BOSCH DWZ1BK1I6 Clean Air Plus Recirculation Kit Installation Guide

June 16, 2024
Bosch

BOSCH DWZ1BK1I6 Clean Air Plus Recirculation Kit

BOSCH-DWZ1BK1I6-Clean-Air-Plus-Recirculation-Kit-product-
image

Product Information

Specifications

  • Model Number : 9001831644
  • Date : 031120

General Information
The product comes with a set of instructions for safe installation and usage. It is important to follow these instructions to ensure proper functioning and avoid any potential risks.

Safe Installation
When installing the product, it is important to observe the safety instructions provided. Failure to do so may result in accidents or injuries. Here are some key points to consider

  • Do not let children play with packaging material to avoid the risk of suffocation.
  • Components inside the appliance may have sharp edges, so it is advisable to wear protective gloves during installation.

Included with the Appliance
After unpacking the appliance, check for any damage during transit and ensure that all parts are complete. Refer to Fig. 1 and Fig. 2 for visual references.

Fitting the Air Recirculation Deflector
To fit the air recirculation deflector, follow these steps

  1. Remove the flue duct as per the installation instructions for your appliance.
  2. Insert the circulating-air guide into the angle brackets. Refer to Fig. 3 and Fig. 4 for visual references.
  3. Secure the hose to the circulating-air guide and the air-pipe connector using the provided hose clips. Refer to Fig. 5 for a visual reference.
  4. Tighten and adjust the hose length if necessary.
  5. Fit the flue duct, ensuring that the slots on the inner flue duct section point upwards. Refer to the installation instructions for your appliance for more details on flue duct installation.

Odour Filter for Circulating-Air Mode
The odour filter is designed to bind odorous substances in air recirculation mode. Regular replacement of the odour filter is important to maintain a high level of odour removal. The filter should be replaced every 12 months with normal use (approximately one hour a day). Please note that the odour filter cannot be cleaned or regenerated.

Replacing the Odour Filter
To replace the odour filter, follow these steps

  1. Open the glass plate.
  2. Remove the grease filters as per the operating instructions for your appliance.
  3. Position the large odour filters at the bottom and swing them up, making sure to compress the foam when inserting. Refer to Fig. 6 for a visual reference.
  4. Position the small filter at the back and swing it up. Refer to Fig. 7a for a visual reference.
  5. Install the grease filters. Refer to Fig. 8 for a visual reference.
  6. Close the glass plate.

FAQ

  • Q: How often should I replace the odour filter?
    A: The odour filter should be replaced every 12 months with normal use (approximately one hour a day).

  • Q: Can I clean or regenerate the odour filter?
    A: No, the odour filter cannot be cleaned or regenerated. It should be replaced with a new one.

General information

  • Read this instruction manual carefully.
  • Keep the instruction manual and the product information safe for future reference or for the next owner. The appliance can only be used safely if it is correctly installed according to the safety instructions. The installer is re- sponsible for ensuring that the appliance works perfectly at its installation location.
  • This instruction manual is intended for the installer of the optional accessory.
  • Only a licensed expert may connect the appliance. • Switch off the power supply before carrying out any work.

Safe installation

Observe the safety instructions when installing the optional accessory.

WARNINGRisk of suffocation!
Children may put packaging material over their heads or wrap themselves up in it and suffocate.

  • Keep packaging material away from children
  • Do not let children play with packaging material.

WARNINGRisk of injury!
Components inside the appliance may have sharp edges.
Wear protective gloves.

Included with the appliance
After unpacking all parts, check for any damage in transit and completeness of the delivery.
→ Fig. I, → Fig. 2

Fitting the air recirculation deflector

  1. Remove the flue duct. You can find information on how to remove the flue duct in the installation instructions for your appliance.
  2. fit the circulating air guide into the angle brackets.
  3. Use the 2 hose clips to secure the hose to the circulating-air guide and the air-pipe connector. → Fig. 5
  4. Tighten and, if required, shorten the hose.
  5. Fit the flue duct. The slots on the inner flue duct section point up- wards.
    You can find information about the installation of the flue duct in the installation instructions for your appliance.

Odour filter for circulating-air mode
Odour filters bind odorous substances in air recirculation mode. Regularly replaced odour filters guaran- tee a high level of odour removal. With normal use (approx. one hour a day), the odour filter must be replaced every 12 months. The odour filter cannot be cleaned or regenerated.

Replacing the odour filter

  1. Open the glass plate.

  2. Remove the grease filters.
    You can find information about removing the grease filters in the operating instructions for your appliance.

  3. Position the large odour filters at the bottom1 and swing them up 2
    → Fig. 6
    The foam must be compressed when you insert it.

  4. Position the small filter at the back 1 and swing it up 2

  5. → Fig. 7
    The odour filters have been installed.

  6. Install the grease filters.
    → Fig. 8

  7. Close the glass plate.