nVent 60714-079 RackChiller In Row Cooler Owner’s Manual

June 16, 2024
nVent

nVent 60714-079 RackChiller In Row Cooler

Product Information

Specifications:

  • Product Type: Air/Liquid Heat Exchanger
  • Product Family: RackChiller
  • Width: 300 mm
  • Depth: 1200 mm
  • Height: 2000 mm
  • Supply Voltage: 230 V
  • Redundant Power Supply: Yes
  • Coolant Feed: Top; Bottom

Features:

  • In-Row air/liquid heat exchanger integrated into an enclosure (RAL 9005)
  • Coolant feed from top or bottom
  • Monitoring via Ethernet interface (Web browser, Modbus TCP, SNMP v2c)
  • Temperature control based on internal or external temperature sensors
  • Highly efficient, hot-swappable EC fans with speed control
  • Redundant power feed with integrated automatic transfer switch (ATS)

Product Usage Instructions

Installation:

  1. Ensure you have read and understood the product instruction sheets and training materials provided by nVent.
  2. Select a suitable location for the RackChiller In-Row Cooler.
  3. Ensure proper power supply is available with a voltage of 230 V.
  4. Connect the coolant feed to either the top or bottom of the unit, based on your specific requirements.
  5. Make sure the RackChiller is properly grounded and connected to a reliable power source.
  6. Follow the recommended safety guidelines and local regulations during installation.

Operation:

  1. Power on the RackChiller In-Row Cooler using the provided power switch.
  2. Monitor the unit’s performance and temperature via the Ethernet interface.
  3. Adjust the temperature control settings based on your desired cooling requirements and the internal or external temperature sensors.
  4. Regularly check and clean the EC fans for optimal performance.
  5. In case of a power outage, the redundant power feed with integrated automatic transfer switch (ATS) will ensure uninterrupted cooling.

Maintenance:

  1. Refer to the product instruction sheets for recommended maintenance procedures.
  2. Inspect the unit regularly for any signs of damage or wear.
  3. Clean the heat exchanger and coolant feed system as per the manufacturer’s guidelines.
  4. Ensure proper ventilation around the RackChiller for efficient heat dissipation.
  5. Perform any necessary repairs or replacements using genuine nVent parts.

Troubleshooting:
If you encounter any issues with the RackChiller In-Row Cooler, refer to the troubleshooting section in the product instruction sheets. If the problem persists, contact nVent customer service for further assistance.

FAQ

  • Q: Can I install the RackChiller In-Row Cooler myself?
  • A: While it is possible to install the cooler yourself, we highly recommend consulting the product instruction sheets and training materials provided by nVent for proper installation and  safety guidelines.
  • Q: Can I connect multiple RackChiller units together?
  • A: Yes, RackChiller In-Row Coolers are modular and scalable, allowing you to connect multiple units together to meet your cooling requirements.
  • Q: How do I adjust the fan speed on the RackChiller?
  • A: The EC fans on the RackChiller have built-in speed control. You can adjust the fan speed through the Ethernet interface using compatible protocols such as Modbus TCP or SNMP v2c.

**CATALOG NUMBER

**

60714-079nVent-60714-079-Rack-Chiller-In-Row-Cooler-
fig-2

RackChiller In-Row Coolers (IRC) are designed to deliver localized/supplemental energy-efficient cooling in data centers. RackChiller IRC is a modular and scalable precision cooling solution that can replace or supplement traditional data center cooling infrastructure.

CERTIFICATIONS

FEATURES

  • In-Row air/liquid heat exchanger integrated into an enclosure (RAL 9005)
  • Coolant feed from top or bottom
  • Monitoring via Ethernet interface (Web browser, Modbus TCP, SNMP v2c)
  • Temperature control based on internal or external temperature sensors
  • Highly efficient, hot-swappable EC fans with speed control
  • Redundant power feed with integrated automatic transfer switch (ATS)

PRODUCT ATTRIBUTES

  • Product Type: Air/Liquid Heat Exchanger
  • Product Family : RackChiller
  • Width : 300 mm
  • Depth : 1200 mm
  • Height : 2000 mm
  • Supply Voltage : 230 V
  • Redundant Power Supply : Yes
  • Coolant Feed : Top; Bottom

ADDITIONAL PRODUCT DETAILS
For trouble-free operation of the air/liquid heat exchanger the quality requirements of the coolant must be maintained; The selection of appropriate anti-corrosion and frost protection agents depends on the environment in which the unit is used and on the external chiller (VDI 3803, see also user manual).

At coolant temperatures below 14 °C, there is an increased risk of condensation. We recommend requesting a customized unit with integrated condensate management.

WARNING
nVent products shall be installed and used only as indicated in nVent’s product instruction sheets and training materials. Instruction sheets are available at www.nvent.com and from your nVent customer service representative. Improper installation, misuse, misapplication or other failure to completely follow nVent’s instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty.

Contact Information

North America
Tel : +1.800.545.6258
Fax : +1.800.527.5703
Email : [email protected]

Europe, the Middle East, and Africa
Tel : +32.16.213.511
Fax : +32.16.213.604
Email : [email protected]

Asia Pacific
Tel : +86.21.2412.1688
Fax : +86.21.5426.3167
Email : [email protected]

Latin America
Tel : +1.713.868.4800
Fax : +1.713.868.2333
Email : [email protected]

© 2023 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of their respective owners.

nVent reserves the right to change specifications without notice.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

nVent User Manuals

Related Manuals