Product Information

Specifications

  • Voltage of the relay’s coil: 30 V DC / 48 V AC
  • Power consumption: 45 mA max.
  • Number of relays: 1
  • Voltage of the relay’s contacts: N/A (not specified)
  • Tripping voltage T: N/A (not specified)
  • Current of the relay’s contacts: N/A (not specified)
  • Operating temperature: N/A (not specified)
  • Dimensions: N/A (not specified)
  • Net/gross weight: N/A (not specified)
  • Installation Declarations, warranty: N/A (not specified)

Product Usage Instructions

Technical Description

The MP1 (AWZ610) relay module is designed for use in low-voltage installations. It is primarily used for controlling and status indication in alarm or access control systems. The module can be utilized to control devices with high power consumption through the OC outputs of alarm systems. It also provides galvanic isolation of signals and power sources related to the module’s outputs. The module includes two separate T+, T- inputs used for tripping relays based on high or low conditions.

Module Description

The PSU module consists of various components and connectors:

  • [2] +IN- module’s power input
  • [4] LED optical indication:
    • L1 (red): ON – COM contacts, closed NO
    • L1 (red): OFF – COM contacts, closed NC

WEEE Label
According to the European Union WEEE Directive, waste electrical and electronic equipment should be disposed of separately from normal household waste.

FAQ (Frequently Asked Questions)

Q: What is the maximum power consumption of the MP1 relay module?
A: The maximum power consumption of the MP1 relay module is 45 mA.

Q: What is the voltage range for the relay’s coil?
A: The voltage range for the relay’s coil is 30 V DC / 48 V AC.

Q: How many relays are included in the MP1 module?
A: The MP1 module includes 1 relay.

AWZ610
v.1.0
MP1
Relay module
Edition: 3 from 25.11.2022
Supercedes edition: 2 from 01.03.2018

Technical description

The MP1 (AWZ 610 ) relay module is to be used in low voltage installations. It is intended for controlling and status indication in e.g. alarm or access control systems. It may be used to control devices of high power consumption via OC outputs of alarm systems. Moreover, it ensures galvanic isolation of signals, power sources relating to the outputs of the module. It is equipped with two separate T+, T inputs used to trip relays w ith high or low condition.

Module description

Description of components and connectors of the PSU

Element no. [fig. 1] Description
[1] T– , T+ input of voltage controlling relay activity
[2] +IN- module’s power input
[3] Relay contacts:

COM – common relay clamp

NO – normaly open relay clamp

NC – normaly closed relay clamp

[4]| LED optical indication:

L1 (red) ON : COM contacts, closed NO , OFF : COM contacts, closed NC

PULSAR-AWZ610-MP1-Relay-Module-1

Specifications

Voltage of the

relay’s coil

| 12 V (10 V DC ÷ 14 V DC)
---|---
Power

consumption

| 45 mA max.
Number of relays| 1
Voltage of the relay’s contacts| 30 V DC / 48 V AC
Tripping voltage T| T+ 5 V ÷ Unom.

T- 0 V ÷ (Unom. – 5 V)

Current of the

relay’s contacts

| 2A max.
Operating temperature| -10°C ÷ +50°C
Dimensions| L=50, W=43, H=22 [mm, +/-2]
Net/gross weight| 0,03 / 0,05 [kg]
Installation| Installation tape or installation bolt x 2
Declarations,

warranty

| CE, 2 years from production date
Notes| leads on connections: Ø 0,41 ÷ 1,63 (AWG 26-14), 0,2 ÷ 1mm2

PULSAR-AWZ610-MP1-Relay-Module-2

WEEE Label According to the European Union WEEE Directive, waste electrical and electronic equipment should be disposed of separately from normal household waste.

Pulsar sp. j.
Siedlec 150, 32-744 Łapczyca, Poland
Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50
e-mail: biuro@pulsar.pl, sales@pulsar.pl
http://www.pulsar.pl, www.zasilacze.pl

www.pulsar.pl

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals