Product Usage Instructions

Safety Instructions
The following symbols are safety warning signs. To avoid the risk of injuries and hazardous situations, it is important to follow all safety regulations and symbols mentioned in this document.

Warning!
The danger of electric shock – High voltage!

Caution:
Rotating parts!

General Safety Instructions
It is important to observe the following general safety instructions:

  • Read and understand the user manual before using the product.
  • Keep the product away from children and pets.
  • Do not operate the product if it is damaged or shows signs of malfunction.
  • Do not touch rotating parts while the product is in operation.
  • Disconnect the power supply before performing any maintenance or cleaning.

Scope of Application and Working Conditions
The Fan 1500 and Fan 1500 DH are designed for the following purposes and working conditions:

  • Purpose: Provide air circulation and cooling
  • Working Conditions: Suitable for indoor use only. Avoid exposing the product to extreme temperatures, humidity, or direct sunlight.

Frequently Asked Questions (FAQ)

  • Q: Can I use the Fan 1500 outside?
    A: No, the Fan 1500 and Fan 1500 DH are designed for indoor use only.

  • Q: Can I touch the rotating parts while the fan is in operation?
    A: No, it is important to avoid touching the rotating parts while the fan is in operation to prevent injuries.

  • Q: How should I clean the fan?
    A: Before cleaning, make sure to disconnect the power supply. You can clean the fan using a soft cloth or brush to remove any dust or debris on the surface. Avoid using abrasive materials or liquid cleaners.

PRODUCT DESCRIPTION

BOSCH-W125-Bathroom-Extractor-Fan-fig- \(1\)

WARNING

The following safety symbols show important safety information. Follow all safety regulations and the safety symbols shown in the Instructions manual to avoid injury and hazards!

  • Danger!
  • Electrocution hazard: high voltage!
  • Attention: rotating parts!

GENERAL SAFETY PRINCIPLES

Information for the target group
Observe the instructions in the manual. Failure to follow the instructions may result in property damage, personal injury, or even death.

  • Read the installation instructions before proceeding with the installation.
  • Read and retain this manual before using the device.
  • Observe safety principles and warnings.
  • Observe national and regional regulations, technical rules, and guidelines.

Safety of household and similar electrical appliances
To avoid hazards posed by electrical appliances, the following requirements apply per the EN 60335-1 standard:

  • “This product can be used by children at least 8 years old, by people with impaired physical and/or mental abilities, and by people without any experience in or understanding of the operation of the product, if supervised or instructed by a competent adult in the safe use of the product so that they understand the relevant operating risks.”
  • “Children should not play with the appliance. Children should not be allowed to clean or maintain the product without supervision of an adult.”
  • “If the power cord is defective, it must be replaced by the manufacturer, his service department, or a person with similar qualifications to avoid hazards.”

Risk of fatal injury from electric shock!
Touching live electrical parts may result in electric shock.

  • The bathroom extractor fan is designed for permanent indoor connection, for fixed electrical installation, which must be equipped with means/devices for total contact breakage to ensure complete separation under overvoltage conditions of category III according to the regulations for such installation.
  • The bathroom extractor fan is designed for installation at a substantial height, i.e. 2,3 m above the floor. Installation – only by the descriptions and guidelines in this manual, in particular about the required installation position, by inserting the power cord into the housing.
  • Measures shall be taken to prevent gases from escaping from the open smoke duct or other open flame equipment into the room.
  • Unauthorized changes or modifications to the equipment are not permitted.
  • Before installing the equipment, check the load-bearing capacity of the structure to which it is to be mounted, as improper mounting can lead to damage or destruction of the equipment and can pose a risk to persons in the vicinity of the equipment in the following situations.

The appliance may become dangerous if used improperly or if installed by unqualified personnel.

APPLICATION AND OPERATING CONDITIONS

  • Bathroom extractor fans are designed to transport normal or slightly dusty air (particle size <10 μm) of low aggressiveness and humidity in temperate climates according to and within their limits of performance.
  • The appliance is designed only for continuous operation in a building if there is no access to the power supply line.
  • The maximum temperature of the medium handled by the bathroom extractor fan and the maximum ambient temperature is +40°C.
  • The exhaust fan is an IP4 and protection class II device if it is installed by Appendix 1 (Fig. 5) in the wall. The fan is not designed for ceiling installation.BOSCH-W125-Bathroom-Extractor-Fan-fig- \(5\)
  • The bathroom extractor fan must be operated according to its intended use and by the data provided on the rating plate.
  • The bathroom extractor fan must be connected to the building mains (recessed electrical installation) with one of the following power cables: NYM-O 2×1,5 mm2; NYM-O 3×1,5 mm2; NYM-J 3×1,5 mm2, depending on the fan version – see point 6. If a cable with more wires has to be used, e.g. NYM-J 4×1,5mm2, the outer diameter of the cable must not exceed 14mm.BOSCH-W125-Bathroom-Extractor-Fan-fig- \(6\)
  • The bathroom extractor fan cannot be used to circulate air with the following characteristics:
    • viscous contaminants prone to deposition in the bathroom extractor fan,
    • corrosive contaminants which may degrade the bathroom extractor fan,
    • – contaminants from mixtures of flammable substances in the form of gases, vapors, mists, and dust, which in combination with air can create an explosive atmosphere.
  • Motors fitted with ball bearings are designed for a service life of at least 30,000 hours at maximum permissible ambient temperature to enable continuous operation at maximum efficiency.
  • If the user has used an additional controller in the appliance, the controller cannot cause extreme operation of the appliance during frequent switching on and off.
  • The device is not suitable for use above 2000m.

TRANSPORT AND STORAGE

  • Bathroom extractor fans should be stored in their original packaging in a dry place protected from weather conditions.
  • Maintain storage and transport temperatures between -20°C and +40°C.
  • Avoid shocks and impacts. Bathroom extractor fans should be transported in their original packaging.
  • If the storage period is longer than 1 year, it is necessary to check the correct functioning of the motor bearings by manually turning the rotor before installation.
  • Disposal must be carried out properly, in an environmentally sound and legal manner.
  • Damage caused by improper transport, storage or start-up must be demonstrated and is not covered by the warranty.

PRODUCT DATA

Terminal block (standard version, no part index suffix). Models with terminal blocks should be connected according to the wiring diagram in Fig. 2. The bathroom extractor fan is operated by means of a separate switch, which is part of the building electrical installation (not part of the appliance). Humidity sensor and timer (part name suffix “DH”). Models equipped with humidity sensors (hygrostat) and stop delay (timer) should be connected according to the wiring diagram in Fig. 3 or 4. The operation of the bathroom extractor fan will depend on the power supply connection method. When connected as shown in Fig. 4, the bathroom extractor fan starts automatically when the air humidity exceeds the set value. It is switched off when the humidity drops below the set value and after the time of the set stop delay has elapsed since the humidity drops.

If connected according to Fig. 3, in addition to automatic operation, it is possible to manually start the bathroom extractor fan using a light switch or a separate switch for the bathroom extractor fan. If the light or the bathroom extractor fan is off, as in the first case, the appliance will stop after the stop delay time set with the potentiometer has elapsed, provided that the humidity level in the room is below the level preset on the potentiometer. The humidity detection system is the master system. The humidity sensor operating range is 40% to 90% of relative air humidity. The system is additionally equipped with a timer.

The stop delay time can be set with a potentiometer knob on the electronic module of the stop delay timer. The minimum stop delay time is 3 minutes with the potentiometer knob rotated counterclockwise. Turn the potentiometer knob clockwise to set a longer stop delay time accordingly. The maximum stop delay time is 30 minutes. The stop delay time regulation is smooth. The fan stop delay time is counted from the time of switching off the light or a separate switch to which the appliance is connected or from the time of humidity drop set on the humidity sensor potentiometer.

ATTENTION:
When the green diode located in the electronic system is on, it means that the humidity level in the room is higher than the preset on the potentiometer controlling the humidity level adjustment. As long as the diode is on, the fan will not start counting down the stop delay after which the fan is switched off. It will take place only after the humidity level in the room drops and the green diode goes off.

INSTALLATION

The bathroom extractor fan should only be installed, connected to electrical mains and commissioned for use by qualified personnel per applicable laws!

BOSCH-W125-Bathroom-Extractor-Fan-fig- \(8\)

Installation procedure

  • Determine the installation location of the fan.
  • Prepare the power cable. Use NYM-O 2×1,5 mm² or NYM-O 3×1,5 mm² depending on the equipment variant. If NYM-J 3×1,5 mm² or NYM-J 4×1,5 mm² cable is used in the installation, insulate the earth cable.

NOTE: Ensure that the power cable is not live before proceeding.

  • Remove the push-fit hole plugs (9) using a pointed tool.
  • Measure and drill the holes for the fan, the ø6 mm fixing pins (included in the package), and then route the power cable shown in Figure 5.
  • Remove the electrical cover (2) secured with screws (3).
  • Pass the double-insulated electrical cable through the passage (4). The cable should be led in a length that allows connection to the power terminals.

Before fixing the fan: Remove foreign objects from inside the fan; check that the rotor rotates freely by setting it in motion with your hand; ensure there is enough space for the opening of the check valve shutter located at the fan outlet;

It is recommended to connect the exhaust fan to the duct installation using flexible tubes!

  • Place the fan body (5) and the mounting pins into the prepared holes.

  • Secure the fan to the partition by screwing the screws into the fixing plugs, using the mounting holes (6).

  • Insert the mounting hole plugs

  • Remove the outer insulation from the cable, remove the wire insulation to a length of 4 mm.

  • Arrange the cable and connect it according to the connection diagram appropriate for the model being installed.

  • Ensure that the cable conductors are securely attached to the terminals.

  • Check the fan for secure mounting and proper electrical installation.

  • Adjust the parameters:

    • Applies to the DH version:
      Set the time delay value and humidity sensor sensitivity using the key (7) on the potentiometers located on the controller (8).
  • Check the sealing of the connection cable.

    • The connection cable must be protected in such a way that, in the event of flooding, under no circumstances can water reach the live parts.
  • Put on the electrical cover (2) and then screw it in with screws (3).

  • Attach the front panel (1) which acts as protection against touching moving parts.

ATTENTION!

  • Hazard of crushing fingers with the rotating fan rotor!
  • Install the guard against the direct touch of moving parts before starting!

FIRST START OF THE DEVICE

The first start may only take place after all safety precautions have been checked and risks have been eliminated. After the bathroom extractor fan starts, check that it runs steadily and the air is handled efficiently (out of the room and through the exhaust duct to the outside).

  • The bathroom extractor fan may only be used with the front panel, which protects against contact with moving parts.
  • The installer is responsible for compliance with the applicable standards and may be held liable for accidents resulting from the absence of safety devices.

ELECTRICAL CONNECTIONS

  • The electrical connection and start-up may only be carried out by qualified personnel who are qualified to perform electrical work.
  • Always follow the applicable standards, safety regulations and technical requirements specified by the power company!
  • The type of mains system, voltage and frequency must match the data on the rating plate of the bathroom extractor fan.
  • For bathroom extractor fans with stop delay time, the minimum voltage at the T terminal that starts the stop delay countdown or starts the exhaust fan is 130V AC.

DIMENSIONS

The dimensions of the models are listed on the packaging and Figure 6

MAINTENANCE AND CLEANING

Maintenance

  • Observe the safety and OHS regulations during all maintenance work.
  • Before servicing the bathroom extractor fan, disconnect it from the mains and secure it against inadvertent operation!
  • The bathroom extractor fan ventilation ducts must be clear of foreign bodies: hazard of injury by objects blown out at a high speed!
  • Do not attempt any maintenance works when the fan is running.
  • If excessive vibrations are felt or heard, have the product maintenance carried out by a qualified electrician.
  • Depending on the degree of impeller contamination, technical inspections must be carried out at least once every 6 months!
  • Check the rotor for cracks.
  • The manufacturer is not liable for damage caused by improper repair.
  • In the case of appliances with ball bearing motors with “lifetime lubrication”, the motor does not require lubrication.

CLEANING

Electrocution risk by damaged wiring insulation! Before cleaning, completely disconnect the bathroom extractor fan from the mains and secure it against inadvertent operation!

  • Clean the front cover and visible parts of the housing with a damp cloth.
  • Do not use any aggressive solvents!
  • Do not clean with a high-pressure cleaner or strong jets of water!
  • When cleaning, make sure that no water enters the electric motor or terminal box.
  • The grille at the bathroom fan inlet must always be kept clean.

Waste electrical and electronic equipment

  • This symbol means that the product may not be disposed of together with other waste, but must be taken to a collection point for treatment, collection, recycling, and disposal.
  • This symbol refers to countries where electronic scrap legislation is in force, e.g. the “European Directive 2012/19/EC on waste electrical and electronic equipment”. These rules establish a framework for the return and recycling of waste electronic equipment in each country.
  • Since electronic equipment may contain hazardous substances, it must be recycled responsibly so that potential damage to the environment and risks to human health are minimized. In addition, the recycling of electronic scrap contributes to the protection of natural resources.
  • For further information on how to dispose of waste electrical and electronic equipment in an environmentally sound manner, please contact your local authority, the waste disposal company, or the retailer from whom you purchased the product.
  • Find more information here: http://www.weee.bosch-thermotechnology.com/.

Specification

BOSCH-W125-Bathroom-Extractor-Fan-fig- \(7\)

When requesting customer service, please indicate the numbers (E) and (FD) of the product. You will find both numbers on the nameplate on the back of the product. Contact customer service:

BSH Hausgeräte Service GmbH
Factory customer service for household appliances

  • Leopoldstrasse 252, 80807 Munich Repair service, spare parts & accessories,
  • Product information Tel: +49 08921586660
  • E-mail: [email protected].