Winsen ZE15-CO Carbon Monoxide Module
Product Information
- Specifications
- Model No.: ZE15-CO
- Manufacturer: Zhengzhou Winsen Electronics Technology Co., Ltd
- Website: www.winsen-sensor.com
- Date of Issue: 2023.3.27
- Contact Information: Tel: 86-371-67169097, 67169670
- Fax: 86-371-60932988
- Email: sales@winsensor.com.
- Product Description
- The ZE15-CO Carbon Monoxide Module is a general-purpose and miniaturization electrochemical carbon monoxide detection module.
- It utilizes the electrochemical principle to detect CO in air, making the module highly selective and stable.
- It features a built-in temperature sensor for temperature compensation and offers both digital output and analog voltage output.
- The module combines a mature electrochemical detection principle with a sophisticated circuit design.
- Features
- High sensitivity
- Fast response
- Good working stability
- Pre-calibrated
- Main Applications
- Household CO alarm gas
- CO detector
Technical Parameters
Model No. | Detection gas | Interfering gases |
---|---|---|
ZE15-CO | Carbon Monoxide | CO gas, Alcohol & etc. |
Output data:
- UART output (0 or 3V)
- Working voltage: 5V-12V DC
- Preheating time: 30 seconds
- Response time: 30 seconds
- Recovery time: 30 seconds
- Detection range: 0-500ppm
- Resolution: 0.1ppm
- Working temperature: -10°C to 55°C
- Working humidity: 15%RH-90%RH (no condensation)
- Storage temperature: -10°C to 55°C
- Life span: 3-5 years in air
Definition of Pins:
- PIN1: Vin (Input power 5~12V DC)
- PIN2: GND
- PIN3: 3.0V output
- PIN4: Sensor fault output (1Hz, 10% duty cycle)
- PIN5-PIN8: Reserved
- PIN9: UART (RXD) TTL 3V Electric Level
- PIN10: UART (TXD) TTL 3V Electric Level
- PIN11: Reserved
- PIN12: Analog Voltage Output (0.4~2V is corresponded to 0~500ppm)
- PIN13: NC
- PIN14-PIN15: Reserved
Communication Protocol
General Settings
Baud Rate | Data Byte | Stop Byte | Check Byte |
---|---|---|---|
9600 | 8 bits | 1 bit | Null |
Communication Commands
- There are two kinds of communication: initiative upload mode and question-and-answer mode. The default setting is initiative upload mode. Modules upload gas concentration values every other 1 second.
- Note: The module will automatically switch to Q&A mode (question & answer mode) after receiving an inquiry command. The module will automatically switch back to initiative upload mode if no inquiry command is received within 30 seconds under Q&A mode.
Initiative Upload Data Format
Byte0 | Byte1 | Byte2 | Byte3 | Byte4 | Byte5 | Byte6 | Byte7 | Byte8 |
---|---|---|---|---|---|---|---|---|
0xFF | 0x04 | 0x03 | 0x01 | 0x00 | 0x05 | 0x13 | 0x88 | 0x58 |
Gas name: 0x04 is for CO.
FAQS
- What is the working voltage range for the ZE15-CO module?
- What is the detection range of the module?
- How long is the preheating time?
- Can the module detect other gases besides carbon monoxide?
- What is the lifespan of the module?
Statement
- This manual’s copyright belongs to Zhengzhou Winsen Electronics Technology Co., LTD. Without written permission, any part of this manual shall not be copied, translated, or stored in database or retrieval system, also can’t be spread through electronic, copying, or recording ways.
- Thanks for purchasing our product. To let customers use it better and reduce the faults caused by misuse, please read the manual carefully and operate it correctly following the instructions.
- If users disobey the terms or remove, disassemble, or change the components inside of the sensor, we shall not be responsible for the loss.
- The specific such as color, appearance, sizes &etc., please in kind prevail.
- We are devoting ourselves to product development and technical innovation, so we reserve the right to improve the products without notice.
- Please confirm it is the valid version before using this manual.
- At the same time, users’ comments on the optimized using way are welcome.
- Please keep the manual properly, to get help if you have questions during the usage in the future.
Electrochemical Carbon Monoxide
Electrochemical Carbon Monoxide Gas Module ZE15-CO
Profile
- ZE15-CO is a general-purpose and miniaturization electrochemical carbon monoxide detection module.
- It utilizes the electrochemical principle to detect CO in air which makes the module with high selectivity and stability. The built-in temperature sensor can do temperature compensation, and it has digital output and analog voltage output.
- It is a combination of mature electrochemical detection principles and sophisticated circuit design.
Features
- High sensitivity, fast response, good working stability, pre-calibrated
Main Applications
- Household CO alarm gas and CO detector.
Technical Parameters Stable1.
Model No. | ZE15-CO |
---|
Detection gas
| Carbon Monoxide
(CO gas)
Interfering gases| Alcohol &etc.
Output data| UART output (0 or 3V)
Working voltage| 5V~12V DC
Preheating time| 30S
Response time| ≤30S
Recovery time| ≤30S
Detection range| 0~500ppm
Resolution| 0.1ppm
Working
temperature
| -10℃~55℃
Working humidity
| 15%RH-90%RH(no
condensation)
Storage
temperature
| -10℃~55℃
Definition of pins Stable2.
PIN15 | Vin (Input power 5~12V DC) |
---|---|
PIN5、PIN14 | GND |
PIN1 | 3.0V output |
PIN3 | Sensor fault output(1Hz, 10% duty cycle) |
PIN4 | Reserved |
PIN6 | Reserved |
PIN7 | UART (RXD) TTL 3V Electric Level |
PIN8 | UART (TXD) TTL 3V Electric Level |
PIN9 | Reserved |
PIN10 | Analog Voltage Output (0.4~2V is corresponded to 0~500ppm) |
PIN2、PIN4、
PIN11、
| NC
PIN12、PIN13| Reserved
Stable2. Pins
Communication Protocol
General Settings
Table 3
Baud Rate | 9600 |
---|---|
Data Byte | 8 bits |
Stop Byte | 1 bit |
Check Byte | Null |
Communication Commands
There are two kinds of communication, initiative upload mode and question-and-
answer mode. The default setting is initiative upload mode. Modules upload gas
concentration values every other 1S,
Note: The module will automatically switch to Q&A mode(question & answer
mode) after an inquiry command is received; The module will automatically
switch to initiative upload mode if no inquiry command is received within 30
seconds under Q&A mode.
Table 4 Initiative upload data format
Byte0 | Byte1 | Byte2 | Byte3 | Byte4 | Byte5 | Byte6 | Byte7 | Byte8 |
---|---|---|---|---|---|---|---|---|
Start Byte | **** Gas Type | Unit (ppm) | No. of decimal | Concentration (High | ||||
Byte) | Concentration (Low Byte) | Full Range (High Byte) | Full Range (Low | |||||
Byte) | Checksum | |||||||
0xFF | 0x04 | 0x03 | 0x01 | 0x00 | 0x05 | 0x13 | 0x88 | 0x58 |
- Gas name: 0x04 is for CO.
- Concentration (High Byte): The highest bit(bit 8) is for sensor fault judgment;
- Note: sensor fault judgment: 1 is for sensor failure, 0 is for no failure.
- Gas concentration value = (The low 5 bit of High Byte256+Low Byte)0.1.
- Full range= full range (high byte)*256+ full range(low byte) (0X1388=5000ppm, which means the module range is 500ppm)
To read gas concentration, the command line format is as follows: Stable5.
Byte0 | Byte1 | Byte2 | Byte3 | Byte4 | Byte5 | Byte6 | Byte7 | Byte8 |
---|---|---|---|---|---|---|---|---|
Start Byte | Reserved | command | Reserved | Reserved | Reserved | Reserved | ||
Reserved | Check |
sum
0xFF| 0x01| 0x86| 0x00| 0x00| 0x00| 0x00| 0x00| 0x79
Sensor’s return value under Q &A Mode is as follows: Stable6.
Byte0 | Byte1 | Byte2 | Byte3 | Byte4 | Byte5 | Byte6 | Byte7 | Byte8 |
---|
Start Byte
| ****
command
| Concentration
(High Byte)
| Concentration
(Low Byte)
| ****
Reserved
| ****
Reserved
| Concentration
(High Byte)
| Concentration
(Low Byte)
| Check
sum
0xFF| 0x86| 0x00| 0x05| 0x00| 0x00| 0x00| 0x05| 0x7A
- Concentration(High Byte): The highest bit(bit 8) is for sensor fault judgment;
- Note: sensor fault judgment: 1 is for sensor failure, 0 is for no failure.
- Gas concentration value = (The low 5 bit of High Byte256+Low Byte)0.1.
Check sum and calculation
Check = (negation(byte1+bye2+……+byte7))+1 Please refer the following example:
unsigned char FucCheckSum(unsigned char i,unsigned char ln)
{unsigned char j,tempq=0; i+=1; for(j=0;j<(ln-2);j++) { tempq+=i; i++; }
tempq=(~tempq)+1; return(tempq);}
Cautions
- DO NOT insert or extract the sensor on the PCB board.
- DO NOT change or move the electronic part of the module.
- Avoid sensor contact with organic solvents, coatings, medicine, oil and high-concentration gases.
- Excessive impact or vibration should be avoided.
- Please keep the modules warming up for at least 5 minutes when first using them.
- Please do not use the modules in systems which related to human being’s safety.
- Please do not use the modules in a strong air convection environment.
- Please do not expose the modules to high-concentration organic gas for a long time.
CONTACT
-
Zhengzhou Winsen Electronics Technology Co., Ltd
-
Add: No.299, Jinsuo Road, National Hi-Tech Zone,
-
Zhengzhou 450001 China
-
Tel: +86-371-67169097/67169670
Fax: +86-371-60932988 -
E-mail: sales@winsensor.com.
-
Website: www.winsen-sensor.com.
-
Tel: 86-371-67169097 67169670
-
Fax: 86-371-60932988
-
Email: sales@winsensor.com.
-
Leading gas sensing solutions supplier in China!
-
( Model No.: ZE15-CO)
-
Version: 1.2
-
Date of issue: 2023.3.27
-
Zhengzhou Winsen Electronics Technology Co., Ltd
-
Zhengzhou Winsen Electronics Technology Co., Ltd
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>