MAIER 80.D300 Series Hydrotherapy False Ceiling Instruction Manual

June 16, 2024
MAIER

MAIER 80.D300 Series Hydrotherapy False Ceiling

MAIER-80-D300-Series-Hydrotherapy-False-Ceiling-
product

Installation and maintenance instructions

MAIER-80-D300-Series-Hydrotherapy-False-Ceiling- \(1\) Package contents

  • Art. 80.D400
  • Art. 80.D300
  • Art. 80.K400
  • Art. 80.K200

MAIER-80-D300-Series-Hydrotherapy-False-Ceiling- \(2\)

Tools needed

MAIER-80-D300-Series-Hydrotherapy-False-Ceiling- \(3\) WARNING!
All
installation and maintenance operations require 2 QUALIFIED WORKER?

MAIER-80-D300-Series-Hydrotherapy-False-Ceiling- \(4\)

MAIER-80-D300-Series-Hydrotherapy-False-Ceiling- \(5\)

Hydraulic-electric system layout

80.K703

  • x = 660 mm.
  • Y = 310 mm.
  • z= min 160 mm. / max 700 mm.

80.K503

  • x = 510 mm.
  • Y = 310 mm.
  • z= min 160 mm. / max 700 mm.

MAIER-80-D300-Series-Hydrotherapy-False-Ceiling- \(6\) 80.K702

  • x = 660 mm.
  • Y = 310 mm.
  • z= min 160 mm. / max 700 mm.

80.K502

  • x = 510 mm.
  • Y = 310 mm.
  • z= min 160 mm. / max 700 mm.

MAIER-80-D300-Series-Hydrotherapy-False-Ceiling- \(7\)

Pre-installation information

MAIER-80-D300-Series-Hydrotherapy-False-Ceiling- \(8\)

Installations

MAIER-80-D300-Series-Hydrotherapy-False-Ceiling- \(9\) MAIER-80-D300-Series-Hydrotherapy-False-Ceiling-
\(10\)

MAIER-80-D300-Series-Hydrotherapy-False-Ceiling-
\(11\)Make the connection to the hydraulic/electrical system according to the type showerhead. (see pag. 5/6)

MAIER-80-D300-Series-Hydrotherapy-False-Ceiling-
\(12\)

  • Install the showerhead to the false ceiling and tighten the screw as shown in the figure M, be carrefully, not schrath the surface.

MAIER-80-D300-Series-Hydrotherapy-False-Ceiling-
\(13\)

MAIER-80-D300-Series-Hydrotherapy-False-Ceiling-
\(14\) 80.K400

  • x = 320 mm.
  • Y = 320 mm.
  • z= min 100 mm. / max 700 mm.

80.K200

  • x = 215 mm.
  • Y = 215 mm.
  • z= min 100 mm. / max 700 mm.

MAIER-80-D300-Series-Hydrotherapy-False-Ceiling-
\(15\) 80.D400

  • x = ø 320 mm.
  • z= min 100 mm. / max 700 mm.

80.D300

  • x = ø 220 mm.
  • z= min 100 mm. / max 700 mm.

MAIER-80-D300-Series-Hydrotherapy-False-Ceiling-
\(17\)

MAIER-80-D300-Series-Hydrotherapy-False-Ceiling-
\(18\) MAIER-80-D300-Series-Hydrotherapy-False-
Ceiling- \(19\)

MAIER-80-D300-Series-Hydrotherapy-False-Ceiling-
\(20\)

MAIER-80-D300-Series-Hydrotherapy-False-Ceiling-
\(21\)

Maintenance

Periodically clean the nozzles to remove any lime scale as shown in Illustration “a”

Technical information for the hidraulic system

  • Minimum operating pressure: 1,5 bar
  • Operating Pressure: Optimal recommended use 2.5- 4 bar Maximum operating pressure: 5 bar
  • (for higher hydraulic pressure it is recommended a pressure reducer)
  • Maximum operating temperature: 65 C°
  • Wall mount shower heads are equipped with a 12 l/m flow rate reducer (where possible).

Minimum supply required for false ceiling shower heads:

  • Rain function: 16 l/m – 1.5 bar
  • Cascade function: 10 l/m – 2 bar
  • Double cascade function: 14 l/m – 2 bar

Optimal supply for false ceiling shower heads:

  • Rain function: 18 l/m – 2.5 bar
  • Cascade function: 14 l/m – 2.5 bar
  • Double cascade function: 17 l/m – 2.5 bar

ENVIRONMENTAL PROTECTION
Electrical and electronic equipment is not to be treated as domestic refuse.
Consumers are obliged by law to dispose of no-longer useful electrical and electronic equipment at the appropriate collection or sales points.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals