DAB 112-20 M Garden Pump Instruction Manual
- June 16, 2024
- Dab
Table of Contents
- APPLICATIONS
- PUMPED FLUIDS
- TECHNICAL DATA AND RANGE OF USE
- MANAGEMENT
- INSTALLATION
- ELECTRICAL CONNECTION
- STARTING UP
- PRECAUTIONS
- MAINTENANCE AND CLEANING
- MODIFICATIONS AND SPARE PARTS
- TROUBLESHOOTING
- Specification
- Customer Support
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DAB 112-20 M Garden Pump
APPLICATIONS
Self priming centrifugal pump (until 9m) with excellent suction capacity even in the presence of air bubbles. Suitable for pumping water with low levels of sandy impurities. Especially used in domestic water supply installations. Suitable for small farms and gardening, small scale industrial services and where self priming is necessary.
PUMPED FLUIDS
The machine has been designed and built for pumping water, free from explosive substances and solid particles or fibres, with a density of 1000 kg/m³ and a kinematic viscosity of 1 mm²/s, and chemically non-aggressive liquids.
TECHNICAL DATA AND RANGE OF USE
Supply voltage:| 220 – 240V 50Hz / 110V 50Hz 115V 60Hz / 230V 60Hz / 230 V3 –
400 V3 50/60Hz 115-127 V 60 Hz / 220-230V 60Hz / 220-277/380-480V 60Hz| see
electrical data plate
---|---|---
Absorbed power:| see electrical data plate
Delivery| max 4,8 m3/h
Head up – Hmax (m):| pag. 77
Pumped liquid:| clean, free from solid bodies or abrasive substances, non-
aggressive.
Degree of motor protection:| IP44 (For IP55 see plate on package)
Degree of terminal board protection:| IP55
Protection class:| F
Storage temperature:| -10°C to 40°C| Relative humidity of the air: MAX. 95%
Liquid temperature range:| 0+40°C| Maximum operating pressure:| Jet-Jetinox
max 0.8 mPa (8bar) Jetcom max 0.6 mPa (6 bar)
Noise level:|
- For pumps intended for outdoor use: noise emission according to Directive 2000/14/CE.
- For other pumps: noise emission according to Directive EC 89/392/CEE and subsequent amendments.
Motor construction| in conformity with standards CEI 2-3 – CEI 61-69 (EN 60335-2-41)
The leads of the supply cables must have a rated section no smaller than that illustrated in the following table:
Rated current of the appliance A| Rated section mm²|
---|---|---
| | ≤ 0,2| Flat twin tinsel cord a| a These cables may be used only if their
length does not exceed 2 m between the point in which the cable or its sheath
enters the appliance and its entry in the plug.
0,2| and| ≤ 3| 0,5 a
3| and| ≤ 6| 0,75
6| and| ≤ 10| 1,0 (0,75) b
10| and| ≤ 16| 1,5 (1,0) b
16| and| ≤ 25| 2,5| The cables with the sections indicated in brackets may be used for mobile appliances if their length does not exceed 2 m.
25| and| ≤ 32| 4
32| and| ≤ 40| 6
40| and| ≤ 63| 10
MANAGEMENT
Storage
All the pumps must be stored indoors, in a dry, vibration-free and dust-free
environment, possibly with constant air humidity.
They are supplied in their original packaging and must remain there until the
time of installation. If this is not possible, the intake and delivery
aperture must be accurately closed.
Transport
Avoid subjecting the products to needless jolts or collisions.
To lift and transport the unit, use lifting equipment and the pallet supplied
standard (if applicable).
Weights
The adhesive label on the package indicates the total weight of the electropump.
Checking motor shaft rotation
Before installing the pump you must check that the rotating parts turn freely.
For this purpose remove the fan cover from its seat in the motor end cover.
Insert a screwdriver in the notch on the motor shaft from the ventilation
side. If there is a blockage, turn the screwdriver, tapping it gently with a
hammer. FIG. A
INSTALLATION
The pumps may contain small quantities of residual water from testing. We advise flushing them briefly with clean water before their final installation.
-
The electropump must be fitted in a well ventilated place, protected from unfavourable weather conditions and with an environment temperature not exceeding 40°C. Fig.B
-
A firm anchoring of the pump to the bearing surface favours the absorption of any vibrations caused by pump operation. Fig. C
-
Ensure that the metal pipes do not exert undue strain on the apertures, thus preventing deformations or breakages. Fig. C
-
The lifting and carrying handle must always be present and well fixed to the support on all pumps produced in the portable version.
-
Pumps that are to be used in fountains for outdoor use, in garden ponds and similar places, must be fed by means of a circuit equipped with a differential current device, the rated operating differential current of which is not higher than 30 mA.
ELECTRICAL CONNECTION
Caution! always follow the safety regulations.
Scrupulously follow the wiring diagrams inside the terminal board box.
- In fixed installations, International Safety Standards require the use of isolating switches with a fuse-carrier base.
- Single-phase motors are provided with built-in thermal overload protection and may be connected directly to the mains. Three-phase motors must be protected with an automatic switch (e.g. overload protection) set at the values on the electropump data plate.
- In the power mains there must be a device that ensures complete disconnection in overvoltage category III conditions.
STARTING UP
-
Do not start the pump unless it has been completely filled with fluid.
Before starting up, check that the pump is properly primed; fill it completely with clean water by means of the hole provided after having removed the filler cap on the pump body (Fig. F). Dry operation causes irreparable damage to the mechanical seal. The filling cap must then be screwed back on carefully.
-
Switch on the power and check, on the three-phase version, that the motor is turning in the correct direction; this should be in a clockwise direction, looking at the motor from the impeller side. Fig. G If it is turning in the wrong direction, invert the connections of any two wires on the terminal board, after having disconnected the pump from the power mains.
PRECAUTIONS
- The electropump should not be started more than 20 times in one hour so as not to subject the motor to excessive thermal shock.
- When starting after long periods of inactivity, the starting-up operations listed above must be repeated.
- It is always good practice to place the pump as close as possible to the liquid to be pumped (Fig.I – Pag.74)
MAINTENANCE AND CLEANING
The electropump must not be dismantled unless by skilled personnel in possession of the qualifications required by the regulations in force. In any case, all repairs and maintenance jobs must be carried out only after having disconnected the pump from the power mains.
MODIFICATIONS AND SPARE PARTS
Any modification not authorized beforehand relieves the manufacturer of all
responsibility.
In the event of damage to the power cable of this appliance, the repair must
be carried out by skilled personnel, in order to prevent all risks.
Removal and replacement of the supply cable
Before starting, ensure that the electropump is not connected to the power
network.
For versions without a pressure switch:Remove the condenser cover, unscrewing
the four screws on it. Unscrew the three terminals L – N – and disconnect the
brown lead, the blue lead and the yellow-green lead, coming from the supply
cable, after having slackened the grommet.
- Section of cable with plug from the pressure switch: unscrew the screw from the cover of the pressure switch using a screwdriver and remove the cover, releasing it from the base of the pressure switch. Slip out the yellow-green lead, unscrewing the earth screw on the left side. Still on the same side, slip the blue lead and the brown lead off their terminals, slackening the screws on the terminals. Slacken the cable clamping nut of the pressure switch on the left side and slip off the cable which is now disconnected.
- Section of cable from the pressure switch to the terminal board: unscrew the nut on the cover of the pressure switch using a screwdriver and remove the cover, releasing it from the base of the pressure switch. Slip out the yellow-green lead, unscrewing the earth screw on the right side. Still on the same side, slip the blue lead and the brown lead off their terminals, slackening the screws on the terminals. Slacken
the cable clamping nut of the pressure switch on the right side and slip off the cable which is now disconnected. Remove the terminal board cover, unscrewing the four screws on it. Unscrew the three terminals L – N – and disconnect the brown lead, the blue lead and the yellow green lead, coming from the supply pressure switch, after having slackened the grommet.
When replacing the power cable, a cable of the same type must be used (e.g. H05 RN-F or H07 RN-F depending on the installation) and with the same terminals, proceeding as for disassembly in inverse order.
ATTENTION: depending on the installation and if the pumps have no cable, fit supply cables type H05 RN-F for indoor use and type H07 RN-F for outdoor use, complete with plug (EN 60335-2-41). For power cables without a plug, provide a device for cutting off the mains (e.g. magnetothermal device) with separating contacts of at least 3 mm for each pole.
