Leelbox BQH2800lI Inverter Generating Set Instruction Manual
- June 15, 2024
- Leelbox
Table of Contents
OPERATOR’S MANUAL
ORIGINAL INSTRUCTIONS BQH2800lI/BQH2800ElI
BQH3300lI/BQH3300ElI
INVERTER GENERATING SET
BQH2800lI Inverter Generating Set
Read this manual carefully before operation.
This manual includes important guidance for safety operation.
This Manual contains important safety information and instructions for
operating this generating set.PLEASE READ THIS MANUAL CAREFULLY.
Failure to do so could result in property damage and/or personal INJURY/DEATH.
Provide this manual to any operator of this generating set.
This manual should be considered as a permanent part of your generating set
and should remain with it when you sell it.
All pictures & figures are only one example of series generating set.It shall
be only for reference and perhaps there will be difference between pictures &
figures and physical products.
All information in this publication is based on the latest product information
available at the time of printing.
We reserve the right to change, alter and/or improve the product and this
document at any time without notice and without incurring any obligation.
No part of this publication shall be reproduced without written permission.
Write down the generating set’s serial number and purchase information.Keep
this manual and the receipt for future reference.
Model:
Serial number:
Date of purchase:
Operator safety
- Safety rules
Pay attention to this safety alert symbol.Obey all safety messages that followed by this symbol to avoid possible property damage.INJURY or DEATH.
Each safety message is preceded by a safety alert symbol and one of three words, DANGER,WARNING,or CAUTION.
DANGER
Indicates a hazardous situation which,if not strictly complied with,will
result in substantial property damage,serious injury or DEATH.
WARNING
Indicates a hazardous situation which,if not strictly complied with,may result
in property damage,serious injury or DEATH.
CAUTION
Indicates a hazardous situation which,if not strictly complied with,could
result in property damage or injury.
WARNING
READ THIS MANUAL COMPLETELY BEFORE OPERATING.
DO NOT operate this generating set until you have read ALL safety,Operation,
and maintenance instructions listed in this manual.
Failure to follow the instructions may result in property damage,INJURY or
DEATH.
The warnings and precautions discussed in this manual cannot cover all
possible conditions and situations that may occur.It must be understood by the
operator that common sense and caution are factors which cannot be built into
this product,but must be possessed by the operator.
DANGER
TOXIC FUMES
The exhaust of the engine contains carbon monoxide, an odorless,colorless,
poison gas.Using engine indoors CAN KILL YOU!
NEVER use inside any building or any kind of enclosure,EVEN IF doors and
windows are open.
Place the engine in a well-ventilated area and carefully consider wind and air
currents when positioning the engine.
WARNING
KICKBACK
Rapid retraction of the starter cord will pull hand and arm towards the engine
faster than you can let go.
Unintentional startup can result in entanglement,traumatic amputation or
laceration.
Broken bones,fractures, bruises or sprains.
WARNING
FIRE
Operation of this engine may create sparks that can start fires around
flammable material.
This engine may not be equipped with a spark arresting muffler.If the engine
will be used around flammable materials,or on land covered with materials such
as agricultural crops, forest,brush,grass,or other similar items,then an
approved spark arrester must be installed.
In some area,a spark arrester is required by law.
Please contact local fire agencies for laws or regulations relating to fire
prevention requirements.
Flammable materials can catch fire when they come into contact with hot
surfaces.Do not place flammable objects within 1.5 meters.
WARNING
HOT SURFACE
Engine and generator generate heat during operation,so touching hot surfaces
may cause severe scalding.
Avoid contact with high temperature exhaust gas.
Do not touch the high temperature surface.
Do not touch the generator when it is running or just stopped.
WARNING
Lithium battery is maintenance free,if you have any question,please contact al
local authorized dealer.
DANGER
FIRE OR EXPLOSION
Gasoline is highly flammable and extremely explosive.
Fire or explosion can cause severe burns or death.
Keep flammable items away while handling gasoline.
Fill fuel tank outdoors and in a well-ventilated area with the engine stopped.
Always wipe off spilled fuel and wait until the fuel has dried before starting
the engine.
DO NOT operate the engine with known leaks in the fuel system.
Use proper fuel storage and handling procedures.
DO NOT store fuel or other flammable materials nearby.
Empty the fuel tank before storing or transporting this engine.
Keep fire extinguisher handy and be prepared if a fire starts.
WARNING
Before each use,carefully check the parts for looseness or damage,observe the
oil or fuel for leaks,or other conditions that may affect normal operation.All
damaged or defective parts shall be repaired or replaced without delay.
Be clear about the location of all controls and safety signs.
Ensure that all safety indicators are always in the correct positions and in
the correct working conditions.
Please run the generator on a level surface.
It is forbidden to block the cooling channel with objects.
It is forbidden to expose the generator to excessive humidity or a large
amount of dust.
It is forbidden for children or untrained persons to operate the generator.
It is forbidden to run the generator unattended,so you must turn off the
generator before leaving.
Do not touch the generator when it is running or just stopped.
Keep a space of 0.9 m around the generator to ensure good cooling.
DANGER
MOVING PARTS
Moving parts can cause severe injury.Keep hands and feet away.
DO NOT operate engine with covers,shrouds,or guards removed.
DO NOT wear loose-fitting clothing,dangling drawstrings or items that could
become caught.Tie up long hair and remove jewelry.
The moving parts may catch operator’s hand,feet,hair or clothes that will
cause traumatic amputation or broken bones,fracture.
NEVER place fingers,hands, or body near the engine when it is running.
DANGER
ELECTRIC SHOCK
This generating set produces powerful voltage and the electricity CAN KILL
YOU.
This generating set must be properly connected to an appropriate ground to
help prevent electric shock.
Failure to properly ground generating set can result in
electrocution,especially if the generating set is equipped with a wheel kit.
Consult an electrician for local grounding requirements Installation should be
performed by a certified electrician.
Improper Installation can result in electric shock and death.
To reduce the risk of electric shock.DO NOT use electrical cords that are
worn,frayed,bare or otherwise damaged.
DO NOT touch bare wires or receptacles.
DO NOT operate generating set in wet weather.Keep the generating set dry.
DO NOT handle generating set or electrical cords while standing in water,while
barefoot,or while hands or feet are wet.
Keep children or pets away from the generating set.
DO NOT hook up any generating set to a building electrical system without the
proper use and installation of a transfer switch installed by a qualified
electrician.
When using generating set for backup power,notify utility company.Use approved
transfer generating set to isolate generating set from electric utility.
Failure to isolate generating set from power utility can result in death or
injury to electric utility workers due to backfeed of electrical energy.
Features and controls
① Carrying handle
② Fuel tank cap
③Ventilation knob(If applicable)
④ Control Panel
⑤Recoil starter| ⑥ Transfer switch (CHOKE&RUN&OFF&STOP)
7 Left cover
8 Spark plug maintenance cover
9 Right cover10 Muffler
10 Muffler blind window
---|---
1 Power indicator
2 Overload indicator
3 Running indicator
4 Oil alarm lamp
5 Reset button
6 Fuel display
7 Energy-saving switch| 8 USB port
9 push-button start
10 AC Circuit breaker
11 AC output receptacle
12 12V DC
13 Ground terminal
14 Parallel kit terminal
15 AC American-type three-hole receptacle
---|---
Overload indicator(red)
When the overload indicator is on,it indicates that the generating set is
overload and then the AC protector works.It will stop the output of generating
set to protect the electric equipment and the generating set itself.At this
time,the running indicator (green)is off and the overload indicator(red)is
on,but the engine is still in running state. When the generating set has no
output and the overload indicator is on,please take the following steps:
- Lower the total power of the connected electric devices to the rated output range of generating set.
- Check the air intake for impurities and check the control parts for abnormal situation.Handle immediately if necessary.
- Press the reset button.
Running indicator(green)
The running indicator lights up when generating set starts and has normal
output. Oil alarm lamp(yellow)
When the oil level drops below the lower limit,the oil protection system will
stop the engine automatically and oil alarming lamp will blink by pulling the
recoil starter.The engine will not run until the oil has been filled to the
proper level. Note: If engine flames out or fails to start,turn the
combination switch to “RUN\”position and then pull the recoil starter.If the
oil alarming lamp lights up,it shows lack of oil.Please add appropriate oil
and restart the engine.
Reset button
The reset button is used to restore output if an overload occurs.To restore
output, reduce the loads and press the reset button. Energy-saving switch
When the energy-saving switch is in “ON”position,the energy saving equipment
controls the engine rotate speed according to the connected loads.There will
be good fuel consumption and low noise.
When the energy-saving switch is in“OFF”position,the engine will always run in
rated rotate speed no matter it is connected to the loads or not.
Note: Please set the energy-saving switch to “OFF” position when connect
to air compressor,sinking pump etc., because these equipments need large
starting current. Grounding terminal
The grounding terminal is designed to prevent electric shock by connecting it
to the grounding wire.The generating set must be properly grounded before
operation. Transfer switch (CHOKE &RUN&OFF&STOP)
Note: One-button start and remote control start,no function of manually
close for the choke.
Choke: Close the choke.
Note: Turn to choke position to start when engine is cold,and turn to Run
position to start when engine is hot.
Run: The generating set operates normally.
OFF: Fuel off without stop.
This position can run out of the remaining fuel and improve the reliability of
the generating set.
Note: If you do not plan to use the generator in the near future, please
use this function,or drain the fuel inside the carburetor through the
carburetor drain bolt.
Stop: The stop position of the generator.
Note: After the generating set is unloaded,please run for 3 minutes at no
load to stabilize the temperature,then stop the generating set. Push-button
start
(If applicable)
You can start the generator by pressing the button with your finger.
Parallel kit terminal
It is used for parallel operation with another inverter(parallel kit sold
separately). Parallel kit terminal
It is used for parallel operation with another inverter(parallel kit sold
separately). Fuel tank cap
Remove the fuel tank cap by rotating it anticlockwise. Ventilation knob(If
applicable) The fuel cap is equipped with a ventilation knob to prevent fuel
leakage.During operation,the ventilation knob must be in the “ON”position for
the generator to operate normally.When the generator will not be use for a
long time or needs to be transported,turn the ventilation knob to the
“OFF”position to prevent fuel leakage.
Operating
- Operating checklist
1 Operating Location
Only use OUTSIDE and place the generating setin a well-ventilated area.
Only operate the generating set on a flat,level surface and in a clean,dry
operating environment.
Allow two feet clearance on all side of the generating set while operating it
outdoors.
Operate in specified area,if any problem on applicable occasion, please
consuit the authorized local dealers.In some areas, generating set must be
registered with the local utility.
Generating set used to construction sites may be subject to additional rules
and regulations.
DANGER
TOXIC FUMES
The exhaust of the generating set contains carbon monoxide,Using engine
indoors CAN KILL YOU!
NEVER use inside any building or any kind of enclosure,EVEN IF doors and
windows are open.
Place the generating set in a well-ventilated and clean area.Note the wind
direction and air current when place the generating set.
High altitude
This generating set may require a high altitude carburetor kit to ensure
correct operation at high altitudes.Consult the authorized local dealer for
high altitude kit information if you always operate your engine at altitudes
above 5,000 feet(1,500 meters).
CAUTION
Even with carburetor modification,generating set horsepower will decrease
about 3.5%for each 1,000 feet(300 meters)increase in altitude.The effect of
altitude on horsepower will be greater than this if no carburetor modification
is made.
CAUTION
Operation the engine at altitude below 5,000 feet (1,500 meters)with modified
carburetor may cause the generating set to overheat and result in serious
engine damage.Please restore factory specifications of the carburetor at the
dealer when using the engine in a low altitude area.
2 Operating Condition
Check for loose or damaged parts,signs of oil or fuel leaks, and any other
condition that may affect proper operation.
Repair or replace all damaged or defective parts immediately
WARNING
Failing to correct problem(s) before operation could result in property
damage,serious injury or DEATH.
Clean the dirt or foreign objects on the surface around exhaust and air intake
of generator.
DO NOT move or tip the generating set during operation Use generating set only
for intended uses.If you have questions about intended use, ask your local
dealer.
3 Engine oil check
Place the engine on a level surface with engine stopped.
Check the engine oil level.
Remove the oil maintenance cover. Remove the dipstick and wipe it clean.
Reinstall dipstick into hole;rest on oil fill neck,DO NOT thread cap into
hole.
Remove the dipstick again and check oil level.Level should be between the
upper and lower limit.
Fill to the upper limit of the dipstick with the recommended oil if the oil
level is too low.Reinstall and fully tighten the
dipstick.
Refer to add oil instruction in MAINTENANCE section for more information.
Oil capacity(rated): See Parameters
WARNING
Oil is a major factor affecting performance and service life.
Use 4-stroke automotive detergent oil recommended in the MAINTENANCE section
of this manual.
CAUTION
Operate generating set only on leveled surfaces.The engine is equipped with a
low oil sensor(applicable types) that will automatic stop the engine when the
oil level falls below the safe limit.To avoid the inconvenience of an
unexpected shutdown.Fill to the upper limit and check the oil level regularly.
WARNING
This engine is not filled with oil before send out to the factory.Any attempt
to crank or start the engine before it has been properly filled with the
recommended type and amount of oil may result in engine damage and void your
warranty.
4Generating set fuel check
With the engine stopped,check the fuel level.Refill the fuel tank if
necessary.
Use clean,fresh,regular unleaded gasoline.
DO NOT mix oil with gasoline.
Always wipe up any spilled fuel.
CAUTION
Pressure can build up in the fuel tank.Allow the generating set to cool for at
least two minutes before removing fuel cap.
Loosen the fuel cap slowly to relieve any pressure in the tank.
Be sure not to fill above the upper limit mark.Always allow room for fuel
expansion.
Fuel capacity(rated): See parameters.
DANGER
FIRE OR EXPLOSION
Gasoline is highly flammable and extremely explosive.
Keep flammable items away while handling gasoline.
Fill fuel tank outdoors and in a well-ventilated area with the generating set
stopped.
Always wipe off spilled fuel and wait until the fuel has dried before starting
the generating set.
DO NOT operate the generating set with known leaks in the fuel system.
Regularly check if there is any leak on fuel system.
Use proper fuel storage and handling procedures.DO NOT store fuel or other
flammable materials nearby.
Keep fire extinguisher handy and be prepared if a fire starts.
DANGER
Do not fill the fuel tank above the upper limit.Over fill will result in
engine die or damage the carbon canister (if equipped)and void your warranty.
NEVER use engine or carburetor cleaner products in the fuel tank or permanent
damage may occur.
It is important to prevent gum deposits from forming in essential fuel system
parts, Such as the carburetor,fuel filter,fuel hose or tank during
storage.Also,experience indicates that alcohol-blended fuels(called
gasohol,ethanol or methanol)can attract moisture, which leads to separation
and formation of acids during storage.
Acidic fuel can damage the fuel system of the generating set while in
storage.Be sure to review the instructions given in “Storage\”section.
Gasoline/Alcohol blends:up to 10%alcohol,90%unleaded gasoline by volume is
approved as a fuel.Other gasoline/alcohol blends are not approved.
Effects of old,stale or contaminated fuel are not warrantable.
CAUTION
To minimize gum deposits in your fuel system and to insure easy starting,do
not use gasoline left over from the previous season.
CAUTION
Allow the generating set to cool for at least two minutes before removing fuel
cap when adding fuel.
Loosen the fuel cap slowly to relieve any pressure in the tank.
5 Battery connection
(If applicable) Remove the battery maintenance cover,connect the battery
terminal to the motor terminal,and reinstall the maintenance cover. 6
Electrical devices
Disconnect all electrical devices from the generating set and switch off the
AC circuit breaker before start the engine.
The generating set may be hard to start with electrical devices connected.
The power of connected electrical devices cannot exceed the generating set max
power, specific power see parameter sheet for reference.
7 Generating set grounding
The generating set must be properly connected to an appropriate ground.It
helps prevent electrical shock ifa ground fault condition exists in the
generating set or in connected electrical devices, especially when the unit is
equipped with a wheel kit.
Proper grounding also helps dissipate static electricity,which often builds up
in ungrounded devices.
DANGER
Electrical Shock
Failure to properly ground the generating set can result in electric shock.
A ground terminal has been provided on the generating set.
For remote grounding,connect of A ground terminal has been provided on the
generating set.
For remote grounding,a copper wire that is no small than(4mm2) should be used
between the generator ground terminal and the ground.
The grounding requirements varies from different regions,so we strongly
recommend your to consult a qualified dealer in your area.We strongly
recommend that you consult with a qualified electrician for grounding
requirements in your area.
2.Starting the generating set
-
Perform operating checklist and remove all loads.
-
(Applicable types)
Turn the ventilation knob of fuel cap to the “ON”position to ensure fuel flow.
Note:You don’t need to follow this step,if your generator has no carbon cannister. -
(Suitable for hand start) Cold start
Turn the combination switch to “CHOKE”position to shut off the choke.
Warm start
Turn the combination switch to “RUN”position,if not started, please turn the combination switch to “CHOKE”position before restarting. -
Turn the ECO switch to “ON” position.Please turn the ECO switch to “OFF”position when large starting curent needed.
-
Manual start
WARNING
Check starter cord conditions before operating.Have it replaced immediately by
local authorized dealer if cord is frayed.
-
When starting engine,grasp the recoil starter handle and pull slowly until resistance is felt.
Then pull rapidly to avoid kickback.When pulling the recoil starter,Firmly grasp the generator to avoid tumble of generator or personal injury Caused by tumble. WARNING
KICKBACK
Rapid retraction of the starter cord will pull hand and arm towards the engine faster than you can let go.
Unintentional startup can result in entanglement, traumatic amputation or laceration.Broken bones, fractures,bruises or sprains could result. -
Turn the Transfer switch to “RUN”position.
6electric starting
(Model used)
Cold hot engine start(electric start):Turn the combination switch to
“Run”position.
Press the engine switch and release it after the engine starts. If it fails to
start,release the switch.The unit will restart by itself.If it fails to start
after repeated 5 times,please allow the generator to cool for 1 minute and
start again.
Note:If electric start fails,you may try manual start.
CAUTION
Never continue to start the generator without removing the fault.
It’s forbidden to start the generator after changing to another battery
without authorization.
WARNING
If the generator cannot be started due to the long time storage or improper
use, please follow the manual start steps to manually control the choke and
start the generator.
The generator will automatically charge the lithium battery after normal
operation.
WARNING
If you try to start the generator for three times,and the generator still
cannot start or shut down after start,please find the cause and troubleshoot.
If the generator equipped with oil alarm,the generator will not start if the
oil level in the crankcase is lower than the lowest level.
During the break-in,please do a regular oil inspection,and please perform
maintenance at the recommended interval.
For details,please refer to the maintenance chapter.
WARNING
The engine shall not exceed 15 seconds for each continuous start.If it fails
to start,please allow the generator to cool for 1 minute before next attempt
to start.
Failure to do so will damage the starter motor.
Wireless remote control (If applicable) Operating
- Turn on the remote control switch.
- Press the START button and hold for more than 0.3s for startup.
NOTE: Sometimes the generator can take a few attempts to start in cold
weather.If machine does not start in the first 10 seconds, wait for 30 seconds
before attempting again.
If the motor turns a little then stops when you press the Start button,it may
indicate a low battery.Charge the battery before operation or start by recoil
start.
When electrical device requires a large starting current,please put the
energy-saving switch in the“OFF”position;When the starting current required by
electrical device is small,put the energy-saving switch in the “ON”position.
After completing the operations above,the generator can be connected to
electrical devices. WARNING
It is prohibited to start or close the generating set when the output terminal
of generating set is connected to an electric device and the electric device
is in “ON” state.
3.Connect to electrical devices
-
Inspect power cord for damage before using.
There is a hazard of electrical shock from crushing,cutting or heat damage. -
Make sure that the generating set has been properly grounded.If the electric devices require grounding,the generating set must ground.
-
Make sure that the electric devices are in “OFF” position.
-
Allow the engine to stabilize and warm up for a few minutes after starting.
-
Connect and start the electric devices.
-
Turn off all electric devices and disconnect them from the generating set.
-
If the generating set supplies for several loads or electric devices,start the smallest one first and the largest one last.
DANGER
If connected devices overheat,turn them off and disconnect them from
generating set.
DANGER
ELECTRICAL SHOCK
To reduce the risk of electrical shock,DO NOT use electrical cords that are
worn,frayed,bare or otherwise damaged.
DO NOT touch bare wires or receptacles.
DO NOT handle generating set or electrical cords while standing in water,while
barefoot,or while hands or feet are wet.
Loading capacity
WARNING
DO NOT overload the generating set.
Exceeding the generating set’s capacity can damage the generating set and/or
electric devices connected to it.
You must make sure your generating set can supply enough rated(running)and
(starting)watts for the electrical devices at the same time.
Follow these simple steps to calculate the running and starting watts
necessary for your purposes.
a.Count the electrical devices you will power at the same time.
b.The amount of power you need to run with the devices is the total
rated(running)watts of these items.
c.Starting power is the power needed shortly when electric devices start.Since
not all devices start at the same time, starting power can be estimated by the
maximum power of all devices plus the total power counted in step b.
WARNING
It is necessary to equip with circuit protector or switch to isolate the
generating set from the electric utility when the generating set is mainly
used for backup.Failure to isolate the generating set from the power utility
may result in injury or death to electric utility workers and damage to the
generating set due to back feed of electrical energy.
Wattage Reference Chart
Electric equipment | Rate power(W | Starting power(W |
---|---|---|
Appliances | Tablet TV27″ | 80 |
Energy saving lamb | 5-50 | 5-50 |
Electric cooker | 1000 | 1000 |
Computer | 250 | 250 |
Electric fan | 50 | 100 |
Washing
machine| 250| 500
Refrigerator| 50| 300
Air-conditioner| 1600| 3200
Electric tooling| Electric hammer| 1000| 1500
Impact Hammer| 3000| 6000
Water pump| 2200| 5000
Electric welding machine| 5000| 7500
Air compressor| 5000| 10000
4.Stopping the generating set
-
Remove the connectors of all electric equipment from the generating set panel. WARNING
NEVER stop the engine with electrical devices connected and running. -
Turn the combination switch to the“stop”position,the generator stops operation.
Wireless remote shutdown (if applicable)
Press and hold the “OFF”button for at least 0.3 seconds to stop the generator.After the generator stops,turn the combination switch to the”stop” position.
Note:When the control distance is shortened or the indicator light is on but the remote control function is not available.
Wireless remote replace the battery.Contact your local dealer for more information.
One-button start-stop (if applicable)
Press the start-stop button to turn off the generator.After the generator shutdown,turn the combination switch to“stop” position.
WARNING
If the generator will not be used for a long time,please turn the combination switch to the“off”position.After the fuel in the carburetor oil cup to runs out and the generator automatically shuts down,turn the knob to the “stop”position.
If the combination switch knob is not turned to the “stop” position,there is a risk of fuel leakage.And the battery will be undercharged after a long time placed,resulting in failure (to start the generator. -
(If applicable)
After the generator stops and cools down,turn the fuel tank cap ventilation knob to “OFF” position.
5.Parallel operation
(If applicable)
Make sure that the generating set is in a good running state before connecting
it to other generating sets.The total power of electric devices should not
exceed rated power of generating set.
When electric motor starts,the overload indicator(red)will light up and
normally it will stop within 4 seconds.If it cannot stop,please consult your
local dealer.
During parallel operation, energy-saving switches of generating sets should be
in the same position.
- Connect one generating set to other generating set(s)in parallel.Use the parallel kit to make the parallel connection (the parallel kit needs to be purchased separately).
- Start the engine in proper order and make sure that the running indicator(green)is normal.
- Connect the plug of electric devices to the AC receptacle of parallel kit.
- Run the electric devices.
CAUTION
When overload too much, overload indicator(red)blinks continuously,and the
generating set may be damaged.When overload a little,overload indicator(red)
lights up continuously,it may shorten the service life of generating set.
When continuously operating the generating set,power cannot exceed the rated
power of generating set.
The total power of electric devices cannot exceed the rated power of
generating set.
The manufacturers of electric devices or tools always list the rated power of
similar models or serial number.
Maintenance
It is the operator’s responsibility to complete all scheduled maintenance in a
timely manner.
Correct any issue before operating the generating set.
Always follow the inspection and maintenance recommendations and schedules in
this manual.
WARNING
Improper maintenance or failure to correct a problem before operation can
cause a malfunction and result in property damage,serious injury or DEATH.
Improper maintenance will void your warranty.
DANIGER
Accidental starts can cause Severe injury or death.
Remove the spark plug cap and ground generating set before performing any
service.
CAUTION
The filter element may contains PAHS,PAHS are harmful for your health.Please
wear gloves for protection during air filter maintenance.
- Maintenance schedule
Stop the generating set before serving,disconnect all electric devices and battery(If equipped),and cool down the generating set completely.
Serve the generating set in a clean,dry and flat area,so that no accident would happen during the serving.Please make the wheel in brake state to stop accidental movement of generating set.
Follow the service intervals indicated in the chart below.Service your generating set more frequently when operating in adverse conditions.
Contact your local authorized service dealer for your generating set or engine maintenance needs.| Each time before use| The first month or10 hours note2| Every three months or50 hours note2| Every six months or100 hours note2| Every year or 300 hours note2
---|---|---|---|---|---
Engine oil| Inspection| | | | |
Replacement| | | | |
Air filter| Inspection| | | | |
Cleaning| | | notes
| |
Spark plug| Inspection and adjustment| | | | |
Replacement| | | | |
Spark Extinguisher note1| Cleaning| | | | ****|
Idle speed| Inspection and adjustment| | | | | note4
Valve clearance| Inspection and adjustment| | | | | note4
Carbon Canister note1| Inspection| Every two years notes
Low permeability oil tube note1| Inspection| Every two years notes
Oil tube| Inspection| Every two years notes
NOTE:
Note1:Applicable types(If available).
Note2:Before each season and after then(whichever comes first).
Note3:Service more frequently under severe,dusty,dirty conditions.
Note4:To be performed by knowledgeable,experienced owners or the authorized
dealer.
-
Generating set maintenance
Use a damp cloth to clean exterior surfaces of the generating set.Use a soft brush to clean the dirt and oil.
Use an air compressor (25 PSI) to clear dirt and debris from the generating set.
Inspect all air vents and cooling slots to ensure that they are clean and unobstructed.
WARNING
DO NOT use water to clean the generating set.Water can enter the generating set through the cooling slots and damage the generating set windings.
WARNING
It is forbidden to tamper with the generator in any of the above ways.
Do not tamper with the inverter speed.The generator is set to the correct rated frequency and voltage before factory.Tampering with the factory settings of the inverter |without authorization will void your product warranty. -
Engine maintenance Engine oil
WARNING
The engine is not filled with oil at the factory.Any operation before it has been properly filled with the recommended type and amount of oil may result in engine damage and void your warranty.
Only use four-stroke engine oil of SJ,SL or equivalent level which are in accordance with or higher than API standard.
Check the API label on oil bottle or other container,and make sure the“SJ,SL”or equivalent level letter is in the label.
SAE 10W-30 is recommended for general,all-temperature use.
Other viscosities shown in the chart may be used when the average temperature in your area is within the indicated range.
Recommended Engine Oil
Ambient temperature Oil capacity(rated):
See parameters
Add oil
a.Place the engine on a level Surface.
b.Remove the Right cover c.Remove the dipstick and d.Add recommended oil to
the upper limit. e.Fully tighten the dipstick.
CAUTION
oil level check
Insert the dipstick into filler port and stay at the filler neck.
Do not screw the dipstick into the port,then remove the dipstick and check the
oil level.
f.Dispose of used oil at an approved waste management facility.
Change oil
CAUTION
Change oil when the engine is warm from operation.The oil temperature can
reach up to 140°℃ in the warm state, and careful operation should be taken
when changing the oil to prevent burns.
a.Place the machine on a level surface which is 300mm higher than the ground.
b.Remove the Right cover c.Place the waste oil box on the ground.
d.Remove the oil dipstick,and tilt the machine to pour the oil. e.Add
recommended oil to the upper limit. f.Fully tighten the dipstick.
g.Properly dispose of any used oil at an approved waste management facility.
h.Reinstall the oil maintenance cover.
Air filter
a.Remove the appearance cover.
b.Loosen the filter fix clamp and remove the cover of the air filter.
c.Remove the foam filter element.
d.Wash in liquid detergent and warm water.
e.Squeeze thoroughly dry in a clean cloth.
f.Saturate in clean engine oil.
g.Squeeze in a clean absorbent cloth to remove all excess oil.
h.Assemble the filter element onto the filter unit
i.Assemble the filter fix clamp.
j.Reinstall the appearance cover. WARNING
DO NOT run the engine without the air filter,or serious danger can result.
Spark plug
a.Clean any dirt from the spark plug cap and spark plug base.
b.Remove the spark plug cap.
c.Using socket wrench to loose and remove the spark plug.
d.Inspect the spark plug and spark plug washer,if it was broken or
worn,replace with a new one.Clean the spark plug with wire brush if reuse it.
e.Check spark plug gap.
Carefully bend side electrode to adjust the gap if necessary.
Spark plug gap: 0.6mm-0.8mm f.Carefully thread the plug into the engine by
hand.
g.After the spark plug is seated, use spark plug wrench to tighten the plug.
Spark Plug Tighten Torque: 15-20N.m
h.Attach the spark cap to the plug and connect the spark plug wire to the
plug.
WARNING
Only use recommended spark plug or equivalent.DO NOT use spark plugs that have
improper heat range.
Spark Arrester (Applicable types)
a.Allow the generating set to cool completely before servicing the spark
arrester.
b.Remove the muffler blind window first.
c.Remove the spark arrester screen.
d.Carefully remove the carbon deposits from the spark arrester screen with a
wire brush.
e.Replace the spark arrester if it is damaged.
f.Reinstall the spark arrester in the muffler and reinstall the muffler blind
window. Clean carbon deposit
Trouble-shooting
Failure | Trouble | Solutiom |
---|---|---|
Generating set fails to start | Transfer switch is in “OFF”or “STOP”position. |
When engine is cold,Transfer switch to”CHOKE”,and follow starting procedure to
start the generating set.
When engine is hot,Transfer switch to “RUN”, and follow starting procedure to
start the generating set.
Lack of fuel.| Fill fuel tank per instructions in this manual.
Lack of engine oil.| Check oil level.This engine is equipped with a low oil
sensor.The engine cannot be started unless the oil level is above the
prescribed lower limit.
No ignition.| Remove the spark plug cap.Clean any dirt around the plug
base,and then remove the spark plug.lnstall the spark plug in the plug
cap.Turn the Transfer switch to “RUN” position.Grounding the electrode to any
engine ground,pull the recoil starter to see if sparks jump across the gap.lf
there is no spark,replace the plug.
Reinstall the plug and start engine according to instructions in this manual.
Consult Customer Service if necessary.
Spark plug is splashed by fuel| Remove the spark plug and wipe the fuel.
The generating set flames
out after running fora certain time.| Turn the ventilation knob on the fuel
tank cap to “ON”position;
Check the fuel and oil level.Add them if necessary.
Battery undercharge (electric start)| Charge the battery by starting the
generator manually (at least 30 minutes). After closing the choke
manually,start the generator according to the manual startup steps.
Generating set has no output| Breaker trip| Reset circuit breakers.
Inadequate cord sets or extension cords.| Check cord sets or extension cords
capabilities in section controls;cable size in this manual.
Consult Customer Service if necessary.
Storage and transportation
Storage
The generating set should be started at least once every 2 weeks and allowed
to run for at least 20 minutes.Follow the instructions below for longer term
storage if the generating set will be out of service for 2 months or more.
DANGER
Fire or explosion
Gasoline is highly flammable and extremely explosive.
Empty the fuel tank and shut off fuel valve before storing or transporting
this generating set.
- Allow the generating set to cool completely before storage.
- Clean the generating set according to instructions in Maintenance section.
- Drain all fuel completely from the fuel tank,fuel hose and carburetor to prevent gum from forming.
- Turn the Transfer switch in “STOP”position to cut off the fuel.
- Remive the oil drain plug to drain out the oil(See“Engine oil” section).
- Remove the spark plug and pour about 15 ml of fresh oil into the cylinder.Pull the recoil starter slightly to distribute the oil and lubricate the cylinder.And then attach the spark plug.
- Store the unit in a clean,dry area out of direct sunlight.
- please disconnect the battery.
- Transportation
When generator transportation or short term storage,the generator should be in the normal operating position and fixed vertically to prevent fuel leakage.The combination switch should be in the”stop” position and knob of the fuel cap should be turned to the “OFF”position.
WARNING
When transporting:
Do not overfill the tank.Do not operate the generating set while it is on
vehicle.
Take the generating set off the vehicle and use it in a well-ventilated
place.Avoid a place exposed to direct sunlight when putting the generating set
on a vehicle.
Iif the generating set is left in an enclosed vehicle for many hours,high
temperature inside the vehicle could cause fuel to vaporize resulting in a
possible explosion.Do not drive on a rough road for an extended period with
the generating set on board.If you must transport the generating set on a
rough road,drain the fuel from the generating set beforehand.
Specification
- Specification parameter table
Model
Feature| BQH28001I| BQH3300II
---|---|---
Engine parameter| Engine model| 16SFED/P| 165FED/P
Style| OHV
Displacement(cm3)| 149
Ignition system| CDI
Start style| Hand recoil
Oil capacity(L)| 0.58
Frequency(Hz)| 50| 60| 50| 60
Series parameter| Voltage(V)| 100,100/200,110/220,120/240,110,220,230
Rated power(kW)| 2.3| 2.7
Maximum power(kW)| 2.5| 2.9
Starer power(KW)| 2.8| 3.3
Power factor| 1| 1
Insulation rate| F| F
Fuel capacity(L)| 5.8| 5.8
Operating temperature(t)| -1040| -10∼40
Max.site altitude of installation(m)| 1500| 1500
Measured sound pressure level(dB(A))| ≤72| ≤72
Measurement uncertainty(dB(A))| ≤1.5| ≤1.5
Guaranteed sound
power level(dB(A))| ≤93| ≤93
Net weight(kg)| 21| 21
Model
Feature| BQH2800EII| BQH3300EII
---|---|---
Engine parameter| Engine model| 165FED/P| 165FED/P
Style| OHV
Displacement(cm3)| 149
Ignition system| CDI
Start style| Hand recoil or electric starting
Oil capacity(L)| 0.58
Frequency(Hz)| 50| 60| 50| 60
Series parameter| Voltage(V)| 100,100/200,110/220,120/240,110,220,230
Rated power(kW)| 2.3| 2.7
Maximum power(kW)| 2.5| 2.9
Starer power(KW)| 2.8| 3.3
Power factor| 1| 1
Insulation rate| F| F
Fuel capacity(L)| 5.8| 5.8
Operating temperature(℃)| -10~40| -10~40
Max.site altitude of installation(m)| 1500| 1500
Measured sound pressure level(dB(A))| ≤72| ≤72
Measurement uncertainty(dB(A))| ≤1.5| ≤1.5
Guaranteed sound power level(dB(A))| ≤93| ≤93
Net weight(kg)| /| /
Note: The generating set with different specification and configurations may have different parameters and may change at any time without notice.
- Wiring diagram
Recoil startingElectric starting
NOTE:Because of the difference of generator,the wiring diagram is only for reference.
Read User Manual Online (PDF format)