DUCAR 102375156 Parallel Cable for iS Series Instruction Manual

June 10, 2024
DUCAR

DUCAR
PARALLEL CABLE for iS-series

Item number: 102375156
Ean: 6438014265117

SAFETY AND INSTALLATION

FOLLOW THESE INSTRUCTIONS CAREFULLY

Proper installation of the Parallel Cable is essential for safe and reliable operation.

WARNING!

This Parallel Cable Kit must ONLY be used between two identical Inverter Generators. Never connect cables between two different inverter generators, this may cause low voltage output, which can permanently damage the electrical devices connected to the inverter generators. Before use, read and understand the installation and operation instructions in this manual to become familiar with how this Parallel Cable Kit works with two Inverter Generators with parallel ports. Periodically inspect the cables for damage, replace cable if its insulation is broken or cracked.

INSTALLATION

  1. Connect the two parallel connectors (A) Fig.1 from one cable to the parallel inputs (B) on the control panel of the first Inverter Generator.
  2. Connect the two parallel connectors from the other cable to the parallel inputs on the control panel of the second Inverter Generator.
  3. Attach the ground wire (C) Fig.1 to the ground terminal (D) on the control panel of the first Inverter Generator.
  4. Attach the second ground wire to the ground terminal on the control panel of the second Inverter Generator.

OPERATION

Warning! If high electrical loads are connected, turn the generator’s ECO switch (A) Fig. 2 to the OFF position to reduce voltage changes. While both inverter generators are running, make sure both green power indication lights (B) are on. If not on, turn the inverter generators off, restart both inverter generators and make sure both green power indicator lights are on.

Warning! Substantial overloading (exceeding maximum power the rated out put of 50 Amps. Will shut off the AC output. Exceeding maximum power or slightly overloading the inverter generators may not switch the AC circuit protector off, but will shorten the service life of the inverter generators. Do not overload.

Warning! Only use one parallel cable receptable at a time. When using the paraller cable , the receptacles on the Inverter Generator control panels can not be used, only the receptacles on the Parallel Cable box can be used

2

Suomi Trading Oy
Areenakatu 7, 37570 Lempäälä
asiakaspalvelu@suomitrading.fi

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals