Pulmodyne DART100 Nasal Device User Guide

June 15, 2024
Pulmodyne

Pulmodyne-LOGO

Pulmodyne DART100 Nasal Device

Product Information

Specifications

  • Product Name: Intranasal Mucosal Atomization Device
  • Models: DART100, DART300, DART140
  • DART100 includes: DART Nasal Device with 3mL Syringe
  • DART300 includes: DART Nasal Device without Syringe
  • DART140 includes: DART Nasal Device with 3mL Syringe and Vial Adapter

Product Usage Instructions

  1. Remove the DART from the packaging.
  2. Twist the Vial Adapter on clockwise and remove the cap.
  3. Add the desired medication to the syringe.
  4. Twist Counter clockwise to remove the Vial Adapter.
  5. Titrate to clinical effect in 5-15 minutes with another appropriate dose of medication if indicated.
  6. Reattach the Nasal device to the syringe (turn clockwise).
  7. Place the tip of the device into the patient’s nostril. The device should be pointing slightly up and laterally (towards the tip of the patient’s ear on the same side of the head).
  8. Compress the syringe plunger briskly until half the dose enters one nostril, repeat on the opposite side to administer the remaining medication.

Additional Tips:

  • Apply pressure to maximize the atomization.
  • Ensure complete coverage of the treated surface area.
  • Excessive mucosal moisture may reduce absorption of medication.

FAQ

Q: Where can I find additional information about the DART?
A: For additional information regarding the DART, please visit our website at www.pulmodyne.com or call 317.900.4093.

INSTRUCTION

Pulmodyne-DART100-Nasal-Device-1

Pulmodyne-DART100-Nasal-Device-2

  1. Remove the DART from the packaging
  2. Twist the Vial Adpater on clockwise and remove the cap.
  3. Add the desired medication to the syringe.
  4. Twist Counter clockwise to remove the Vial Adapter
  5. Reattach the Nasal device to the syringe (turn clockwise.)
  6. Place the tip of the device into the patients nostril. The device should be pointing slightly up and laterally (towards the tip of the patients ear on the same side of the head ).
  7. Compress the syringe plunger briskly until half the dose enters one nostril, repeat on the opposite side to administer the remaining medication.
  8. Titrate to clinical effect in 5-15 minutes with another appropriate dose of medication if indicated.

DART100 – DART Nasal Device with 3mL Syringe

DART300 – DART Nasal Device without Syringe

DART140 – DART Nasal Device with 3mL Syringe and Vial Adapter

Additional Tips:

  • Compress the Syringe with a brisk pressure to maximize the atomization.
  • Utilize both nostrils to increase the treated surface area.
  • Mucous, blood, and vasoconstrictor may reduce absorption of medication.