Electro-Magnetic Field Tester
Limited Guarantee and Liability
The guarantee period is one year after purchase date, which is not applicable
to fuse,batteries and damages caused by accidents, negligence, misuse, remodel
pollution.Distributors are not authorized to offer guarantee on behalf of our
company if maintenance service is needed during guarantee period, please
contact our company to get return authorization and return the product to with
problem descriptions. Except above circumstances, our company do not provide
and other explicit or implicit guarantee. such as an implicit guarantee for a
special purpose. Meanwhile we are not responsible for any other special,
indirect, collateral damages or losses based on speculations or other
reasons.As implied guarantee and collateral damages are restricted in some
countries or areas,
the above liability restrictions might not be applicable to you.
Brief Description
EMF tester is widely used in measuring electromagnetic field strength for home
appliances, such as TV, fan, electromagnetic oven.
This manual include relative safety and warning tips in product use. Please
read the manual carefully and follow accordingly.
Please note the measurement range before test.
Please read carefully the “Safety Operation Rules” before use the product.
Please make the measurement within the stated frequency range of the product.
Safety Operation Rules
- Please check the tester and accessories before use. If any damages non-display are found please do not use it again.
- Please follow the manual in test.
- Please do not open the test and change internal circuits.
- When low batteries icon is displayed please change batteries on time.(Please take out the batteries if it is not to be used for long time.
- Do not use or store the product in high temperature. high humidity high flammable.and high electromagnetic environments.
- Same external influence or misuse might cause inaccuracy or dis-function.
Illustrate:
If the EMF meter’s top light indicator is lighted and the screen has a digital
display, which means that the product is in the power-on state; if not,please
check whether the battery of the product is in the state of battery life
(replace a new battery, if necessary)
A: The magnetic field units are mG and uT.
B: The conversion unit is 10mG=1uT. The safety number of the electric field is
40V/M, if it exceeds this number, the light will turn yellow; when it reaches
400V/M, the light will turn red.
C: The unit of electric field is V/M (Newton/coulomb). The safety number of
the magnetic field is 0.4uT, if it exceeds this number, the light will turn
yellow; when it reaches 4.0uT, the light will turn red.
D: The default is to measure the magnetic field unit mG with sound when you
turn it on. Description of the LCD display area
1 | Low power indicator |
---|---|
2 | Max record |
3 | Alert sound icon |
4 | Data hold |
5 | mG unit |
6 | uT unit |
7 | Electric field unit |
8 | Main display area |
9 | Bar graph |
Button function:
- If you want to turn on /off, you need to press and hold for two seconds to turn on/off .If you don’t need the prompt sound, you can short press turn it off.
- If you want to switch the measurement between electric field and magnetic field, short press SEL to switch, as shown in the upper right corner of the screen, select electric field and magnetic field unit switching.
- In some special scenes, when the value cannot be monitored in real time or the value jumps too fast to see clearly, you can short press this button after approaching the measurement object to lock the value and get the measurement result without worrying about jumping.When you can’t see the measurement object clearly in a dark environment, you can press and hold it for two seconds to make the LED light on the back light up to illuminate the object
- If you want to know the maximum radiation emitted by an object, you can short-press this button to display the value as the peak value. You can long press when the value displayed on the screen cannot be seen clearly in a dark environment.
Specifications
EMF frequency range: 4HZ-300HZEMF
strength range: 0.1-199.9mG
Resolution: 0.1mGAlert threshold: >4.0mG
Accuracy: +/-20%
EMF strength range: 0.01-19.99uT
Resolution: 0.01uT
Alert threshold: >0.4uT
Accuracy: +-20%
Measurement Steps
- Press and hold this button for two seconds to power on.
- The SEL button switches to select the electric field and magnetic field measurement. The measurement unit in the upper right corner of the screen is mG and uT for the magnetic field, and V/M for the electric field.
Notes :
2.1. There is only electric radiation around some products, only magnetic
radiation around some products, and both exist around some productsThe
following is the laboratory test data for reference only, the actual test
shall prevail.
2.2. If you choose electric field measurement, there is no obvious number on
the display of this meter, please press the SEL button again to select the
magnetic field mode for measurement.
2.3. If there is no obvious change in the number/sound/indicator color (and
the indicator light on the top of the fuselage is on), please adjust the test
distance (close to the product test) for observation, and the data will be
obtained.
2.4. If there is no obvious number/sound/indicator color change (and the
indicator light on the top of the fuselage is on), and the distance is normal,
it means that there is no radiation around the product.
Electromagnetic radiation range of common household appliances
Product| Electric field vm Safety value 40| Magnetic field ut (mg /10) Safety
value 0.4
---|---|---
Television| 300 (The value measured by the radiation meter at a distance of 1m
from the TV is about 300)|
Router| 90| /
Refrigerator| 150| /
Electric Kettle| 260| 5.
Smoke Alarm| 280| 19.
Washing machine| 140| 2.9 ( In operation)
Lamp| 260| /
Computer| 290| /
Mobile Phone| | 0.4 ( Stand by)
280( in Charging )|
52| 1.68 ( In operation )
Hair Dryer| 400| 39
Electric Fan| 360| 6.
Vertical Air Conditioner| 317| /
Hair Dryer| 700| 0.3
Hanging-type air conditioner| 180| 0.35
3: Get close to the object you want to measure and get the final radiation value.
- Electric Field frequency range: 4HZ-3.5GHZ
- Electric Field Strength range: 1-1999V/M
Resolution: 1V/M
Alert threshold:>40V/M
Accuracy:+/-20%
- Power Supply:9V 6F22
- Measurement:189×53.8x35mm
- Weight: 128g (batteries not included)
Environment Limitations
- Altitude: 1800m
- Pollution Level: Class Il
- Working Temperature/humidity:0-40C/32-104F/45% -80%Rh
- Storage Temperature/humidity: 0-40C/32104F145%-80%RH
Friendly Reminder:
Under some circumstances, dangers might be incurred if this product is used in
strong radiation environment.
Battery Installation and Change
The 9V 6F22 batteries are used for this product. To change batteries,Please
open the battery cover and change batteries, Then close the battery cover.
Note: Do not reverse the battery polarity.
Accessories
- Instruction manual ……………1pac
- Guarantee card ……………….1pac
- 9V 6F22 battery ……………….1pac
lf the accessories are missing
Please contact us promptly