tp-link TL-SG3428X-UPS JetStream L2 L2+ Managed Switch Instruction Manual

June 16, 2024
tp-link

tp-link TL-SG3428X-UPS JetStream L2 L2+ Managed Switch

Product Information

Specifications

  • Product Name: JetStream L2/L2+ Managed Switch
  • Model: TL-SX3206HPP, TL-SX3008F, TL-SX3016F, TL-SG3210X-M2, TL-SG3210XHP-M2, TL-SG3218XP-M2, TL-SG3210, TL-SG3452, TL-SG3452X,
    TL-SG3428, TL-SG3428X, TL-SG3428X-UPS, TL-SG3428XF, TL-SG3428X-M2, TL- SG3428XPP-M2, TL-SG3428MP, TL-SG3428XMP, TL-SG3452P, TL-SG3452XP

Product Usage Instructions

Chapter 3: Connection
This chapter illustrates how to physically connect the switch.

Chapter 4: Configuration
This chapter illustrates how to configure the switch.

Appearance

The JetStream L2/L2+ Managed Switch has different LED indicators:

LED Indication
PWR On or Off: The switch is not functioning properly.
SYS On or Off: The switch is not functioning properly.
PoE On or Off: The switch is not functioning properly.
PoE Max Vert: All fans are functioning correctly. Jaune: All fans are

not functioning correctly.
FAN Speed| Vert: All fans are functioning correctly. Jaune: All fans are
not functioning correctly.
SFP+| Indication varies depending on the specific model. Refer to the
user manual for detailed information.
Link/Act 1000Mbps| Indication varies depending on the specific model. Refer to the
user manual for detailed information.
UPS| Indication varies depending on the specific model. Refer to the
user manual for detailed information.

FAQ

Q: How do I physically connect the switch?
A: Please refer to Chapter 3 of the user manual for detailed instructions on how to physically connect the switch.

Q: How do I configure the switch?
A: Please refer to Chapter 4 of the user manual for detailed instructions on how to configure the switch.

Specifications for Switches with RJ45 Ports and SFP/SFP+ Slots

IEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3ad, IEEE 802.3z, IEEE 802.3x, IEEE 802.1p, IEEE 802.1q, IEEE 802.1x, IEEE 802.1d, IEEE 802.1s, IEEE 802.1w, IEEE 802.1ab
IEEE 802.3af/at (For TL-SX3206HPP, TL-SG3210XHP-M2, TL- SG3218XP-M2, TL- SG3428MP, TL-SG3428XMP, TL-SG3452P, TL-SG3452XP, TL-SG3428XPP-M2)
IEEE 802.3bt (For TL-SX3206HPP, TL-SG3428XPP-M2)

Standards

IEEE 802.3i
(Except TL-SG3210XHP-M2, TL-SX3206HPP) IEEE 802.3ae ( Fo r T L- SX320 6 H PP, T L- SG 3210X- M2, T L- SG 3210X H P – M2, T LSG3218XP-M2, TL-SG3428X, TL- SG3428X-UPS, TL-SG3428XF, TLSG3428XMP, TL-SG3428X-M2, TL-SG3428XPP-M2, TL- SG3452X, TLSG3452XP) IEEE 802.3bz ( Fo r T L- SX320 6 H PP, T L- SG 3210X- M2, T L- SG 3210X H P – M2, T LSG3218XP-M2, TL-SG3428X-M2, TL-SG3428XPP-M2)
IEEE 802.3an (For TL-SX3206HPP)

10BASE-T: 2-pair UTP/STP of Cat. 3,4,5 (maximum 100 m) (Except TL-SX3206HPP, TL-SG3210XHP- M2, TL-SG3428XF) 100BASE-TX: 2-pair UTP/STP of Cat. 5 or above (maximum 100 m) 1000BASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) 2.5GBASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) (For TLSX3206HPP, TL-SG3210X-M2, TL-SG3210XHP-M2, TL-SG3218XPM2, TL-SG3428X-M2, TL- SG3428XPP-M2) 5GBASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) (For TL-SX3206HPP)
10GBASE-T: 4- pair UTP of Cat 6 (maximum 55 m) or STP of Cat 6, 6a, 7 (maximum 100 m) (For TL-SX3206HPP) Transmission Medium 100BASE-FX/LX10/BX10: MMF, SMF (For TL-SG3210, TL-SG3428XF, TL-SG3452, TLSG3452P) 1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF
(For TL-SX3206HPP, TL-SG3210X-M2, TL-SG3210XHP-M2, TLSG3218XP-M2, TL-SG3428X, TL-SG3428X-UPS, TL-SG3428XF, TLSG3428X-M2, TL-SG3428XPP-M2, TL-SG3428XMP, TL- SG3452X, TLSG3452XP) 10GSFP+CU SFP+ Direct Attach Cable (TL-SM5220-1M, TL- SM5220-3M)
(For TL-SX3206HPP, TL-SG3210X-M2, TL-SG3218XP-M2, TL-SG3428X,
TL-SG3428X-UPS, TL-SG3428XF, TL-SG3428XMP, TL-SG3428X-M2, TL-
SG3428XPP-M2TL-SG3452X, TL-SG3452XP)

TL-SX3206HPP: PWR, SYS, PoE Max, FAN, Speed, PoE, SFP+

TL-SG3210: PWR, SYS, 10/100/1000Mbps, SFP

TL-SG3210X-M2: PWR, SYS, Link/Act, SFP+

TL-SG3210XHP-M2: PWR, SYS, PoE Max, FAN, Speed, PoE, Port 9, Port 10

TL-SG3218XP-M2: PWR, SYS, PoE Max, FAN, Speed or PoE, SFP+, Speed, PoE

TL-SG3428MP: PWR, SYS, PoE Max, FAN, Speed or PoE, SFP, Speed, PoE

TL-SG3428/TL-SG3428X: PWR, SYS, Link/Act, 1000Mbps, Port 25­28

TL-SG3428X-UPS: PWR, SYS, UPS, Link/Act, 1000Mbps, Port 25­28

LED

TL-SG3428XF: PWR, SYS, 100/1000Mbps, FAN, SFP+

TL-SG3428XMP: PWR, SYS, PoE Max, FAN, Speed or PoE, SFP+, Speed, PoE

TL-SG3428X-M2: PWR, SYS, FAN, Link/Act, SFP+

TL-SG3428XPP-M2: PWR, SYS, PoE Max, FAN, Speed or PoE, SFP+, Speed, PoE

TL-SG3452: PWR, SYS, 10/100/1000Mbps, Port 49-52

TL-SG3452X: PWR, SYS, 10/100/1000Mbps, SFP+

TL-SG3452P: PWR, SYS, Speed, PoE Max, FAN, PoE, Port 1-52

TL-SG3452XP: PWR, SYS, Speed, PoE Max, FAN, PoE, SFP+

Operating Temperature

Storage Temperature Operating Humidity Storage Humidity

TL-SG3428XF, TL-SG3428X-M2, TL-SG3428XPP-M2, TL-SG3452, TLSG3452P, TL-SG3452X, TL-SG3452XP: 0 °C to 40 °C (32 °F to 104 °F) TL-SG3210, TL-SG3428, TL- SG3428MP, TL-SG3428X, TL-SG3428X-UPS, TLSG3428XMP: 0 °C to 45 °C (32 °F to 113 °F) TL-SX3206HPP, TL-SG3210X-M2, TL-SG3210XHP-M2, TL-SG3218XP-M2: 0 °C to 50 °C (32 °F to 122 °F)
-40 °C to 70 °C (-40 °F to 158 °F)
10% to 90% RH Non-condensing
5% to 90% RH Non-condensing

Specifications for Switches with Full SFP+ Slots (TL-SX3008F/TL-SX3016F)

Item

Content

Standards
Transmission Medium
LED Operating Temperature Storage Temperature Operating Humidity Storage Humidity

IEEE 802.3, IEEE 802.3z, IEEE 802.3ae, IEEE 802.3x 1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF TL-SX3008F: PWR, SYS, Port 1­8 TL-SX3016F: PWR1, PWR2, SYS, FAN, Port 1­16 0 °C to 45 °C (32 °F to 113 °F) -40 °C to 70 °C (-40 °F to 158 °F) 10% to 90% RH Non-condensing 5% to 90% RH Non-condensing

CE Mark Warning

This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
EU Declaration of Conformity
TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant provisions of directives 2014/30/EU, 2014/35/EU, 2011/65/EU and (EU)2015/863. The original EU Declaration of Conformity may be found at https://www.tp-link.com/en/support/ce/
UK Declaration of Conformity
TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant provisions of the Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016. The original UK Declaration of Conformity may be found at https://www .tp-link.com/support/ukca/

CAUTION:
Double pole, neutral fusing. Disconnect mainsbefore servicing. *This caution applies to the following models: TL-SG3428XPP-M2, TL-SG3452XP.
Safety Information
· Keep the device away from water, fire, humidity or hot environments. · Do not attempt to disassemble, repair, or modify the device.If you need service, please contact us. · Place the device with its bottom surface downward. · The plug on the power supply cord is used as the disconnect device, the socket- outlet shall be easily
accessible.
44

· Plug the product into the wall outlets with earthing connection through the power supply cord or plug. This equipment is not suitable for use in locations where children are likely to be present.
Please read and follow the above safety information when operating the device. We cannot guarantee that no accidents or damage will occur due to improper use of the device. Please use this product with care and operate at your own risk.
To ask questions, find answers, and communicate with TP-Link users or engineers, please visit https://community.tp-link.com to join TP-Link Community. For technical support, the user guide and other information, please visit https://www.tp-link.com/support, or simply scan the QR code. 2023 TP- Link 7106510338 REV3.7.0
45

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals