PRODUCT DESCRIPTION
NOTES ON THIS MANUAL
Welcome to FIAP GmbH.
With the purchase of the product AQUA ACTIVE you have made a very good
choice.
Before using the device for the first time, read the operating instructions
carefully and familiarize yourself with the product. All work on and with this
device may only be carried out in accordance with this operating manual. It is
essential to observe the safety instructions for correct and safe use. Keep
this manual in a safe place. When changing ownership, please pass on the
operating instructions.
INTENDED USE
AQUA ACTIVE , hereinafter referred to as the device, may only be used for
circulating ponds and for decorative purposes in ornamental waters. The device
may only be used in fresh water. All other parts included in the delivery may
only be used in this appendix. The device may only be operated in the range of
the permissible temperature between + 5 ° C and + 35 ° C. The application area
is for ponds and water basins with and without fish stock. The device must not
be operated:
In swimming ponds, without water flow, in anticipated frost, not in connection
with chemicals, food, combustible or explosive substances.
IMPROPER USE
It may cause improper use and improper handling Hazards arising from this device to persons. In case of improper use, the liability on our part and the general operating permit expire.
CE DECLARATION
Within the meaning of the EC Directive EMC Directive (2014/30 / EU) and
the Low Voltage Directive (2014/35 / EU) we declare the conformity.
The following harmonized standards were applied:
EN 60335-1: 2002 + A1 + A11 + A12, EN 60335-2-41: 2003 + A1, EN 55014-2, EN
61000-3-2, EN 61000-3-3, EN 50366: 2003
SAFETY INSTRUCTIONS
This device may be used by children 8 years old and over, and by persons
with reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, if they have been supervised or instructed in the safe use of
the device and understand the hazards arising therefrom.
Children are not allowed to play with the device. Cleaning and user
maintenance must not be performed by children without supervision. It is
essential to observe the safety instructions for correct and safe use. Keep
this manual carefully. When changing ownership, please pass on the
instructions.
All work with this device may only be carried out in accordance with this
manual.
The combination of water and electricity can cause serious injury to life and
limb if not properly connected or handled.
Operate the device only when there are no persons in the water!
Before reaching into the water, always unplug the power plugs of all devices
in the water.
Compare the electrical data of the power supply with the rating plate on the
packaging or on the device. Make sure that the device is protected by a
residual current device with a maximum rated residual current of 30 mA.
Operate the device only at a properly installed power outlet. Keep the mains
plug and all connection points dry! Lay the connection cable protected so that
damage is excluded. Only use cables, installations, adapters, extension leads
or connecting leads with earthing contact approved for outdoor use. Do not
carry or pull the device by the connecting cable! If the cable or housing is
defective, the device must not be operated! If the mains connection cable of
the device is damaged, the device must be disposed of, it is no longer
possible to replace the mains connection cable. If the cable is damaged,
dispose of the device. Electrical installations on garden ponds must comply
with international and national building regulations. Never open the housing
of the device or its associated parts unless specifically stated in the
instructions for use. Never make technical changes to the device, this leads
to the immediate termination of any warranty and warranty claims. Only use
original spare parts and accessories. Repairs should only be carried out by
authorized service centers. Never operate the device without water flow! Never
pump liquids other than water!
For questions and problems, contact an electrician for your own safety!
SETTING UP AND COMMISSIONING
Watch out! Never operate the device without profiler and without water
flow!
The device should only be operated horizontally and set up stably on solid
ground. The device must be positioned below the water surface and can be
placed inside (submerged) or outside the pond (dry). Mount the supplied
stepped hose nozzles and always use the largest possible inner tube diameter
(the nozzle is sawed off accordingly). In this way you avoid unnecessary power
loss of the pump. Make the hose connection and fix it with a hose clamp. The
unit will turn on automatically once you have made the power connection.
Dry installation: Open the filter bowl and dismantle the already installed skimmer regulation and replace it with the supplied adapter (pipe with thread adapter). Then fit the hose nozzles and close the filter housing. Alternatively, remove the complete pump motor from the housing. The pump can now be put into operation dry. Make sure that all hoses are tightly connected.
Filter system connection: Fasten the hose (25-32-40-50 mm) to the stepped hose nozzle at the pump outlet and secure with a hose clamp. Connect the other end of the hose to the filter system.
Skimmer connection: Put the union nut over the stepped hose nozzle, attach the hose to the skimmer on the stepped hose nozzle, mount it in the inlet regulator of the filter bowl, tighten the union nut. Watch out! If you operate the pump in the filter bowl under water, the skimmer must be connected to the inlet regulator or the inlet regulator must be completely closed! To switch off the device, pull out the mains plug.
CLEANING AND MAINTENANCE
Before every cleaning and maintenance, make sure that the device is switched
off and disconnected from the power source.
The filter housing and the running unit must be cleaned at regular intervals.
The cleaning interval depends heavily on the degree of contamination. The
degree of pollution can vary significantly from body of water to body of
water. First open the filter basket and take out the pump motor. To clean the
rotor and the inner parts, additionally remove the corresponding screws and
pull off the cover of the motor housing. The rotor can then be easily pulled
out of the liner and cleaned. Do not use sharp-edged objects such as brushes
for cleaning. Steel brushes, use a soft sponge instead. Stubborn stains such
as Limescale deposits are best removed with the premium care PUMP CLEANSER
pump cleaner. With sufficient flow, the pump is cooled by the water. Always
make sure that the pump works against as little resistance as possible. If the
flow rate is reduced (for example, if the hose diameter is too small, the ball
valve in the line, the delivery height is too high, contamination, etc.), the
operating temperature rises significantly. Already at 55 degrees Celsius, lime
deposits on the pump motor. In the worst case, this lime layer becomes so
thick that the rotor runs very stiff, blocked and the engine burns. Damage
caused by dirt and calcification is excluded from the guarantee. The user must
properly service and clean the pump depending on the amount of dirt and lime.
After cleaning, reassemble the pump in reverse order.
Observe the relevant product videos on cleaning and maintenance in our Youtube
channel:
https://www.youtube.com/user/FIAPGmbH
WEAR PARTS
The pump must not run dry. Dry running leads to rapid wear and damages the pump permanently. The use in contaminated water with solids and particles also leads to premature wear and negatively affects the life of the pump. Algae or others Plants that settle around the filter basket and can clog it quickly lead to reduced water flow and increased wear. We recommend operating the device exclusively in water without plants or to ensure that no plants can be sucked in. Wear parts are excluded from the warranty. Proper cleaning and care reduce wear on the device.
REPAIR
The motor can not be repaired if the cables or the housing are damaged and
must therefore be replaced. The running unit (rotor + impeller) is available
separately as a spare part.
If you have any questions or problems, contact an electrician or your dealer
for your own safety.
STORAGE
The unit must be taken out of service and dismantled in case of expected frost. First clean the device as described under Cleaning and Maintenance. The device can be stored dry or wet. If the device is to be stored dry, it is important that all components, including the internal engine parts, are completely dry. Put in wet storage Put the cleaned pump in a container filled with fresh tap water. Please note that the container is set up frost-free.
DISPOSAL
The device must be disposed of in accordance with national regulations. This
device must not be disposed of with household waste. Make the device unusable
by cutting off the cables and dispose of them via the return system provided
for this purpose. If lamps are included in the device, they must be disposed
of using the return system provided for this purpose.
Ask your dealer.
Customer Support
FIAP GmbH
Jakob – Oswald – Str. 16
92289 Ursensollen
GERMANY
+49 9628 9213-0
info@fiap.de
www.fiap.com
Technical changes reserved.
For Druckfehler we do not accept any liability.
WEEE Reg. No.: DE78152045
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>