Winsen ZE15-CO Carbon Monoxide Module User Manual

June 15, 2024
Winsen

Winsen ZE15-CO Carbon Monoxide Module

Product Information

  • Specifications
    • Model No.: ZE15-CO
    • Manufacturer: Zhengzhou Winsen Electronics Technology Co., Ltd
    • Website: www.winsen-sensor.com
    • Date of Issue: 2023.3.27
    • Contact Information: Tel: 86-371-67169097, 67169670
    • Fax: 86-371-60932988
    • Email: sales@winsensor.com.
  • Product Description
    • The ZE15-CO Carbon Monoxide Module is a general-purpose and miniaturization electrochemical carbon monoxide detection module.
    • It utilizes the electrochemical principle to detect CO in air, making the module highly selective and stable.
    • It features a built-in temperature sensor for temperature compensation and offers both digital output and analog voltage output.
    • The module combines a mature electrochemical detection principle with a sophisticated circuit design.
  • Features
    • High sensitivity
    • Fast response
    • Good working stability
    • Pre-calibrated
    • Main Applications
    • Household CO alarm gas
    • CO detector

Technical Parameters

Model No. Detection gas Interfering gases
ZE15-CO Carbon Monoxide CO gas, Alcohol & etc.

Output data:

  • UART output (0 or 3V)
  • Working voltage: 5V-12V DC
  • Preheating time: 30 seconds
  • Response time: 30 seconds
  • Recovery time: 30 seconds
  • Detection range: 0-500ppm
  • Resolution: 0.1ppm
  • Working temperature: -10°C to 55°C
  • Working humidity: 15%RH-90%RH (no condensation)
  • Storage temperature: -10°C to 55°C
  • Life span: 3-5 years in air

Definition of Pins:

  • PIN1: Vin (Input power 5~12V DC)
  • PIN2: GND
  • PIN3: 3.0V output
  • PIN4: Sensor fault output (1Hz, 10% duty cycle)
  • PIN5-PIN8: Reserved
  • PIN9: UART (RXD) TTL 3V Electric Level
  • PIN10: UART (TXD) TTL 3V Electric Level
  • PIN11: Reserved
  • PIN12: Analog Voltage Output (0.4~2V is corresponded to 0~500ppm)
  • PIN13: NC
  • PIN14-PIN15: Reserved

Communication Protocol

General Settings

Baud Rate Data Byte Stop Byte Check Byte
9600 8 bits 1 bit Null

Communication Commands

  • There are two kinds of communication: initiative upload mode and question-and-answer mode. The default setting is initiative upload mode. Modules upload gas concentration values every other 1 second.
    • Note: The module will automatically switch to Q&A mode (question & answer mode) after receiving an inquiry command. The module will automatically switch back to initiative upload mode if no inquiry command is received within 30 seconds under Q&A mode.

Initiative Upload Data Format

Byte0 Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7 Byte8
0xFF 0x04 0x03 0x01 0x00 0x05 0x13 0x88 0x58

Gas name: 0x04 is for CO.

FAQS

  1. What is the working voltage range for the ZE15-CO module?
  2. What is the detection range of the module?
  3. How long is the preheating time?
  4. Can the module detect other gases besides carbon monoxide?
  5. What is the lifespan of the module?

Statement

  • This manual’s copyright belongs to Zhengzhou Winsen Electronics Technology Co., LTD. Without written permission, any part of this manual shall not be copied, translated, or stored in database or retrieval system, also can’t be spread through electronic, copying, or recording ways.
  • Thanks for purchasing our product. To let customers use it better and reduce the faults caused by misuse, please read the manual carefully and operate it correctly following the instructions.
  • If users disobey the terms or remove, disassemble, or change the components inside of the sensor, we shall not be responsible for the loss.
  • The specific such as color, appearance, sizes &etc., please in kind prevail.
  • We are devoting ourselves to product development and technical innovation, so we reserve the right to improve the products without notice.
  • Please confirm it is the valid version before using this manual.
  • At the same time, users’ comments on the optimized using way are welcome.
  • Please keep the manual properly, to get help if you have questions during the usage in the future.

Electrochemical Carbon Monoxide

Electrochemical Carbon Monoxide Gas Module ZE15-CO

Profile

  • ZE15-CO is a general-purpose and miniaturization electrochemical carbon monoxide detection module.
  • It utilizes the electrochemical principle to detect CO in air which makes the module with high selectivity and stability. The built-in temperature sensor can do temperature compensation, and it has digital output and analog voltage output.
  • It is a combination of mature electrochemical detection principles and sophisticated circuit design.

Features

  • High sensitivity, fast response, good working stability, pre-calibrated

Main Applications

  • Household CO alarm gas and CO detector.

Technical Parameters Stable1.

Model No. ZE15-CO

Detection gas

| Carbon Monoxide

(CO gas)

Interfering gases| Alcohol &etc.
Output data| UART output (0 or 3V)
Working voltage| 5V~12V DC
Preheating time| 30S
Response time| ≤30S
Recovery time| ≤30S
Detection range| 0~500ppm
Resolution| 0.1ppm
Working

temperature

| -10℃~55℃

Working humidity

| 15%RH-90%RH(no

condensation)

Storage

temperature

| -10℃~55℃

Definition of pins Stable2.

PIN15 Vin (Input power 5~12V DC)
PIN5、PIN14 GND
PIN1 3.0V output
PIN3 Sensor fault output(1Hz, 10% duty cycle)
PIN4 Reserved
PIN6 Reserved
PIN7 UART (RXD) TTL 3V Electric Level
PIN8 UART (TXD) TTL 3V Electric Level
PIN9 Reserved
PIN10 Analog Voltage Output (0.4~2V is corresponded to 0~500ppm)

PIN2、PIN4、

PIN11、

| NC
PIN12、PIN13| Reserved

Stable2. Pins

Communication Protocol

General Settings

Table 3

Baud Rate 9600
Data Byte 8 bits
Stop Byte 1 bit
Check Byte Null

Communication Commands

There are two kinds of communication, initiative upload mode and question-and- answer mode. The default setting is initiative upload mode. Modules upload gas concentration values every other 1S,
Note: The module will automatically switch to Q&A mode(question & answer mode) after an inquiry command is received; The module will automatically switch to initiative upload mode if no inquiry command is received within 30 seconds under Q&A mode.

Table 4 Initiative upload data format

Byte0 Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7 Byte8
Start Byte **** Gas Type Unit (ppm) No. of decimal Concentration (High
Byte) Concentration (Low Byte) Full Range (High Byte) Full Range (Low
Byte) Checksum
0xFF 0x04 0x03 0x01 0x00 0x05 0x13 0x88 0x58
  • Gas name: 0x04 is for CO.
  • Concentration (High Byte): The highest bit(bit 8) is for sensor fault judgment;
  • Note: sensor fault judgment: 1 is for sensor failure, 0 is for no failure.
  • Gas concentration value = (The low 5 bit of High Byte256+Low Byte)0.1.
  • Full range= full range (high byte)*256+ full range(low byte) (0X1388=5000ppm, which means the module range is 500ppm)

To read gas concentration, the command line format is as follows: Stable5.

Byte0 Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7 Byte8
Start Byte Reserved command Reserved Reserved Reserved Reserved
Reserved Check

sum

0xFF| 0x01| 0x86| 0x00| 0x00| 0x00| 0x00| 0x00| 0x79

Sensor’s return value under Q &A Mode is as follows: Stable6.

Byte0 Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7 Byte8

Start Byte

| ****

command

| Concentration

(High Byte)

| Concentration

(Low Byte)

| ****

Reserved

| ****

Reserved

| Concentration

(High Byte)

| Concentration

(Low Byte)

| Check

sum

0xFF| 0x86| 0x00| 0x05| 0x00| 0x00| 0x00| 0x05| 0x7A

  • Concentration(High Byte): The highest bit(bit 8) is for sensor fault judgment;
  • Note: sensor fault judgment: 1 is for sensor failure, 0 is for no failure.
  • Gas concentration value = (The low 5 bit of High Byte256+Low Byte)0.1.

Check sum and calculation

Check = (negation(byte1+bye2+……+byte7))+1 Please refer the following example:

unsigned char FucCheckSum(unsigned char i,unsigned char ln)
{unsigned char j,tempq=0; i+=1; for(j=0;j<(ln-2);j++) { tempq+=
i; i++; } tempq=(~tempq)+1; return(tempq);}

Cautions

  1. DO NOT insert or extract the sensor on the PCB board.
  2. DO NOT change or move the electronic part of the module.
  3. Avoid sensor contact with organic solvents, coatings, medicine, oil and high-concentration gases.
  4. Excessive impact or vibration should be avoided.
  5. Please keep the modules warming up for at least 5 minutes when first using them.
  6. Please do not use the modules in systems which related to human being’s safety.
  7. Please do not use the modules in a strong air convection environment.
  8. Please do not expose the modules to high-concentration organic gas for a long time.

CONTACT

  • Zhengzhou Winsen Electronics Technology Co., Ltd

  • Add: No.299, Jinsuo Road, National Hi-Tech Zone,

  • Zhengzhou 450001 China

  • Tel: +86-371-67169097/67169670
    Fax: +86-371-60932988

  • E-mail: sales@winsensor.com.

  • Website: www.winsen-sensor.com.

  • Tel: 86-371-67169097 67169670

  • Fax: 86-371-60932988

  • Email: sales@winsensor.com.

  • Leading gas sensing solutions supplier in China!

  • Model No.: ZE15-CO)

  • Version: 1.2

  • Date of issue: 2023.3.27

  • Zhengzhou Winsen Electronics Technology Co., Ltd

  • Zhengzhou Winsen Electronics Technology Co., Ltd

  • www.winsen-sensor.com.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals