CE LINK LIMITED SG1 Portable 600W Power Station User Manual
- June 16, 2024
- CE LINK LIMITED
Table of Contents
CE LINK LIMITED SG1 Portable 600W Power Station
Parameters
General
Net weight “‘7kg (“‘151bs)
Dimension 301x227x193mm (11.8×8.9×7.Gin)
Battery capacity 512Wh, 25.GV:::, 20Ah
Wi-Fi supported
Output
(UK/EU/FR/AU/ZA)
- AC socket x2 (Inverter mode) pure sine-wave, total G00W (peak 1000W), 220-240V-, S0Hz/G0Hz, 3A
- AC socket (Bypass mode) 220-240V~, S0Hz/G0Hz, 600W Max., 3A
(US)
- AC socket x2 (Inverter mode) pure sine-wave, total G00W (peak 1000W), 100-120V-, G0Hz, GA
- AC socket (Bypass mode) 100-120V~, G0Hz, G00W Max., GA
- USB-Al/A2 SV::: 2.4A, 12W Max.
- USB-Cl/C2 5/9/12/15:::3A, 20V:::SA, 100W Max.
- Car charger 12.GV::: l0A, 12GW Max.
- DC5521 output x2 12.GV:::3A
- Car charge and DC5521 share power, 126W Max.
- Inverter mode: the output AC power comes from the battery, not the grid.
- Bypass mode: the output AC power comes from the grid, not the battery.
Input
(UK/EU/FR/AU/ZA)
- AC input power 1200W Max., GA
- AC input voltage 220-240V~, S0Hz/G0Hz
(US)
- AC input power 1200W Max., l0A
- AC input voltage 100-120V~, G0Hz
Input charging
- AC charging power G00WMax.
- PV / Car charging power 200WMax.
- AC+PV charging power G00WMax.
Battery
- Cell Type lithium iron phosphate battery (LiFePO.)
- Life cycle 3000 cycles
- Protection types over temperature protection, low-temperature protection, over-discharge protection, overcharge protection, overload protection, short circuit protection, over current protection
- Test conditions: 95% DOD, o.sc charge & l.0C discharge at +25±3
Operating temperature
Safety guidelines
Warning
- Do not let a working power station be close to the heat source, such as a fire or heater.
- Do not make power station contact with any liquid.
- Do not use a power station in a strong electrostatic or strong magnetic field environment.
- Do not disassemble the power station in any way or pierce it with a sharp object.
- Do not short the power station by wire or other metal objects.
- It is forbidden to step on, sit or climb on this product.
- Do not use ingenuine parts or accessories. For part or accessory replacement, please visit the official sales channel for purchase information.
- When using a power station, please follow the operating temperature defined in this user manual strictly. If the temperature is too high, the battery may catch fire or even explode. If the temperature is too low, power station performance will be seriously impaired, and even normal use will be impacted.
- Do not stack heavy objects on the power station.
- Do not stop the fan by force or expose the power station in an unventilated or dusty environment when it is working.
- Please avoid collision, drop, and violent vibration. If a severe impact happens, shut down the power supply immediately. Please fix the power station firmly during transportation to avoid vibration and impact.
- If a power station falls into the water accidentally, place it in a safe and wide area, and keep yourself away from it until it’s dry. Dried products shall not be used again. Dispose of it properly according to chapter 2.2 in this user manual. If the power station is on fire, please use fire extinguishing equipment in the recommended order: water or water mist, sand, fire blanket, dry powder, and dioxide carbon fire extinguisher.
- If there is dirt, use a dry cloth to wipe it.
- Place the power station carefully to prevent damage. If the power station is tipped over and seriously damaged, turn off the power station immediately place the battery in a spacious place keep it away from flammable materials and people, and scrap it per the requirements of local laws and regulations.
- Keep power stations out of the reach of children and pets.
- Keep the power station in a dry and ventilated place.
- In humid environments (seaside, water, etc.), it is recommended to equip the power station with a moisture-proof bag. If water is found inside the product, do not use/start it again. Please take countermeasures to prevent electric shock before touching the power station. Put it in a safe and waterproof open area, and contact customer service immediately.
- It is not recommended to use a power station to supply power for safety-related emergency medical equipment, including but not limited to medical grade breathing machine (hospital version CPAP: Continuous Positive Airway Pressure), artificial lung (ECMO, Extracorporeal Membrane Oxygenation). It can be used to supply power for home version CPAP at home and does not require continuous professional monitoring. Please follow your doctor’s advice and consult the manufacturer for any restrictions on the use of the device. For general medical equipment, please pay attention to the power condition to ensure that power does not run out.
- Power supplies will inevitably generate electromagnetic fields when it is in use, which might affect the implantable medical device or normal operation of personal medical devices, such as pacemaker devices, cochlear implants, hearing AIDS, defibrillators, etc. If any of these medical devices are used, please consult the manufacturer about the restrictions on the use to ensure that the power station is operated at a safe distance from implanted medical devices such as pacemakers, cochlear implants, hearing AIDS, defibrillators, etc.
- Power supplies will inevitably generate electromagnetic fields when it is in use, which might affect the implantable medical device or normal operation of personal medical device, such as pacemaker devices, cochlear implants, hearing AIDS, defibrillators, etc. If any of these medical devices are used, please consult the manufacturer about the restrictions on the use to ensure that the power station is operated at a safe distance from implanted medical devices such as pacemakers, cochlear implants, hearing AIDS, defibrillators, etc.
- When the power station is connected to a refrigerator, it may automatically shut down because of the power fluctuation property of the refrigerator. When connecting the power supply to a refrigerator that stores medicine, vaccines or other valuable items, it is recommended to set the AC output to “Never off” in the APP, to ensure continuous power. Users should pay attention to power consumption.
- During the push-pull movement of this product, it is forbidden to put other items on this product.
Discard
- Conditions permitting, be sure to discharge the battery completely, and then put the power station in the specified battery recycling bin. Power stations contains dangerous batteries. It is strictly prohibited to discard them in ordinary dust bins. For details, follow local laws and regulations on battery recycling and disposal.
- If the battery cannot be discharged completely due to product failure, do not discard the battery directly in the battery recycling bin. Contact a professional battery recycling company for further disposal.
- The battery will not start after over-discharge. Please dispose of it as discarded.
Guideline for users
Product Overview
LCD screen
- Battery capacity: When power station is being charged, SOC icon will flicker.
- Wi-Fi connec tion status: The flickering icon indicates that power station is ready for pairing. The icon will keep flickering if a mobile phone and power station are connected by hotspot. After network connection succeeds, the icon will always be on. If connection fails, the icon will be off.
- Please refer to clause 5 for more details regarding error message.
Use
ON AND OFF
- Press the main power switch to turn on the device, then the screen will be lit and the main power indicator will enter the breathing light mode.
- If no operation is performed to the power station for 5 minutes, the power station will enter the hibernation state and the LCD will automatically turn off.
- When there is a load change or operation to the power station, the LCD screen will be automatically lit. Press the main power switch to turn on or turn off the LCD.
- Press and hold the main power switch will turn off the power station.
- In the normal mode (the power is above 5%}, the default standby time of this product is 2 hours; when the AC output switch is not turned on, and there is no charge or discharge for 2 hours, the product will automatically shut down, and the standby time can be Set it on the APP; when the power is 5% or below, the product will be forced to enter the low power mode. In the case of no charge or discharge, the product will adjust the standby time according to the power and automatically shut down.
- In normal mode, long press the LED light button to exit the automatic shutdown setting, and the battery icon[=> on the screen will flash.
- Long press again to enter the automatic shutdown setting, and the battery icon [::} does not flash. (The automatic shutdown setting is to protect the battery from low power, exiting this setting may damage the battery life, please use it with caution.)
Note: When no AC input, long press the above AC output button, you can switch the AC off-grid output frequency ( ). long press 2s to switch, the AC output icon will flash 3 times after successful 3 switching.:
- After the main power switch is turned on, press the 12V DC output power switch to enable the DC output port.
- Press the 12V DC output power switch again to turn it off.
- When the 12V DC output power switch is turned on, power station does not shut down automatically.
AC OUTPUT
- After ensuring that the main power is turned on, short press the AC output power switch to turn on the AC output. Short press the AC output power switch again to turn it off.
- The default standby time of the AC output port is 1 hour. After 1 hour without any load on the AC output port of this product, the AC output power will be automatically turned off. In normal mode, long press the LED light button, the AC output power switch can exit the automatic shutdown setting, and the battery icon on the screen will flash. Long press again, the AC output power switch enters the automatic shutdown setting, and the battery icon does not flash.
- Long press the LED light button to exit the AC automatic shutdown setting: it applies to AC equipment below lOW and pulse working equipment.
- When the AC output is not in use, turn it off to save power consumption.
AC charging
- When the product is turned on, the default fast charging mode is working. If your product has a wifi function, you can control the recharge rate through the APP.
- Please use the standard AC cable for charging. AC charging cable should directly plug into (or above) a wall-mounted socket.
- We take no responsibility for any damage caused by using unofficial AC charging cable, and other failures to follow instructions.
PV charging
[Solar charging cable {DC7909) ]
- Please follow the user manual to connect the solar panels.
- Before connecting the solar panel, check whether its output voltage is within power station specifications to avoid damage to power station.
- The interface of this product is DC7909. If you need an adapter cable from MC4 to DC7909, please purchase it yourself.
Car charging
Car charger cable (DC7909} j
- Power stations can be charged by a car charging port.
- It should be charged after the car starts, to avoid the car battery loss and failure to start.
- At the same time, ensure a good connection between the car charging port and cigarette lighter.
- We take no responsibility for any loss caused by improper operation.
Constant power
- The constant power output function is not enabled by default, which can be turned on or off by the App.
- In the following cases, the constant power output function is not enabled:
- AC output turned on in charging status (bypass mode).
- Constant power output turned off.
- The constant power output function is more suitable for the heater and motor instead of all electrical equipment. It is not suitable for some electrical appliances with voltage protection (such as precision instruments). Constant power output function application is subject to actual testing.
APP
- You can control and view information and data about this product by App.
- For software download, search for [Smart Life] in the Google App Store or Apple App Store, download the software, register and open it or scan the QR code below to download.
- For detailed usage of the APP, please refer to the APP Operation Guide.
EPS function
- This product supports the EPS (emergency backup power) function.
- You connect the power grid and the AC input port of this product through the AC charging cable; Bypass mode (AC power comes from the grid, not the battery); when the grid suddenly loses power, the product can automatically switch to battery power supply mode within l0mS, at this time it is an inverter mode (AC power comes from the battery, not the grid).
- This function does not support Oms switching.
- Please do not connect it to devices that require a high uninterrupted power supply, such as data servers and workstations, or use it after multiple tests to confirm whether it is compatible, It is recommended to use only one device during use, and do not use multiple devices at the same time to avoid overload protection of the product.
- If the device does not operate normally or data is lost due to failure to follow the instructions, our company will not bear the corresponding responsibility.
FAQs (Fre uentlY. Asked Questions)
- What kind of battery is used?
- Lithium iron phosphate battery (LiFePO.).
- What equipment can be connected to the AC output ports?
- The AC output port of the product has high-rated power and the highest power, which can supply power for small power household equipment.
- We suggest confirming the power of the equipment before use to ensure that the sum of the power of all load equipment is lower than the rated power.
- How to know the supply time?
- Time shows in the LCD, which can be referred to for estimation for equipment with stable power consumption.
- How to know it is charging?
- When in charge, the LCD shows the remaining charging time. The SOC flickers and input power is shown.
- How to clean the unit?
- Clean the unit with a dry, soft and clean cloth or tissue.
- How to store the unit?
- Turn it off, and keep it in a dry and ventilated place.
- Do not expose it close to water.
- For long-term storage, suggest discharge to 0% and charge to 100% every 3 months to extend the service life.
Error messages & solutions
What s in the box
Maintenance
- It is recommended to use or store power stations under 20~30°C ambient temperature. Keep it away from water, heater and metal parts.
- For long-term storage, charge and discharge every 3 months, i.e. discharge to 0% then charge to 100%.
- For safety, do not store power stations with temperatures above 45°C or below -l0°C.
- If the capacity is lower than 1 %, please charge to 60%. Long-term storage with serious power shortages will cause irreversible damage to the cell and shorten the service life of the product.
- If the capacity is seriously insufficient and idle time is too long, the product will enter deep sleep mode, and the product can only be used after being charged.
Disclaimer
- The product has a built-in battery management system, which has protections such as overcharge, overdischarge, overcurrent, short circuit, high and low temperature, and abnormal communication.
- During the use of this product, protection may occur and cause output interruption.
- Power supply to special equipment, such as medical equipment, and servers, the indirect loss caused by accidental power failure has nothing to do with the company; all accidents caused by illegal use, self-dismantling, and man-made damage have nothing to do with the company.
- Before using the power station, please read this user manual to ensure understanding and proper use.
- After reading the user manual, please keep it well for future reference.
- Improper operation may cause serious injury to yourself or others, or result in product damage and property loss.
- Once using the power station, you are deemed to have understood and accepted all terms and contents herein.
- Users promise to be responsible for their actions and all consequences arising therefrom. We shall not be liable for any loss arising from users not following this user manual.
- In compliance with laws and regulations, the company reserves the right to the final interpretation of this document and all related documents of this product.
- Subject to update, revision or termination without prior notice, please visit the official website for the latest product information.
FCC Statement
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits
for a class B digital device, according to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used per the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipmemt does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/1V technician for help.
The device has been evaluated to meet general RF exposure requirements, This
equipment should be installed and operated with a minimum distance of 20 cm
between the radiator and your body.
ISED Statement
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s). Operation is subject to the following two conditions: This device may
not cause interference. This device must accept any interference, including
interference that may cause undesired operation of the device. This equipment
should be installed and operated with a minimum distance of 20 cm between the
radiator and your body.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>