GENERALLIFE FH254 Underfloor Heating Thermostat User Manual

June 16, 2024
GENERALLIFE

GENERALLIFE FH254 Underfloor Heating Thermostat

Product Information

The FH254 Underfloor Heating Thermostat is a digital room thermostat designed specifically for underfloor heating systems. It allows users to set the desired room temperature, providing more comfortable and affordable heating. The thermostat features sensitive temperature measurement, hysteresis adjustment, temperature calibration, ON/OFF control, wired connection, and floor sensor temperature setting.

General Specifications

  • Dimensions (H/L/W): Not specified
  • Operating Current: Not specified
  • Relay NO Switching Current: Not specified
  • Temperature Measurement Accuracy: Not specified
  • Operating Sensitivity: Not specified
  • Operating Temperature Range: Not specified
  • Storage Temperature: Not specified

Product Usage Instructions

Room Thermostat Placement

Place the Room Thermostat in a room that is frequently used in your living space, such as the hall or living room. Avoid installing it in areas with high air circulation, like near doorways or windows. Additionally, do not place it close to heating units (heater core, fireplace, etc.) or in direct sunlight. It is recommended to install the thermostat at a height of 150 cm from the floor.

Temperature Calibration

The temperature sensors used in Room Thermostats are highly sensitive. To calibrate your Room Thermostat based on the temperature in your living space:

  1. Ensure the device is off.
  2. Press and hold the button for 3 seconds.
  3. Press the button until the calibration menu appears.
  4. Adjust the sensitivity by turning the button to the right or left. Press the button until the device turns off to save the
    settings and exit.

Floor Sensor Temperature Setting

If an external floor sensor is connected, it can be used to measure the floor temperature. To set the floor sensor temperature:

  1. Ensure the device is off.
  2. Press and hold the button for 3 seconds.
  3. Press the button until the floor sensor temperature menu appears.
  4. Adjust the temperature by turning the button to the right or left.
  5. Press the button until the device turns off to save the settings and exit.

Factory Reset

If you need to reset the Room Thermostat to its factory default settings:

  1. Ensure the device is off.
  2. Press and hold the button for 3 seconds.
  3. Press the button until the menu appears.
  4. In the menu, turn the button to the right or left to select the “Factory Reset” option.
  5. Press the button to confirm the selection.
  6. The device will turn off and reset to factory settings.

FAQ

  • Q: What is the purpose of the hysteresis adjustment?
  • A: The hysteresis adjustment allows you to set a temperature range within which the thermostat will activate or deactivate the heating system. This helps prevent frequent cycling of the heating system and provides more stable temperature control.
  • Q: Can I use the Room Thermostat without connecting an external floor sensor?
  • A : Yes, the Room Thermostat can still function without the floor sensor. However, the floor sensor provides a more accurate temperature measurement for underfloor heating systems.

GENERAL SPECIFICATIONS

FH254 is a digital room thermostat designed for the underfloor heating system. A user provides more comfortable and affordable heating by setting needed room temperature.

  • Sensitive Temperature Measurement
  • Hysteresis Adjustment
  • Temperature Calibration
  • ON/OFF Control
  • Wired connection
  • Floor sensor temperature setting

FH254 AND EQUIPMENTGENERALLIFE-FH254-Underfloor-Heating-Thermostat-
FIG-1

TECHNICAL DATA

Dimensions ( H / L / W ) 85.7mm / 85.7mm / 33.5mm
Operating Current 230V AC
Relay NO Switching Current 7A (240VAC – Resistive load)

10A (120VAC – Resistive load)

Temperature Measurement

Accuracy

| 0.1oC
Operating Sensitivity| (-2.0oC) – (+2.0oC)
Operating Temperature Range| (5oC) – (30oC)
Operating Temperature| (-10oC) – (+50oC)
Storage Temperature| (-20oC) – (+60oC)

ROOM THERMOSTATGENERALLIFE-FH254-Underfloor-Heating-Thermostat-
FIG-2

GENERALLIFE-FH254-Underfloor-Heating-Thermostat-FIG-3

  • The external floor sensor is only active when it is connected.

ROOM THERMOSTAT PLACEMENT

Place your Room Thermostat in a room you use frequently in your living space. For example; the hall or living room of your home. Avoid installing the Room Thermostat in places where there is a lot of air circulation, such as at the doorway or by the window. Also, do not place it close to heating units (heater core, fireplace, etc.) and in direct sunlight. We recommend that the room thermostat be placed at a height of 150 cm from the floor.

GENERALLIFE-FH254-Underfloor-Heating-Thermostat-FIG-4

ROOM THERMOSTAT TEMPERATURE CALIBRATION

Temperature sensors used in Room Thermostats are very sensitive. Based on the temperature on the thermometers in your living space you need to calibrate your Room Thermostat. For this:

  • While your device is off, press and hold the button for 3 seconds.
  • Press the button until you see the calibration menu that says “ ” press it. The temperature difference you want from the calibration menu, Adjust by turning the button to the right or left. This value can be adjusted between “-8°C” and “+8°C”.
  • Press the button until the device turns off to save the settings and exit.
  • Note: The recommended temperature calibration setting is “0.0 C”.

ROOM THERMOSTAT HYSTERESIS POSITIVE MENU

The hysteresis-positive factory setting of your Room Thermostat is  0.5°C. This value can be adjusted between “0.1°C” and “2.0°C”. While the hysteresis positive value is 0.5°C, your Room Thermostat will send a command to your heating unit when the room temperature rises 0.5°C above the set temperature. For example, when we set the Room Thermostat to 22.0°C, your heating unit will stop when the room temperature rises to 22.5°C. To change the hysteresis positive setting:

  • While your device is off, press and hold the button for 3 seconds.
  • “Press the button until the “ ” menu appears.
  • In the hysteresis positive menu, you can adjust the operating sensitivity by turning the “ ” button to the right or left.
  • Press the button until the device turns off to save the settings and exit.
  •  The settings you have made have been saved. When you turn on your device, it will work with the operating sensitivity you have set

ROOM THERMOSTAT HYSTERESIS NEGATIVE MENU

The hysteresis-negative factory setting of your Room Thermostat is -0.5°C. This value can be adjusted between “-0.1°C” and “-2.0°C”. While the hysteresis negative value is -0.5°C, your Room Thermostat will send a command to your heating unit when the room temperature drops 0.5°C below the set temperature. For example, when we set the Room Thermostat to 22.0°C, your heating unit will work when the room temperature drops to 21.5°C. To change the hysteresis negative setting:

  • While your device is off, press and hold the button for 3 seconds.

  • Press the button until the “ ” menu appears.

  • In the hysteresis negative menu, you can adjust the operating
    sensitivity by turning the “ ” button to the right or left.

  • Press the button until the device turns off to save the settings and exit.

  • The settings you have made have been saved. When you turn on your device, it will work with the operating sensitivity you have set.

FLOOR SENSOR TEMPERATURE SETTING MENU

If a floor sensor is installed with a Room Thermostat, only a GENERAL Life floor sensor should be installed. Otherwise, the product will be out of warranty.
In case the floor sensor connected, the following settings apply. The factory temperature setting for floor sensor is 28°C. This value can be adjusted between 23°C and 34°C. The floor sensor operating sensitivity is 1°C. For example, when you set the floor sensor temperature to 28°C, your Room Thermostat will stop the heating unit from working when the floor temperature rises to 29°C. When the floor temperature drops to 27°C, it starts the heating unit of the Room Thermostat. To change the floor sensor temperature:

  • Press and hold the button for 3 seconds while your device is off.
  • Press the button until the “ ” menu appears.
  • Adjust the operating temperature by turning the “ ” button to the right or left in the floor sensor temperature menu that appears.
  • Press the button until the device turns off to save the settings and exit.
  • The settings you have made have been saved. When you turn on your device, it will operate at the floor sensor temperature you have set.

FACTORY RESET

You can reset the Room Thermostat to its factory default settings. This action resets the calibration setting and hysteresis settings to the factory setting. To factory reset your Room Thermostat:

  • While your device is off, press and hold the button for 3 seconds.
  • Press the button until the “ ” menu appears.
  • While in the “ ” menu, turn the button to the right or left, select the “ ” option, and press the button.
  • Your device will turn off and reset to the factory setting

ROOM THERMOSTAT WORKING PRINCIPLE

As soon as you energize your Room Thermostat, it will start working. It is based on the average temperature of the environment where the Room Thermostat is located in the last 40 seconds. If the ambienttemperature rises above the hysteresis positive temperature you set, your Room Thermostat turns off the heating unit, and if it drops below the hysteresis negative temperature value, it turns on the heating unit. Thus, it is ensured that the ambient temperature remains within a certain range. If the floor sensor measures temperature above 28°C, it turns off the heating unit.

  • The external floor sensor is only active when it is connected

GENERALLIFE-FH254-Underfloor-Heating-Thermostat-FIG-11

ROOM THERMOSTAT WIRING DIAGRAM

GENERALLIFE-FH254-Underfloor-Heating-Thermostat-FIG-12

WIRING DIAGRAM FOR ACTUATORS

WIRING DIAGRAM FOR WIRING CENTER

WARNING

Operating related to the control panel, heating unit, or electrical installation must be carried out by persons with professional qualifications.

DECLARATION OF CONFORMITY

The Head Office and production site is located on Fatih Mah. 1188 Sk.No:13/A Sarnıç – Gaziemir – İZMİR – TÜRKİYE confirms and declares that the product marked with CE and its specifications below is covered by the provisions of the mentioned directive.

  • Brand: GENERAL Life
  • Product Name : FH254
  • Product Type : Floor Heating Room Thermostat
  • Compatible Directives:

Electromagnetic Compatibility Regulation 2014/30/EU (EMC EN 61000-6-3: 2007 + A1: 2011, EN 61000-6-1: 2007) Low Voltage Directive 2014/35/EU (LVD EN 60730-2-9:2010, EN 60730-1:2011) Additional Information: The mentioned product can be used with boilers with on / off output and compliance with the directives only covers the product. ISIPARK is not responsible for the entire system’s compliance with the directives. This statement is not valid if changes are made to the product without our approval.

WARRANTY CONDITIONS

  1. The warranty period starts from the invoice date and is warranted against manufacturing defects for 2 years.
  2. Devices and apparatus are delivered to the customer in working condition in our company. On-site commissioning is subject to a service fee.
  3. The repair of the devices and apparatus covered by the warranty is carried out in our company factory and should be sent by a contracted transportation company. In on-site services, the transportation and accommodation expenses of the service personnel belong to the customer. The shift fee during transportation is added to the service fee and collected in advance.
  4. The maintenance of devices and apparatus is done in our company. For the maintenance of the devices and apparatus, the round travel fares belong to the customer.
  5. In case of malfunctioning of the devices and apparatus whose warranty period continues, it is tested in our company whether the malfunction is caused by a customer or manufacturer fault, and it is reported with a report issued by our company.
  6. In case of detection of manufacturer-induced errors of devices and apparatus whose warranty period continues, the customer can request a replacement or repair of the devices and apparatus at full expense by the manufacturer, unless it’s higher than the product’s price.
  7. In the event that the faults of the devices and apparatus whose warranty period continues are determined as caused by the customer, all expenses would belong to the customer.
  8. Customers should be aware of damages (if there is any) to the product and warn the manufacturer from the day the warranty duration starts.If the customer do not warn the manufacturer with knowledge of the damage, the customer loses the rights of article 6.
  9. Malfunctions resulting from the use of devices and apparatus contrary to the matters stated in the User Manual are not covered by the warranty.
  10. Devices and their apparatus are out of warranty if they are beaten, broken, or scratched by the customer.
  11. Damages resulting from the use of devices and apparatus belonging to other brands and models without the approval of the manufacturer are not covered by the warranty.
  12. Battery leakage and errors due to rust, oxidation, and liquid contact by working in acidic/humid environments are not covered by the warranty.
  13. When the product is not used for a long period (more than 15 days), remove the batteries. Otherwise, malfunctions that will occur are out of warranty.
  14. Damages that may occur during the transportation of devices and apparatus are not covered by the warranty. Customers can take transportation insurance.
  15. Damages caused by mains voltage / faulty electrical installation are not covered by the warranty.
  16. Devices and apparatuses are out of warranty for malfunctions caused by force majeure such as fire, flood, earthquake, etc.
  17. All of the devices and apparatuses, including all their parts, are under the warranty of our company.
  18. In case of malfunction of the devices and apparatuses within the warranty period, the time spent during the repair period is added to the warranty period. The repair period of the product cannot exceed 20 working days. This period starts from the date of notification to the service station of the malfunction related to the product or, in the absence of a service station, to the seller, dealer, agency, representative, importer, or manufacturer of the product. Consumers can report the problem by; phone, fax, e-mail, registering and replying to a paid letter, or a similar way. However, in case of a conflict, the responsibility of proving belongs to the customer. If the malfunction of the product is not repaired within 20 working days, the manufacturer-producer or importer; has to allocate another product with similar features to the use of the consumer until the repair of the product is completed.
  19. Although the consumer uses his/her repair rights,
  20. f the product breaks down 4 times in a year or 6 times in warranty duration these problems affect the main purpose of the product. (starting from delivery time during warranty.)
  21.  Exceeding the maximum time required for repair,
  22. If the service station is not available, if it is determined that the repair of the defect is not possible with the report prepared (in order) by one of the sellers, dealers, agencies, representatives, importers, or manufacturers, a refund or a price discount at the rate of defect can be requested.
  23. The customer can make complaints and appeals to consumer courts or consumer arbitration committees.
  24. The warranty document must be kept by the customer during the warranty period. If the document is lost, a second document will not be issued. In case of loss, repair, and replacement of devices and apparatus will be made for a fee

WARRANTY CERTIFICATE

Manufacturer

  • Address : Fatih Mah. 1188 Sk. No:13/A Sarnıç Gaziemir İzmir-TÜRKİYE
  • Tel: +90 (232) 457 99 50
  • Fax : +90 (232) 457 91 22
  • E-mail: generallife@generallife.com.tr
  • Authorized Signature:
  • Company Stamp:

Product

  • Type : Floor Heating Room Thermostat
  • Brand: GENERAL Life
  • Model : FH254
  • Warranty Period: 2 Years
  • Max. Time to Repair: 20 Days
  • Bandrol and Serial Number :

GENERALLIFE-FH254-Underfloor-Heating-Thermostat-FIG-16

ISIPARK reserves the right to change product specifications and user manuals.