SMACO S300 Plus Portable Scuba Diving Equipment User Manual
- June 12, 2024
- SMACO
Table of Contents
- SMACO S300 Plus Portable Scuba Diving Equipment User Manual
- PRODUCT INTRODUCTION
- SCENES TO BE USED
- Model
- Maximum Applicable Pressure
- Cylinder Valve Material
- Cylinder Volume
- PRODUCT STRUCTURE
- OPERATION PRINCIPLE
- OPERATION TUTORIAL
- Assembly
- Inflation
- OPERATION TUTORIAL
- Pressure Release
- How to Use
- COMMON TROUBLESHOOTING
- Air leakage at the port of inflation plug?
- STORAGE AND MAINTENANCE
- Storage Conditions:
- Transportation Conditions:
- Product Maintenance
- Deposite Conditions
- PRECAUTIONS
- PRECAUTIONS
- LEGAL DISCLAIMER
- Read More About This Manual & Download PDF:
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SMACO S300 Plus Portable Scuba Diving Equipment User Manual
PRODUCT INTRODUCTION
SCENES TO BE USED
- This product is suitable for wading activities such as snorkeling, recreational diving and indoor diving teaching and the maximum applicable depth is less than 10 meters underwater;
- When used as an underwater emergency rescue or backup air supply for professional diving equipment, the maximum applicable depth is within 30 meters underwater. In this case, it can only be used as an emergency air supply.
Model
S300 PLUS
Maximum Applicable Pressure
3000psi/200bar/20Mpa
Cylinder Valve Material
6061 aluminum
Cylinder Volume
PRODUCT STRUCTURE
OPERATION PRINCIPLE
When the diver bites the mouthpiece and inhales, the pressure in the cavity
decreases to prompt the release valve to open downward so that the air flows
out into the oral cavity through the mouthpiece;
When the diver bites the mouthpiece and exhales, the exhaled gas flows into
the cavity to increase the pressure in the cavity, so as to prompt the one-way
silicone gasket in the valve at the bottom of the cylinder to open, and the
gas is discharged to the outside through the two exhaust holes.
OPERATION TUTORIAL
Assembly
S300 PLUS scuba is divided into two parts: the cylinder valve and high-
pressure cylinder. When receiving the product, please check any possible
missing parts.
Remove the screw protection sleeve at the bottom of the cylinder valve and
check the thread connection. After careful check, please tighten the cylinder
valve and have it inflated for use.
Inflation
- Please check any possible air leakage when inflating. In case of any leakage, stop the inflation immediately; the gas filled is compressed air (it’s strictly forbidden to fill in pure oxygen or other gases harmful to human body). When the air pressure in the cylinder reaches 3000psi /200bar/20Mpa, stop the inflation immediately to avoid any accidents;
- Common Inflation Methods: electric pump inflation, manual pump inflation and adapter inflation. When the aforesaid tools are used, please ensure that the pressure can reach 3000psi/200bar/20Mpa, otherwise the cylinder will not be fully filled. When electric pump/manual pump is used for inflation, oil-water separator shall be equipped;
- The compressed air filled shall meet the requirements of human breathing to ensure the air is pure and harmless to human body. If the pure compressed air suitable for human body is not filled as required, the filter system or channel in the cylinder valve may be blocked to cause malfunction.
OPERATION TUTORIAL
Pressure Release
Press the release valve on the top of the cylinder valve to release the
pressure.
If air leakage occurs after air filling, release the pressure in this way and
check the malfunction.\
How to Use
Before use, please check any possible air leakage or water seeping into breathing cavity of the cylinder valve. In case of air leakage, stop using it immediately. In case of water seepage, please drain the water before use. The specific operation is shown as follows:
- Before use, please check any possible air leakage or water seeping into breathing cavity of the cylinder valve. In case of air leakage, stop using it immediately. In case of water seepage, please drain the water before use. The specific operation is shown as follows;
- Keep all the mouthpiece in mouth, bite the silicon part with teeth and shut the mouth tightly. Press the silicone cap on the top of cylinder valve to discharge the water in the breathing cavity by the released air, and then have normal breathing with the mouth;
- Check whether there are foreign objects (such as sand, etc.) in the breathing cavity. If any, please clean up in time before use;
Use only after safety hazards have been eliminated. When in use, you can breathe normally by biting the mouthpiece completely.
COMMON TROUBLESHOOTING
Air leakage at the connection between pressure gauge and cylinder valve / Air
leakage at the connection between 8mm inflation plug and cylinder valve?
Answer: Use a wrench to tighten the pressure gauge and the inflation plug to
eliminate the malfunction
Air leakage at the connection between the cylinder valve and the cylinder?
Answer: Take out the gasket and other accessories at the bottom of the
cylinder valve in order, rearrange them properly and reinstall back in order.
The valve should be aligned with the screw of cylinder and tightened to
eliminate the malfunction.
Air leakage at the port of inflation plug?
Answer: Remove the inflation plug, take off the O-shaped rubber ring at the bottom and clean/replace with clean water, wipe off the water and reinstall back to the original place. Make it tightened to eliminate the malfunction.
STORAGE AND MAINTENANCE
Storage Conditions:
- It should be stored in the place with ambient temperature of 5°C~30°C and relative humidity of 40%~70%;
- It should not be placed within one meter from the heat source and in the direct sunlight;
- The warehouse where scuba is stored should not have oils, acids, alkalis and other gaseous substances that can damage rubber material.
Transportation Conditions:
SMACO S300Plus scuba is small in size and light in weight, so it’s very
convenient to carry. Violent shocks and vibrations during transportation
should be avoided. It should be kept clean without contacting with oils,
acids, alkalis and other substances that damage rubber and fabrics.
Product Maintenance
- This product should be inspected or maintained once a year by an authorized dealer or a professional diving organization to ensure it can be used normally.
- Cylinders need to be hydrostatically tested every 5 years.
- An annual visual inspection is recommended and the cylinder should be inspected for corrosion, dents, cracks or other damage, both inside and outside.
- The O-ring is a vulnerable part. If it is damaged during use, please replace it immediately.
Deposite Conditions
The product should be disposed if the following cases occur:
The product itself is damaged, that is, it meets the disposal requirement and
cannot be used any more; for example, the cylinder case is broken, the screw
of cylinder valve is damaged or de-formed, the cylinder valve or cylinder is
deformed.
PRECAUTIONS
This product is suitable for waters within 10 meters deep;
When used as underwater emergency rescue, the maximum depth can reach 30
meters. At this moment, it can only be used as an emergency backup air supply;
Before use, you’re strongly recommended to participate in and obtain the scuba
diving technical training and related certificates by valid authentication
institution. It is dangerous for those who have not been authenticated by
professional institution to use this product and serious injury or death may
occur;
This product is suitable for waters above 10 degrees Celsius with the approval
by the managers of the waters; please carefully observe the surrounding
environment
before use to ensure that the waters are safe without any dangers; beware of
collisions with passing ships; Please inflate the product before use and check
any possible damages or air leakage. Do not use when it’s damaged, leaking or
has other signs of malfunction;
The maximum pressure of this product is 20MPa and it can only be filled with
compressed air in accordance with the requirements of human breathing. Filling
other undesirable gases may cause the internal filtering device and channels
to be blocked;
Please store the product in a cool and dry place away from direct sunlight, do
not store it in the car trunk or the place of high temperature, it is
forbidden to throw this product into fire;
PRECAUTIONS
It belongs to high-precision product, please do not disassemble the product
without authorization. Non-professionals may cause damages to the product;
Do not use this product in the water alone, more than two companions should be
needed;
In the case of danger, this product cannot provide personal safety protection,
it can only provide a proper amount of compressed air to the human body as a
source of breathing air;
After use, make sure to clean the product with clean water and dry it before
storage;
When the pressure is less than 2Mpa, please go to the water surface, then use
it after refill air again; Please practice in shallow water when use this
product for the first time;
It is strictly forbidden to use this product after drinking alcohol or taking
drugs, otherwise it will cause serious consequences;
It is strictly forbidden for children under 14 years old and seniors over 60
years old to use this product. Juveniles over 14 years old should use it under
adult supervision; pregnant women, patients and other people who are not
suitable for diving/swimming are prohibited to use this product.
LEGAL DISCLAIMER
Thank you for purchasing/using the SMACO S300 PLUS portable scuba.
All the contents mentioned as follows are related to your safety, legal rights
and responsibilities.
-
To protect the legitimate rights and interests of the users, please carefully read the user’s manual, legal disclaimer and precautions provided with this product before use. Shenzhen CP-Link Electronic Co., Ltd. reserves the right to update the aforesaid documents. Please use this product in accordance with the instructions and precautions;
-
This product is not suitable for those under the age of 14 or over the age of 60 as well as other people who do not have full civil capacity. Pregnant women, patients and other people who are not suitable for diving/swimming are prohibited to use this product. Our company is not responsible for accidents or casualties on those who are not suitable for but insist on using this product;
-
Once you start to use this product, it’s deemed that you have read, understood, approved and accepted all the terms and contents of the user’s manual, precautions and legal disclaimer. The user has promised to be responsible for his/her own actions and all the consequences arising therefrom. The user has promised to use this product only for legitimate purposes, and agreed to the terms and any related policies or guidelines that may be formulated by Shenzhen CP-Link Electronic Co., Ltd.;
-
When use this product, please make sure to strictly abide by and implement the requirements including but not limited to the user’s mannual and precautions. All per-sonal injuries, accidents, property losses, legal disputes and all other conflicts of in-terest caused by user’s
behaviors which violate the contents of the user’s manual or force majeure factors, the user shall bear the relevant responsibilities and losses and Shenzhen CP-Link Electronic Co., Ltd. will be free from any legal re- sponsibility; -
Shenzhen CP-Link Electronic Co., Ltd. will not bear any responsibility for any violation of the law which occurs directly or indirectly by using this product.