F to 140°F)
Humidity Metering Resolution| 1%RH
Humidity Accuracy drift per year| < 0.25%RH
Automatic cleanup interval| 2 days
Reading Update Interval| About 1 minute
RF Connection Frequency| 920/915/868/433MHz (depending on local regulations)
RF Wireless Range| Over 100 meters (in open areas)
Operating Temperature Range| -10°C to 50°C (14℉ to 122℉)
Power Supply| 2×1.5AA Batteries or USB 5V
Battery Life| 2 days
10.Carbon Dioxide Levels and potential health problems are indicated
below:
- 250-350 ppm: background (normal) outdoor air level.
- 350-1,000 ppm: typical level found in occupied spaces with good air exchange.
- 1,000-2,000 ppm: level associated with complaints of drowsiness and poor air.
- 2,000-5,000 ppm: level associated with headaches, sleepiness, and stagnant, stale, stuffy air; poor concentration, loss of attention, increased heart rate and slight nausea may also be present.
-
5,000 ppm: This indicates unusual air conditions where high levels of other gases also could be present. Toxicity or oxygen deprivation could occur. This is the permissible exposure limit for daily workplace exposures.
-
40,000 ppm: This level is immediately harmful due to oxygen deprivation.
Air Quality Index (AQI) for the PM2.5 Concentration (24hr)
AQI
| Air Pollution Level| PM2.5 Concentration ug/m3
---|---|---
0 – 50| Good|
0.0-12.0
51 -100
| Moderate| 12.1-35.4
101-150| Poor|
35.5-55.4
151-200
| Unhealthy| 55.5-150.4
201-300| Severe|
150.5-250.4
300+
| Hazardous|
250.5+
Air Quality Index (AQI) for the PM10 Concentration (24hr)
AQI
| Air Pollution Level| PM2.5 Concentration ug/m3
---|---|---
0 – 50| Good|
0-54
51 -100
| Moderate| 55-154
101-150| Poor|
155-254
151-200
| Unhealthy| 255-354
201-300| Severe|
355-424
300+
| Hazardous|
425+
Note:
The WH46 sensor data can be only viewed on the Live Data interface since it
doesn’t support uploads to weather underground. If you choose to upload the
data to our weather server: https://www.ecowitt.net, you can view the live
data/history graph and download the records on the website. You can add a
shortcut of the website on the home screen of your phone for quick access.
11. What types of NDIR sensors exist and how do they work?
An introduction to the principles behind transmissive and photoacoustic NDIR
sensing
Characteristics of NDIR Sensors:
NDIR sensing has become the prevalent technique for measuring CO₂
concentration. The technology exploits the characteristic property of CO₂
molecules to strongly absorb infra-red (IR) light with wavelengths around 4.2
µm. When shining light of this wavelength through a gas sample, the CO₂
concentration can thus be calculated from the proportion of light that is
absorbed. It is important to note that NDIR sensors do not require a
dispersive element, such as a prism or a diffraction grating, to discriminate
for the targeted wavelength. Instead, the light produced by the emitter is
shown through a non-dispersive band-pass filter, allowing only the infrared
wavelengths of interest to pass. These characteristics give the sensors their
classification: Non-dispersive Infra-red.
Transmissive NDIR:
These NDIR sensors typically feature an IR emitter and an optical detector,
such as a photodiode, at opposite ends of a specially designed optical cavity.
The optical detector measures the amount of IR light energy that is not
absorbed by (i.e., transmitted through) the gas sample.
As the CO₂ concentration in the optical cavity increases, the amount of light
detected decreases. Hence, this principle determines the amount of light
energy CO₂ molecules have absorbed by calculating the difference between the
measurement and a reference intensity at a known CO₂ concentration.
NDIR CO₂ sensors leverage infra-red absorption at 4.2 µm wavelength without the use of dispersive optical elements.
Absorption spectra of common trace gases
- Ammonia
- Carbon dioxide
- Carbon monoxide
- Methane
- Water
(HITRAN2016 molecular spectroscopic database)
Note that this reference value heavily depends on precise positioning of IR emitter and photodetector, as well as the emission properties of the IR source and the optical cavity. Mechanical and thermal stresses acting on the measurement chamber can thus significantly falsify CO₂ readings.
Furthermore, transmissive NDIR sensors generally require a minimal optical path length in the centimeter scale for enough IR absorption to occur to accurately measure lower CO₂ concentrations.
- Filter
- Photodetector
Photoacoustic NDIR:
In contrast to transmissive NDIR sensors, photoacoustic NDIR sensors detect the amount of energy that is absorbed by CO₂ molecules. When pulsing the infra-red emitter, CO₂ molecules absorb infra-red light periodically. This causes additional molecular vibration resulting in a pressure wave inside the measurement chamber. The higher the CO₂ concentration, the more light is absorbed, and thus the greater the amplitude of this acoustic wave becomes. A microphone inside the gas chamber measures this, from which the CO₂ concentration can then be calculated.
Photoacoustic NDIR sensing allows for much greater miniaturization of the measurement chamber. Furthermore, as sound waves are omnidirectional, relative positioning of emitter and microphone is unconstrained. Thus, photoacoustic NDIR sensors are usually more mechanically and thermally robust.
- Filter
- Microphone
12. CARE +MAINTENANCE
When batteries of different brand or type are used together, or new and old batteries are used together, some batteries may be over-discharged due to a difference of voltage or capacity. This can result in venting, leakage, and rupture and may cause personal injury.
- Do not mix Alkaline, Lithium, standard, or rechargeable batteries.
- Always purchase the correct size and grade of battery most suitable for the intended use.
- Always replace the whole set of batteries at one time, taking care not to mix old and new ones, or batteries of different types.
- Clean the battery contacts and also those of the device prior to battery installation.
- Ensure the batteries are installed correctly with regard to polarity (+ and -).
- Remove batteries from product during periods of nonuse. Battery leakage can cause corrosion and damage to this product.
- Remove used batteries promptly.
- For recycling and disposal of batteries, and to protect the environment, please check the internet or your local phone directory for local recycling centers and/or follow local government regulations.
Manufacture: ShenZhenShi OuSaiTeDianZi YouXianGongSi
Address: Shajingjiedao, Xihuanlu, Minzhujiujiugongyecheng AQu, C Dong 4
Ceng A, Shenzhen Baoanqu Guangdong 518101 CN
13. Warranty Information
We disclaim any responsibility for any technical error or printing error,
or the consequences thereof.
All trademarks and patents are recognized.
We provide a 1-year limited warranty on this product against manufacturing
defects, or defects in materials and workmanship.
This limited warranty begins on the original date of purchase, is valid only
on products purchased, and only to the original purchaser of this product. To
receive warranty service, the purchaser must contact us for problem
determination and service procedures.
This limited warranty covers only actual defects within the product itself and
does not cover the cost of installation or removal from a fixed installation,
normal set-up or adjustments, or claims based on misrepresentation by the
seller, or performance variations resulting from installation-related
circumstances.
14. Sensor Calibration
Auto Calibration Operation: If you find that the readings of the carbon dioxide sensor are inaccurate after a period of use, please place the device in a well-ventilated location for at least one day. Make sure there are no other sources of pollution around, and ensure that the sensor surface is not obstructed or affected by external interference. It is important to keep the device connected to the power supply and in normal working condition without shutting down or interrupting the power supply. By continuously detecting the carbon dioxide concentration in the environment, the sensor will automatically calibrate its readings.
If you have a reliable source to calibrate the CO₂ data, you may calibrate the offset on the Ecowitt App, or the console. If the deviation is large, it’s recommended to place the sensor in an outdoor ventilated place for 30 minutes before calibrating.
Open ecowitt APP → “•••” → ”Calibration” → “AQIN Calibration” → setting and save
15. After-sales Service
Order Issues:
If you encounter any missing or incorrect shipments of Ecowitt products purchased, please reach out to the respective platform’s customer service from the store you bought product for assistance.
Usage Inquiries:
For any issues related to product usage, feel free to con tact our customer support team at support@ecowitt.com. We are committed to providing assistance and resolving any concerns you may have.
16.Stay in Touch
Ask questions, watch setup videos, and provide feedback on our social media outlets. Follow Ecowitt on Discord, YouTube, Facebook and Twitter.
Designed by Ecowitt, Made in China, Printed in China
Documents / Resources
|
ecowitt WH46 NDIR CO and PM2.5 Haze
Sensor
[pdf] User Manual
WH46 NDIR CO and PM2.5 Haze Sensor, WH46, NDIR CO and PM2.5 Haze Sensor, PM2.5
Haze Sensor, Haze Sensor, Sensor
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>