Overview

The RKP series rackmount computers are powered by an Intel Atom®, 11th Gen Intel® Celeron®, or Intel® Core™ i5/i7 processor. The computers come with a rich set of interface options including up to 10 software-selectable RS-232/422/485 serial ports, up to 12 Gigabit Ethernet ports, and 8 digital inputs and 8 digital outputs. The communication interfaces are located on the front and rear sides of the product, enabling easy access and expansion for industrial applications.
Two hand-rotated 2.5” SSD storages and an outer replaceable RTC battery design deliver a reliable, durable, and versatile platform for a more user-friendly option.
Designed as 1U standard form factor fanless rackmount computers with an operating temperature range of -30 to 60°C and a build-in TPM 2.0 module, the RKP computers are ideal as reliable and secure computing platforms for industrial applications in extreme operating environments.

Package Checklist

Each basic system model is shipped with the following standard items.
Before installing the RKP series, verify that the package contains the following items:

  • RKP rackmount computer (mounting ears attached)
  • 2-pin terminal block for DC power
  • 2 10-pin terminal blocks for DI/DO
  • Pack of 8 screws for the storage trays
  • Quick Installation Guide
  • Warranty card

NOTE Please notify your sales representative if any of the above items are missing or damaged.

Hardware Overview

Front View
RKP-A110-E2-T/RKP-A110-E4-T Models

MOXA RKP Series PC Fanless Rack Mount - Front View RKP-A110-E2-8L-T/RKP-A110-E4-8L-T Models

MOXA RKP Series PC Fanless Rack Mount - A110-E4-8L-T
Models RKP-A110-E2-8C-T/RKP-A110-E4-8C-T Models

MOXA RKP Series PC Fanless Rack Mount - A110-E4-8C-T
Models RKP-A110-E2-2L4C-T/RKP-A110-E4-2L4C-T Models

MOXA RKP Series PC Fanless Rack Mount - RKP-A110 RKP-C110-C1-T/RKP-C110-C5-T/RKP-C110-C7-T Models

MOXA RKP Series PC Fanless Rack Mount - RKP-C110 RKP-C110-C1-8L-T/RKP-C110-C5-8L-T/RKP-C110-C7-8L-T Models

MOXA RKP Series PC Fanless Rack Mount - RKP-C110-C1-8L RKP-C110-C1-8C-T/RKP-C110-C5-8C-T/RKP-C110-C7-8C-T Models

MOXA RKP Series PC Fanless Rack Mount - RKP-C110-C1 RKP-C110-C1-2L4C-T/RKP-C110-C5-2L4C-T/RKP-C110-C7-2L4C-T Models

MOXA RKP Series PC Fanless Rack Mount - RKP-C110-C12

Rear View

RKP-A110 Series

MOXA RKP Series PC Fanless Rack Mount - Rear View RKP-C110 Series

MOXA RKP Series PC Fanless Rack Mount - RKP-C110
Series

Dimensions

RKP-A110/RKP-C110 Series

MOXA RKP Series PC Fanless Rack Mount - Dimensions

LED Indicators

The following table describes the function of the LED indicators located on the front panel of the RKP computers.

LED Name Status Function
Power Green Power is ON
OFF No power input or any other power error

Ethernet
(10/100
Mbps)
(1000 Mbps)| Green| Steady ON: 10/100 Mbps Ethernet link Blinking: Data is being transmitted or received
Yellow| Steady ON: 1000 Mbps Ethernet link Blinking: Data is being transmitted or received
OFF| No Ethernet connection
Storage (2.5″ SSD)| Yellow| Blinking: Data is being accessed from the SSD drive
OFF| Data is not being accessed from the SSD drive

Installing the RKP Computer

The RKP computers come preinstalled with two rack-mounting ears. To mount the computer on to a rack, do the following:

Step 1 : If the mounting ears are not installed, use four screws each to attach the mounting ears on both sides of the computer.

MOXA RKP Series PC Fanless Rack Mount - mounting Step 2:
Place the RKP on a rack and use another four screws to secure the rack-mount ears to the rack.

MOXA RKP Series PC Fanless Rack Mount - RKP

The second set of four screws needs to be purchased separately. Refer to the figure on the right for the specifications.

MOXA RKP Series PC Fanless Rack Mount - screws

NOTE This computer is intended to be installed only in an area with restricted access. In addition, for safety reasons, the computer should be installed and handled only by qualified and experienced professionals.

Connecting the Power

The RKP computers are provided with 2-pin power input connectors in a terminal block on the front panel. Insert the power-cord wires into the connectors and tighten them to secure the wires in place. Plug in the power cable to a power source. The power LED will light up to indicate that power is being supplied to the computer. It should take about 30 to 60 seconds for the operating system to complete the boot-up process.

Pin Definition
1 V+
2 V-

ATTENTION
This product is intended to be supplied by a Listed Power Supply with output marked LPS and rated to deliver 12 VDC at a maximum of 5.4 A, or 24 VDC at a maximum of 2.6 A, and minimum Tma=60˚C. If you need assistance with purchasing a power adapter, contact the Moxa technical support team.

