Mercoid Series “D” Pressure Controls Bourdon tube power elements, visible setpoint, adjustable deadband or fixed deadband and pressure ranges from 0 to 30 in Hg VAC to 800 to 8000 psig (345 bar).
BENEFITS/FEATURES
- Visible calibrated dial
- On/off indication
- Adjustable, fixed deadband, or manual reset
- External switch setpoint adjustments
- Minimum deadband is obtainable at any point in the range
- Pressure Ranges of full vacuum to 8000 psig.
- UL listed, CSA approved. Many models FM approved.
- General purpose, weatherproof or explosion-proof enclosures
- Single or two stage operation
Location and Mounting
Select a location that is recommended by equipment manufacter and reasonably
free from vibration caused by reciprocating or rotating machinery. Where
excessive vibration occurs, use a remote connection and mount by means of a
mounting bracket or separable flange (available on order). When in doubt about
excessive vibration, use a remote connection. Where pulsations, pres-sure
surges, or water hammer are present, protect the control with a surge tank or
scrubber. Mount all controls vertically and level.
General Purpose Controls: Install controls prefixed by the let-ters DA, DAF, DRF, DL, DS, DSF, firmly in a level position. Do not mount the control by twisting the case; use a wrench on the square part of the 1/4˝ bottom pipe connection. To level, sight across the two cover screws or check the lower end of the glass opening in the cover to see that the control is lined up horizontal-ly. On general purpose controls provided with a flange, mount by means of the three holes in the flange.
SPECIFICATIONS
Wetted Materials: Brass, 403 SS, or 316 SS.
Temperature Limit: 180°F (82°C).
Pressure Limit: Maximum pressure of the operating range. Enclosure
rating: General purpose, weatherproof or explosion-proof.
Repeatability: ±1% of full operating range.
Switch Type: See circuit chart.
Electrical Rating: See electrical ratings chart.
Electrical Connections: Screw terminal.
Conduit Connection: General purpose: 1/2˝ hole for conduit hub.
Weatherproof: 1/2˝ conduit hub. Explosion-proof: 3/4˝ female NPT.
Process Connection: General purpose and weatherproof: 1/4˝ male NPT, 1/2˝
male NPT on ranges 15S and 16S. Explosion-proof: 1/2˝ male NPT and 1/4˝ female
NPT.
Mounting Orientation: Vertical.
Set Point Adjustment: Thumbscrew.
Weight: General Purpose: 4 lb (1.8 kg), weatherproof: 6 lb (2.7 kg),
explosionproof: 8 lb (3.5 kg).
Deadband: See ranges and differentials chart.
ACCESSORIES
Remote Connection
No. 49-62 (300 psi) No. 49-62HP (to 2500 psi)|
Mounting Bracket
No. 33-25|
Pigtail Siphon
No. 42-52 (300 psi)
No. 42-58 (2,000 psi)
---|---|---
General Watertight or Weather-Resistant Types: These controls are
prefixed by the letters DAW, DRW, DSW and DLW. They are supplied with flanged
case, bottom connection only, for surface mounting. Again, install firmly in a
level position. Do not mount the control by twisting the case; use a wrench on
the square part of the 1/4˝ bottom pipe connection. Be sure pipe connection is
in a vertical position. After cover is properly attached, with the name plate
on bottom of the cover, sight across the lower end of the glass opening in the
cover to see that the control is lined up vertically.
Do not use holes in case bottom for mounting.
Explosion-Proof Types: Install controls prefixed by the letters DAH, DAHF, DRH, DSH, DAE, DRE, DSE, firmly in a level position by means of mounting lugs attached to the control housing. Line up horizontally by sighting across the left and right conduit hubs.
Note: Series D-30, D-230, D-430, D-530 (i.e., DA-31-3, etc.), when used
for steam with operating ranges of 35 psi or higher, must be siphoned to
prevent live steam from entering the Bourdon tube. With high pressure steam in
excess of 100 psi, use a remote connection.
Series D-20, D-220, D-420, D-520 (i.e., DA-21-2, etc.), when incorpo-rate an
orifice as standard in the bottom stem to dampen out surges or pul-sations.
WIRING
Wire in accordance with local electrical codes or equipment manufacturer’s
instructions.
For general purpose controls, use a short piece of BX between the rigid
conduit and the control so that it will not be subjected to conduit expan-sion
and contraction. Where control is directly connected into load circuit, it
should be connected into hot side of line. For electrical rating, see name-
plate attached to control case.
ADJUSTMENTS
How to Set Operating Point Double Adjustment Types – Fully Automatic
Prefixed by DA, DAF, DAW, DAH, DAHF – provided with double adjustments. Adjust
the upper pointer “C” to set the HIGH PRESSURE POINT for switch operation.
Adjust the lower pointer “U” to set the LOW U PRESSURE POINT. The differ-ence
between the HIGH and LOW pointers is the operating differential between “on-
off” switch operation.
Double adjustment types – Fully automatic
Single Adjustment Types – Fully Automatic
Prefixed by DS, DSE, DSF, DSH -equipped with a single adjustment. The single
pointer on the scale sets the pressure where switch operation occurs.
Differential is fixed (not adjustable). Example setting: Type DS-21-2, range
0-60 psi: circuit opens on pressure rise. If pointer is set at 40 psi, the
control will operate to OPEN circuit at 40 psi and RE-CLOSE circuit at the
fixed differential of 4 psi.
Single adjustment types – Fully automatic
Semi-Automatic Control with Manual Reset
Prefixed by DR, DRF, DRH, DRE, DRW – with suffix -L or -U. Example: Type
DR21-2U. A single adjustment sets the operating point for automatic operation.
A pushbutton reset must be operated manually to restore the circuit to the
original positionafter automatic operation. Example: Type DA-21-2L. Circuit
will open automatically on a pressure rise to the pressure indicated by the
pointer on the scale. No matter how much the pressure drops, the circuit will
not re-close until the reset button has been operated. Suffix -L denotes
control will operate automatically on an increase in pressure. Suffix -U
denotes control will operate automatically on a decrease in pressure.
Semi-automatic control with manual reset
Manual Lock Type Reset Control
Operates automatically on a decrease of pressure with provision for man-ual
reset when pressure is below set point. Prefixed by DL, DLW, DLE, DLH. A
single adjustment sets the low pressure operating point of the control at any
value on the scale range.
The control will operate automati-cally at the set point only on a drop in
pressure. The lock-type feature per-mits the circuit to be reset and locked in
position when pressures are below control setting. The lock remains in effect
until the pressure has risen to a value above the control setting. Lock then
releases and the circuit is held in the reset position due to the pressure
rise. It will remain in the reset position until it is called on to again
operate automatically on a pressure drop to the selected setting.
Manual lock type reset control
Two-Stage Pressure Controls – Series D-400
Types DA, DAW, DAH, DAE – with suffixes 421, 423, 431, 433, etc., followed by
specification numbers 4122, 4123, 4129, 4132.
This series incorporates two single pole, single throw magnetic mercury
switches, actuated by the same Bourdon tube. The operating point of each
switch is adjustable through an outside adjustment.
The change in pressure which opens and closes each switch at its respective
setting is the switch’s fixed differential. The pressure represented by the
difference between the two adjustment pointers is the pressure “spread”
between operation of the two switches. Upper pointer “U” indicates the
operating point of the HIGH pressure circuit.
Lower point “L” indicates the operating point of the low pressure circuit.
Two-stage pressure controls Series 400
Example Setting: Type DA-421, Specification No. 4122, range 0 to 60 psi.
With lower pointer “L” set at 25 psi and upper pointer “U” set at 50 psi, both
circuits will be closed when pressure is 25 psi and lower. When pressure rises
to 26 psi, mercury switch A will open its circuit. When pressure rises to 50
psi, mercury switch B will open its circuit.
Both switches remain open above this setting. The fixed differential
(sensitivity) of each switch for this particular range is 1 psi. Upon a drop
in pressure, mercury switch “B” will close its circuit at 49 psi; mercury
switch “A” will close its circuit at 25 psi.
LOCKING DEVICE
When the control has been adjusted to desired range, the locking bar may be
inserted between the adjustment screws with slot passing over the hole in the
lug. By placing a sealing wire between the locking bar and the hole in the lug
protruding from the adjustment assembly, adjustments cannot be tampered with.
For DAF, DRF, DSF, DAW, DRW, DSW, the adjusting knob cover may be sealed in
place with sealing wire through the cover bolt hole. For DAH, DSH, sealing
wire may pass through locking bar and hole in hub above the adjusting knobs.
CAUTION: Do not exceed maximum adjustment/operating range of control. Remove control if higher pressures are required.
CAUTION: Do not fail to use a siphon on steam where range is 35 lb or more. Control movement must not be oiled.
CAUTION: Do not overload — note electrical rating on nameplate and be sure total current passing through switch is within specified rating.
CAUTION: Do not tamper with switch wires. Position of these wires is essential to proper operation. Tampering with these wires will void warranty.
