SANDOZ 46302910 SurePal 15 GB Booket User Guide

June 15, 2024
SANDOZ

SANDOZ Logo SurePal™ 15
User‘s Guide
Instructions for use
SANDOZ 46302910 SurePal 15 GB
Booket

Personal notes

Please fill out before the first use of your SurePal 15:
Name of patient
Date of first use
Use by date

Lot number (see on package)
Prescribed on [date] Dose [mg] * The SurePal 15 can be used for two years from the date of first use.
It is highly recommended that patients receive training on the SurePal 15 prior to their first injection.
These instructions will help you use your SurePal 15 safely and correctly.
Read and follow all the instructions even if you have used a different type of injection pen.
If you don’t follow these instructions, you may not get the proper dosage from your injections, and this may endanger your health.

What you need

Product contentsSANDOZ 46302910 SurePal 15 GB Booket - Product
contents A Hard Case
B Needle Hider
C SurePal 15
Your SurePal   15 comes with a needle hider, a case, and a user’sguide.

What you need to get from your pharmacy
Omnitrope ® (somatropin) 15 mg / 1.5 mL
Alcohol wipe
“Sharps container”
Pen needles

Pen needle BD 29G
Needle length: 12.7 mm
Pen needle BD 31G
Needle lengths: 5 mm; 8 mm

Meet your SurePal 15

Intended use SurePal 15 is intended for subcutaneous (under the skin) injection of a daily dose of Omnitrope ® (rhGH drug).
It is intended for patients (paediatric patients and adults) treated for growth disturbances and growth hormone deficiencies.
The injection can be performed by the patient him/ herself or also by a trained caregiver in case of small children or patients unable to perform the injection themselves.
The device is a multi-dose, needle- based injection system with automated functions to be used with the liquid formulation Omnitrope ® in a standard 1.5 mL disposable pre-assembled cartridge.

Medication
The SurePal 15 should only be used with a pre-assembled Omnitrope ® (somatropin) 15 mg / 1.5 mL cartridge. One pre-assembled cartridge holds multiple doses.
For more information about Omnitrope® , see the package insert or speak to your doctor or pharmacist.

Package symbols and their meanings

**** Consult instructions for use
Warning of risks that arise when handling the  SurePal 5
**** Manufacturer
**** Date of manufacture
Catalogue number
Lot number
Keep away from sunlight
Do not freeze
Temperature limits: store within these temperature limits

Pen needle
To prevent contamination, leave the pen needle in the package until just before you are going to use it.

General safety instructions
**Handle the SurePal  15 with care and keep it clean.
**
Always wash your hands before using the SurePal  15.
****Use a new pen needle from a sterile package for each injection.

Safety precautions

Never share your SurePal™ 15!
The SurePal 15 should only be used by the patient for whom it was pre scribed. There is a considerable risk of transmission of infections if the SurePal 15 is shared with anyone else besides the intended patient. If more than one person in your household uses a SurePal 15, make sure each device is labeled clearly so they can’t be mixed up.

Advice for caregivers
If you are giving others their injections, take care and work with a steady hand.
Be careful not to accidently stick yourself because this could result in spreading germs or infections.
Keep out of sight and reach of children.

SurePal 15 pen parts

SANDOZ 46302910 SurePal 15 GB Booket - pen parts

A Pen Cap
B Sliding Sleeve
C Needle Hider
D Locking Ring
E Pen Needle
F Rubber Membrane| G Pre-assembled Cartridge

H Plunger Rod
I Sliding Button
J Dose Memory Lid
K Dose Display Window
L Dose Knob
---|---

*parts to get from your pharmacy

Set the dose memory

**SurePal 15 features a dose memory function, which supports you in dialing the correct dose as prescribed by your doctor.
**
Preset the dose before you use your SurePal 15 for the first time.
If your doctor prescribes a new dose, change the dose memory.
To set the dose memory on your SurePal 15, follow the instructions below.

SANDOZ 46302910 SurePal 15 GB Booket - Set the dose
memory 1.1 Open the dose memory lid.
You can now access the dose setting wheel. Odd numbers are not shown but indicated by a dotted line “…..”.SANDOZ 46302910 SurePal 15 GB Booket -
Set the dose memory 2 1.2 Turn the white dose setting wheel until the exact dose prescribed by your doctor is displayed and lines up with the lock symbol next to the dose memory window.
Note: Do not turn the dose knob, which is found on the end of the SurePal 15.
1.3 Close the dose memory lid. The dose is now pre-set and locked.
Attention!
Make sure that the dose memory lid is securely closed. Otherwise, the pre-set dose could be changed accidentally.

Attach the cartridge

Attention!
The pre-assembled cartridge should be removed from the refrigerator 30 minutes before use so that the solution inside can warm up to room temperature.
An injection will hurt more if the solution that you’re injecting is too cold.SANDOZ 46302910 SurePal 15 GB Booket - Attach the
cartridge 2.1 Remove the pen cap without turning it.SANDOZ 46302910
SurePal 15 GB Booket - Attach the cartridge 2 2.2 Unscrew the locking ring and put the SurePal 15 aside.  SANDOZ 46302910 SurePal 15 GB Booket - Attach the cartridge
32.3 Insert the cartridge, narrow end first, into the locking ring.SANDOZ 46302910 SurePal 15 GB Booket - Attach
the cartridge 4 2.4 While turning the cartridge slightly, pull it into the locking ring until you hear a click.SANDOZ 46302910 SurePal 15 GB Booket -
Attach the cartridge 5 2.5 Screw the cartridge and locking ring onto the SurePal 15.

Prepare the cartridge

Wash your hands.
Make sure you have the following items:
– A new pen needle
– Alcohol wipe
– A new pre-assembled cartridge if your SurePal 15 contains less than a complete dose
– A leak-proof, puncture-resistant “sharps container” designed specifically for the safe disposal of used **needles![SANDOZ 46302910 SurePal 15 GB Booket

  • Prepare the cartridge](https://manuals.plus/wp- content/uploads/2023/12/SANDOZ-46302910-SurePal-15-GB-Booket-Prepare-the- cartridge.jpg) 3.1 Make sure that the semi-circle on the locking ring exactly lines up with the dot on the SurePal ™** 15.SANDOZ 46302910
SurePal 15 GB Booket - Prepare the cartridge 2

3.2 Wipe the grey tip of the preassembled cartridge with the alcohol wipe.SANDOZ 46302910 SurePal 15 GB Booket - Prepare the cartridge
3 3.3 Remove the paper seal from the pen needle. SANDOZ 46302910 SurePal 15 GB Booket - Prepare the cartridge
43.4 Screw the pen needle onto the pre-assembled cartridge.SANDOZ 46302910 SurePal 15 GB Booket - Prepare the
cartridge 5 3.5 Pull the outer cap (A) off the needle and set it aside.
Do not remove the inner needle cap (B) yet.

Give the injection

4.1 Make sure the dose memory has been set (page 10).SANDOZ 46302910
SurePal 15 GB Booket - Give the injection 4.2 Position your trigger finger on the housing lid when holding the SurePal 15. Then gently turn the dose knob to the right until you feel a resistance.
4.3 Check the dose display window.
The dose prescribed by the doctor should be displayed here.
Note: If the pre-set dose is not displayed, unscrew the pre-assembled cartridge and locking ring.
Then push down on the sliding button until “0” is displayed in the dose display window. Then pre-set the prescribed dose correctly as described on page 10 of this guide.
4.4 Select an injection site, as recommended by your doctor (e.g. thigh or belly).
Note: Consider rotating the injection site from time to time as recommended by your doctor.
4.5 Disinfect the injection site and a small surrounding area.
Optional: With needle hider
If you don’t want to see the pen needle while giving the injection, attach the needle hider.SANDOZ 46302910 SurePal 15 GB Booket - With needle
hiderSANDOZ 46302910 SurePal 15 GB Booket - With needle hider
2 4.6 Remove the inner needle cap.SANDOZ
46302910 SurePal 15 GB Booket - With needle hider 3Pull the sliding sleeve of the needle hider (A) in a little bit so that you can remove the inner needle cap (B). See Figure 4.6b 4.6c
4.7 Discard the inner needle cap.
Attention!
After you remove the inner needle cap, do not set the SurePal 15 down and make sure that the needle does not touch anything.
Take care not to unintentionally prick yourself on the exposed needle.SANDOZ 46302910 SurePal 15 GB Booket - With needle hider
4 4.8 Pinch a fold of skin at the injection site with one hand.
4.9 Hold the SurePal 15 upright and insert the pen needle into the fold of the skin.
Note: If using the optional needle hider, insert the SurePal 15 into the fold of skin until the bottom (moveable) part is pushed all the way in. This will ensure that the needle is properly inserted.SANDOZ 46302910
SurePal 15 GB Booket - With needle hider 5

4.10 Push the sliding button down and hold it in this position. The dose knob will automatically turn until it stops.
Note: Once you push the sliding button down, the solution for injection is automatically injected. If you need to stop the injection, just release the sliding button.
You can continue the injection by pushing the sliding button down again.SANDOZ 46302910 SurePal 15 GB Booket - With needle hider
6 4.11 Hold the needle in for 10 seconds after the dose knob stops turning. The drug is injected when “0” appears in the dose display window.
4.12 Remove the pen needle from the fold of skin. You may observe some dripping from the pen needle.
This is normal.
Note: If the dose display window does not show “0” you did not receive your complete dose. You will have to give two injections to get the complete prescribed dose.
See page 27 “Inject the remaining dose”.
The first injection will stop when the cartridge is empty and the dose display window will show how much more must be injected to complete the dose. See page 27 “Inject the remaining dose”.

Prepare for storage

SANDOZ 46302910 SurePal 15 GB Booket - Prepare for
storage 5.1 Carefully take off the needle hider.SANDOZ 46302910
SurePal 15 GB Booket - Prepare for storage 2 5.2 Carefully attach the outer needle cap.
Attention!
Do not try to re-attach the inner needle cap. You could puncture yourself and possibly transmit germs.SANDOZ 46302910 SurePal 15 GB Booket - Prepare for
storage 3 5.3 Immediately unscrew the pen needle while holding the locking ring firmly.
5.4 Dispose of the pen needle in a leak-proof, puncture-resistant “sharps container” designed specifically for the safe disposal of used needles.SANDOZ 46302910 SurePal 15 GB Booket - Prepare for storage
4 5.5 Re-attach the pen cap.
Attention!
The SurePal 15 must not be stored with a pen needle attached.
If the SurePal   15 is stored with a pen needle attached, air can get into the pre-assembled cartridge and the solution for injection could leak out.
5.6 Place the SurePal 15 in its case and store it in the refrigerator with the cartridge still attached.
Attention!
Once you have inserted a cartridge in the SurePal 15, it must be stored in a refrigerator at a temperature of 2–8°C (36–46°F).
Make sure that the cartridge does not freeze. If it does, you should not use it any more. The contents of the pre-assembled cartridge must be used within 4 weeks (28 days) of the first use.

Exchange the cartridge

Exchange an empty cartridge

  1. Attach outer needle cap.

  2. Unscrew the pen needle and dispose of it in a “sharps container” page 24.SANDOZ 46302910 SurePal 15 GB Booket - Prepare for storage 5

  3. Unscrew the locking ring with the pre-assembled cartridge from the SurePal 15.

  4. Remove the pre-assembled cartridge from the locking ring.

  5. Dispose of the pre-assembled car tridge in the household trash.
    Attach a new cartridge

  6. Slide the new pre-assembled car tridge into the locking ring.

  7. Pull the pre-assembled cartridge into the locking ring until you hear a click.

  8. Screw the locking ring and attached pre-assembled cartridge onto the SurePal 15.

  9. Make sure that the semi-circle on the locking ring exactly lines up with the dot on the SurePal 15.

Inject the remaining dose

If the dose knob stopped turning because of an empty pre-assembled cartridge, inject the remaining dose as follows:

  1. Remove the empty pre-assembled cartridge page 25.
    Note: Be careful not to trigger the sliding button as soon as you have removed the pre-assembled cartridge. Otherwise the remaining dose will be deleted.

  2. Attach a new pre-assembled car tridge page 26.
    The SurePal 15 will automatically keep track of how much of the dose still needs to be given to make a complete dose.

  3. Attach a new pen needle.

  4. Continue with the injection using the new pre-assembled cartridge page 17.
    Note: Do not change the setting on the dose knob because it is still set to the amount required to complete the dose.

Storage and transport

Storage
Always store the SurePal 15 in its case, with the pen cap attached.
Do not store the SurePal 15 with the needle attached. Store the SurePal 15 and the attached pre-assembled cartridge in the refriger ator at a temperature of 2–8°C (36–46°F). Make sure that the cartridge does not freeze. If it does freeze, you should not use it  any more.

Storage period
The contents of the pre-assembled cartridge must be used within 4 weeks (28 days) of the first use.
After 4 weeks the pre-assembled cartridge should be thrown away, even if it has not been used completely.
Transport and travel
The SurePal 15 with the attached pre-assembled cartridge should be transported in a cooler bag to make sure that it stays at the proper temperature without freezing. If it freezes, it should not be used again.

Care and disposal

Care
The SurePal 15 is a medical device and should be handled with care.
**Protect the SurePal 15 against light, dust, and contaminants.
**
Clean the SurePal 15 and the needle hider with a dry, lint-free cloth. Do not use any liquids or cleaning agents.

Needle disposal
Collect the pen needles in a leakproof, puncture-resistant “sharps container” designed specifically for the safe disposal of used needles.
“Sharps containers” can be purchased at most pharmacies and other select retailers.
Keep the “sharps container” out of reach of children.
Dispose of empty pre-assembled car tridges with your household waste.

Troubleshooting

The dose knob is hard to turn: Liquid may have leaked into the SurePal 15. If so, exchange your SurePal 15 for another one.
In case the knob stops unexpectedly, check if the cartridge is empty: If it is not empty, please replace the needle and continue injection.
The pen needle is still dripping when the injection is finished: Next time you give an injection, leave the needle in the skin for about 10 seconds longer. See page 17.
The pre-assembled cartridge doesn‘t fit: You may be trying to insert an incompatible pre-assembled cartridge. The SurePal 15 is only compatible with the pre-assembled cartridge listed on page 5.
The pre-assembled cartridge is damaged: Never use a pre-assembled cartridge that is damaged in any way (e.g. broken glass)! Pre-assembled cartridges should be handled with care at all times.
The dose display window of the SurePal 15 does not show the preset dose: The dose memory lid may not be closed properly. If you can’t get the dose memory lid to close securely or the dose displayed is incorrect for some other reason, stop using your SurePal  15 and exchange it for a new one.

Warranty

The SurePal 15 comes with a 2-year warranty. After 2 years of use, return to the place where you obtained your SurePal 15 and exchange it for a new one.
If you should discover any material or manufacturing defects in your SurePal 15 within the warranty period, you will receive a replacement at no charge.
This warranty shall not apply if the SurePal 15 is not used in accordance with the instructions for use or if the defect occurs as the result of negligence, misuse, or accidental damage.
0123
Rev. 2020-07
Manufacturer
Sandoz GmbH
Biochemiestrasse 10
A-6250 Kundl
Austria
+43 (0)5338 200
www.sandoz.com
Distributor
Sandoz Limited
Park View, Riverside Way
Watchmoor Park
Camberley, Surrey
GU15 3YL
United Kingdom
The SurePal 15 complies with the accuracy requirements of the International Standard ISO11608-1.
46302910SANDOZ Logo