SINE S400 UPS Inverter Charger User Manual

June 16, 2024
SINE

SINE S400 UPS Inverter Charger

Technogamma SineUPS User Manual

Warning!

  • SineUPS works at high voltage and requires special attention when it’s being connected!
  • The device is designed for home use only! Please make sure there is enough space around it to vent properly, do not install it in a place exceeding the operating temperature and humidity!

Mounting

  • The device can be mounted on a horizontal surface or vertically on a wall. To mount it vertically, install 4 screws on the wall (3.5 x 35 mm), so the unit can be hung as depicted in the drawing below.
  • A diagram illustrates the device dimensions and mounting points, with a width of 225 mm and a height of 145 mm.

Note: Model S1200 operates using a 24V battery! You can connect two 12V batteries, in series, as they have to be equal capacity and in similar condition and type!

Note: External battery is not part of the product

FAQ

  • Can SineUPS be used without a battery?
  • No, the device does not function without a connected battery.
  • What type of batteries can be connected to the SineUPS?
  • Model S1200 operates using 24V batteries. For other models, 12V lead-acid batteries are used. Batteries need to be of equal capacity and in similar condition
  • and type when connected in series.
  • What should I do if the device does not turn on when connected to the mains?
  • Check that the battery is connected and in good condition. Also, check the device fuse and replace it if necessary.
  • What are the indicators for normal battery mode operation?
  • In normal battery mode, the device is turned on and the mains are missing, indicated by the LED being on and the device beeping every 30 seconds.

Introduction

SineUPS is an uninterruptible power supply, guaranteeing constant powering to the electric loads connected. In case of mains failure (power cut or instability), SineUPS generates a pure sine wave and can work continuously until the battery runs out. The output voltage has the same form as the mains voltage meaning that the connected loads will work just as efficiently as being powered from the mains network.
When the device is powered by regular mains voltage, it keeps the battery fully charged so it can provide its maximum capacity when needed.

Installation

Warning!

  • SineUPS works at high voltage and requires special attention when it’s being connected!
  • The device is designed for home use only! Please make sure there is enough space around it to vent properly, do not install it in a place exceeding the operating temperature and humidity!

Mounting

The device can be mounted on a horizontal surface or vertically on a wall. To mount it vertically, install 4 screws on the wall (3.5 x 35 mm), so the unit can be hung as depicted in the drawing below.

SINE-S400-UPS-Inverter-Charger-FIG-1

Connection

SINE-S400-UPS-Inverter-Charger-FIG-2

  1. Connect the load’s power plug to the OUTPUT socket of the UPS.
  2. Connect the battery to the BATTERY terminal, paying attention to the polarity – the + cable goes to the + terminal of the battery. Depending on the particular type of installed battery, there is the possibility that some harmful gases can be released and in that case, it is recommended to install the device in a proper location.
    • Model S1200 operates using a 24V battery! You can connect two 12V batteries, in series, as they have to be of equal capacity and in similar condition and type!
  3. Verify that the load and battery are properly connected. Plug the power plug of the UPS (INPUT terminal) into the main socket. If mains is present, the device will start charging the battery. If in the electrical installation, a common neutral is used instead of protective earth (PE), it is recommended to cut off the plug and power the device using hard-wiring – brown wire to phase and blue to neutral.
  4. Turn on the device to power the load connected by pressing the power on button (see next chapter Operation).

Operation

SINE-S400-UPS-Inverter-Charger-FIG-3

Symbol Function Description
**** ****

Power On/ Off button

| Press and hold the button for 0.5 sec to turn the device on or off.
|

On

| ****

The device is turned on.

| ****

Battery

| ****

4 levels of battery charge, each LED stands for 25% charge.

| ****

Mains Power

| ****

Stable mains. The LED blinks if the mains voltage is not within the limits.

| ****

Error

| An error occurred: overload, overheating, or internal error.

Press and hold the power button for 0.5 sec to power the device and load connected. The button LED lights on and a beeping sound is made.

Stable mains

  • Whenever stable mains are present, the device charges the battery and displays the current charge on the panel.
  • If the device is turned on and the mains is off or unstable, it automatically switches to battery-powered mode.
  • If the mains is not available, the indicator goes off, if the mains voltage is not within the specified limits the indicator blinks.

Battery power

Switching to battery-powered mode a continuous sound is made in the time of transition and then a short one every 30 sec. The time to operate on battery power depends on the capacity, charge and condition of the connected battery, as well as the power of the load connected. When the battery charge goes below 10%, the device beeps every 2 sec until the battery voltage goes below 10.2 V (20.4 V for the 51200 model), then the device automatically shuts down. When the mains is restored, the device automatically turns on and starts charging the battery. In case of connecting a load that is more powerful than the device-rated output power or short-circuit of the output, the LED lights up and the power to the load is cut off. The UPS will attempt 10 retries in 10 sec to restore the power to the load and if the overload condition is removed will go back to normal battery power operation.

Troubleshooting

SINE-S400-UPS-Inverter-Charger-FIG-12

Technical parameters

| Parameter| S400| S600| S850| S1200
---|---|---|---|---|---
Input| Voltage| 220 VAC
Frequency| 50 Hz
Voltage to switch to battery-powered mode| below 180 VAC

over 260 VAC

Protection| Fuse, mounted on the housing
Output| Voltage| 220VAC ± 4%
Frequency| 50 Hz± 1 Hz
Power| 400W| 600W| 850W| 1200W
Voltage form| Pure sine wave
Switching time| < 5ms


Protection

| Automatic resettable protection from overload and short circuit
Battery| Type| Lead-acid
Voltage| 12 V| 24 V


Capacity

| External* 20-150

Ah

| External* 40-250

Ah

| External* 60-350

Ah

| External* 40-250

Ah

Protection| Reverse polarity connection protection
| Weight| 6.2 kg| 6.9 kg| 7.9 kg| 8.1 kg
Dimensions| 255 x 215 x 130 mm
Ambient temperature| 0-35 °C
Relative humidity| 0-95 %

External battery is not part of the product.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals