Product Information
Specifications
- Current Alarm: Yes
- Autocycle Ground Fault Alarm: Yes
- Ethernet: Yes
- Max Power Supply Input: N/A
- Wire Size Max Heating Cable Output: N/A
- Wire Size Control Max Current: N/A
- Max Ground Terminal Wire Size: N/A
- Voltage Alarm Control Max Voltage: N/A
- Relative Humidity: N/A
- Communication Protocol: N/A
- Control Relay Type: N/A
- Communication Control Algorithms: N/A
- RS-485 Cable Type: N/A
- Temperature Control Range: N/A
- Temperature Alarm Operating Temperature: N/A
Features
- Simple to install
- Reliable during long life
- 2 year product warranty available
Product Usage Instructions
Installation
- Ensure the power supply is turned off before installation.
- Locate the existing Elexant 4010i heat tracing controller module.
- Disconnect any power supply cables connected to the module.
- Carefully remove the old module from its mounting position.
- Insert the ELEXANT 4010i-MOD replacement module into the mounting position.
- Secure the module in place using the appropriate mounting hardware.
- Reconnect the power supply cables to the new module.
- Turn on the power supply and verify proper functionality.
Warnings
It is important to follow these warnings to ensure safe usage of the
product:
- nVent products should only be installed and used as indicated in nVent’s product instruction sheets and training materials.
- Improper installation, misuse, misapplication, or failure to follow nVent’s instructions and warnings may result in product malfunction, property damage, serious bodily injury, and death.
- Make sure to read and understand the instruction sheets available at www.nvent.com or from your nVent customer service representative.
FAQ
- Q: Where can I find the instruction sheets for nVent products?
- A: Instruction sheets for nVent products can be found at www.nvent.com or obtained from your nVent customer service representative.
- Q: What should I do if I experience a product malfunction?
- A: In case of product malfunction, please contact nVent customer service representative for assistance.
- Q: What is the warranty period for the ELEXANT 4010i-MOD replacement module?
- A: The ELEXANT 4010i-MOD replacement module comes with a 2-year product warranty.
- Q: What regions does nVent provide customer support for?
- A: nVent provides customer support in North America, Europe, Middle East, Africa, Asia Pacific, and Latin America. Please refer to the contact information provided in the user manual for specific contact details.
FEATURES
Simple to install
Reliable during long life: 2 year product warranty available
nVent RAYCHEM ELEXANT 4010i-MOD is a replacement module for the Elexant 4010i heat tracing controller.
SPECIFICATIONS
Current Alarm: 0.1 – 100 A
- Autocycle: 1 – 750 h
- Ground Fault Alarm: 10 – 500 mA
- Ethernet: 10/100 Base-T
- Max Power Supply Input Wire Size: 16.8 mm²
- Max Heating Cable Output Wire Size: 16.8 mm²
- Control Max Current: 32A @ 40°C, De-Rated to 24A @ 50°C and Further De-Rated to 16A @ 60°C
- Max Ground Terminal Wire Size: 33.6 mm²
- Voltage Alarm: 80 – 300 V
- Control Max Voltage: 277 VAC Nominal, 50/60Hz
- Relative Humidity: 0% to 90%, Noncondensating
- Communication Protocol: Modbus RTU; Modbus/TCP; DHCP
- Control Relay Type: Double-Pole, Solid-State; Double-Pole, Mechanical
- Communication: RS-485; Ethernet
- Control Algorithms: On/Off, Proportional, PASC, Always On, Always Off
- RS-485 Cable Type: One 2-Wire, Shielded Twisted Pair
- Temperature Control Range: −200 to 700 °C
- Temperature Alarm: −200 to 700 °C
- Operating Temperature: −40 to 60 °C
Catalog Number | Item Name |
---|---|
10380-015 | 4010i-MOD |
10380-016 | 4010i-MOD-IS |
WARNING
nVent products shall be installed and used only as indicated in nVent’s product instruction sheets and training materials. Instruction sheets are available at www.nvent.com and from your nVent customer service representative. Improper installation, misuse, misapplication or other failure to completely follow nVent’s instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty.
Contact Information
North America
- Tel +1.800.545.6258
- Fax +1.800.527.5703
- thermal.info@nvent.com
Europe, Middle East, Africa
- Tel +32.16.213.511
- Fax +32.16.213.604
- thermal.info@nvent.com
Asia Pacific
- Tel +86.21.2412.1688
- Fax +86.21.5426.3167
- cn.thermal.info@nvent.com
Latin America
- Tel +1.713.868.4800
- Fax +1.713.868.2333
- thermal.info@nvent.com
Our powerful portfolio of brands:
CADDY ERICO HOFFMAN RAYCHEM SCHROFF TRACER
© 2022 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without notice.
References
- Building a more Sustainable and Electrified World | nVent
- Building a more Sustainable and Electrified World | nVent
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>