MARANI MDA – KDM series High Performance Digital Power Amplifier User Manual

June 16, 2024
MARANI

MARANI MDA – KDM series High Performance Digital Power Amplifier User Manual

Product Information

Box Contents:

  • AMP*1

  • warranty card*1

  • Network cable*1

  • Power Cord*1

Device Connect:

Input connections: Analog signal, Dante (Optional , AES digital signal. (The input signal line should have an independent shielding layer to maintain a distance of 50CM or more from other interference sources)

Panels:

Output connection: Use the Speak ON plug to connect. A/C is the combined output, for example, interface A+1/-1is the A output channel, and interface 2/-2 is the B output channel.

  1. Note: 4.3 inch capacitive touch screen, which can quickly manage input source switching, channel link, network settings, local
    information, etc.

  2. Multi-function button, press or rotate, you can confirm or modify the selected parameters.

  3. USB interface, use Type-B2.0 cable to connect the power amplifier. (Note: The following systems in WIN7 require manual
    installation of drivers. Address: www.marani-proaudio.com)

  4. Analog signal input interface. Before connecting to the signal, please ensure that the amplifier is in a mute or minimumvolumestate. (Factory default analog input)

  5. Digital signal input interface. You need to select a digital signal input source in the software.

  6. TCP/IP network interface, supporting STATIC and DHCP modes, capable of remote control of devices, firmware upgrades, andmore.

  7. Dante network audio interface, support daisy chain connection. https://my.audinate.com/support/downloads/download-latest-dante-software

  8. A/B/C/D output interface, A/C port is a combined output. +1/-1 is the A/C output channel and +2/-2 is the B/Doutput channel.

  9. Power input interface and power switch, connected using Power CON plug, connected to 90-240V 50/60Hz AC power.

Connected operation:

The MDA-KDM series has two connection methods: USB or TCP/IP, and it is recommended to use TCP/IP network connection.

  • USB connection, simply use a Type-B2.0 cable to connect to the power amplifier and open a computer with installed software. Add the corresponding model of power amplifier in the software and select USB connection. Click Off-Line to connect the device.

Add Device

Connected Device

Successfully connected

Common issues with USB connection:

Click ‘OK’ and the device prompts’ Device not found ‘because the software did not recognize a device that can be connected on the COM port. Solution: Open the computer device manager to check whether the port and driver are normal. When the COM port is greater than12, manually change it to the free COM port within 12. If the driver cannot be recognized properly, please try using another USB port on the computer or reinstall the driver. Download address: www.marani-proaudio.com (Note: Drivers belowWIN7needtobemanually installed)

  • Network cable connection, Optional STATIC or DHCP IP mode, use a Category 5/Category 6 network cable to connect the TCP/IP port of the power amplifier to the network adapter interface of the computer. If DHCP mode is selected, ensure that theIPV4 address option in the network adapter of the computer is automatic, and open the software to automatically search for the power amplifier. To select the STATIC mode, you need to adjust the IPV4 address option in the corresponding network ad apterin the Windows network settings to manual IP, and it should be within the same range as the power amplifier IP. Then, open the software to automatically discover the current power amplifier. When the number of connected amplifiers exceeds 5, it is recommended to use STATIC mode to prevent unstable connection due to network congestion. ( Note: When using a static I Connection, if the power amplifier IP is 192.168.0.100, the computer IP should be set to 192.168.0.xxx)

Open software

devices detected

Connected Device

Network cable connection diagram:


Common issues with network cable connection:

  1. After opening the software, it is not possible to automatically search for devices. Solution: Click on the settings icon on the amplifier screen to enter the IP settings page and view the current IP mode of the amplifier. Open the computer’s wired network card network adapter and view the IP mode of Internet Protocol Version4(TCP/IPv4). If the current amplifier selects STATIC mode, the IP address is 192.168.0.100. Set the computer Internet Protocol version 4 (TCP/IP v4) to manual and manually enter the IP address 192.168.0.254. (Note: The IP address of the power amplifieris192.168.0.100, and the computer IP needs to use an IP segment other than 192.168.0.100)
    If the IP address and mode are set correctly, the software cannot search for the amplifier yet. You can first turn off the computer’s wireless network, find the Internet and network in the computer settings, select Windows Firewall, turn off all firewalls, and restart the software to try connecting.
  2. After opening the software, the software prompts: Found MDA4-10kDM@192168.1.100 (UDID: 437F8D4ACB68) The device is UNREACHABLE! Please check your network settings Solution:  The software has found a power amplifier with an IP segment of 192.168.1.100, but cannot connect. Need to check the computer IP settings.

Display screen management:

The MDA-KDM series power amplifier has a 4.3 inch capacitive touch screen, which can quickly manage input source switching, channel linkage, network settings, local information, and more. More precise data adjustment and function confirmation can be achieved through panel buttons.

  1. Turn on the power switch of the amplifier>>>Data loading

    • Recall presets>>>You can retrieve presets that have been saved in the amplifier p Settings menu
    • Channel Mute and Volume Adjustment
    • Input and output signal display
    • Standby Switch
  2. 0.Settings menu

    • Channel Source Settings >>>Selectable from Analog, Digital, Dante, Signal Generator

    • Channel linkage >>>Supports multi-channel linkage

    • Network Settings >>>Can view local IP settings information, supports STATIC and DHCP modes, and can customize IP
      addresses as needed

    • Local information >>>You can view the main information of this device, such as device name, current IP address, firmware version, etc


Software management:

  1. New Project
  2. Importin project Files from a Computer
  3. Save project files to computer
  4. Add a device (you can choose to add a device using USB, TCP/IP)
  5. Search for new devices (search method USB, TCP/IP. TCP/IP can set the search range)
  6. Connect all offline devices currently added
  7. Disconnect all currently connected online devices
  8. All devices exit standby mode
  9. All devices are in standby mode
  10. Add a group (can control the Gain/mute of multiple devices at the same time…)
  11. Level monitoring and mute of all power amplifiers

Navigation Bar – At the top of all amplifier user interfaces

  1. Call in presets from the computer, save presets to the computer, store presets to the amplifier, call up stored presets in the amplifier, and copy channel settings
  2. Amplifier settings, including LAN, name, group reset, preset call mode, amplifier gain, user, administrator
  3. Firmware upgrade, please use a network cable connection to upgrade
  4. Administrator, administrator mode has the highest management permissions for the device, which can encrypt, lock, or hid processor data and functions. Default password: 111111
  5. User interface lock, panel lock (default password: 000000), device identification, data backup, and data recovery
  6. Routing interface, which can be directly accessed by clicking on the function module
  7. All channel level display, level adjustment, mute switch
  8. A/B/C/D input channel, click the corresponding serial number to quickly open the channel processing page.
  9. 1/2/3/4 output channel, click the corresponding serial number to quickly open the channel processing page.
  10. Standby switch, red on, blue off

Software routing interface:


Note: Click on the corresponding function module for quick access

AMP Calibration:

The MDA-KDM series amplifier has added an amplifier calibration function. The amplifier DSP can calibrate the output of the amplifier based on the load feedback signal to achieve more accurate output frequency response of the speaker. (When performing amplifier calibration, the amplifier input signal should be turned off.)
The user can select the impedance value on the corresponding power amplifier output channel according to the Impedance parameters of the speaker used. Then start the calibration function>>>Select the corresponding channel>>Select the data storage location>>Edit name>>Click on calibration>>Wait for calibration to complete>>Verify>>Select verification category>>Verify completed.
| MDA4-10KDM| MDA2-8KDM| MDA4-6KDM| MDA4-4KDM
---|---|---|---|---
2Ω power rms)| –| –| 4 x 800W| 4 x1200W
2.7Ω power(rms)| 4 x 1600W| 2 x 3800W| 4 x 1800W| 4 x1100W
4Ω power(rms)| 4 x 2200W| 2 x 4000W| 4 x 1200W| 4 x 800W
8Ω power(rms)| 4 x 1600W| 2 x 2000W| 4 x 630W| 4 x 400W
70V (rms)| 4 x 2200W| 2 x 4000W| 4 x 1800W| 4 x1200W
100V (rms)| 4 x 2200W| 2 x 4000W| –| –
Analog input| 4 XLR ( MDA2-8KDM  2 XLR
Digital input| 2 x AES/EBU( MDA2-8KDM 1 XLR
Dante input| Dual LAN port / support AES67 (optional)
THD+N| ≦0.03% (1W@4Ω)| ≦0.09% (1W@4Ω)| ≦0.03% (1W@4Ω)| ≦0.04% (1W@4Ω)
S/N(A-wt)| >106dB
Maximum input level| 21dBu / 15dBu
Frequency response| 20Hz~20kHz ±0.8dB
Connected mode| USB Tcp/Ip
Preset quantity| 50
FIR| Input:512 Taps;Output:512Taps
PEQ| Up to 12 PEQ per input channel; Up to 8 PEQ per output channel
Dynamic processing| LF、RMS Limiter
X-Over filter| IIR、FIR、MIR
MARANI Correctionplugin| AUTO EQ/AMP CALIBRATION
Equipment size| 48247088mm 2RU
N.W/G.W| 13.5 Kg /17Kg| 13.2 Kg/16.7Kg| 13.5Kg/17Kg| 12.5Kg/16Kg
Package size| 630x600x140mm

www.marani-proaudio.com
E-mail: info@marani-proaudio.com