ATTENTION
Before connecting the RKP computer to the DC power inputs, ensure that the DC power source voltage is stable.

  • The wiring for the input terminal block shall be installed by qualified and experienced professionals.
  • Wire Type: Cu, FW2
  • Use 18-12 AWG wire size and a torque value of 0.5 Nm.
  • Use only one conductor in a clamping point between the DC power source and the power input.

NOTE If using Class I adapter, the power cord adapter should be connected to a socket outlet with an earthing connection or the power cord and adapter must comply with Class II construction.

NOTE For surge protection, connect the grounding connector located below the power connector with the earth (ground) or a metal surface.
An 18 AWG cable size conductor must be used when the connection to the external grounding screw is utilized. The heat sink is grounded to the chassis by an internal screw.

Warning

Connecting Displays

The RKP computer comes with an HDMI connector and a VGA connector located on the front panel for connecting audio or video devices.

NOTE Use HDMI-certified cables for a reliable audio or video connection.

Communication Connections

Ethernet Ports
The 10/100/1000 Mbps Ethernet ports use RJ45 connectors. The pin assignments are shown below:

Pin1 10/100 Mbps 1000 Mbps
2 ETx+ TRD(0)+
3 ETx- TRD(0)-
4 ERx+ TRD(1)+
5 TRD(2)+
6 TRD(2)-
7 ERx- TRD(1)-
8 TRD(3)+
TRD(3)-

NOTE For reliable Ethernet connections, we recommend enabling the ports in standard temperatures and keeping them enabled in high/low temperature environment.

Serial Ports

The serial ports use DB9 connectors. Each port can be configured by software as a RS-232, RS-422, or RS-485 port. The pin assignments are shown below:

Pin| RS-232| RS-422| RS-485
(4-wire)| RS-485
(2-wire)
---|---|---|---|---
1| DCD| TxDA(-)| TxDA(-)| –
2| RxD| TxDB(+)| TxDB(+)| –
3| TxD| RxDB(+| RxDB(+)| DataB(+)
4| DTR| RxDA(-)| RxDA(-)| DataA(-)
5| GND| GND| GND| GND
6| DSR| –| –| –
7| RTS| –| –| –
8| CTS| –| –| –

USB Hosts
Three USB 3.0 Type-A connectors are located on the front panel. The ports support keyboard and mouse devices and can also be used to connect a flash disk for storing large amounts of data.
Digital Inputs/Digital Outputs
The RKP computer comes with four digital inputs and four digital outputs in a terminal block. Refer to the following figures for the pin definitions and the current ratings.

Digital Inputs
Dry Contact:
Logic 0: Close toGround
Logic 1: Open
Voltage: 0 to 24 VDD| Digital Outputs
Current Rating: 200 mA per channel
Voltage:  0 to 24 VDC
---|---

For the wiring method, refer to the following diagram:

For additional details, refer to the RKP Series Hardware User Manual.

Installing a Storage Drive

The RKP computer is provided with two storage slots on the rear panel for storage expansion.

MOXA RKP Series PC Fanless Rack Mount - Storage Drive

To install an SSD drive, do the following:

  1. Unfasten the two screws on the storage slot.MOXA RKP Series PC Fanless Rack Mount - SSD drive
  2. Pull out the storage tray and layout four screws from the pouch included in the product package.
  3. Place the storage drive on the tray.
  4. Reverse the storage tray andfasten four screws to secure the storage drive to the tray.
  5. Insert the storage tray into the slot and fasten secure the tray in place with two screws.MOXA RKP Series PC Fanless Rack Mount - fasten secure
  6. Use the same method to install a storage drive in the other slot. 

Replacing the Battery

The RKP computer comes with one slot for a battery on the bottom panel of the computer. A lithium battery (3 V / 200 mAh) is preinstalled in the slot.
To replace the battery, do the following:

  1. Unfasten the two screws on the battery cover.

  2. Take off the cover.
    The battery is attached to the slot cover as indicated in the image.

  3. Unplug the connector of the battery-cover assembly from the internal wire of the slot.

  4. Remove the two screws on the metal plate attached to the battery holder.MOXA RKP Series PC Fanless Rack Mount - battery2

  5. Place a new battery in the battery holder, replace the metal plate, and fasten the two screws on to the frame to secure the battery.

  6. Plug in the connector of the battery-cover assembly to the internal wire of the slot.

  7. Place the battery holder back in the slot and secure it by fastening the two screws on the cover.

Warning

  • Be sure to use the correct type of battery. Incorrect battery may cause system damage. Contact Moxa’s technical support staff for assistance, if necessary.
  • To reduce the risk of fire or burns, do not disassemble, crush, or puncture the battery; do not dispose of in fire or water and do not short external contacts.

RKP-A110-E2-T
RKP-A110-E2-T-Win10
RKP-A110-E4-T
RKP-A110-E4-T-Win10
RKP-A110-E2-8L-T
RKP-A110-E4-8L-T
RKP-A110-E2-8C-T
RKP-A110-E4-8C-T
RKP-A110-E2-2L4C-T
RKP-A110-E4-2L4C-T
RKP-A110-T
RKP-A110-L-T
RKP-A110-C-T

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals