SAFETY INSTRUCTIONS
Please read this installation and user guide carefully before installing and using the product, paying special attention to the safety instructions.
Save these instructions for later use or for the party who may take over the product after you. Disconnect the product from the power supply prior to cleaning or maintenance.
- Diversion of exhaust air must be carried out in accordance with instructions issued by the appropriate authority.
- Exhaust air may not be directed into flues that are used for fumes from items such as gas, wood or oil-burning stoves or fireplaces.
- The distance between the stove and the product must be at least 50cm. For gas hobs, the distance should be increased to 65 cm. Adjust accordingly if the gas hobs manufacturer recommends a higher mounting height.
- For safety reasons, installation and replacement of cables or other types of connectors should only be carried out by a qualified professional.
- Flambéing underneath the product is not permitted.
- If the product is to be used at the same time as products that use energy sources other than electricity, i.e., gas hobs, gas, wood or oil-burning stoves or fireplaces, etc, the room must have an adequate supply of air.
- The product may be used by children from 8 years of age and persons with mental, sensory or physical impairment, or a lack of experience and knowledge, provided they are given information about how the product is to be used.
- Children should not be allowed to play with the product. Children must not undertake cleaning or maintenance of the product unsupervised.
- Accessible parts of the product may become hot when food is being prepared.
- A fire is more likely to spread if the product is not cleaned as frequently as indicated.
INSTALLATION
Cooker hood for wall mounting. The cookerhood has a transformer for
controlling the central fan and the option of wet room ventilation. The cooker
hood is equipped with electronic control, a motorised damper,
LED lighting and a metal mesh filter. Installation, användning, skötsel,
underhåll mmframgår av denna anvisning.
TECHNICAL INFORMATION
Measurements | see Fig. 1 |
---|---|
Electrical installation | 230 V ~ earthed |
Max. connection output | External motor – 370 W at 230 V |
Reheated – 2000 W at 230 V
Lighting| LED 2 x 2 W
Output voltage from transformer| 80, 100, 120, 140, 160 and 180 V
Connected voltage on delivery| 80 V at speed 1, 120 V at speed 2 and 230 V at
speed 3
INSTALLATION
Fixing parts, screws for mounting, etc. are supplied with the cooker hood.
Electrical installation
The connection must be secured and the cooker hood must be preceded by an omni
polar switch.
The junction box or wall socket should be positioned as shown in the
measurements, Fig. 3.
When installing with an extended upper chimney part, take this into account
when positioning sockets. The junction box or wall socket must be accessible
after installation is complete.
Installation Components
D | 2 pcs | Brackets for the upper chimney section |
---|---|---|
E | 7 pcs | Wall plugs 5.5 x 35 |
F | 7 pcs | Screws 4,5 x 39 TORX T25 |
G | 2 pcs | Screws 2,9 x 9,5 |
H | 2 pcs | Screws 3,5 x 6,5 |
J | 1 pcs | Full seal damper |
Installation of wall mounts, marking the wall
Attention!
For total height, distance between the bottom of the cooker hood and the top of the chimney, see see dimensions drawing Fig. 1 When installing with an extended upper chimney section, see dimensions for this.
Mark a centre line A above the stove where the cooker hood is to be mounted.
Draw a horizontal reference line B above the stove, Fig. 3.
Place the upper bracket D for the chimney on the wall, as shown in Fig. 3.
Mark the bracket’s screw holes on the wall.
Place the lower bracket D for the chimney on the wall, as shown in Fig. 3,
below the upper bracket, and mark where the screw holes should go on the wall.
Mark the screw holes for the mounting of the cooker hood, C, on the wall, as shown in Fig. 3.
Drill Ø 3,5 mm holes in the centre of all the marked points.
Fasten the consoles to the chimney using the screws F.
If the supplied plugs are to be used, drill Ø 5,5 mm holes. Drill the hole 5 mm deeper than the length of the plug. Place wall plugs E in the holes. Check that the screws and plugs used are intended for the wall material (red plastic plug is for attachment in concrete, brick and natural stone).
Assembly
Remove grease filter Fig. 12.
Prior to mounting, screw two screws F into the pre-drilled holes, Fig. 4.
Hang the cooker hood and adjust it horizontally Secure it in place with a
screw F. Reinstall the grease filter.
Connection to exhaust flue
Connect the cooker hood with a pipe or tubing Ø160 mm. If the connection is Ø125 mm a reducing coupling sleeve must be used.
Attention!
When using connecting tubing, the tubing must be stretched and installed
directly adjacent to the connection, Fig. 5.
Mounting the chimney
Chimney, upper section
Gently bend the two sides of the upper chimney section outwards and hook them on the brackets D. Make sure they are secure.
Attach the sides to the upper brackets using screws G ( 2,9 x 9,5 mm), Fig. 6.
Chimney, lower section
Gently bend the two sides of the lower chimney section outwards and secure them between the upper chimney section and the wall. Make sure they are properly in position.
Attach the sides of the lower chimneys section to the cooker hood using screws H (3,5 x 8 mm), Fig. 6.
Removal of protective plastic
Remove all protective plastic from the filter and any other parts of the product.
ADJUSTING AIR FLOW
CHANGING VOLTAGE IN THE TRANSFORMER
Output power for speed 2 may be changed to 100 V by reprogramming via the switch. (Contact customer services.).
SETTING THE DAMPER
The air flow is adjusted with the aid of the damper. The damper can be accessed for adjustment by removing the filter.
Measurement outlet
The measurement pressure Pm is measured in the measurement outlet, Fig. 7A. With the aid of the measurement pressure Pm and the position of the damper, the volume of air can be read off in the adjustment diagram, where F1-F6 are forced ventilation and G1-G6 are basic ventilation.
If the volume of air has to be altered, read off a new damper setting from the diagram and then adjust the position of the damper according to the following description.
Open the damper hatch, Fig. 8B.
Attention!
Handle the damper with care!
Remove the forcing hatch, Fig. 9C, by lifting it from the locking tags, Fig. 9D.
Attention!
Handle the forcing hatch with care, making sure it is not bent. Move the hatch to the desired position. Markings for the position of the forcing hatch, F1–F6, correspond with the values in the diagram Forced ventilation, see Fig. 14 .
BASIC VENTILATION GROUND VALVE ASSY
Adjustment chart
Pressure in measuring socket
-
LPW = The A-weighted sound power level is relatively 1 pw
Relative A-weighted sound power level 1 pw -
LPA = The A-waved sound pressure level at 10 m2 Sabin
A-wide sound pressure knife wood 10 m2 Sabin -
A-brothers found veal relative to 1 pw
A- weighted sound balance for 1 pw
K factor | F1 | F2 | F3 | F4 | F5 | F6 |
---|---|---|---|---|---|---|
2,36 | 3,02 | 3,78 | 4,96 | 6,08 | 7,76 |
Press the forcing hatch into the lock, ensuring that it is properly secured.
Measure the pressure Pm and check that the desired forcing flow is achieved.
(See diagram, Fig.14)
Attention!
Handle the damper with care.
The markings for the position of the damper hatch, G1–G6, correspond with the values in the diagram Basic ventilation, see Fig. 15.
K factor | G1 | G2 | G3 | G4 | G5 | G6 |
---|---|---|---|---|---|---|
0,70 | 1,04 | 1,20 | 1,51 | 2,04 | 2,90 |
FORCING FLOW FORCED VENTILATION
Dimension diagram
Actual pressure in channel
K-factor | G1 | G2 | G3 | G4 | G5 | G6 |
---|---|---|---|---|---|---|
0,68 | 0,98 | 1,27 | 1,57 | 2,14 | 3,00 |
Adjusting basic ventilation
Adjust the basic ventilation with the damper hatch closed. Undo the screws,
Fig. 10E.
Move the damper hatch, Fig. 10F, to the desired position.
Adjustment chart
Pressure in the measuring connector.
Lock the damper hatch in place with the screws, Fig. 10E.
INSTRUCTIONS FOR USE
FUNCTION SWITCH
The central fan always operates in standard mode for general and sanitary ventilation.
- A. Lighting.
- B. Open/close damper.
- C. Speed 1 on fan motor.
- D. Speed 2 on fan motor.
- E. Speed 3 on fan motor.
When cooking, open the damper with button. Fan motor speed is controlled via
buttons C to E.
With a closed damper, sanitary ventilation can be increased by pressing
buttons D or E.
The damper is timer-controlled and closes automatically after 60 minutes or by
pressing button B once more.
The central fan returns to standard mode by pressing button D.
It is a good idea to open the damper a short while before and after cooking,
in order to avoid the spread of odours in the room.
CARE AND MAINTENANCE
Attention!
In order to ensure operation, quality and safety after servicing and
maintenance, use only original parts.
Cleaning
The cooker hood should be cleaned with a damp cloth and washing-up liquid. With normal usage, the filters must be cleaned at least every other month. Clean more often after intensive use.
Remove the grease filters by opening the snap retainer, Fig. 12 Handle the filters carefully, taking care not to bend them. Soak the filter in a solution of warm water and washing-up liquid. The filter can also be washed in a dishwasher.
Refit the grease filters after cleaning, making sure they snap firmly into
place.
The inside of the cooker hood and the damper must be cleaned at least twice a
year.
Wipe with a damp cloth and washing-up liquid. The damper is easiest to clean
when it is open.
REPLACEMENT OF LED LIGHTING AND LED DRIVER
Attention!
The replacement of the LED lighting and LED driver must be carried out by an authorised professional. Contact the service organization.
The lighting and driver must be replaced with an equivalent special light
fixture and driver from the manufacturer or its service agent.
SERVICING AND WARRANTY
Check that the fuse is intact. Go through all the functions to check what is
not working. Contact Franke Service
Tel. +46 (0)912-40 500
www.franke.se/service
They can help you fix the problem or refer you to the nearest service agent
for fast and effective service.
The product is covered by the relevant APPLIA provisions.
PACKAGING AND PRODUCT RECYCLING
The packaging should be deposited at your nearest recycling point.
The symbol means that the product must not be treated as household waste. It
should instead be taken to a collection point for the recycling of electrical
and electronic components. By ensuring that the product is dealt with in the
correct manner, you are helping to prevent the adverse environmental and
health effects that could arise if the product was disposed of as regular
waste. For further information on recycling, contact your local authority or
waste disposal service, or the store where you purchased your product.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>