YouBest ZM2033 Smart Toilet Instructions

June 16, 2024
YouBest

YouBest ZM2033 Smart Toilet

APPLICATION FOR APPLIANCE EFFICIENCY REGULATIONS

On Behalf of
Quanzhoushi Tuomo Dianzishangwu Co., Ltd
Smart Toilet
Model No.: ZM2033

Prepared for : Quanzhoushi Tuomo Dianzishangwu Co., Ltd Chidianzhen QiaonanshequWangjianglu163hao Jinjiangshi Fujiansheng 362212

Prepared By : Shenzhen Youbest Testing Technology Co., Ltd. 202, Building 3, No.111 Huanguan Middle Road, Songyuanxia Community, Guanhu Street, Longhua District, Shenzhen, Guangdong, China

Date of Test: August 20, 2023
Date of Report: August 20-28, 2023
Report Number: YB230801035N

Test Report

Energy Efficiency Regulations
Energy Conservation Program For Plumbing Fittings

Report Number………………………….: YB230801035N
Test by (print+signature)……………: Mark Zhao
Checked by (print+signature) …….: Ken Pang
Approved by (print+signature) …..: Collin Zhou
Date of issue …………………………….: August 28, 2023

Testing Laboratory name…………..: Shenzhen Youbest Testing Technology Co., Ltd.
Address ……………………………………: 202, Building 3, No.111 Huanguan Middle Road, Songyuanxia Community, Guanhu Street, Longhua District, Shenzhen, Guangdong, China
Testing location ………………………..: Same as above

Applicant’s name………………………: Quanzhoushi Tuomo Dianzishangwu Co., Ltd
Address ……………………………………: Chidianzhen QiaonanshequWangjianglu163hao Jinjiangshi Fujiansheng 362212

Test specification:

Standard …………………………………..: U.S. California Code of Regulations Title 20. Public Utilities and Energy – CEC-140-2019-002, December 2019: Plumbing Fixtures.
Test procedure………………………….: Test Method for Dual-Flush Water Closet: 10 C.F.R. Section 430.23(u) (Appendix T to subpart B of part 430) – Uniform Test Method for Measuring gallons per flush of water closets Section 7.10 of ASME A112.19.2/CSA B45.1-2013-Waste Extraction Test for Water Closets.
Non-standard test method …………: N/A

Test Report Form No…………………: CEC-2021-03
Test Report Form(s) Originator ….: Youbest
Master TRF ……………………………….: 2021-03B

Test item description…………………: Smart Toilet
Trade Mark………………………………..: ZAHEES
Manufacturer…………………………….: JJJK
Address ……………………………………: Chidianzhen QiaonanshequWangjianglu163hao Jinjiangshi Fujiansheng 362212
Factory (ies) …………………………….: JJJK
Address ……………………………………: Chidianzhen QiaonanshequWangjianglu163hao Jinjiangshi Fujiansheng 362212
Model/Type reference………………..: ZM2033
Model difference ……………………..: N/A
Ratings……………………………………..: See marking plate

General Remarks

The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.
“(see remark #)” refers to a remark appended to the report.
“(See appended table)” refers to a table appended to the report.
Throughout this report a point is used as the decimal separator.

Abbreviations May Used throughout This Report

  • UUT: Unit Under Test
  • WD: Dual-Flush Water Closet
  • UP: Prison-Type Urinal
  • WE: Electromechanical Hydraulic
  • UT: Trough-Type Urinal
  • WF: Flushometer Valve Water
  • UV: Vacuum-Type Urinal
  • WG: Gravity Tank-Type Water
  • UW: Waterless Urinal
  • WP: Prison-Type Water Closet
  • UM: Wall-mounted Urinal
  • WT: Flushometer Tank Water Closet
  • UN: Other Type Urinal
  • WV: Vacuum-Type Water Closet
  • WB: Blowout Water Closet
  • N.A.: Not Applicable

Summary of Test conditions (According to the standard ASME A112.19.2- 2018/CSA B45.1-2013)

Test Apparatus and General Instructions
a. When testing a water closet, use the test apparatus and follow the instructions specified in Sections 7.1.1 (including Table 5), 7.1.2, 7.1.3, 7.1.4, and 7.1.5 of ASME A112.19.2–2018). The flushometer valve used in the water consumption test must represent the maximum design flush volume of the water closet. Record each measurement at the resolution of the test apparatus. Round each calculation of water consumption for each tested unit to the same number of significant digits as the previous step.
b. When testing a urinal, use the test apparatus and follow the instructions specified in Sections 8.2.1, 8.2.2, and 8.2.3 (including Table 6) of ASME A112.19.2–2018. The flushometer valve used in the water consumption test must represent the maximum design flush volume of the urinal. Record each measurement at the resolution of the test apparatus. Round each calculation of water consumption for each tested unit to the same number of significant digits as the previous step.
Test Measurement
a. Water closets:
(i) Measure the water flush volume for water closets, expressed in gallons per flush (gpf) or liters per flush (Lpf), in accordance with Section 7.3, Water Consumption Test, of ASME A112.19.2–2018. For dual-flush water closets, the measurement of the water flush volume shall be conducted separately for the full-flush and reduced-flush modes and in accordance with the test requirements specified Section 7.3, Water Consumption Test, of ASME A112.19.2–2018. The final measured flush volume for each tested unit is the average of the total flush volumes recorded at each test pressure as specified in Table 5 “Static test pressures for water closets, kPa (psi),” of ASME A112.19.2–2018, based on the average of the individual flush volumes at a given pressure from the three tests.
(ii) Flush volume and tank trim component adjustments: For gravity flush tank water closets, set trim components that can be adjusted to cause an increase in flush volume, including (but not limited to) the flapper valve, fill valve, and tank water level, in accordance with the printed installation instructions supplied by the manufacturer with the unit. If the printed installation instructions for the model to be tested do not specify trim setting adjustments, adjust these trim components to the maximum water use setting so that the maximum flush volume is produced without causing the water closet to malfunction or leak. Set the water level in the tank to the maximum water line designated in the printed installation instructions supplied by the manufacturer or the designated water line on the tank itself, whichever is higher. If the printed installation instructions or the water closet tank do not indicate a water level, adjust the water level to 1±0.1 inches below the top of the overflow tube or, for gravity flush tank water closets that do not contain an overflow tube, 1±0.1 inches below the top rim of the water- containing vessel for each designated pressure specified in Table 5 of ASME A112.19.2–2018.
b. Urinals—Measure water flush volume for urinals, expressed in gallons per flush (gpf) or liters per flush (Lpf), in accordance with Section 8.6, Water Consumption Test, of ASME A112.19.2–2018. The final measured flush volume for each tested unit is the average of the total flush volumes recorded at each test pressure as specified in Table 6 “Static test pressures for urinals, kPa (psi),” of ASME A112.19.2–2018, based on the average of the individual flush volumes at a given pressure from the three tests.

General Product Information

Brief Description of UUT

Product type……………………..: UP: Prison-Type Urinal
UT: Trough-Type Urinal
UV: Vacuum-Type Urinal
UW: Waterless Urinal
UM: Wall-mounted Urinal
UN: Other Type Urinal
WB: Blowout Water Closet
WD: Dual-Flush Water Closet
WE: Electromechanical Hydraulic
WF: Flushometer Valve Water
WG: Gravity Tank-Type Water
WP: Prison-Type Water Closet
WT: Flushometer Tank Water Closet
WV: Vacuum-Type Water Closet

Copy of Marking Plate

Remark : The artwork below may be only a draft.

Smart Toilet
Model: ZM2033
Input: AC110V, 60Hz, 1200W
Max. effective flush volume: 1.2 gpf
Manufacturer: JJJK
Made in China
Manufacturer date: May 25, 2023

Limit Requirements

The water consumption of water closets and urinals, other than those designed and marketed exclusively for use at prisons or mental health care facilities, shall be not greater than the values shown in Table I.

Table I
Standards for Plumbing Fixtures

Appliance| Maximum Gallons per Flush or Dual-flush effective flush volume
---|---
Sold or Offered for Sale On or After January 1, 2016
All water closets| 1.28
Trough-Type Urinals| Trough length (inches)
| 16
Wall-Mounted Urinals| 0.125
Other Urinals| 0.5

Test Result

List of Measured Values

Name of measured value UUT Represented Value Mean

Maximum water consumption of Gallons per Flush (required for water closets, Type code: WB, WE, WF, WG, WP, WT, WV) ············:| ****

| ****

1.28 gpf

Dual flush effective water consumption of Gallons per Flush (required for water closets, Type code: WD) ··································:| ****

1.18

| ****

1.28 gpf

Trough length (inches) (required for Trough- Type Urinals, Type code: UT) ·················:| -| 16 inchs
Maximum water consumption of Gallons per Flush (required for Wall-Mounted Urinals, Type code: UM) ···································:| ****

| ****

0.125 gpf

Maximum water consumption of Gallons per Flush (required for Urinals, Type code: UP, UV, UW, UN) ······································:| ****

| ****

0.5 gpf

Passes Waste Extraction Test (required for water closets, Type code: WB, WD, WE, WF, WG, WP, WT, WV) ······························:| ****

pass

| ****

Waste Extraction Value(Grams) (required for water closets, Type code: WB, WD, WE, WF, WG, WP, WT, WV) ······························:| ****

350

| ****

Appendix 1 Photo Documentation

Photo Documentation