SKS BIL 30 Test And Measurement Socket Instructions

June 16, 2024
SKS

SKS BIL 30 Test And Measurement Socket

Product Information

  • Specifications
    • Product Name: BIL 30
    • Operating Instruction Article Number/Color: BA403
    • Socket Type: Insulated head and ring socket
    • Installation: Suitable for equipment chassis and switch panels with up to 4 mm wall thickness
    • Socket Material: Gold-plated zinc die-cast
    • Socket Diameter: 4 mm
    • Connection Type: Solder connection
    • Thread Size: M6
    • Rated Voltage Measurement Category (IEC 61010): 30 VAC / 60 VDC O (2)
    • Rated Current: 32 A (derating curve should be considered)
    • Socket Material: SKS_ZINKDRUCKGUSS-VERZINNT
    • Housing Material: PA (Polyamide)
    • Inflammability Class (UL 94): V-2 (valid for basic material of housing)

Product Usage Instructions

  • Installation
    • Select an appropriate equipment chassis or switch panel with up to 4 mm wall thickness.
    • Ensure that the chosen location for installation is suitable for the socket.
    • Drill a hole with a diameter of 4 mm at the desired location.
    • Insert the socket into the hole, making sure the insulated head and ring are properly aligned.
    • If necessary, secure the socket in place using screws or other suitable fasteners.
  • Connection
    • Prepare the wires for connection by stripping off the insulation.
    • Solder the wires to the socket’s solder connections.
    • Ensure that the connections are secure and there is no exposed wire.

FAQS

  • Q: What is the maximum rated voltage for this socket?
  • A: The maximum rated voltage is 30 VAC or 60 VDC.
  • Q: Can this socket be used for circuits directly connected to mains?
  • A: No, this socket does not have a rated measurement category for main circuits. Contact the manufacturer for applications at deviating temperature ranges.
  • Q: What is the inflammability class of the housing material?
  • A: The housing material has an inflammability class of V-2 according to UL 94.
  • Q: Until when is the information provided in this manual valid?
  • A: The information in this manual is valid until 24.08.2022.

Product Description

4 mm system

Manufacturer

  1. contact the manufacturer for applications at deviating temperature ranges
  2. without rated measurement category, for other circuits that are not directly connected to mains
    • stand: 24.08.2022
    • stand: 24.08.2022