LYNX Technik AG ORX 5800 3GBit s Quad Fiber Optic to SDI Converter User Manual

June 15, 2024
LYNX Technik AG

LYNX Technik AG ORX 5800 3GBit s Quad Fiber Optic to SDI Converter

LYNX-Technik-AG-ORX-5800-3GBit s-Quad-Fiber-Optic-to-SDI-Converter-
product

Specifications

  • Product Name : ORX 5800
  • Type : 3GBit/s Quad Fiber Optic to SDI Converter
  • Revision : 1.1
  • Date : June 2023
  • Firmware : 620
  • LynxCentraal Control Software : 1.0.0

Product Description

The ORX 5800 is a 3GBit/s Quad Fiber Optic to SDI Converter manufactured by LYNX Technik AG. It is designed to convert video signals from fiber optic cables to SDI format. The converter supports a high data rate of 3GBit/s and is equipped with four fiber optic inputs for quad-link SDI conversion. It is compatible with the LynxCentraal Control Software version 1.0.0, which allows for easy configuration and control of the device.

Reference Manual

ORX 5800
3GBit/s Quad Fiber Optic to SDI Converter
Revision 1.1
June 2023

| This Manual Supports Device Revisions:
---|---
O RX 5800 Firmware| 620
LynxCentraal Control Software| 1.0.0

  • Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical for any purpose, without express written permission of LYNX Technik AG.
  • LYNX Technik AG may have patents, patent applications, trademarks, copyrights or other intellectual property rights covering the subject matter in this document. Except as expressly written by LYNX Technik AG, the furnishing of this document does not give you any license to patents, trademarks, copyrights or other intellectual property of LYNX Technik AG or any of its affiliates.
  • LYNX Technik AG
  • Brunnenweg 3
  • D 64331 Weiterstadt

Germany
www.lynx-technik.com

Warranty

  • LYNX Technik AG warrants that the product will be free from defects in materials and workmanship for a period of three (3) years from the date of shipment. If this product proves defective during the warranty period, LYNX Technik AG at its option will either repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product.
  • In order to obtain service under this warranty, customer must notify LYNX Technik of the defect before expiration of the warranty period and make suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the defective product to the service center designated by LYNX Technik, with shipping charges prepaid. LYNX Technik shall pay for the return of the product to the customer if the shipment is within the country which the LYNX Technik service center is located. Customer shall be responsible for payment of all shipping charges, duties, taxes and any other charges for products returned to any other locations.
  • This warranty shall not apply to any defect, failure, or damage caused by improper use or improper or inadequate maintenance and care. LYNX Technik shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than LYNX Technik representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non LYNX Technik supplies; or d) to service a product which has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty servicing the product.
  • THIS WARRANTY IS GIVEN BY LYNX TECHNIK WITH RESPECT TO THIS PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. LYNX TECHNIK AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. LYNX TECHNIK`S RESPONISIBILITY TO REPAIR AND REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. LYNX TECHNIK AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTIAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER LYNX TECHNIK OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.

Regulatory information

Europe Declaration of Conformity

  • We
    LYNX Technik AG Brunnenweg 3

  • D-64331 Weiterstadt

  • Germany

  • Declare under our sole responsibility that the product

  • TYPE : O RX 5800

To which this declaration relates is in conformity with the following standards (environments E1-E3):

  • EN 55103-1 /1996
  • EN 55103-2 /1996
  • EN 60950-1 /2006

Following the provisions of 89/336/EEC and 73/23/EEC directives.

Weiterstadt, November 2012
Place and date of issue

Winfried Deckelmann

Legal Signature

USA

FCC 47 Part 15

  • This device complies with part 15 of the FCC Rules.

Operation is subject to the following two conditions

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to the part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Getting Started

Most CardModules are installed into the rack frames and system tested in the factory. If this is an upgrade part, or service exchange item then the module is supplied in a padded cardboard carton which includes the CardModule, rear connection plate and mounting screws.

Packaging

The shipping carton and packaging materials provide protection for the module during transit. Please retain the shipping cartons in case subsequent shipping of the product becomes necessary. Do not remove the module from its protective static bag unless observing adequate ESD precautions. Please see below.

ESD Warning

This product is static sensitive. Please use caution and use preventative measures to prevent static discharge or damage could result to module.

Preventing ESD Damage

  • Electrostatic discharge (ESD) damage occurs when electronic assemblies or the components are improperly handled and can result in complete or intermittent failure.
  • Do not handle the module unless using an ESD-preventative wrist strap and ensure that it makes good skin contact. Connect the strap to any solid grounding source such as any exposed metal on the rack chassis or any other unpainted metal surface.

Caution
Periodically check the resistance value of the antistatic strap. The measurement should be between 1 and 10 Megaohms.

Product Description

  • The O RX 5800 is a high quality 3GBit/s / HD / SD SDI quad Fiber Optic to SDI converter primarily for broadcast and professional applications.
  • The O RX 5800 provides four channels of Fiber Optic to SDI conversion with two additional SDI inputs on BNC connectors. The electrical SDI outputs can be mapped individually to any of the optical inputs.
  • Inputs can be relocked, or non-relocked with auto detection of multidate digital video bit rates in relocked mode (270Mbit/s, 1.485 GBit/s or 2.985GBit/s).
  • The O RX 5800 is part of the series 5000 of Card Modules, which offer high quality, modularity and flexibility in a small form factor ideal for applications where space is at a premium.

Functional Diagram

LYNX-Technik-AG-ORX-5800-3GBit s-Quad-Fiber-Optic-to-SDI-
Converter-02

Module Layout

LYNX-Technik-AG-ORX-5800-3GBit s-Quad-Fiber-Optic-to-SDI-
Converter-03

Connections

BNC Video

  • The O RX 5800 uses standard 75 Ohm BNC connectors. We recommend the use of high quality video cable for digital video connections to reduce the risk of errors due to excessive cable attenuation. Max cable lengths the module will support are shown below.
  • SDTV = 250m Belden 8281 (270Mbits/s)
  • HDTV = 140m Belden 1694A (1.485Gbits/s)
  • 3GBit/s = 80m Belden 1694A (2.97Gbits/s)

Note. Due to the compact design of the connection plate it will be necessary to use a connection tool to secure the BNC video connectors.
Unused BNC inputs and BNC outputs should be terminated with 75Ohm to avoid any RF interference

Optical Fiber

  • The O RX 5800 provides LC/PC connectors for single mode fiber cables.
  • Multimode fiber cables can also be used, but this will limit the max. fiber length to approx. 1km (HD-SDI) depending on the used cables and connectors.
  • NOTE : Please take care that surfaces of fiber cables and LC connectors are always protected against scratching and dust if no fiber cables are connected. Dust and/or scratches will lead to high attenuation of the optical power transmitted.

Installation

If this module was supplied as part of a system it is already installed in the rack enclosure. If the module was supplied as a field upgrade please follow the installation procedure below.

NOTE Observe static precautions when handling card. Please see ESD warnings on Page 5.
Each Card Module is supplied with a rear connection panel and two mounting screws. Please follow the following procedure for installation of the card module into the Series 5000 Card Frame.

  1. Select a slot in the Card Frame where the Card Module will be located.
  2. Remove the blank connection panel from the rear of the rack (if fitted)
  3. Install the rear connection panel using the screws supplied. Do not tighten the screws fully.
  4. Slide the Card Module into the card frame and carefully check the Card Module connects to the rear connection plate. The card should fit easily and should not require excessive force to insert, if you feel any resistance, there could be something wrong with the rear connection panel location. Do not try and force the connection, this may damage the connectors. Remove the rear connection panel and check alignment with the Card Module.
  5. Insert and remove the Card Module a few times to ensure correct alignment and then tighten the two screws to secure the rear connection plate.

Settings and Control

The O RX 5800 has an integrated micro-controller, which enables the module to be configured and controlled locally via the dip-switch or from remote when using one of the optional controllers and control software.
Once set, all settings are automatically saved in non-volatile internal memory. (Flash RAM) The module will always recall the settings used prior to power down.

LYNX-Technik-AG-ORX-5800-3GBit s-Quad-Fiber-Optic-to-SDI-
Converter-04

Switch Settings

Below the switch settings for the 8-position dip-switch are defined.

Switch Setting Function
1 ON Enable Local Adjustment
OFF Disable Local Adjustment
2 ON Input 1 reclocked
OFF Input 1 non-reclocked
3 ON Input 2 reclocked
OFF Input 2 non-reclocked
4 ON Input 3 reclocked
OFF Input 3 non-reclocked
5 ON Input 4 reclocked
OFF Input 4 non-reclocked
6 ON Input 1 fed by SFP
OFF Input 1 fed by BNC
7 ON Input 4 fed by SFP
OFF Input 4 fed by BNC
8 ON Slew rate “fast” in non-relocked mode
OFF Slew rate “slow” in non-relocked mode

Switch Function Detail

  1. Dip Switch 1
    This switch is used to enable or disable local adjustments. Set to ON enables the setting of the other dip switches to configure the module. Set to OFF will prevent any switch settings taking effect.
    N o te: The module has a microcontroller and Flash RAM. When this switch 1 is set to ON any configuration settings made on the module with the dip switches will automatically be written into Flash RAM and stored. (see Auto Store) The module will function normally with the switch left in the ON position but it is recommended to set it to OFF to prevent accidental changes to the stored module configuration if the switches are moved.

  2. Dip Switch 2
    This switch configures input 1 be reclocked or non reclocked.
    ON sets reclocked, OFF sets non-reclocked

  3. Dip Switch 3
    This switch configures input 2 to be reclocked or non reclocked.
    ON sets reclocked, OFF sets non-reclocked

  4. Dip Switch 4
    This switch configures input 3 to be reclocked or non reclocked.
    ON sets reclocked, OFF sets non-reclocked

  5. Dip Switch 5
    This switch configures input 4 to be reclocked or non reclocked.
    ON sets reclocked, OFF sets non-reclocked

  6. Dip Switch 6
    This switch configures the source of input 1.
    ON sets input to fiber, OFF sets input to BNC.

  7. Dip Switch 7
    This switch configures the source of input 4.
    ON sets input to fiber, OFF sets input to BNC.

  8. Dip Switch 8
    In non-reclocked mode the slew rate of the SDI outputs is not set automatically. With ON: the slew rate is set to fast (e.g. for HD signals), OFF: the slew rate is set to “slow” (e.g. for SD signals)

Factory Preset Condition

  • The O RX 5800 is delivered programmed and preset for the following mode of operation:
  • Switch 1 ON Local Adjustment Enabled
  • Switch 2 – 5 ON All inputs reclocked
  • Switch 6 – 7 OFF Both switchable inputs are fed by BNC
  • Switch 8 ON Slew rate “fast” in non-reclocked mode
  • If this is the required mode of operation, then no adjustments are necessary.

Auto Store

If no parameters are changed for 10 seconds then the current settings will be written into the flash memory automatically. This can be seen by the channel status LEDS flashing yellow four times.

Alarm/LED Status Indicators

The O RX 5800 module has integral LED indicators, which serve as alarm and status indication for the module. Function is described below.

Channel Condition Indicators
4 status LEDs are provided on the front edge of the module, one for each channel (figure 3).

LED Color Indication
Green Input present
Red Input missing

Alarm Indicator
There is also a single alarm LED on the lower edge of the module (figure 3). This is visible through the card frame front cover and provides a general indication of the module status.

LED Color Indication
Green All Input Signals Present (locked) and both PSUs present
Yellow 1 or more input signal missing or 1 PSU missing
Red No input signal present

LED OFF indicates power is lost, or there is a power supply fault.

Power Indication
There are two LEDs on the lower edge of the module indicating the presence of the two power supply voltages (main power supply and redundant power supply).

LED 1 Indication
Green Power from Main PSU ok
off No power from Main Power Supply
LED 2 Indication
--- ---
Green Power from Redundant PSU ok
off No power from Redundant PSU

Local/remote LED

Local/remote LED Local/remote LED
Local/remote LED Local/remote LED
Local/remote LED Local/remote LED

Control System GUI

  • When using the module in a system with the optional LYNX control system all module settings are available on an intuitive Windows GUI interface.
  • Any settings made using the control system will override any settings made locally. All settings are stored automatically in the module’s Flash RAM.

LYNX-Technik-AG-ORX-5800-3GBit s-Quad-Fiber-Optic-to-SDI-
Converter-05The above screenshot shows the complete GUI of the module. The Device info area contains information about the module including name and firmware revision. If used as part of a larger system (using the LYNX central control system) the module’s position and physical location is displayed above the “locate” button.

Note. The “locate” function is a tool used to quickly identify a module in larger systems. Selecting “locate” will flash the module alarm LED yellow. (This does not affect module operation)

  • The first screen displayed when the module is selected is the Main Tab, this is a graphical representation of the module’s overall function and signal flow.
  • The area at the bottom of the screen is the error log. Any fault condition (or event) will be time stamped and entered the log.
  • There are several “Tabs” along the top of the screen, which splits up the module settings into a number of logical displays. The various GUI screens and primary functions are described below.

Main Tab
This screen is the main interface and is presented first when the module is displayed in the GUI.

  • LYNX-Technik-AG-ORX-5800-3GBit s-Quad-Fiber-Optic-to-SDI-Converter-06The input detection indicates the bit rate (SD-SDI = 270MBit/s, HD-SDI = 1.5 GBit/s; 3G-SDI = 3GBit/s) of a connected signal. If no signal is detected the color of the input detection will turn red and indicate a missing signal.
  • The flex lines at inputs 1 and 4 allow the user to switch between electrical and optical input. (green box)
  • The received power of the optical inputs is indicated in dBm.
  • The four check boxes enable or disable the input reclocking of the respective input.
  • The flex line nodes to the right of the reclocking checkboxes can be freely reassigned to any other node in that group. This also allows a single signal to be reassigned to multiple outputs at the same time. (red box)

Events Tab

The Events Tab is where the module alarming and error notifications are configured for the module.

