SMACO S700 Mini Scuba Tank with Full Face Diving Mask User Manual
- June 15, 2024
- SMACO
Table of Contents
SMACO S700 Mini Scuba Tank with Full Face Diving Mask
Product Information
Specifications
- Language Catalog: EN English language, DE Deutsche, RU, IT italiano, CN
- Maximum Applicable Pressure: 3000psi/200bar/20MPa
- Cylinder Volume: 1.9L
Product Structure
- Main Valve Switch : It can be switched off when not in use to avoid air leakage during storage. As the main flow switch of the air outlet channel, it needs to be switched on when in use.
- Medium Pressure Tube: Connecting pipe to output air.
- High-Pressure Cylinder : 1.9L high-pressure cylinder.
- Pressure Gauge: Luminous pressure gauge made of full stainless steel can check the amount of remaining air in the cylinder at any time, even in underwater darkness.
- Explosion-Proof Valve: Provides overpressure protection.
- 8mm Inflation Plug Interface: For air filling.
- Decompression Chamber: High-pressure air in the cylinder is decompressed and output through the decompression chamber.
- Release Valve: Press to release the pressure and discharge the air out of the cylinder.
- Mouthpiece: For divers to bite and breathe through, connecting the inlet and outlet channels of the breathing valve.
Operation Principle
- When the diver bites the mouthpiece and inhales, the pressure in the cavity decreases, prompting the release valve to open downward. This reduces the air pressure in the primary pressure reducing valve and allows it to flow through the medium pressure tube into the secondary breathing valve cavity and then into the oral cavity through the mouthpiece.
- When the diver bites the mouthpiece and exhales, the exhaled gas flows into the cavity, increasing the pressure. This prompts the opening of the one-way silicone gasket at the bottom of the secondary breathing valve, and the gas is discharged to the outside through the two exhaust holes.
Operation Tutorial
-
Assembly
The S700 scuba consists of one primary pressure reducing valve, one high- pressure gas cylinder, one medium-pressure tube, and one secondary breathing valve. When receiving the product, please check for any possible missing parts. Remove the primary pressure reducing valve screw protection sleeve and check the thread connection. After a careful check, tighten the cylinder valve and then install the medium-pressure tube and secondary breathing valve. -
Inflation
Please check for any possible air leakage when inflating. In case of any leakage, stop the inflation immediately. The gas filled should be compressed air (it is strictly forbidden to fill in pure oxygen or other gases harmful to the human body). When the air pressure in the cylinder reaches 3000psi/200bar/20MPa, stop the inflation immediately to avoid any accidents.
Common Troubleshooting
Refer to the troubleshooting section in the user manual for common issues
and solutions.
Storage and Maintenance
Refer to the storage and maintenance section in the user manual for proper
storage and maintenance instructions.
Precautions
Refer to the precautions section in the user manual for important safety
precautions while using the product.
Legal Disclaimer
Refer to the legal disclaimer section in the user manual for important
legal information regarding the product.
FAQ
-
Q: What is the maximum applicable depth for this product?
A: This product is suitable for wading activities such as snorkeling, recreational diving, and indoor diving teaching. The maximum applicable depth is less than 10 meters underwater. However, when used as an underwater emergency rescue or backup air supply for professional diving equipment, the maximum applicable depth is within 30 meters underwater. In this case, it can only be used as an emergency air supply. -
Q: What is the cylinder volume of this product?
A: The cylinder volume of this product is 1.9L.
PRODUCT INTRODUCTION
-
SCENES TO BE USED
-
This product is suitable for wading activities such as snorkeling, recreational diving and indoor diving teaching and the maximum applicable depth is less than 10 meters underwater;
-
When used as an underwater emergency rescue or backup air supply for professional diving equipment, the maximum applicable depth is within 30 meters underwater. In this case, it can only be used as an emergency air supply.
-
Maximum Applicable Pressure
3000psi/200bar/20MPa -
Cylinder Volume
1.9L
PRODUCT STRUCTURE
OPERATION PRINCIPLE
- When the diver bites the mouthpiece and inhales, the pressure in the cavity decreases to prompt the release valve to open downward so that the air pressure is reduced in the primary pressure reducing valve and flows through the medium pressure tube into the secondary breathing valve cavity and then into the oral cavity through the mouthpiece;
- When the diver bites the mouthpiece and exhales, the exhaled gas flows into the cavity to increase the pressure in the cavity, so as to prompt the opening of the one-way silicone gasket at the bottom of the secondary breathing valve, and the gas is discharged to the outside through the two exhaust holes.
OPERATION TUTORIAL
Assembly
S700 scuba consists of one primary pressure reducing valve, one high-pressure
gas cylinder, one medium-pressure tube and one secondary breathing valve. When
receiving the product, please check any possible missing parts. Remove the
primary pressure reducing valve screw protection sleeve and check the thread
connection. After careful check, please tighten the cylinder valve and then
install the medium-pressure tube and secondary breathing valve.
Inflation
- Please check any possible air leakage when inflating. In case of any leakage, stop the inflation immediately; the gas filled is compressed air (it’s strictly forbidden to fill in pure oxygen or other gases harmful to human body). When the air pressure in the cylinder reaches 3000psi /200bar/20MPa, stop the inflation immediately to avoid any accidents;
- Common inflating method: when using an electric air pump or a scuba adapter, the inflating tool needs to ensure that its working pressure is more than 3000psi/200bar/20Mpa, otherwise our products cannot be filled to 3000psi/200bar/20Mpa. When using an electric air pump, an oil-water separator must be equipped to filter the air;
- The compressed air filled shall meet the requirements of human breathing to ensure the air is pure and harmless to human body. If the pure compressed air suitable for human body is not filled as required, the filter system or channel in the cylinder valve may be blocked to cause malfunction.
Pressure Release
Press the release valve on the top of the secondary breathing valve to
release the pressure. If air leakage occurs after air filling, release the
pressure in this way and check the malfunction.
How to Use
- Before use, please check any possible air leakage or water seeping into the breathing cavity of the secondary breathing valve. In case of air leakage, stop using it immediately. In case of water seepage, please drain the water before use. The specific operation is shown as follows:
- Keep all the mouthpiece in mouth and bite the silicon part with teeth, blow 2-3 times into the cylinder valve to ensure the water in the cavity of the secondary breathing valve has been fully discharged, and then have normal breathing with the mouth;
- Keep all the mouthpiece in mouth, bite the silicone part with teeth and shut the mouth tightly. Press the pressure release valve of the secondary breathing valve to discharge the water in the cavity of the secondary breathing valve by the released air, and then have normal breathing with the mouth;
- Check whether there are foreign objects (such as sand, etc.) in the cavity of the secondary breathing valve. If any, please clean up in time before use;
- Use only after safety hazards have been eliminated. When in use, you can breathe normally by biting the mouthpiece completely.
COMMON TROUBLESHOOTING
-
Air leakage at the connection between pressure gauge and cylinder valve / Air leakage at the connection between 8mm inflation plug and the primary pressure reducing valve?
Answer: Use a wrench to tighten the pressure gauge and the inflation plug to eliminate the malfunction. -
Air leakage at the connection between the primary pressure reducing valve and the cylinder?
Answer: Replace the rubber ring at the bottom of the primary pressure reducing valve and tighten to the cylinder to eliminate the malfunction. -
Air leakage at the port of inflation plug?
Answer: Remove the inflation plug, take off the O-shaped rubber ring at the bottom and clean/replace with clean water, wipe off the water and reinstall back to the original place. Make it tightened to eliminate the malfunction.
STORAGE AND MAINTENANCE
-
Storage Conditions:
-
It should be stored in the place with ambient temperature of 5°C~30°C and relative humidity of 40%~70%;
-
It should not be placed within one meter from the heat source and in the direct sunlight;
-
The warehouse where scuba is stored should not have oils, acids, alkalis and other gaseous substances that can damage rubber material.
-
Transportation Conditions:
SMACO S700 scuba is small in size and light in weight, so it’s very convenient to carry. Violent shocks and vibrations during transportation should be avoided. It should be kept clean without contacting with oils, acids, alkalis and other substances that damage rubber and fabrics. -
Product Maintenance
-
This product should be inspected or maintained once a year by an authorized dealer or a professional diving organization to ensure it can be used normally. Cylinders need to be hydrostatically tested every 5 years.
-
An annual visual inspection is recommended and the cylinder should be inspected for corrosion, dents, cracks or other damage, both inside and outside.
-
The O-ring is a vulnerable part. If it is damaged during use, please replace it immediately.
-
Deposit Conditions
The product should be disposed if the following cases occur:
The product itself is damaged, that is, it meets the disposal requirement
and cannot be used any more; for example, the cylinder case is broken, the screw of cylinder valve is damaged or de-formed, the cylinder valve or
cylinder is deformed;
PRECAUTIONS
- This product is suitable for waters within 10 meters deep;
- When used as underwater emergency rescue, the maximum depth can reach 30 meters. At this moment, it can only be used as an emergency backup air supply;
- Before use, you’re strongly recommended to participate in and obtain the scuba diving technical training and related certificates by valid authentication institution. It is dangerous for those who have not been authenticated by professional institution to use this product and serious injury or death may occur;
- This product is suitable for waters above 10 degrees Celsius with the approval by the managers of the waters; please carefully observe the surrounding environment before use to ensure that the waters are safe without any dangers; beware of collisions with passing ships;
- Please inflate the product before use and check any possible damages or air leakage. Do not use when it’s damaged, leaking or has other signs of malfunction;
- The maximum pressure of this product is 20MPa and it can only be filled with compressed air in accordance with the requirements of human breathing. Filling other undesirable gases may cause the internal filtering device and channels to be blocked;
- Please store the product in a cool and dry place away from direct sunlight, do not store it in the car trunk or the place of high temperature, it is forbidden to throw this product into fire;
- It belongs to high-precision product, please do not disassemble the product without authorization. Non-professionals may cause damages to the product;
- Do not use this product in the water alone, more than two companions should be needed;
- In the case of danger, this product cannot provide personal safety protection, it can only provide a proper amount of compressed air to the human body as a source of breathing air;
- After use, make sure to clean the product with clean water and dry it before storage;
- When the pressure is less than 2Mpa, please go to the water surface, then use it after refill air again;
- Please practice in shallow water when use this product for the first time;
- It is strictly forbidden to use this product after drinking alcohol or taking drugs, otherwise it will cause serious consequences;
- It is strictly forbidden for children under 14 years old and seniors over 60 years old to use this product. Juveniles over 14 years old should use it under adult supervision; pregnant women, patients and other people who are not suitable for diving/swimming are prohibited to use this product.
LEGAL DISCLAIMER
Thank you for purchasing/using the SMACO S700 portable scuba.
All the contents mentioned as follows are related to your safety, legal rights
and responsibilities.
- To protect the legitimate rights and interests of the users, please carefully read the user’s manual, legal disclaimer and precautions provided with this product before use. Shenzhen CP-Link Electronic Co., Ltd. reserves the right to update the aforesaid documents. Please use this product in accordance with the instructions and precautions;
- This product is not suitable for those under the age of 14 or over the age of 60 as well as other people who do not have full civil capacity. Pregnant women, patients and other people who are not suitable for diving/swimming are prohibited to use this product. Our company is not responsible for accidents or casualties on those who are not suitable for but insist on using this product;
- Once you start to use this product, it’s deemed that you have read, understood, approved and accepted all the terms and contents of the user’s manual, precautions and legal disclaimer. The user has promised to be responsible for his/her own actions and all the consequences arising therefrom. The user has promised to use this product only for legitimate purposes, and agreed to the terms and any related policies or guidelines that may be formulated by Shenzhen CP-Link Electronic Co., Ltd.;
- When use this product, please make sure to strictly abide by and implement the requirements including but not limited to the user’s manual and precautions. All personal injuries, accidents, property losses, legal disputes and all other conflicts of interest caused by user’s behaviors which violate the contents of the user’s manual or force majeure factors, the user shall bear the relevant responsibilities and losses and Shenzhen CP-Link -Electronic Co -Ltd. will be free from any legal responsibility;
- Shenzhen CP-Link Electronic Co., Ltd. will not bear any responsibility for any violation of the law which occurs directly or indirectly by using this product.
www.smacodive.com
+86 755-28483655
Read User Manual Online (PDF format)