Miele PFD 102 Stainless Steel Dishwasher Installation Guide
- June 15, 2024
- Miele
Table of Contents
Miele PFD 102 Stainless Steel Dishwasher
Installation notes
- For safe installation and commissioning of the dishwasher please read the installation plan, the service documentation, the installation sheet, and the operating instructions.
- This installation plan includes the dimensions of the appliance, the technical data, and the requirements to be met on-site for the installation of the dishwasher.
Installation requirements
- This dishwasher must only be installed and commissioned by the Miele Customer Service Department, a Miele authorized dealer or a suitably qualified specialist.
- Installation should only be performed in accordance with valid regulations, relevant standards, and health and safety codes.
Environmental requirements
Condensate can build up in the area surrounding the dishwasher. Any furniture and fittings in the room must therefore be suitable for pur-pose.
Vapor barrier film for built-in applications The vapor barrier film supplied protects the worktop from damage caused by steam when the door is opened. Attach the vapor barrier film above the door, and underneath the worktop.
Electrical connection
All work on the electrical connection must be carried out by the Miele Customer Service Department, an authorized Miele dealer or a qualified electrician.
Plug Connection The dishwasher should be connected to the electricity supply via a socket.
Hard-wired
- If the dishwasher is hard-wired to the power supply, a power switch capable of disconnecting the dishwasher at all poles must be installed on-site. This power switch must have a contact gap of at least 3 mm.
- The socket and the power switch must be accessible after the appliance has been installed. An electrical safety test must be carried out after installation and after any servicing work. The main connection cable must be laid protected from the risk of thermal damage
Residual current device ( RCD) For increased safety, it is recommended to protect the dishwasher with a residual current device (RCD) with a trip current of 30 mA.
Equipotential bonding There is a screw connection point for equipotential bonding at the back of the dishwasher. Equipotential bonding should be carried out if possible on site.
Water connection
The dishwasher must only be connected to fully vented pipework. A brief increase in the water pressure can damage the components of the dishwasher.
Water inlet
- The quality of the incoming water must correspond to the drinking water specification of the country in which the dishwasher is being operated.
- The dishwasher must be connected to the water supply in strict accordance with current local and national water authority regulations. It can be connected to cold or hot water supplies. Connecting the dishwasher to a hot water supply will reduce programme running times. For short programme running times, a water pressure of at least 200 kPa is also required.
- If a stopcock is not available, only a qualified installer may connect the dishwasher to the drinking water supply.
- The stopcock should remain accessible once the dishwasher has been installed so that the water supply can be shut off whenever the appliance is not in use.
Drain
- The dishwasher drain hose should be connected to a separate on-site drainage system for the dishwasher only. If a separate connection is not available, we recommend connecting the hose to a dual-chamber siphon. If the hose is to be fitted directly to the drainage system on-site, use the hose clip supplied with the dishwasher. The on-site connector for the drain hose can be adapted to different hose diameters. If the connector extends more than 30 mm into the drain hose, it must be shortened. Otherwise, the drain hose can become blocked.
- Lay the drain hose so that it does not kink and is not being subjected to pressure or tension.
- If the on-site drain connection is situated lower than the guide path for the lower basket rollers in the open door, a siphoning effect during a program can cause the wash cabinet to empty itself of water.
In this case, lay the drain hose with a bend in it so that its highest point is at least level with the guide path for the lower basket rollers. For AU, NZ the drain should be connected in accordance with AS/NZS 3500.2.
External dispensing
An external dispensing module for liquid cleaning agents can be connected to the back of the dishwasher. The dispensing module is available as an optional accessory and is supplied with installation instructions.
Appliance dimensions and installation dimensions
Appliance dimensions and installation drawings
PFD 102 i
PFD 103 SCi
Appliance type PFD 102 i PFD 103 SCi
Front panel dimensions
Length | [mm] | 500–654 | 540–694 |
---|---|---|---|
Thickness | [mm] | 16–20 | 16–20 |
Weight | [kg] | 4–11 | 4–11 |
Connections
Connections on the back of the appliance
On-site connections
- Electrical connection
- External dispensing, power supply connection
- Equipotential bonding
- Wastewater
- Cold or hot water
- External dispensing, connection for dispensing hose sealed with a blind stopper*
the dispenser connector is supplied with the dispensing module
External dispensing
Max. delivery head | [m] | 1.5 |
---|---|---|
Length of dispenser hose, DOS module to suction lance | [m] | 1.8 |
Length of dispenser hose, back of appliance to DOS module | [m] | 2.8 |
Length of power cable, back of appliance to DOS module | [m] | 2.8 |
Place the container on the floor next to the cleaning machine or in an adjacent cabinet. The container must not be placed on top of or above the cleaning machine.
Technical data
Appliance type PFD 102 I PFD 103 SCi
Dimensions and weights
Height | [mm] | 805 | 845 |
---|---|---|---|
Height adjustment | [mm] | 65 | 65 |
Width | [mm] | 598 | 598 |
Depth | [mm] | 570 | 570 |
Depth with door open | [mm] | 1165 | 1205 |
Max. plinth return | [mm] | 115 | 115 |
Weight | [kg] | 42 | 52 |
Max. floor load | [N] | 1000 | 1000 |
Emission levels | |||
Sound power level | [dB(A) |
re 1 pW]
| 46| 45
Sound pressure level in the workplace| [dB(A)]| 34.1| 32.5
| Technical data
---|---
Electrical connection
Standard electrical connection PFD 102 i
| |
Voltage| | AC 230V
Frequency| [Hz]| 50
Fuse rating| [A]| 32
Plug| | –
Power cable length| [m]| 1.7
Power cable cross-section| [mm2]| 3×4
Heat output| [kW]| 6.1
Total rated load| [kW]| 6.3
Standard electrical connection, Possible voltage variant PFD 102 i
Voltage *| | AC 230V
Frequency| [Hz]| 50
Fuse rating| [A]| 13
Plug| | +
Power cable ** length| [m]| 1.7
Power cable cross-section| [mm2]| 3×1.5
Heat output| [kW]| 1.9
Total rated load| [kW]| 2.1
Program running times are longer with this voltage variant
- Optional accessory
Water inlet
Max. water temperature | [°C] | 60 |
---|---|---|
Max. water hardness | [mmol/l] | 6.5 |
Max. water hardness | [°dH] | 36 |
Water connection pressure | [kPa] | 100 – 1000 |
On-site threaded union (flat seal) | [inches] | 3/4 |
Connection hose length | [m] | 1.5 |
Connection hose extension * | [m] | 1.5 |
- Optional accessory
Drain
Max. water temperature | [°C] | 82 |
---|---|---|
Drain hose length | [m] | 1.5 |
Max. drain hose length | [m] | 4 |
Max. delivery head | [m] | 1 |
Max. transient flow rate | [l/min] | 10 |
Hose inner diameter | [mm] | 22 |
On-site hose sleeve ( x length) | [mm] | 22 x 30 |
Operating conditions | ||
Ambient temperature | [°C] | +5 – +40 |
Relative humidity:
Up to 31 °C, maximum
| [%]|
80
Linear decreasing to 40 °C| [%]| 50
Max. altitude above sea level up to| [m]| 4000
Storage and transportation conditions
Ambient temperature| [°C]| -20 – +60
Relative humidity| [%]| 10–85
Air pressure| [hPa]| 500–1060
Min. site access dimensions including transport pallet
Height| [mm]| 970
Width| [mm]| 670
Depth| [mm]| 670
United Kingdom
- Miele Co. Ltd., Fairacres, Marcham Road
- Abingdon, Oxon, OX14 1TW
- Professional Sales, Tel: 0845 365 6608
- E-mail: professional@miele.co.uk
- Internet: www.miele.co.uk/professional
Australia
- Miele Australia Pty. Ltd.
- ACN 005 635 398, ABN 96 005 635 398
- Level 4, 141 Camberwell Road, Hawthorn East, VIC 3123
- Tel: 1300 731 411
- Internet: www.miele.com.au/professional
- E-mail: professional.sales@miele.com.au
Malaysia
- Miele Sdn Bhd
- Suite 12-2, Level 12
- Menara Sapura Kencana Petroleum
- Solaris Dutamas No. 1, Jalan Dutamas 1
- 50480 Kuala Lumpur, Malaysia
- Phone: +603-6209-0288
- Fax: +603-6205-3768
China Mainland
- Miele Electrical Appliances Co., Ltd.
- 1-3 Floor, No. 82 Shi Men Yi Road
- Jing’ a District, 200040 Shanghai, PRC
- Tel: +86 21 6157 3500, Fax: +86 21 6157 3511
- E-mail: info@miele.cn, Internet: www.miele.cn
United Arab Emirates
- Miele Appliances Ltd.
- Showroom 1, Eiffel 1 Building
- Sheikh Zayed Road, Umm Al Sheif
- P.O. Box 114782 – Dubai
- Tel. +971 4 3044 999, Fax. +971 4 3418 852
- 800-MIELE (64353)
- E-Mail: info@miele.ae
- Website: www.miele.ae