nVent HOFFMAN RBT7101HA LENTON T Series Horizontal Sleeve Instructions
- June 16, 2024
- nVent HOFFMAN
Table of Contents
nVent HOFFMAN RBT7101HA LENTON T Series Horizontal Sleeve
Product Information
Specifications
- Product Name : T-Series Horizontal Sleeve
- Fill Type : Top Fill
- Diameter : 22 mm
- Catalog Number : RBT7101HA
- Length : 127 mm
Features
- Designed to connect horizontal reinforcing bars and angular reinforcing bars up to 45 degrees
- Used to splice the same diameter bars
- Works with saw cut, flame cut, and sheared bars
- Can be visually inspected after installation
- Available with extended sleeve lengths
Additional Product Details
Prior to installation, please read and understand all of the detailed instructions and safety notices provided in the nVent LENTON Cadweld Rebar Splicing System Instruction Manual. Sizes notshown may be available by special order. Contact your nVent LENTON representative for more information. RBT51012HA does not have vent holes.
Diagrams
No diagrams provided in the user manual.
Product Usage Instructions
Step 1: Pre-installation Preparation
Before installing the T-Series Horizontal Sleeve, ensure you have read and understood all the detailed instructions and safety notices provided in the nVent LENTON Cadweld Rebar Splicing System Instruction Manual.
Step 2: Selecting the Correct Sleeve Length
Choose the appropriate sleeve length based on your specific requirements. The T-Series Horizontal Sleeve is available in standard lengths, as well as extended lengths.
Step 3: Cleaning and Preparing the Rebar
Thoroughly clean and prepare the ends of the reinforcing bars that need to be spliced. Remove any rust, scale, or contaminants that may affect the quality of the splice.
Step 4: Inserting the Rebar into the Sleeve
Insert one end of the reinforcing bar into the T-Series Horizontal Sleeve. Ensure that the bar is fully inserted and centered within the sleeve.
Step 5: Filling the Sleeve
Fill the top opening of the sleeve with an appropriate splicing material. Follow the manufacturer’s instructions for the specific splicing material being used.
Step 6: Inspecting the Installation
After filling the sleeve, visually inspect the installation to ensure that the splicing material is properly distributed and there are no visible defects or air entrapment.
Step 7: Post-Installation Testing
Perform any required post-installation testing or inspections as specified by the relevant building codes or engineering standards.
Step 8: Repeat for Additional Splices
If you need to splice multiple reinforcing bars, repeat steps 3 to 7 for each splice.
FAQ
- Q: Are different sleeve lengths available?
- A : Yes, the T-Series Horizontal Sleeve is available in both standard lengths and extended lengths. Contact your nVent LENTON representative for more information on available options.
- Q: Can I use the T-Series Horizontal Sleeve with bars cut by different methods?
- A : Yes, the T-Series Horizontal Sleeve can be used with saw cut, flame cut, and sheared bars.
- Q: Is the installation of the T-Series Horizontal Sleeve visually inspectable?
- A : Yes, the T-Series Horizontal Sleeve can be visually inspected after installation to ensure proper filling and no visible defects.
CATALOG NUMBER RBT7101HA
The top fill horizontal T-Series sleeve has vent holes to reduce air entrapment and help ensure proper filling of the sleeve.
FEATURES
- Designed to connect horizontal reinforcing bars and angular reinforcing bars up to 45 degrees
- Used to splice the same diameter bars
- Works with saw cut, flame cut and sheared bars
- Can be visually inspected after installation
- Available with extended sleeve lengths
PRODUCT FEATURES
Material: Acciaio
Finish : Piano
100% U.S. Domestic Content : Sì
Sleeve : Standard Length
Rebar Size, Metric : 22 mm
Rebar Size, US : #7
Diameter 1 : 41 mm
Diameter 2 : 29 mm
Length 1 : 127 mm
Length 2 : 64 mm
Length 3 : 20 mm
Unit Weight : 0,69 kg
Designed to Meet : AASHTO; ABNT NBR 8548:1984; ACI 318 Type 1 (125%
Specified Yield); ACI 318 Type 2 (Specified Tensile);
ACI 349; ACI 359; AS3600; CAN/CSA – N287.2/.3/.4; IBC Type 1 (125%
Specified Yield); IBC Type 2 (Specified Tensile); US Army
ADDITIONAL PRODUCT DETAILS
Prior to installation, please read and understand all of the detailed instructions and safety notices provided in the nVent LENTON Cadweld Rebar Splicing System Instruction Manual. Sizes not shown may be available by special order. Contact your nVent LENTON representative for more information. RBT51012HA does not have vent holes.
DIAGRAMS
-
America del Nord
+1.800.753.9221 -
Option 1 – Customer Care
-
Option 2 – Technical Support
Europa
- Netherlands: +31 800-0200135
- France: +33 800 901 793
Europa
- Germany : 800 1890272
- Other Countries : +31 13 5835404
APAC
- Shanghai: + 86 21 2412 1618/19
- Sydney : +61 2 9751 8500
- Our powerful portfolio of brands:
- CADDY ERICO HOFFMAN RAYCHEM SCHROFF TRACER
- nVent.com
© 2024 nVent. All nVent marks and logos are owned or licensed by nVent
Services GmbH or its affiliates. All other trademarks are the property of
their respective owners.
nVent reserves the right to change specifications without notice.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>