REVOPOINT WPS 1602718042 Range 2 3D Scanner User Guide Specifications Product Profile System Requirements Product Usage Instructions FAQ
- January 19, 2024
- REVOPOINT
Table of Contents
- WPS 1602718042 Range 2 3D Scanner
- Specifications
- Product Profile
- System Requirements
- Product Usage Instructions
- I. Connecting RANGE 2 to a PC via USB Cable
- II. Connecting RANGE 2 to a PC via Wi-Fi
- III. Connecting RANGE 2 to Android Phones via USB Cable
- IV. Connecting RANGE 2 to Android or iOS Phones via Wi-Fi
- FAQ
- Q: Where can I download the Revo Scan software?
- Q: What is the operating environment temperature range for the
- Q: What are the connection modes supported by the RANGE 2 3D
WPS 1602718042 Range 2 3D Scanner
Specifications
- Product Name: RANGE 2 3D Scanner
- Version: V1.0
- Operating Environment Temperature Range: 0°C to 40°C (32°F to
104°F)
Product Profile
The Revopoint RANGE 2 3D scanner is a high-quality scanner
designed for capturing detailed 3D scans. It offers versatile
connectivity options and is compatible with various operating
systems, including Windows, macOS, Android, and iOS.
System Requirements
Please ensure that your device meets the following system
requirements before using the RANGE 2 3D scanner:
-
Windows: Win 10/11 (64-bit), RAM: 8GB or better, Processor:
Intel Core i5 10th Gen or better -
Mac with Intel x86 chip: macOS 10.15 and models after, RAM: 8GB
or better -
Mac with Apple M1/M2 chip: macOS 11.0 and models after, RAM:
8GB or better -
Android: Android 9.0 or better, RAM: 6GB or better
-
iPhone: iPhone 8 Plus or models after
-
iPad: 6th generation iPad or models after, System Version: iOS
13.0 or better
Product Usage Instructions
I. Connecting RANGE 2 to a PC via USB Cable
-
Connect the Tripod to the scanner.
-
Use the USB Type-A to C Cable to connect the scanner to a PC.
If your PC does not have a USB Type-A port, use the USB Type-C
Adapter. -
Open Revo Scan software. Wait for the software to show “Scanner
Connected” and the scanner’s indicator to turn solid blue.
II. Connecting RANGE 2 to a PC via Wi-Fi
-
Screw the scanner onto the Power Bank Handle.
-
Use the USB Type-A to C Cable to connect the scanner and Power
Bank Handle. When the scanner’s indicator turns solid green, it’s
powered. -
Search for a Wi-Fi network called “RANGE 2-REVO-XXXXXXXX” in
your PC’s Wi-Fi settings, and connect (no password is
required). -
Open Revo Scan software. Wait for the software to show “Scanner
Connected” and the scanner’s indicator to turn solid blue.
III. Connecting RANGE 2 to Android Phones via USB Cable
-
Attach the Quick Release Plate, Phone Holder, and Power Bank
Handle to the scanner. -
Put a phone in the Phone Holder, and use the 2-in-1 Mobile
Cable to connect to the ports shown. When the scanner’s indicator
turns solid green, it’s powered. -
Open Revo Scan software. Wait for the software to show “Scanner
Connected” and the scanner’s indicator to turn solid blue.
IV. Connecting RANGE 2 to Android or iOS Phones via Wi-Fi
-
Attach the Quick Release Plate, Phone Holder, and Power Bank
Handle to the scanner. -
Put a phone in the Phone Holder, and use the USB Type-A to C
Cable or 2-in-1 Mobile Cable to connect the scanner to the Power
Bank Handle. When the scanner’s indicator turns solid green, it’s
powered. -
Open Revo Scan software. Wait for the software to show “Scanner
Connected” and the scanner’s indicator to turn solid blue.
FAQ
Q: Where can I download the Revo Scan software?
A: For Windows and macOS users, visit the Support section on
Revopoint’s website at www.revopoint3d.com to download
the
software. Smartphone users can find Revo Scan on Google Play or the
Apple App Store to download.
Q: What is the operating environment temperature range for the
RANGE 2 3D scanner?
A: The operating environment temperature range is 0°C to 40°C
(32°F to 104°F). Please operate the product within this temperature
range.
Q: What are the connection modes supported by the RANGE 2 3D
scanner?
A: The RANGE 2 3D scanner supports USB and Wi-Fi connection
modes. USB connection is available for Windows, macOS, and Android
devices, while Wi-Fi connection is available for Windows PCs.
RANGE 2 3D SCANNER
Quick Start Guide
V1.0
Thank you for choosing the Revopoint 3D scanner! Please carefully read this
guide before your first scan.
Begin by downloading the Revo Scan software for your RANGE 2 3D Scanner. For
Windows and macOS users, visit the Support section on Revopoint’s website at
www.revopoint3d.com to download. Smartphone users, find Revo Scan on Google
Play or the Apple App Store to download.
Please keep the scanner away from water and any other liquids, and avoid
bashing the scanner. This product’s operating environment temperature range is
0 to 40 (32 to 104 ). Please
operate the product appropriately and only in situations limited to this
temperature range.
Table of Content
What’s in the
Box?……………………………………………………………………………………………………………………………………………………………………………..1
Product
Profile……………………………………………………………………………………………………………………………………………………………………………………2
System Requirements
……………………………………………………………………………………………………………………………………………………………………3 Scanner
Connection ……………………………………………………………………………………………………………………………………………………………………… 3
I. Connecting RANGE 2 to a PC via USB
Cable……………………………………………………………………………………………………………… 4 II. Connecting RANGE 2 to a
PC via Wi-Fi…………………………………………………………………………………………………………………………5 III. Connecting
RANGE 2 to Android Phones via USB Cable……………………………………………………………………………………. 7 IV.
Connecting RANGE 2 to Android or iOS Phones via Wi-
Fi………………………………………………………………………………… 9 Scanning Tips
…………………………………………………………………………………………………………………………………………………………………………………….11 Your
First
Scan………………………………………………………………………………………………………………………………………………………………………………….13 I.
Your First Scan Using Revo Scan
(PC)………………………………………………………………………………………………………………………….13 II. Your First Scan
Using Revo Scan (Android)……………………………………………………………………………………………………………..15 III.
Your First Scan Using Revo Scan
(iOS)………………………………………………………………………………………………………………………18 Sharing Models from a
Phone to a PC………………………………………………………………………………………………………………………….. 20
What’s in the Box?
1
Product Profile
2
System Requirements
Please download the Revo Scan software before your first scan. The system requirements are as follows:
Windows: Win 10/11 (64-bit) RAM: 8GB or better Processor: Intel Core i5 10th Gen or better Mac with Intel x86 chip: macOS 10.15 and models after Mac with Apple M1/M2 chip: macOS 11.0 and models after RAM: 8GB or better
Android: Android 9.0 or better RAM: 6GB or better
iPhone: iPhone 8 Plus or models after iPad: 6th generation iPad or models
after System Version: iOS 13.0 or better
Scanner Connection
Connection Modes
System
PC
Phone
Mode
Windows
macOS
Android
iOS
USB
×
Wi-Fi
3
I. Connecting RANGE 2 to a PC via USB Cable
Step 1: Connect the Tripod to the scanner.
Step 2: Use the USB Type-A to C Cable to connect the scanner to a PC. When the
scanner’s indicator turns solid green, it’s powered.
Note: If your PC does not have a USB Type-A port, use the USB Type-C Adapter.
4
Step 3: Open Revo Scan, when the software shows Scanner Connected and the
scanner’s indicator turns solid blue, it’s ready.
II. Connecting RANGE 2 to a PC via Wi-Fi
Step 1: Screw the scanner onto the Power Bank Handle.
5
Step 3: Search for a Wi-Fi network called RANGE 2-REVO-XXXXXXXX in your PC’s Wi-Fi settings, and connect (no password is required).
Step 2: Use the USB Type-A to C Cable to connect the scanner and Power Bank
Handle. When the scanner’s indicator turns solid green, it’s powered.
6
Step 4: Open Revo Scan, when the software shows Scanner Connected and the
scanner’s indicator turns solid blue, it’s ready.
III. Connecting RANGE 2 to Android Phones via USB Cable
Step 1: Attach the Quick Release Plate, Phone Holder, and Power Bank Handle to
the scanner.
7
Step 3: Open Revo Scan, when the software shows Scanner Connected and the scanner’s indicator turns solid blue, it’s ready.
Step 2: Put a phone in the Phone Holder, and use the 2-in-1 Mobile Cable to
connect to the ports shown. When the scanner’s indicator turns solid green,
it’s powered.
Note: The 2-in-1 Mobile Cable can only be used to connect the scanner and
phones.
8
IV. Connecting RANGE 2 to Android or iOS Phones via Wi-Fi
Step 1: Attach the Quick Release Plate, Phone Holder, and Power Bank Handle to
the scanner.
Step 2: Put a phone in the Phone Holder, and use the USB Type-A to C Cable or
2-in-1 Mobile Cable to connect the scanner to the Power Bank Handle. When the
scanner’s indicator turns solid green, it’s powered.
9
Step 3: Search for a Wi-Fi network called RANGE 2-REVO-XXXXXXXX in your
smartphone’s Wi-Fi settings, and connect (no password is required).
Step 4: Open Revo Scan, when the software shows Scanner Connected (iOS devices
will show the scanning preview window) and the scanner’s indicator turns solid
blue, it’s ready.
10
Scanning Tips
Please scan indoors and ensure only the object to be scanned is shown in the
Depth Cameras’ preview window. Use the Large Calibration-board Sheet to help
if necessary. Ensure the object is evenly lit if you need a color model.
Use scanning spray when scanning transparent, dark, and reflective objects.
Note: Scanning spray can be purchased from the Revopoint Store on our website.
Please stick markers irregularly on the object’s surface or use the Magic Mat
when scanning featureless objects like balls and cylinders, and choose Marker
Tracking in Scan Settings – Tracking Mode in Revo Scan.
11
Please aim the scanner at the object to be scanned, hold it steady and move
slowly during your scan. The distance between the scanner and the object can
be between 400 1300 mm. In the 3D scanning interface in Revo Scan, refer to
the distance indicator bar to ensure an excellent distance between the scanner
and the object.
Note: The scanning accuracy may be affected if the scanner is bashed by
accident. In this case, please get in touch with us to help you recalibrate
the scanner with the Calibration Board. If the accuracy still cannot reach the
standard accuracy after recalibration, please return the scanner for repair.
12
Your First Scan
I. Your First Scan Using Revo Scan (PC) After the scanner is connected, click
the New Project button on Revo Scan’s Home Page, then set parameters and start
your scan using the following steps:
Please refer to the interface of Revo Scan. 13
Choose Accuracy, Tracking Mode, and Object Type according to your requirements.
Toggle Color Scanning if you need a color model.
Move the scanner closer or further away from the object until the scanning distance indicator bar shows Excellent or Good.
Click the
button for the Depth Cameras’ exposure to be set automatically, or you can turn off
the
exposure and change the exposure by dragging the slider until there are as few blue and
red areas on the object in the Depth Camera preview window as possible.
You also must adjust the RGB Camera’s exposure when doing a color scan. Click the
button
for the exposure to be set automatically, or you can turn off the
exposure and adjust the
exposure by dragging the slider until the object’s color in the RGB preview window is clear and
sharp.
Click the
button to begin your scan. While scanning, hold the scanner steady and move
slowly. Try not to scan the same areas repeatedly. You can click the
button to stop and
check your model anytime during your scan. If the model is incomplete, click the
button to
continue your scan. Click the
button to finish the scan when the model is complete.
Click One-click Edit to process the model automatically, or manually edit the model using the Fusion, Mesh, Texture (only for color models) settings, and other tools if you need a more detailed model.
After post-processing, export the model in PLY, OBJ, or STL formats.
14
II. Your First Scan Using Revo Scan (Android)
Open Revo Scan on your phone and tap the New Project button. Choose Accuracy,
Tracking Mode, and Object Type according to your needs. Choose Color in
Texture if you need a color model. Tap the Start Scanning button to enter the
scanning preview window.
15
Move the scanner closer or further away from the object until the scanning distance indicator bar shows Excellent or Good.
Tap the icon in the Depth Camera preview window to adjust the Depth Cameras’ exposure until there are as few blue and red areas on the object in the preview window as possible.
You must also adjust the RGB Camera’s exposure when doing a color scan. Tap the
icon in the
RGB Camera preview window and adjust the exposure until the object’s color in the preview window
is clear and sharp.
Tap the
icon to start scanning. While scanning, hold the scanner steady and move slowly. Try
not to scan the same areas repeatedly. Tap the
button to finish the scan and enter the
post-processing window when the scan is over.
16
Tap the
icon to fill holes in the model (optional).
Tap the Post-processing button for Fusing and Meshing. You can share the model to Revo Scan on your PC for more editing options. See Sharing Models from a Phone to a PC on page 20 of this guide for details.
17
III. Your First Scan Using Revo Scan (iOS)
Tap the
icon to choose Accuracy, Tracking Mode, and Object Type. Toggle Color Scanning if
you need a color model.
Move the scanner closer or further away from the object until the scanning distance indicator bar shows Excellent or Good.
Tap the
button for the Depth Cameras’ exposure to be set automatically, or you can turn off
the
exposure and change the exposure by dragging the slider until there are as few blue
and red areas on the object in the Depth Camera preview window as possible.
18
You also must adjust the RGB Camera’s exposure when doing a color scan. Tap the
button
for the exposure to be set automatically, or you can turn off the
exposure and adjust the
exposure by dragging the slider until the object’s color in the RGB preview window is clear and
sharp.
Tap the
button to start your scan. While scanning, hold the scanner steady and move slowly.
Try not to scan the same areas repeatedly.
Tap the
button to finish the scan and enter the post-processing window when the scan is over.
Tap the
icon to fill holes in the model (optional).
Tap the Post-processing button to automatically process the model. You can share the model to Revo Scan on your PC for more editing options.
19
Sharing Models from a Phone to a PC
Open Revo Scan on your PC and click the New Project button.
Choose File – Import from Phone on the Menu Bar.
Open Revo Scan on your phone and find the project to transfer.
Tap the share icon and enter the share page (see the image on the right).
Enter the code or scan the QR code displayed on the PC.
Wait for the project to be transferred.
Note: The phone and PC must be connected to the same network while transferring.
To learn more scanning skills, go to the Download page in the Support section
on Revopoint’s website, www.revopoint3d.com, to get the latest Quick Start
Guide and User Manual. You can also follow our YouTube account, Revopoint 3D,
for tutorial videos. This content is subject to change. Please refer to the
latest version.
20
Follow Us:
Contact Us:
Scan the QR code left with your phone and contact us for help.
©2023 REVOPOINT 3D ALL RIGHTS RESERVED
IC Warning This device complies with Industry Canada’s licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil nedoit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. IC RF Statement: When using the product, maintain a distance of 20cm from the body to ensure compliance with RF exposure requirements. Déclaration IC RF: Lors de l’utilisation du produit, maintenez une distance de 20 cm du corps pour garantir conformité aux exigences d’exposition aux RF.
FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>