Controls with Mercury Switches| Adjustable Differential
Double Adjustment for setting both ‘on and ‘off” operating points Maximum
Differenial – full-scale. Minimum Differential listed below.| Fixed
Differenital
Single Adjustment Adjustable operating point. Differential fixed NOT
ADJUSTABLE
---|---|---
APPLICATION Bourdon tube Material| Adjustable Operating Range
psig| Range Number| DA-31| DA-531| DS-231
Brass Bourdon Tubes| 0-30 Hg VAC
10 in Hg VAC 12
1/8 to 15 psig 1/8 to 20 psig 1 to 35 psig
25 in Hg VAC 50
2 to 60 psig
5 to100 psig
5 to 150 psig
10 to 200 psig
10 to 300 psig
| 2
3
1
3A
4
27
5
6
7
8
9
| 2˝ Hg 1 psig
1 psig
1 psig
1.75 psig
3.5 psig 3 psig
3.75 psig 6 psig
8 psig
12 psig
| 1 in Hg
0.5 psig
0.5 psig
0.5 psig
0.75 psig 2 psig
1 psig
2 psig
3 psig
3.5 psig 6 psig
| 0.2 in Hg 2 oz
2 oz
2 oz
4 oz
7 oz
6 oz
7 oz
8 oz
12 oz
16 oz
| | | DA-21| DA-521| DS-221
403 Stainless Steel Bourdon Tubes| 30 in Hg VAC 60
30 in Hg VAC 75
2 to 60 psig
5 to 100 psig
10 to 200 psig
10 to 300 psig
40 to 350 psig
25 to 600 psig
50 to 1000 psig
100 to 1500 psig
300 to 2500 psig
500 to 5000 psig
800 to 8000 psig
| 25S
26S
5S
6S
8S
9S
9AS
10S
11S
12S
13S
15S
16S
| 6 psig
8 psig
4 psig
6 psig
8 psig
14 psig
14 psig
25 psig
60 psig
90 psig
150 psig
450 psig
750 psig
| 3 psig
4 psig
2.5 psig 3 psig 4 psig 7 psig 7 psig 15 psig 40 psig 50 psig
100 psig
200 psig
400 psig
| 12 oz
12 oz
0.5 psig
0.75 psig
0.75 psig 1 psig
1 psig
2.5 psig 10 psig 12 psig 45 psig 150 psig 200 psig
| | | DA-41| DA-541| DS-241
316 Stainless Steel Bourdon Tubes| 30 in Hg VAC 75
5 to 75 psig
10 to 100 psig
10 to 150 psig
10 to 300 psig
30 to 400 psig
75 to 800 psig
100 to 1000 psig
200 to 2500 psig
| 26E
23E
6E
24E
9E
21E
22E
11E
13E
| 7 psig
3 psig
7 psig
6 psig
18 psig
30 psig
75 psig
100 psig
210 psig
| 35 psig
2 psig
3.5 psig 3 psig 5 psig 15 psig 35 psig 45 psig
110 psig
| 14 oz
0.4 psig 14 oz
0.75 psig 3 psig
5 psig
12 psig
18 psig
50 psig
Note: Differentials listed are for SP-ST operation only. When controls incorporate two mercury switches for double throw or two pole operation, the differentials are approximately double those shown for standard single pole, single throw controls.
Two-Stage Pressure Controls, Series D-400 Ranges and Differentials
Range Number| Adj. Working Range| Bourdon Tube
Material| Minimum Pressure Spread Between Switch Operation|
Fixed Differential Each Switch (Sensitivity)
---|---|---|---|---
For Steam and Other Applications: DA-431, -DAW-433, DAH-431
1| 1/8 to 15 psig| Brass| 2-1/2 psig| 1/2 psig
2| 0 to 30 in Hg VAC| Brass| 4 in Hg| 1 in Hg VAC
3| 10 in VAC 12 psig| Brass| 2-1/2 psig| 1/2 psig
3A| 1/8 to 20 psig| Brass| 2-1/2 psig| 1/2 psig
4| 1 to 35 psig| Brass| 3-1/2 psig| 3/4 psig
5| 2 to 60 psig| Brass| 5 psig| 3/4 psig
6| 5 to 100 psig| Brass| 7 psig| 1 psig
7| 5 to 150 psig| Brass| 10-5/8 psig| 1-1/8 psig
8| 5 to 200 psig| Brass| 15 psig| 1-1/4 psig
9| 10 to 300 psig| Brass| 25 psig| 2 psig
27| 25 in VAC 50 psig| Brass| 7 psig| 1 psig
For General Pressure Applications: DA-421, DAW-423, DAH-421
5S| 2 to 60 psig| Steel| 6 psig| 1-1/4 psig
6S| 5 to 100 psig| Steel| 8 psig| 2 psig
8S| 10 to 200 psig| Steel| 10 psig| 2 psig
9S| 10 to 300 psig| Steel| 20 psig| 4 psig
9AS| 40 to 350 psig| Steel| 20 psig| 4 psig
10S| 25 to 600 psig| Steel| 40 psig| 7 psig
11S| 50 to 1000 psig| Steel| 100 psig| 10 psig
12S| 100 to 1500 psig| Steel| 150 psig| 12 psig
13S| 300 to 2500 psig| Steel| 250 psig| 20 psig
15S| 500 to 5000 psig| Steel| 600 psig| 150 psig
25S| 30 in Hg VAC 60 psig| Steel| 5 psig| 1 psig
26S| 30 in Hg VAC 75 psig| Steel| 10 psig| 2 psig
316 SS Bourdon Tubes: DA-441, DAW-443, DAH-441
26E| 30 in Hg VAC 75| 316 SS| 12 psig| 2 psig
23E| 5 to 75 psig| 316 SS| 12 psig| 2 psig
6E| 10 to 100 psig| 316 SS| 12 psig| 2 psig
24E| 10 to 150 psig| 316 SS| 13 psig| 3 psig
9E| 10 to 300 psig| 316 SS| 35 psig| 6 psig
21E| 30 to 400 psig| 316 SS| 40 psig| 8 psig
22E| 75 to 800 psig| 316 SS| 85 psig| 15 psig
11E| 100 to 1000 psig| 316 SS| 125 psig| 22 psig
13E| 200 to 2500 psig| 316 SS| 275 psig| 75 psig
Two Stage, Series D-400 Switch Operating Specifications
When ordering, select operation desired, add suffix number to type number of
control. Example: Type DA-431-4122.
Specification Number Pressure | Switch Mk. | Contact Position |
---|---|---|
Low Pressure Hi-Vac. | Intermediate Pressure | High |
Pressure Lo-Vac.
-4122| “A”| ON| OFF| OFF
| “B”| ON| ON| OFF
-4129| “A”| OFF| ON| ON
| “B”| OFF| OFF| ON
-4132| “A”| ON| OFF| OFF
| “B”| OFF| OFF| ON
-4123| “A”| OFF| ON| ON
| “B”| ON| ON| OFF
Specification No. 4122. One circuit opens on increase of pressure; second circuit opens on further increase of pressure.
Specification No. 4129. One circuit closes on increase of pressure; second circuit closes on further increase of pressure.
Specification No. 4132. Both circuits open at intermediate pressure. One circuit closes on increase of pressure above neutral zone; second circuit closes on decrease in pressure below neutral zone.
Specification No. 4123. Both circuits close at intermediate pressure. One circuit opens on increase of pressure above neutral zone; second circuit opens on decrease in pressure below neutral zone.
Electrical Ratings D-400
See Code C on Page 5 in Electrical Rating Chart
CIRCUIT CHART
Suffix Number| Circuit| Code| Circuit Response to
Pressure Increase
-2| | SP-ST| A| Opens
-3| | SP-ST| A| Closes
-4| | DP-ST| B| Closes
-26| | SP-ST| A| Closes
-36| | SP-ST| A| Opens
-54| | DP-ST| B| Opens
-103| | DP-ST| A| Closes
-113| | DP-ST| A*| Closes
-127| | DP-ST| A| Opens
-152| | SP-DT| B| One Closes as Other Opens
-153| | SP-DT| B| One Closes as Other Opens
-154| | 2 Circuits
1 Circuit
| B| Close
Opens
-155| | 1 Circuit
2 Circuit
| B| Closes
Open
-156| | SP-DT| A| One Closes as Other Opens
-705| | SP-DT
SP-DT
| B
A
| One Closes as Other Opens
Opens
-729| | SP-ST
SP-DT| B
A| One Closes as Other Opens
Opens
-804| | DP-DT| B| Two Close
Two Open
-815| | | B| 4P-ST Close (2) 9-67
-816| | | B| 4P-ST Open (2) 9-67
*Consult factory.
ELECTRICAL RATING CHART
Code| Circuit Suffix| AC Capacity| DC Capacity|
Horsepower
120 V| 240 V| 440 V| 120 V| 240 V| AC| DC
A
B
C
| -2, -3
-153
-2, -3
-2, -3
| 10A
4A
5A
0.3A
| 5A
2A
2A
0.15A
| 3A
1* NA NA
| 10A
4A
2-1/2A
0.15A
| 5A
2A
1A
0.07A
| 3/4
1/8
1/8
NA
| 1/3
NA 1/10 NA
*Consult factory.
Explosion-proof prefixed by DAH, DAHF DRH, DSH, DSHF
Watertight NEMA 2, 3, 4 – Prefixed by DAW, DRW, DSW, DLW
Explosion-proof prefixed by DAE, DLE, DRE, DSE
©Copyright 2022 Dwyer Instruments, Inc.
Printed in U.S.A. 3/22
FR# 441852-00 Rev. 5
DWYER INSTRUMENTS, INC.
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A.
Phone: 219-879-8000
Fax: 219-872-9057
www.dwyer-inst.com
e-mail: info@dwyermail.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>