E-Ink MP240B Base Station User Manual

June 15, 2024
E-Ink

E-Ink MP240B Base Station

E-Ink-MP240B-Base-Station-product

Specifications

  • Dimensions: 168 x 168 x 26mm
  • Weight: 276g (approx)
  • Supply Voltage: AC/DC Adapter
  • Base Station Input Voltage: 12VDC, 1.5A

Product Usage Instructions

Unpacking and Checking

In order to facilitate future storage and transportation, please keep the carton and packing materials after opening them. In addition to the MP240B base station, there is also included the following products and accessories:

Item Name Qty Comment
1 MP240B Base Station 1
2 Power Adapter 1
3 Phillips pan head self-tapping screws 4
4 Fitting 1
5 Warranty card 1

Features and Usage

Main Features:

  • Wireless communication with E-ink with easy installation and operation of the tags
  • Large signal coverage radius and supports many tags

Interface:

  • TCP / IP connection with E-ink server
  • 2.45GHz ISM with E-ink tags

LED:

  • Green – Power
  • Blue – System
  • Red – Lan Err
  • Yellow – System Err

The MP240B maximum communication distance is 10-20 meters (Line of Sight and open environment). Compared with base stations of similar nature, the MP240B base station has an attractive appearance, ease of installation, and has good structural design, with an IP20 protective environment rating.

Industrial E-Ink System Overview

An Industrial E-Ink system consists of Industrial E-Ink tags, Industrial E-Ink server, switches, and base stations. The product information in the database will be copied from the host computer to the Industrial E-Ink system application software; then updated contents and other information will be sent via Ethernet to the Base Stations which will then deploy the update throughout the entire store via 2.4GHz wireless transmission.

Each part is described below:

  • E-Ink server: Running E-Ink System
  • Switch: For data exchange between the base station and the server
  • Base Station: For data exchange between the E-Ink and the Hub
  • Industrial E-Ink tags: Updatable display for stored server information

FAQ

Q: What are the dimensions and weight of the MP240B Base Station?

The dimensions of the MP240B Base Station are 168 x 168 x 26mm.
It weighs approximately 276g.

Q: What is the maximum communication distance of the MP240B Base Station?

The maximum communication distance of the MP240B Base Station is 10-20 meters in Line of Sight and open environment.

Q: What is the input voltage for the Base Station?

The Base Station requires a 12VDC, 1.5A input voltage.

Contents

Product Introduction

MP240B is the second-generation base station. It is a new Active RFID fixed base station that implements bidirectional communication between the host system and the Industrial E-ink. . Shanghai Alpha AIOT Technology System Co., Ltd. produces the base station for its Industrial E-ink and other products.

Dimensions and Weight
Dimensions:168 x 168 x26mm Weight: 276g (approx)

Unpacking and Checking
In order to facilitate future storage and transportation, please keep the carton and packing materials after opening them. In addition to the MP24 0B base station, there is also included the following products and accessories:

Item Name Qty Comment
1 MP240B Base Station 1
2 Power Adapter 1
3 Phillips pan head self-tapping screws 4
4 Fitting 1
5 Warranty card 1

Features and Usage

Main Features: Wireless communication with E-ink with easy installation,operation of the tags, large signal coverage radius and supports many tags. Interface: TCP / IP connection with E-ink server, 2.45GHz ISM with E-ink tags. LED: Green- Power, Blue – System, Red – Lan Err, Yellow – System Err.
The MP240B maximum communication distance is 10-20 meters (Line of Sight and open environment).
Compared with base stations of similar nature the MP240B base station has an attractive appearance, ease of installation, and has good structural design, with an IP20 protective environment rating.

Environmental Requirements
Temperature Range: -25°C to + 55°C(-13°F to +131°F)Humidity range: 20% to 95%Supply Voltage: AC/DC Adapter. Base Station Input Voltage 12VDC, 1.5A

Industrial E-Ink System Overview
An Industrial E-Ink system consists of Industrial E-Ink tags, Industrial E-Ink server, switches, base stations. The product information in the database will be copied from the host computer to the Industrial E-Ink system application software; then updated contents and other information will be sent via Ethernet to the Base Stations which will then deploy the update throughout the entire store via 2.4GHz wireless transmission Each part is described below:
E-Ink server: Running E-Ink System;Switch: For data exchange between the base station and the server;Base Station: For data exchange between the E-Ink and the Hub ; Industr ial E-In k tags: Updatable display for stored server information.

E-Ink-MP240B-Base-Station-fig-1

Technical Characteristics

Key Performance Areas
Uses 2.4GHz frequency within ISM band, worldwide compatibility E-InkTags proprietary wireless protocol to ensure data security.
And Support independent research and development of Industrial E-Ink tags of Shanghai Alpla AIOT Technology Co., Ltd.

Key Performance Areas
Uses 2.4GHz frequency within ISM band, worldwide compatibility E-Ink Tags proprietary wireless protocol to ensure data security.
And Support independent research and development of Industrial E-Ink tags of Shanghai Alpla AIOT Technology Co., Ltd.

Detail Specifications

Electrical Characteristics

Parameter|
---|---

Power Supply

| DC12V, 1.5A
POE(optional)
Power| <2.5W
Standby Current| 650mA
Operating Current| 800mA

Network Interface

|

10/100M Ethernet TC P Protocol

IP Rating| IP20

RF Characteristics

Parameter Specification
Modulation GFSK
Frequency 2.402 to 2.4835GHz
Transmit Power 13dBm
Reciever Sensitivity [email protected]%BER
Antenna VSWR ≤ 1.5:1
Communication Distance 10m to 20m

Base Station Antenna Radiation Pattern

E-Ink-MP240B-Base-Station-fig-2

Base Station Installation

Panel Description

E-Ink-MP240B-Base-Station-fig-3

Label Name Use
PWR Power LED Lights when Base Station Powered

LAN

-Err

|

LAN error LED

|

Lights when Base Station Lan error

SYS

|

System Status LED

| Indicates normal System Status
SYS

-Err

| System error LED| Lights when Base Station System error
DC12V| Power Port| 12VDC Power Connection (DC plug socket)
LAN| Network Port| Network cable into Base Station
NC| Noused Port| No used Port

Power Supply and Networking

Shown in the below figure the MP240B can be powered in two ways:

Method Power Supply Description Connections

Border 1

|

Power Supply

| When the switch doesnot provide power andexternal power is required| Provide 12V to DC12V

socket Connect Ethernet to LAN port

Border 2

|

POE

|

When the switch provide POE power

|

Connect Ethernet POE Port to LAN port

| | |

fig

Method Power Supply Description Connections

Border 1

|

Power Supply

| When the switch doesnot provide power andexternal power is required| Provide 12V to DC12V

socket Connect Ethernet to LAN port

Border 2

|

POE

|

When the switch provide POE power

|

Connect Ethernet POE Port to LAN port

| | |

E-Ink-MP240B-Base-Station-fig-4

Installation Conditions
Before Installation Check that the product is intact and all attachments are complete, if there is damage or missing parts please contact Alpha-Rfid promptly.
Check whether the following installation conditions exist before continuing:
A) Installation will meet applicable workplace standards.
B) Complete the required Installation processes.

Installation Location
The choice of Base Station position depends on its installation, it should be where possible, in a place free of obstacles that is safe and easy to operate.
The MP240B Base Station can be mounted on the ceiling and or walls depending on

Installation Method
Before Installation: Configure all Base Station IP Addresses (refer software manual for instructions for this step).
Installation: the Base Station secures with Phillips pan head self-tapping screws connect power cable and Network cable. Typical installation Figures 3-1

Figure 3-1 Base Station Arrangement
The Frame is the building outline, the view is from the top down with the viewof all the Black dots (which are Base Stations) on the ceiling of the building; The Round dotted line circles are the Base Station signal coverage areas, typical coverage depending on the environment is between 10m to 20m in a simple open environment for a single Base Station.

Figure 3-2 shows the inter Base Station installation distance, the dotted line represents the Base Station wireless signal coverage area;
Ensure the distance betwen base stations is less than or equal to 20m.

Precautions

  1. The MP240B power supply shipped has an input range of 100V to 240Vac 360mA please ensure it is able to be supplied with the correct voltage.
  2. Ensure that equipment is grounded.
  3. Check the Base Station and antenna installation position and orientation concerning the E-Ink that will be exchanging data.
  4. This product radiates Radio Frequency (RF) energy, the installation and commissioning personnel should leave at least 30cm between themselves and the antenna in order to meet the FCC requirements for human exposure.
  5. Any radio transmitting equipment, including this Base Station, can be interfered with by medical devices without proper protection. If there are problemsseek the medical device manufacturer for advice.
  6. This equipment may cause interference with other electronic devices.

Troubleshooting

Symptom Cause Troubleshooting Comment

Power LED Does not light

|

Power Adapter may not work

|

Check Mains socket has power and is on,

replace adapter if it does

|
|

Interface Cable not

| Reconnect cable or|
| connectedor| replaceif this still
Network| has problem| no response
Communication not normal| |
Base StationIP configuration Problem may exist| Use the E-Ink Startup softwareto configure Base Station IP Address|

Warranty

Thank you for purchasing the Alpha-Rfid product. The products you have purchased have a limited warranty service during the given warranty period in whichwe will provide the warranty services. The product warranty card is sent along with the
product, please t keep it safe, if the product needs warranty service, please returnit together with the warranty card to Alpha-Rfid.
To learn more about our products or if you have any need or help, please visit our website www.greentag.cn or contactus directly, our contact details on the last page of this manual, we will be happy to serve you.

Disclaimer:
This manual belongs to Shanghai Alpha AIOT T echnology Co., Ltd.

(hereinafter referred to as “Alpha-Rfid”), it cannot be reproduced in part or whole without the express permission of Alpha-Rfid.. Parties that do reproduce in part, or whole, this document risk legal action.

Copyright:

Alpha-Rfid
document, and has no obligations to notify any person of these modifications of Alpha-Rfid reserves the right to modify the terms and specifications within this

FCC

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any inte rference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interferenceto radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

Shanghai Alpha AIOT Technology Co., Ltd.

Address:No.88,Xiangyuan Road,Gongshu district,Hangzhou, China

E-Mail:[email protected]
TEL : +86 571-88139887

www.alpha-rfid.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

E-Ink User Manuals

Related Manuals