TROUBLESHOOTING
FAUL | CHECKS (possible cause) | REMEDY |
---|---|---|
The motor does not start and makes no noise. |
- A. Check the electric connections.
- B. Check that the motor is live.
- C. Check the protection fuses.
| C. If they are burnt-out, change them.
N.B. If the fault is repeated immediately this means that the motor is short circuiting.
The motor does not start but makes noise.|
- A. Ensure that the mains voltage is the same as the value on the plate.
- B. Ensure that the connections have been made correctly.
- C. Check that all the phases are present on the terminal board. (3~)
- D. Look for possible blockages in the pump or motor.
- E. Check the condition of the capacitor
|
- B. Correct any errors.
- C. If not, restore the missing phase.
- D. Remove the blockage.
- E. Replace the capacitor
The motor turns with difficulty.|
- A. Check the voltage which may be insufficient.
- B. Check whether any moving parts are scraping against fixed parts.
|
- B. Eliminate the cause of the scraping.
The pump does not deliver.|
-
A. The pump has not been primed correctly.
-
B. On three-phase motors, check that the
direction of rotation is correct. -
C. The diameter of the intake pipe is insufficient.
-
D. Blocked foot valve.
|
- B. If necessary, invert the connection of two supply wires
- C. Replace the pipe with one with a larger diameter.
- D. Clean the foot valve.
The pump does not prime.|
- A. The intake pipe or the foot valve is taking in air.
- B. The downward slope of the intake pipe favours
the formation of air pockets.
|
- A. Eliminate the phenomenon and prime again.
- B. Correct the inclination of the intake pipe.
The pump supplies insufficient flow.|
- A Blocked foot valve.
- B. The impeller is worn or blocked.
- C. The diameter of the intake pipe is insufficient.
- D. On three-phase motors, check that the
direction of rotation is correct.
|
- A. Clean the foot valve.
- B. Remove the obstructions or replace the worn parts.
- C. Replace the pipe with one with a larger diameter.
- D. If necessary, invert the connection of two supply wires.
The pump vibrates and operates noisily.|
-
A Check that the pump and the pipes are firmly anchored.
-
B. There is cavitation in the pump, that is the
demand for water is higher than it is able to pump. -
C. The pump is running above its plate characteristics.
|
- A. Fix the loose parts more carefully.
- B. Reduce the intake height or check for load losses.
- C. It may be useful to limit the flow at delivery.
Specification
Model Modell | Head up |
---|---|
Hmax (m.) 2 poles 50 Hz | Hmax (m.) 2 poles 60 Hz |
JET 62 / JETINOX 62 / JETCOM 62 / AQUAJET COM 62 / GARDEN-COM 62 | 42.1 |
JET 82 / JETINOX 62 / JETCOM 82 / AQUAJET 82 / AQUA JETINOX 82 / AQUA JETCOM
82 / GARDEN-JET 82 / GARDEN-INOX 82 / GARDEN-COM 82| 46.8| 46.1
JET 92 / JETINOX 92 / JETCOM 92 / AQUAJET 92 / AQUAJET INOX 92 / AQUAJETCOM 92
/ GARDEN-JET 92 / GARDEN-INOX 92| 36.6| 36.2
JET 102 / JETINOX 102 / JETCOM 102 / AQUAJET 102 / AQUAJETINOX 102 / AQUAJET
COM 102 / GARDEN-JET 102 / GARDEN-INOX 102 / GARDEN-COM 102| 53.5| 53
JET 112 / JETINOX 112 / AQUAJET 112 / AQUA JETINOX 112| 61.4| 62
JET 132 / JETINOX 132 / JETCOM 132 / AQUAJET 132 / AQUA JETINOX 132 / GARDEN-
JET 132 / GARDEN-INOX 132| 47.9| 49.1
Customer Support
DAB PUMPS SOUTH AFRICA
Twenty One industrial Estate,
16 Purlin Street, Unit B, Warehouse 4
Olifantsfontein – 1666 – South Africa
info.sa@dwtgroup.com
Tel. +27 12 361 3997
DAB PUMPS S.p.A.
Via M. Polo, 14 – 35035 Mestrino (PD) – Italy
Tel. +39 049 5125000 – Fax +39 049 5125950
www.dabpumps.com