intelbras PSR920-54A-B Power Supply User Manual
- June 16, 2024
- intelbras
Table of Contents
- intelbras PSR920-54A-B Power Supply
- Product Information
- Product Usage Instructions
- Overview
- Technical specifications
- Installing and removing the power supply
- Installing the power supply
- Connecting the power cord
- Removing the power supply
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
intelbras PSR920-54A-B Power Supply
Product Information
Specifications
- AC input: HVDC input
- Rated input voltage range: [insert range]
- Max input voltage range: [insert range]
- Max input current: [insert value]
- Output voltage: [insert value]
- Max output current: [insert value]
- Max output power: [insert value]
- Weight: [insert value]
- Operating temperature: [insert range]
- Relative humidity: [insert range]
Overview
The Intelbras PSR920-54A-B Power Supply is a high-quality power supply unit
that offers self-protection, redundancy, and hot swappable features. It is
designed to provide reliable and stable power to your devices.
Features
- Self-protection: The power supply offers protection against input undervoltage, output overvoltage, short-circuit, output overcurrent, and overtemperature conditions.
- Redundancy: Two power supplies can be connected in parallel to achieve 1+1 redundancy and load sharing.
- Hot swappable: You can remove one of the power supplies in 1+1 redundancy while the device is operating. However, make sure to disconnect the power supply from the external power supply system before removing it.
Description
- The Intelbras PSR920-54A-B Power Supply is equipped with various protection mechanisms to ensure the safety and stability of your devices. It automatically shuts down in case of input undervoltage, short circuit, output overcurrent, or overtemperature conditions. Once the issues are resolved, the power supply will automatically restore power supply.
- In the case of an output overvoltage condition, the power supply will shut down and lock itself. It cannot automatically restore power supply after the issue is resolved. To restore power supply, follow the instructions below.
LEDs
The PSR920-54A-B power supply features two LEDs on its faceplate to
indicate the power input and output status:
- Output status LED (OUT OK): Steady green – Normal power output, Steady red – Abnormal power output, Off – No power output.
- Input status LED (IN OK): Steady green – Normal power input, Steady red – Abnormal power input, Off – No power input.
Product Usage Instructions
Safety Precautions
Before installing or removing the power supply, please ensure the following
safety precautions:
- Use an ESD wrist strap to prevent electrostatic discharge.
- Turn off the circuit breaker for the power feed to the power supply.
Installing the Power Supply
- Unpack the power supply and verify that the input mode is correct.
- Orient the power supply correctly with the lettering facing upward.
- Grasp the handle of the power supply with one hand and support its bottom with the other.
- Slowly slide the power supply along the guide rails into the slot.
- Ensure that the latch on the power supply clicks into place.
- If the power supply slot has a filler panel, gently remove it by putting your finger into the hole and pulling it out.
Connecting the Power Cord
- Connect the female connector of the power cord to the power input receptacle on the power supply.
- Use a cable tie to secure the power cord to the handle of the power supply.
Removing the Power Supply
- Turn off the circuit breaker for the power feed to the power supply.
- Remove the cable tie from the power cord and disconnect the power cord.
- Press the latch towards the handle direction and pull the power supply part way out of the slot.
- Grasp the handle of the power supply with one hand and support its bottom with the other.
- Pull the power supply out of the slot completely.
FAQ
-
Q: What are the safety precautions for installing or removing the power supply?
A: Please use an ESD wrist strap to prevent electrostatic discharge and turn off the circuit breaker for the power feed to the power supply. -
Q: How many power supplies can be connected in parallel for redundancy?
A: Two power supplies can be connected in parallel for 1+1 redundancy and load sharing. -
Q: Can I remove one of the power supplies while the device is operating?
A: Yes, you can remove one of the power supplies in 1+1 redundancy. However, make sure to disconnect the power supply from the external power supply system before removing it.
Intelbras
PSR920-54A-B Power Supply User Manual
Overview
- The PSR920-54A-B is a DC output power supply that supports AC and HVDV power input. It provides a maximum output of 920 W.
- The PSR920-54A-B power supply exhausts air from its faceplate. The following figure shows the PSR920-54A-B power supply.
- The PSR920-54A-B power supply is applicable to multiple switch models. The applicable switch models might change over time. For compatibility of the power supply with switch models, contact the marketing personnel or technical support.
- The restrictions for using the PSR920-54A-B power supply depend on the switch model. For more information, see the installation guide or hardware information and specifications for the switch.
Feature | Description |
---|---|
Self-protection | Provide input undervoltage, output overvoltage, short- |
circuit, output overcurrent, and overtemperature protections.
