Sunco DL SL4 Ultra Slim Downlight User Manual
- June 16, 2024
- SUNCO
Table of Contents
Lighting made better.
User Manual
4” Ultra-Slim Downlight
Whats in the Box?
Slim Downligh
Why Plastic Junction Boxes?
At Sunco, our commitment to safety and reliability is at the core of our
lighting solutions, ensuring your eace of mind.
Plastic’s corrosion resistance ensures longer product lifespans with minimal
maintenance.
Plastic junction boxes are non-conductive, significantly helping prevent
potential fires.
Plastic junction boxes feature smooth edges, minimizing accidental cuts.
No need for a ground wire
Get Your Gear
Before You Start
Safety Informatxion
To reduce the risk of fire, electric shock, or physical injury:
-
Turn off circuit breaker before installing this fixture.
-
Professional installation required. Safety gear recommended.
-
Abide by regional and local laws or regulations.
-
Proper grounding is required to ensure safety.
-
Do not alter, or remove wiring during installation.
-
Do not make or alter any open holes in wiring enclosure or electrical components during installation.
-
Check for shipping damage before installing. If the product is damaged, do not use it.
-
Keep fixture away from corrosive substances.
-
Clean the fixture regularly to ensure proper operation.
Do not clean with harsh solvents. -
Suitable for damp locations at temperature ranging from 4°F to 113°F. Not for use where directly exposed to water.
-
Use safety precautions & abide by regional & local laws or regulations.
-
This product is not compatible with 3rd party sensors.
-
This product is not compatible with photo controls.
-
This product is not compatible with occupancy sensors.
-
This product is not compatible with timing devices.
WARNING:
Cancer & Reproductive Harm
www.P65Warnings.ca.gov
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference that may cause undesired operation. Please review all instructions carefully prior to installation.
Quickstart Guide
Step 1
Use template to cut hole.
Step 2
Connect supply & junction wires.
Step 3
Attach fixture to junction box. Step 4
Insert fixture into ceiling.
Installation Guide
STEP 1
a. Turn off circuit breaker before installation.
b. Cut out 4.33” housing size on Installation Template, then tape onto ceiling
in desired location.
c. Cut ceiling hole using Installation Template as a guide.
STEP 2
a. Open junction box and remove appropriate knockout.
STEP 3
a. Thread cable connector through knockout, secure wires with screws,
attach cable connector nut on opposite side, & connect supply & junction wires
with wire nuts.
-Black to Black (Live) ; White to White (Neutral)
b. Tuck connected wires inside junction box & close cover.
STEP 4
Note: This step applies exclusively to the Selectable Slims.
Slide the CCT Switch to choose from 5 color temperatures.
Insert junction box through ceiling hole.
New Construction: Secure to studs, joists, or similar fixed structural units.
Remodel: Do not require to secure to studs, joists, or similar fixed units.
STEP 5
a. Attach fixture to junction box using connector as shown on image (1).
b. Tighten connector by hand (2). STEP 6
a. Push up spring clips and insert fixture into ceiling.
b. Turn on circuit breaker and test light.
Product Details
Recommended Dimmers
Brand | Model |
---|---|
LUTRON | P-PKG1WB-WH |
LUTRON | PD-6WCL-WH |
LUTRON | AYCL-153P-WH |
LUTRON | DVCL-153P-WH |
LUTRON | D26HD-2RW |
LEVITON | HS220 |
KASA SMART | HS220P3 |
KASA SMART | MACL-153M-WH |
https://qrco.de/be5AyS
Specifications
Voltage | 120V |
---|---|
Wattage | 10W |
Frequency | 60Hz |
Beam Angle | 90° |
Weight | 0.41lbs |
Housing Material | Plastic |
Dimmable | Ye s |
Average Lifetime | 50,000 hrs |
Lumens | 650LM |
Moisture Rating | Damp |
CRI | 80+ |
Usage | Indoor |
IC Rated | Ye s |
Warranty | 7 Years |
Common Troubleshooting
We’ve got you covered! Our troubleshooting section is here to shed some light
and provide you with easy-to-follow solutions for any problem.| If you still
need some assistance, feel free to contact us. Our team of lighting experts
are happy to help brighten your day.
---|---
Light isn’t turning on.
Installation| Double check if fixture is properly connected and circuit
breaker hasn’t been tripped.
Light unexpectedly fails.| . Check that the lights are not overloading the
circuit.
Light not dimming to lowest setting.
Dimming| Verify dimmer switch compatibility.
Light not dimming smoothly.| Check light-dimmer compatibility.
Light not compatible with dimmer switch.| Verify dimmer compatibility with
fixture.
Light is flickering when turning on.
Flickering| Verify light is connected to surge protector securely.
Light flickering with other lights on the same circuit.| Verify fixture
compatibility.
Light flickering when turned on.| Check that fixture wiring connections are
secure.
Light flickering when dimmed.| Reach out to customer support.
Buzzing Fixture buzzing with power outages.
Buzzing| Ensure minimum dimmer load requirement is met.
Fixture buzzing with power outages.| Look for nearby interferences that can
cause buzzing. Such as televisions, radios, computers, etc.
Buzzing| Verify dimmer switch compatibility.
Light Distribution Angle
Lighting distribution angle refers to the spread of light emitted from a light source. It is an important factor to consider when selecting a fixture or bulb, as it affects the way it will illuminate an area. There are two main types of lighting distribution angles: A symmetric lighting distribution emits light evenly in all directions, creating a coneshaped pattern that provides a pool of light. This type of lighting is ideal for general lighting and illuminating large areas. Common applications for symmetric lighting include general area illumination, security lighting, and perimeter lighting. Symmetric lighting is also used to a certain degree in up-lighting. An asymmetric lighting distribution angle, also known as beam angle, creates a pattern that focuses light in a specific direction. This type of lighting is ideal for task lighting as it reduces glare and light spill in other areas. Common applications include task lighting in spaces such as landscape settings, retail stores, museums, and much more. It is important to note that the lighting distribution angle can also be affected by other factors such as the reflector design of the light source, the type of lens used, and the distance between the light source and the surface being illuminated.
Customer Support
Warranty Policy
This product is covered by our industry leading 7 year warranty.
It gets even better – scan the QR code for 2 extra years of protection!
30 Day Return Policy
At Sunco we value our customers and stand by the quality and performance of
our products.
If you are not completely satisfied with your purchase, we accept returns
within 30 days of your purchase date.
Customer Service
Our Los Angeles team of lighting experts is here to assist you with all your
needs! Contact us at:
Email: support@sunco.com
Call or text: 844-334-9938
Lighting made better.
support@sunco.com
844-334-9938
AMERICAN COMPANY
REV1.0
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>