  • LYNX-Technik-AG-ORX-5800-3GBit s-Quad-Fiber-Optic-to-SDI-Converter-07The GUI has an integrated error log, which is a simple text log file stored in the controller PC. This will record an event and timestamp it. The log can be seen at the bottom of the GUI screen and can be scrolled through using the scrolling bar.

Log in GUI Function

  • Events are selectable and you can choose if you want to record a particular event in the log (or not) or configure it to only record one part of the event. (For example you might want to log when a SDI input was removed but do not want to
  • log when it comes back). The ON/OFF trigger can be configured for each of the available events shown in the list and is set up using the checkboxes provided.

Event Enabled

  • By default all alarm conditions are activated (checked) by de-selecting a specific alarm condition in this column, you are telling the module to ignore this condition completely. It will not color the Alarm LED, log an event in the GUI or
  • send an SNMP trap. This is useful if for example you never have anything connected to input 2 and want the card to ignore this input condition completely, you would simply de-select “SDI Input 2 No Input” and it will be ignored.

SNMP Support

  • If the system is using an RCT 5031 Master Controller and the SNMP option is installed then the “SNMP Trap” columns become available.
  • Here you can configure what events are to be transmitted as an “SNMP trap” into the network. (This has no impact or influence over the internal error log maintained by the LYNX control system)  (Internal LYNX error logging and external SNMP traps can be configured independently).

Note. The simulated event is part of the GUI simulator and allows us to force a particular error condition for testing and demonstration purposes.

Specifications

Video Inputs (BNC)

Signal Type| Serial digital video SMPTE 292M, 259M-C, 424M, DVB-ASI
No. of inputs| 2 x BNC 75 Ohm
Cable Equalization| Up to 250m Belden 8281 (270MBit/s)

Up to 140m Belden 1694A (1.485GBit/S) Up to 80m Belden 1694A (2.97GBit/s)

Return Loss|

  • 15 dB (270MBit/s)

  • 10dB (1.485GBit/s)

Video Inputs (Fiber)
Signal Type| SMPTE 297M-2006
No. of inputs| 4
Connector| LC/PC (single mode dual receivers – duplex connection)
Wavelength| 1260nm – 1620nm
Sensitivity| -16dBm
Max. Overload| -3dBm
Digital Video Outputs (BNC)
Signal Type| Serial digital video SMPTE 259M-C, 292M, 424M, DVB-ASI and SMPTE 310
No. of outputs| 4 x BNC 75 Ohm
Jitter|

  • < 0.2 UI (270MHz)
  • < 0.2 UI (Alignment Jitter); < 1.0 UI (Timing Jitter); (1.485GHz)
  • < 0.3 UI (Alignment Jitter); < 2.0 UI (Timing Jitter); (2.97GHz)

Return Loss| > 15 dB (1.5GBit/s)
Control
Local Controls| Dip Switch
Remote Control| Comprehensive remote control and status monitoring supported when used with a LYNX Controller option
Electrical Specifications
Voltage| 12 VDC
Power| <6W
Safety| IEC 60950/ EN 60950/ VDE 0805
Mechanical
Size| 283mm x 78mm
Weight| CardModule 150g, connector plate 70g
Ambient
Temperature| 5°C to 40°C Maintaining specifications
Humidity| 90% Max non condensing

Service

Parts List

Due to the very dense design and high level of integration there the module is not user serviceable. Please contact LYNX for repairs or to request an exchange unit.

Technical Support

  • If you are experiencing problems, or have questions please contact your local distributor for further assistance.
  • Technical support is also available on our website.
  • Please do not return products to LYNX without an RMA. Please contact your authorized dealer or reseller for more details.
  • More detailed product information and product updates may be available on our web site: www.lynx-technik.com

Contact Information

Please contact your local distributor; this is your local and fastest method for obtaining support and sales information.
LYNX Technik can be contacted directly using the information below.

  • Address LYNX Technik AG
  • Brunnenweg 3
  • D-64331 Weiterstadt

Germany

LYNX Technik manufactures a complete range of high quality modular products for broadcast and Professional markets, please contact your local representative or visit our web site for more product information.

LYNXTechnik AG
Broadcast Television Equipment

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

LYNX Technik AG User Manuals

Related Manuals