Redundancy| Two power supplies can be connected in parallel to achieve 1+1
redundancy and load sharing.
Hot swappable| You can remove one of power supplies in 1+1 redundancy while
the device is operating. Before removing the power supply, disconnect the
power supply from the external power supply system.
A power supply shuts down after an input undervoltage, short circuit, output
overcurrent, or overtemperature condition occurs. After the issues are
resolved, it automatically restores power supply.
A power supply shuts down and is locked after an output overvoltage condition
occurs. It cannot restore power supply automatically after the issue is
resolved. To restore power supply, perform the following tasks
- Disconnect the power cord from the external power supply system.
- Disconnect the power cord from the power supply and then reconnect it.
- Connect the power cord to the external power supply system.
Technical specifications
Item | Specifications |
---|
AC input
| Rated input voltage range|
- 100 to 130 VAC @ 50/60 Hz
- 200 to 240 VAC @ 50/60 Hz
Max input voltage range| 90 to 290 VAC @ 47 to 63 Hz
Max input current| 13 A
HVDC input| Rated input voltage range| 240 VDC
Max input voltage range| 180 to 320 VDC
Max input current| 7 A
Output voltage| 56 V
Max output current| 16.5 A
Max output power| 920 W
Dimensions (H × W × D)| 40.2 × 73.5 × 185 mm (1.58 × 2.89 × 7.28 in)
Weight| 1 kg (2.20 lb)
Operating temperature| –10°C to +55°C (14°F to 131°F)
Relative humidity| 5% RH to 95% RH, noncondensing
Item| Specifications
---|---
Storage temperature| -40°C to +70°C (–40°F to +158°F)
LEDs
The PSR920-54A-B power supply provides two LEDs on its faceplate to indicate
the power input and output status.
LED | Mark | Status | Description |
---|---|---|---|
Output status LED |
OUT OK
| Steady green| Normal power output.
Steady red| Abnormal power output.
Off| No power output.
Input status LED| IN OK| Steady green| Normal power input.
Steady red| Abnormal power input.
Off| No power input.
Installing and removing the power supply
Safety precautions
- Wear an ESD wrist strap and make sure the wrist strap makes good skin contact.
- Before installing the power supply, make sure the operating voltage of the external power supply system is as required by the power supply, and the output voltage of the power supply is as required by the powered device.
- To avoid bodily injury, do not touch any bare wire or terminal.
- To avoid power supply damage, do not open the power supply. When the internal circuits or components of the power supply fail, contact Intelbras Support.
- Before installing or removing the power supply, make sure no power cord is connected to the power supply.
Tools
An ESD wrist strap is required for installing and removing the power supply
and connecting the power cord. Prepare an ESD wrist strap yourself.
Installing the power supply
- To prevent damage to the power supply or the connector on the backplane of the powered device, insert the power supply gently.
- If you insert the power supply upside down, you will encounter a hard resistance because of the special structure designs of the slot and power supply. You need to pull out the power supply, orient it correctly, and insert it again.
- Before installing the power supply on a switch, make sure it matches the switch model. For more information, see the installation guide for the switch.
- Keep the filler panel, packaging box, and packaging bags for the power supply secure for future use.
- Unpack the power supply and verify that the input mode of the power supply is as required.
- Correctly orient the power supply (with the lettering on it upward), grasp the handle of the power supply with one hand and support its bottom with the other, and slide the power supply slowly along the guide rails into the slot. Make sure the latch on the power supply clicks into place.
If the power supply slot has a filler panel, put your finger into the hole in the filler panel and then pull the filler panel out of the slot gently.
Connecting the power cord
- Use the power cord provided with the power supply for connection. The power cord provided with the power supply uses a C15 connector that is designed to withstand high temperatures.
- Provide a separate circuit breaker for each power cord.
- Before connecting a power cord, make sure the circuit breaker for the power feed is turned off.
- Connect the female connector of the power cord to the power input receptacle on the power supply.
- Use a cable tie to secure the power cord to the handle of the power supply.
Removing the power supply
- To avoid bodily injury or switch damage, strictly follow the procedure described in this section to remove the power supply.
- If you are not to install a new power supply after removing the old one, install a filler panel in the slot in time.
- Turn off the circuit breaker for the power feed to the power supply.
- Remove the cable tie from the power cord, and then remove the power cord.
- Pressing the latch towards the handle direction, pull the power supply part way out of the slot.
- Grasping the handle of the power supply with one hand and supporting its bottom with the other, pull the power supply slowly out of the slot along the guide rails.
- Put the removed power supply into an antistatic bag.
Box content : 1 x power supply, 1 x 3 meters Brazil standard power cable
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>