OSBURN OB04016 Wood Fireplace Oven Instruction Manual

June 15, 2024
OSBURN

OB04016 Wood Fireplace Oven

Product Information

Specifications

  • Model: EVEREST II (OB04016)

  • Certification: US Environmental Protection Agency phase II
    certified wood fireplace compliant with 2020 cord wood
    standard

  • Safety Testing: ULC S610, UL 127 standards by an accredited
    laboratory

Introduction

Thank you for choosing the EVEREST II wood fireplace
manufactured by Stove Builder International. As one of North
America’s largest and most respected wood stove and fireplace
manufacturers, we take pride in the quality and performance of all
our products.

This installation and operation manual provides you with general
advice on wood heating, detailed instructions for safe and
effective installation, and guidance on how to get the best
performance from this fireplace.

Important Safety Information

Before proceeding with the installation and use of this wood
fireplace, it is crucial to read and understand the following
safety instructions:

  • Installation: Improper installation may cause overheating of
    combustible materials and increase the risk of fire. Follow the
    installation instructions in this manual carefully.

  • Local Regulations: Contact your local building or fire
    officials to inquire about any restrictions and installation
    inspection requirements specific to your area.

  • Property Damage and Injury: Failure to follow these
    instructions could result in property damage, bodily injury, or
    even death.

Online Warranty Registration

To ensure warranty coverage, it is important to register your
product online at https://www.osburn-mfg.com/en/warranty/warranty- registration/.
If repairs are needed during the warranty period, proof of purchase
must be provided.

Product Usage Instructions

Part A – Operation and Maintenance

1. Safety Information

Before operating the EVEREST II wood fireplace, familiarize
yourself with the following safety guidelines:

  • Keep flammable materials away from the fireplace.

  • Always use dry, well-seasoned wood for optimal performance and
    reduced emissions.

  • Regularly inspect the chimney and clean it as necessary to
    prevent creosote buildup.

  • Ensure proper ventilation in the room to avoid the buildup of
    carbon monoxide.

  • Keep children and pets away from the fireplace when it is in
    use.

2. General Information

The EVEREST II wood fireplace offers efficient heating and a
cozy ambiance. Here are some general guidelines for its
operation:

  • Ensure there is an alternative heat source available in your
    home as this unit may serve as a supplementary heat source.

  • Consult your home insurance company and local authorities
    regarding any necessary permits or notifications for installing the
    fireplace and chimney.

  • Position the fireplace on a non-combustible surface and
    maintain proper clearances from combustible materials.

  • Follow the recommended maintenance schedule provided in this
    manual to ensure optimal performance and safety.

3. Fuel

The quality of fuel used in the EVEREST II wood fireplace
greatly affects its performance. Follow these guidelines for
selecting and using fuel:

  • Use only dry, well-seasoned hardwood for efficient and clean
    burning.

  • Avoid using wet or green wood as it produces excessive smoke
    and decreases efficiency.

  • Do not burn garbage, treated wood, or any materials other than
    natural firewood.

4. Operating the Fireplace

To operate the EVEREST II wood fireplace safely and effectively,
follow these steps:

  1. Open the damper fully before lighting the fire.

  2. Place kindling and small pieces of dry wood on the fire
    grate.

  3. Ignite the fire using an appropriate fire starter.

  4. Add larger pieces of well-seasoned wood once the fire has
    established.

  5. Adjust the air controls to regulate the burn rate and maintain
    a steady flame.

  6. Regularly add wood to sustain the fire, ensuring not to
    overload the fireplace.

  7. Monitor the fire and chimney for any signs of excessive smoke
    or unusual behavior.

  8. Extinguish the fire completely before leaving the fireplace
    unattended.

Frequently Asked Questions (FAQ)

Q: Is a building permit required for installing the EVEREST II

wood fireplace?

A: Yes, it is highly recommended to check with your local
authorities regarding any necessary permits or notifications for
installation. Inform your home insurance company as well.

Q: What type of wood should I use as fuel?

A: Dry, well-seasoned hardwood is recommended for optimal
performance and reduced emissions. Avoid using wet or green
wood.

Q: Can the EVEREST II wood fireplace be used as the primary

heat source in a home?

A: This unit is designed to serve as a supplementary heat
source. It is recommended to have an alternative primary heat
source available in your home.

Installation and Operation Manual
EVEREST II
(OB04016 model)

ENGLISH

TRADITIONAL
US Environmental Protection Agency phase II certified wood fireplace compliant with 2020
cord wood standard

MODERN
Safety tested according to ULC S610, UL 127 standards by an accredited
laboratory.

CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN LOCAL AREA.

READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS WOOD FIREPLACE. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH.

Printed in Canada

READ AND KEEP THIS MANUAL FOR REFERENCE

46186A 2023-09-28

ENGLISH

If this fireplace is not installed properly, combustible materials near it may overheat and catch fire.
To reduce the risk of fire, follow the installation instructions in this manual.

THANK YOU FOR CHOOSING THIS WOOD FIREPLACE

As one of North America’s largest and most respected wood stove and fireplace manufacturers, Stove Builder International takes pride in the quality and performance of all its products.
The following pages provide general advice on wood heating, detailed instructions for safe and effective installation, and guidance on how to get the best performance from this fireplace.
It is highly recommended that this wood burning hearth product be installed and serviced by professionals who are certified by a «Qualified Agency» such as NFI (National Fireplace Institute®) or CSIA (Chimney Safety Institute of America) in the United States and in Canada by WETT (Wood Energy Technology Transfer) or in Quebec by APC (Association des Professionnels du Chauffage).

Contact local building or fire officials about restrictions and installation inspection requirements in your local area.
A building permit might be required for the installation of this fireplace and the chimney that it is connected to. It is also highly recommended to inform your home insurance company.
Please read this entire manual before installing and using this fireplace.
A primary alternative heat source should be available in the home. This heating unit may serve as a supplementary heat source. The manufacturer cannot be responsible for additional heating costs associated with the use of an alternative heat source.

ONLINE WARRANTY REGISTRATION
If the unit requires repairs during the warranty period, proof of purchase must be provided. The purchase invoice must be kept. The date indicated on it establishes the warranty period. If it cannot be provided, the warranty period will be determined by the date of manufacture of the product. It is also highly recommended to register the warranty online at
https://www.osburn-mfg.com/en/warranty/warranty-registration/
Registering the warranty will help to quickly find the information needed on the unit.

Installation and Operation Manual – Everest II

Page 3

TABLE OF CONTENTS

PART A – OPERATION AND MAINTENANCE …………………………………………………………………… 7

1. Safety Information……………………………………………………………………………………………………. 7

ENGLISH

2. General Information …………………………………………………………………………………………………. 8
2.1 Performances…………………………………………………………………………………………………… 8 2.2 Specifications ………………………………………………………………………………………………….. 9 2.3 Dimensions……………………………………………………………………………………………………..10 2.4 EPA Loading ……………………………………………………………………………………………………13 2.5 Materials…………………………………………………………………………………………………………14 2.6 Zone Heating …………………………………………………………………………………………………..14 2.7 Emissions and Efficiency …………………………………………………………………………………….15
3. Fuel ………………………………………………………………………………………………………………………. 15
3.1 Tree Species……………………………………………………………………………………………………15 3.2 Log Length ……………………………………………………………………………………………………..16 3.3 Piece Size ………………………………………………………………………………………………………16 3.4 Compressed Wood Logs…………………………………………………………………………………….16 3.5 Drying Time …………………………………………………………………………………………………….17
4. Operating the Fireplace ………………………………………………………………………………………….. 18
4.1 Using a Firescreen…………………………………………………………………………………………….18 4.2 Blower Operation………………………………………………………………………………………………18
5. Burning Wood Efficiently ………………………………………………………………………………………… 19
5.1 First Use…………………………………………………………………………………………………………19 5.2 Lighting Fires …………………………………………………………………………………………………..19 5.3 Combustion Cycles …………………………………………………………………………………………..20 5.4 Rekindling a Fire……………………………………………………………………………………………….21 5.5 Removing Ashes ………………………………………………………………………………………………21 5.6 Air Intake Control ……………………………………………………………………………………………..22 5.7 Fire Types ……………………………………………………………………………………………………….22
6. Maintenance………………………………………………………………………………………………………….. 24
6.1 Cleaning and Painting ………………………………………………………………………………………..24 6.2 Refractory Material and Baffle ………………………………………………………………………………24 6.3 Glass Door ……………………………………………………………………………………………………..25 6.4 Door ……………………………………………………………………………………………………………..27 6.5 Exhaust System ……………………………………………………………………………………………….28
PART B ­ INSTALLATION …………………………………………………………………………………………….. 30

7. Safety Information and Standards …………………………………………………………………………… 30
7.1 Safety ……………………………………………………………………………………………………………30 7.2 Standards……………………………………………………………………………………………………….31
8. Fireplace Installation………………………………………………………………………………………………. 31 8.1 Standoff Installation …………………………………………………………………………………………..31 8.2 Optional Carrying Handles …………………………………………………………………………………..31 8.3 Location …………………………………………………………………………………………………………32 8.4 Clearances to Combustibles ………………………………………………………………………………..32 8.5 Framing Construction…………………………………………………………………………………………32

Page 4

Installation and Operation Manual – Everest II

ENGLISH

8.6 Hearth Extension Construction ……………………………………………………………………………..36 8.7 Facing ……………………………………………………………………………………………………………40 8.8 Shelf Installation ……………………………………………………………………………………………….41 9. The Venting System ……………………………………………………………………………………………….. 42 9.1 Location …………………………………………………………………………………………………………42 9.2 Supply of Combustion Air ……………………………………………………………………………………43 9.3 Chimney Installation …………………………………………………………………………………………..43 9.4 Angled Wall Pass-Thru Installation …………………………………………………………………………48 9.5 Chimney Support Installation………………………………………………………………………………..48 9.6 Approved Chimneys ………………………………………………………………………………………….50 Appendix 1: INSTALLING THE DOOR OVERLAY …………………………………………………………… 52
Appendix 2: Faceplate Installation ………………………………………………………………………………. 53
Appendix 3: Optional Fresh Air Intake Installation ………………………………………………………… 54
Appendix 4: Optional traditional Hot Air Gravity Kit Installation ……………………………………… 57
Appendix 5: Optional Forced Air Kit Installation……………………………………………………………. 60
Appendix 6: Optional Firescreen Installation ………………………………………………………………… 61
Appendix 7: Refractory Panels Removal………………………………………………………………………. 62
Appendix 8: Secondary Air Tubes and Baffle Installation ………………………………………………. 63
Appendix 9: Blower Replacement ……………………………………………………………………………….. 64
Appendix 10: Exploded Diagram and Parts List ……………………………………………………………. 66
OSBURN Limited Lifetime Warranty……………………………………………………………………………… 69

Dealer: Installer: Phone Number: Serial Number:
Installation and Operation Manual – Everest II

Page 5

CERTIFICATION PLATE

ENGLISH

Page 6

Installation and Operation Manual – Everest II

PART A – OPERATION AND MAINTENANCE

ENGLISH

1. Safety Information
· This fireplace has been tested for use with an open door in conjunction with a firescreen, sold separately. The door may be opened, or firescreen removed only during lighting procedures or reloading. Always close the door or put back on the firescreen after ignition. Do not leave the fireplace unattended when the door is opened with or without a firescreen.
· WARNING : OPERATE ONLY WITH THE DOOR FULLY CLOSED OR FULLY OPEN WITH THE FIRESCREEN IN PLACE. IF THE DOOR IS LEFT PARTLY OPEN, GAS AND FLAME MAY BE DRAWN OUT OF THE OPENING, CREATING RISKS FROM BOTH FIRE AND SMOKE.
· HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. GLOVES MAY BE NEEDED FOR THE FIREPLACE OPERATION.
· Using a fireplace with cracked or broken components, such as glass, firebricks or baffle may produce an unsafe condition and may damage the fireplace.
· NEVER USE GASOLINE, LANTERN FUEL (NAPHTHA), FUEL OIL, MOTOR OIL, KEROSENE, CHARCOAL LIGHTER FLUID, OR SIMILAR LIQUIDS OR AEROSOLS TO START A FIRE IN THIS FIREPLACE. KEEP ALL SUCH LIQUIDS OR AEROSOLS WELL AWAY FROM THE FIREPLACE WHILE IT IS IN USE.
· Do not store fuel within heater minimum installation clearances.
· Burn only seasoned natural firewood.
· This wood heater needs periodic inspection and repairs for the proper operation. It is against federal regulations to operate this wood heater in a manner inconsistent with operating instructions in this manual.
· Do not obstruct air inlets. This fireplace needs air for its good operation.
· Do not block the hot air vents of the fireplace as this will cause the fireplace to overheat.
· A smoke detector, a carbon monoxide detector and a fire extinguisher should be installed in the house. Location of detectors should be chosen wisely to avoid false alarm when reloading the appliance. The location of the fire extinguisher should be known by all family members.
· Do not use makeshift materials or make any compromises when installing this fireplace.
· Mixing of appliance components from different sources or modifying components is prohibited and will void the warranty. Any modification of the fireplace that has not been approved in writing by the testing authority is prohibited and violates CSA B365 and NFPA 211 standards.
· The manufacturer grants no warranty, implied or stated, for the poor installation or lack of maintenance of this fireplace and assumes no responsibility for any consequential damages.
· Do not elevate the fire by means of grates, chenets, andirons or any other means.

WARNING This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to www.P65warnings.ca.gov/

Installation and Operation Manual – Everest II

Page 7

2. General Information
2.1 Performances Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time and maximum heat output.

ENGLISH

Model

Everest II (OB04016)

Fuel Type

Dry Cordwood

Combustion Technology

Non-Catalytic

Recommended heating area (sq. ft..)1

750 to 2,500 ft2 (70 to 232 m2)

Overall firebox volume

3.0 ft3 (0.085 m3)

EPA loading volume

2.61 ft3 (0.074 m3)

Maximum burn time1

9 hours

Maximum heat output (dry cordwood)2
Overall heat output rate (min. to max.)2 3
Average overall efficiency3 Dry cordwood Optimum overall efficiency6

85,000 BTU/h (24.9 kW)
18,057 BTU/h to 49,654 BTU/h (5.29 kW to 14.55 kW)

65.7 % (HHV)4

70.8 % (LHV)5

72 %

Optimum heat transfer efficiency7

68 %

Average particulate emissions rate8

0.99 g/h (EPA / CSA B415.1-10)9

Average CO10

50.1 g/h

1 Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure. 2 The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft3 and 20 lb/ft3. Other performances are based on a fuel load prescribed by the standard. The specified loading density varies between 7 lb/ft³ and 12 lb/ft3. The moisture content is between 19% and 25%. 3 As measured per CSA B415.1-10 stack loss method. 4 Higher Heating Value of the fuel. 5 Lower Heating Value of the fuel. 6 Optimum overall efficiency at a specific burn rate (LHV). 7 The optimum heat transfer efficiency is for the low burn rate and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion. 8 This appliance is officially tested and certified by an independent agency. 9 Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053-17. 10 Carbon monoxide.

Page 8

Installation and Operation Manual – Everest II

ENGLISH

2.2 Specifications
Maximum log length11 Flue outlet diameter Recommended connector pipe diameter Type of chimney Baffle material Approved for mobile home installation12 Type of door Type of glass Blower Particulate emission standard13 USA standard (Safety) Canada standard (Safety)

18 in (457 mm) east-west 6 in (152 mm) 6 in (152 mm) CAN/ULC S629, UL 103 HT (2100 °F) Ceramic Board No Double, glass with cast-iron frame Ceramic glass Included (up to 176 CFM) EPA / CSA B415.1-10 UL 127 ULC S610

11 North-south: ends of the logs visible, East-west: sides of the logs visible. 12 Mobile homes (Canada) or manufactured homes (USA): The US Department of Housing and Urban Development describes “manufactured homes” better known as “mobile homes” as follows; buildings built on fixed wheels and those transported on temporary wheels/axles and set on a permanent foundation. In Canada, a mobile home is a dwelling for which the manufacture and assembly of each component is completed or substantially completed prior to being moved to a site for installation on a foundation and connection to service facilities and which conforms to the CAN/CSAZ240 MH standard. 13 Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053-17.

Installation and Operation Manual – Everest II

Page 9

2.3 Dimensions

ENGLISH

Top view

Front view
G : Opening for Hot air gravity kit (ø 8″).
Page 10

Front view – Door opening Installation and Operation Manual – Everest II

ENGLISH

Left side view

Right side view

Bottom view
F : Opening for Hot air gravity kit (ø 6″). A : Opening for fresh air intake (ø 4″). Installation and Operation Manual – Everest II

Page 11

ENGLISH

Combustion chamber – Top view

Page 12

Left view – Faceplate projection

Combustion chamber – Side view Installation and Operation Manual – Everest II

ENGLISH

2.4 EPA Loading
The loading methods shown below are those used during emissions certification. Fuel used was beech cordwood and fuel length was 16 ± 1 inches.
2.4.1 Air control
The air control is located below the ash shelf on the right. To open the air control, push the air control handle completely to the right (High). This will increase the burn rate. To close the air control, push the air control handle completely to the left (Low). This will decrease the burn rate.
2.4.2 High burn rate (primary air control open)
Open the air control completely. Criss cross 8 small pieces (2″x2″) of wood into the firebox in 2 layers (3 in the bottom, 3 in the middle, 2 on the top). Criss cross 10 to 12 finely split kindling wood pieces over the small pieces of wood. Tie knot with five sheets of paper and place them on top of the kindling wood. Light up the paper and let the door completely open until the 2 top layers are burning. Close the door. When the kindling and the small pieces of wood are almost completely burnt out and it is possible to break them into small pieces, level the coal bed and put 6 logs in the firebox. Place 2 small pieces (about 3″ x 3″) in the bottom in a reverse V shape, then put two medium size pieces (about 4″x4″) in an East-West orientation in the back, one over the other (over the reverse V). Put the 2 last medium size pieces (about 4″x4″) in the front, one over the other. Try to leave air space between the pieces. Let the door open at 90° for 3 minutes or when the fire is fully established and close the door. Leave the air control fully opened.
2.4.3 Medium and low burn rate
On a 2″ coal bed that is dark red, add 6 pieces of wood in the firebox. Place 2 small pieces (about 2.5″ x 2.5″) in the bottom in a reverse V shape, then put 2 medium size pieces (about 4″x4″) in an East-West orientation in the back (over the reverse V), one over the other. Put a big piece (about 5″x5″) in an East-West orientation in the front (over the reverse V) and put a last medium size piece (about 4″x4″) over the big one. Try to leave air space between the pieces. Let the door open at 90° for 5 minutes or when the fire is fully established and close the door. Leave the primary air control open for approximately 5 minutes and then close the primary air control halfway. After another 5 minutes, close the air control completely for the low burn rate and 7/32″ open for the medium burn rate.

Installation and Operation Manual – Everest II

Page 13

2.5 Materials
The body of this fireplace, which is most of its weight, is carbon steel. Should it ever become necessary many years in the future, almost the entire fireplace can be recycled into new products, thus eliminating the need to mine new materials.
The paint coating on the fireplace is very thin. Its VOC content (Volatile Organic Compounds) is very low. VOCs can be responsible for smog, so all the paint used during the manufacturing process meets the latest air quality requirements regarding VOC reduction or elimination.

ENGLISH

The air tubes are stainless steel, which can also be recycled.
Moulded refractory panels are mainly composed of silicon dioxide, also known as silica, a product processed from a mined mineral. It is most commonly found in nature in the form of sand and clay. Disposal at a waste management center is recommended. The steel mesh contained in some refractory bricks can also be recycled.

The door and glass gaskets are fibreglass which is spun from melted sand. Black gaskets have been dipped into a solvent-free solution. Disposal at a waste management center is recommended.

The door glass is a 5/32″ (4 mm) thick ceramic material that contains no toxic chemicals. It is made of natural raw materials such as sand and quartz that are combined in such a way to form a high temperature glass. Ceramic glass cannot be recycled in the same way as normal glass, so it should not be disposed of with regular household products. Disposal at a waste management center is recommended.

2.6 Zone Heating
This fireplace is a space heater, which means it is intended to heat the area it is installed in, as well as spaces that connect to that area, although to a lower temperature. This is called zone heating and it is an increasingly popular way to heat homes or spaces within homes. Zone heating can be used to supplement another heating system by heating a particular space within a home, such as a basement, a family room or an addition that lacks another heat source.

Houses of moderate size and relatively new construction can be heated with a properly sized and located wood fireplace. Whole house zone heating works best when the fireplace is in the part of the house where the family spends most of its time. This is normally the main living area where the kitchen, dining and living rooms are located.

Locating the fireplace in this area will give the maximum benefit of the heat it produces and will achieve the highest possible heating efficiency and comfort. The space where the most time is spent will be warmest, while bedrooms and basement (if there is one) will stay cooler. In this way, less wood is burnt than with other forms of heating.

Although the fireplace may be able to heat the main living areas of the house to an adequate temperature, it is strongly recommended to also have a conventional oil, gas or electric heating system to provide backup heating.

The success of zone heating will depend on several factors, including the correct sizing and location of the fireplace, the size, layout and age of your home and your climate zone. Threeseason vacation homes can usually be heated with smaller fireplaces than houses that are heated all winter.

Page 14

Installation and Operation Manual – Everest II

ENGLISH

2.7 Emissions and Efficiency
The low smoke emissions produced by the special features inside this fireplace firebox mean that the household will release up to 90% less smoke into the outside environment than if an older conventional fireplace was used. But there is more to the emission control technologies than protecting the environment.
The smoke released from wood when it is heated contains about half of the energy content of the fuel. By burning the wood completely, this fireplace releases all the heat energy from the wood instead of wasting it as smoke up the chimney. Also, the features inside the firebox allow control of the air supply meaning controlling the heat output, while maintaining clean and efficient flaming combustion, which boosts the efficient delivery of heat to the home.
The emission control and advanced combustion features of this fireplace can only work properly if the fuel used is in the correct moisture content range of 15% to 20%. Refer to the following section of suggestions on preparing fuelwood and judging its moisture.

3. Fuel
Good firewood has been cut to the correct length for the fireplace, split to a range of sizes and stacked in the open until its moisture content is down to 15% to 20%.

DO NOT BURN:

· GARBAGE;

· SALT WATER DRIFTWOOD OR OTHER

· LAWN CLIPPINGS OR YARD WASTE;

PREVIOUSLY SALT WATER SATURATED

· MATERIALS CONTAINING RUBBER, MATERIALS;

INCLUDING TIRES;

· UNSEASONED WOOD; OR

· MATERIALS CONTAINING PLASTIC;

· PAPER

PRODUCTS,

CARDBOARD,

· WASTE PETROLEUM PRODUCTS, PAINTS OR PAINT THINNERS, OR ASPHALT

PLYWOOD, OR PARTICLE BOARD. THE PROHIBITION AGAINST BURNING THESE

PRODUCTS;

MATERIALS DOES NOT PROHIBIT THE

· MATERIALS CONTAINING ASBESTOS; · CONSTRUCTION OR DEMOLITION DEBRIS; · RAILROAD TIES OR PRESSURE-TREATED
WOOD; · MANURE OR ANIMAL REMAINS;

USE OF FIRE STARTERS MADE FROM PAPER, CARDBOARD, SAW DUST, WAX AND SIMILAR SUBSTANCES FOR THE PURPOSE OF STARTING A FIRE IN AN AFFECTED WOOD HEATER.

BURNING THESE MATERIALS MAY RESULT IN THE RELEASE OF TOXIC FUMES OR RENDER THE HEATER INEFFECTIVE AND CAUSE SMOKE.

3.1 Tree Species
The tree species the firewood is produced from is less important than its moisture content. The main difference in firewood from various tree species is the density of the wood. Hardwoods are denser than softwoods.

Homeowners with access to both hardwood and softwood use both types for different purposes. Softer woods make good fuel for mild weather in spring and fall because they light quickly and produce less heat.

Softwoods are not as dense as hardwoods so a given volume of wood contains less energy.

Installation and Operation Manual – Everest II

Page 15

ENGLISH

Using softwoods avoids overheating the house, which can be a common problem with wood heating in moderate weather. Harder woods are best for colder winter weather when more heat and longer burn cycles are desirable. Hardwood trees like oak, maple, ash and beech are slower growing and longer lived than softer woods like poplar and birch. That makes hardwood trees more valuable. The advice that only hardwoods are good to burn is outdated. Old, leaky cast iron fireplaces wouldn’t hold a fire overnight unless they were fed large pieces of hardwood.
3.2 Log Length Logs should be cut at least 1″ (25 mm) shorter than the firebox so they fit in easily. Pieces that are even slightly too long makes loading the fireplace very difficult. The most common standard length of firewood is 16″ (400 mm).
3.3 Piece Size Firewood dries more quickly when it is split. Large unsplit rounds can take years to dry enough to burn. Even when dried, unsplit logs are difficult to ignite because they don’t have the sharp edges where the flames first catch.
Wood should be split to a range of sizes, from about 3″ to 6″ (75 mm to 150 mm) in cross section. Having a range of sizes makes starting and rekindling fires much easier.
3.4 Compressed Wood Logs Compressed wood logs made of 100% compressed sawdust can be burned with caution in the number of these logs burned at once. Do not burn compressed logs made of wax impregnated sawdust or logs with any chemical additives. Do not poke or stir the logs while they are burning.
Use only logs that meet the requirements of ULC/ORD C127 M1990 for composite logs. Refer to package cautions and warnings before using logs.

Page 16

Installation and Operation Manual – Everest II

ENGLISH

3.5 Drying Time
Firewood that is not dry enough to burn is the cause of most complaints about wood-burning appliances. Continually burning green or unseasoned wood produces more creosote and involves lack of heat and dirty glass doors.
Firewood with a moisture content between 15% and 20% will allow the fireplace to produce its highest possible efficiency.
Here are some facts to consider in estimating drying time:
– Firewood bought from a dealer is rarely dry enough to burn, so it is advisable to buy the wood in spring and dry it yourself;
– Drying happens faster in dry weather than in a damp climate;
– Drying happens faster in warm summer weather than in winter weather;
– Split pieces dry more quickly than unsplit rounds;
– Softwoods like pine, spruce, poplar, and aspen take less time to dry than hardwoods. They can be dry enough to burn after being stacked to air dry only for the summer months;
– Hardwoods like oak, maple and ash can take one, or even two years to dry fully, especially if the pieces are big;
– Firewood dries more quickly when stacked outside in a location exposed to sun and wind; it takes much longer to dry when stacked in a wood shed;
– Firewood with a moisture content of 15% to 20% will allow the fireplace to reach its highest efficiency.
Firewood is dry enough to burn when:
– Cracks form at the end of logs;
– The wood turns from white or cream colored to grey or yellow;
– Two pieces of wood struck together sounds hollow;
– The face of a fresh cut feels warm and dry;
– The moisture content read by a moisture meter is between 15% to 20%.

Installation and Operation Manual – Everest II

Page 17

4. Operating the Fireplace
This wood heater has a manufacturer-set minimum low burn rate that must not be altered. It is against federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual.

ENGLISH

4.1 Using a Firescreen
This product should not be operated with door open using fire screen (AC01379) in the United States or provinces where any particulate matter emission rate limit is enforced (ex: US EPA).
This fireplace has been tested for use with an open door in conjunction with a firescreen, sold separately. The firescreen must be properly secured on the fireplace to avoid any risk of sparks damaging the flooring. When the firescreen is in use, do not leave the fireplace unattended to respond promptly in the event of smoke spillage into the room. Potential causes of smoke spillage are described in Section «9. The Venting System» of this manual. See «Appendix 6: Optional Firescreen Installation» for installation instructions.
Operating the fireplace with a firescreen increases possibilities of generating carbon monoxide. Carbon monoxide is an odourless gas that is highly toxic which can cause death at high concentration in air. Installation of a carbon monoxide detector is highly recommended.

4.2 Blower Operation

A blower (A) is already installed in the fireplace. It is located behind the faceplate, at the bottom of the fireplace. Its function is to increase airflow around the fireplace air jacket and improve hot air circulation in the room. When used regularly, the blower can provide a small increase in efficiency, up to 2%. However, the use of a blower should not be used as a way to gain more output from a fireplace that is undersized for the space it is intended to heat.

The blower can operate in automatic or manual mode. To choose the mode, just press the rocker switch (B) and choose «AUTO» for automatic mode and «MAN» for manual mode.

Automatic mode: Press the rocker switch (B) and choose the «AUTO» mode. Choose the operating speed of the blower with the rheostat button (C) above. The blower will start automatically when the fireplace is warm and will shut down automatically when the fireplace is cold.

Manual mode: Press the rocker switch (B) and select the «MAN» mode. Choose the operating speed of the blower with the rheostat button (C) above. The blower will start immediately. The blower must be stopped manually, either by turning the rheostat button (C) fully to the left or by changing the mode.

OFF: To completely turn off the blower, turn the rheostat button (C) counterclockwise until the

blower stops.

Page 18

Installation and Operation Manual – Everest II

ENGLISH

5. Burning Wood Efficiently
5.1 First Use Two things happen when burning the first few fires; the paint cures and the internal components are conditioned. As the paint cures, some of the chemicals vaporize. The vapors are not poisonous, but they smell bad. Fresh paint fumes can also trigger false alarms in smoke detectors. When lighting the heater for the first few times, it may be wise to open doors and windows to ventilate the house.
Burn two or three small fires to begin the curing and conditioning process. Then build bigger and hotter fires until there is no longer paint smell from the fireplace. As hotter and hotter fires are burned, more of the painted surfaces reach the curing temperature of the paint. The smell of curing paint does not disappear until one or two very hot fires have been burned.
5.2 Lighting Fires Each person heating with wood develops its own favorite way to light fires. Regardless of the method chosen, the goal should be to have a hot fire burning, quickly. A fire that ignites fast produces less smoke and deposits less creosote in the chimney.
Never use gasoline, gasoline-type lantern fuel (naphtha), fuel oil, motor oil, kerosene, charcoal lighter fluid, or similar liquids or aerosols to start or `freshen up’ a fire in this wood fireplace. Keep all such liquids well away from the fireplace while it is in use.
Here are three popular and effective ways to ignite wood fires.
5.2.1 Conventional Method
The conventional method to build a wood fire is to crumple 5 to 10 sheets of newspaper and place them in the firebox and hold them in place with ten pieces of kindling wood. The kindling should be placed on and behind the newspaper.
Then add two or three small pieces of firewood. Open the air intake control completely and ignite the newspaper. Leave the door slightly ajar. Once the fire has ignited, the door can be closed with the air control still fully open. When the kindling is almost completely burned, standard firewood pieces can be added.
Do not leave the fireplace unattended when the door is slightly open. Always close and latch the door after the fire ignites.
5.2.2 The Top Down Method
This method is the opposite of the conventional method and only works properly if well-seasoned wood is used.
Place three or four small, split, dry logs in the firebox. Arrange the kindling wood on the logs in two layers at right angles and place a dozen finely split kindling on the second row. It is possible to use ragged paper but it may not hold in place since it tends to roll while it is burning. The best is to wrap a sheet on itself, grab the ends of the roll and make a knot.

Installation and Operation Manual – Everest II

Page 19

Use four or five sheets of paper tied together and put them on top and around the kindling. Open the air intake control completely, ignite the paper and close the door.
The top down fire method has two advantages over the traditional method: first, the fire does not collapse on itself, and it is not necessary to add wood gradually since the combustion chamber is full before the fire is lit.
The following load orientation is the one who will give the best performance for this fireplace. The figure below is for reference only. The quantity and size of the logs may vary.

ENGLISH

5.2.3 Two Parallel Logs Method
Two spit logs are placed in the firebox with a few sheets of twisted newspapers in between the logs. Fine kindling is added across the two logs and some larger kindling across those, log cabin style. Newspaper is lit.

5.2.4 Using Fire Starters
Commercial fire starters can be used instead of a newspaper. Some of these starters are made of sawdust and wax and others are made of specialized flammable solid chemicals. Always follow the package directions when using.
Gel starters can also be used, but only to light a fire, in a cold combustion chamber without hot embers inside.

5.3 Combustion Cycles

Wood heating with a space heater is very different than other forms of heating. There will be temperature variations in different parts of the house and there will be temperature variations throughout day and night. This is normal, and for experienced wood burners these are advantages of zone heating wood burning.

Wood heaters don’t have a steady heat output. It is normal for the temperature to rise after a new load of wood is ignited and for its temperature to gradually decrease throughout the burning cycle.

This increasing and decreasing temperature can be matched with the household routines. For example, the temperature in the area can be cooler when the household is active, and it can be warmer when it is inactive.

Page 20

Installation and Operation Manual – Everest II

Wood burns best in cycles. A cycle starts when a new load of wood is ignited by hot coals and ends when that load has been consumed down to a bed of charcoal about the same size as it was when the wood was loaded.
Trying to produce a steady heat output by placing a single log on the fire at regular intervals is not recommended. Always place at least three, and preferably more pieces on the fire at a time so that the heat radiated from one piece helps to ignite the pieces next to it. Each load of wood should provide several hours of heating. The size of each load may vary depending on the amount of heat required.
Burning in cycles means the loading door does not need to be opened while the wood is flaming. This is an advantage since it is preventing smoke leaking from the heater when the door is opened as a full fire is burning. This is especially true if the chimney is on the outside wall of the house.
If the door must be opened while the fire is flaming, fully open air control for a few minutes then open the door slowly.
5.4 Rekindling a Fire
When the temperature of the room is lower and all that remains is embers, it is time to reload. Remove excess ash from the front of the firebox and bring the ashes forward. Place a new load of wood on, and at the back of the embers. Open the air control completely and close the door.

ENGLISH

Raking the coals is useful for two reasons. First, it brings them near where most of the combustion air enters the firebox. This will ignite the new load quickly. Secondly, the charcoal will not be smothered by the new load of wood. When the embers are simply spread inside the combustion chamber, the new load smoulder for a long time before igniting.
Close the air control only when the firebox is full of bright turbulent flames, the wood is charred, and its edges are glowing.
The heater should not be left unattended during ignition and the fire should not burn at full intensity for more than a few minutes.
When lighting a new load, the appliance produces a heat surge. This heat surge is pleasant when the room temperature is cool but can be unpleasant when the room is already warm. Therefore, it is best to let each load of wood burn completely so that the room cools down before putting a load of wood back on.

5.5 Removing Ashes

Ash should be removed from the firebox every two to three days of full-time heating. Ash should not accumulate excessively in the firebox since it will affect the proper operation of the appliance.

Installation and Operation Manual – Everest II

Page 21

The best time to remove ash is in the morning, after an overnight fire when the fireplace is relatively cold, but there is still a little chimney draft to draw the ash dust into the fireplace and prevent going out into the room.
Ashes should be placed in a tightly covered metal container. The container must be placed on a non-combustible floor or on the ground well away from all combustible materials. Ashes almost always contain live embers that can stay hot for days and which release carbon monoxide gas. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be kept in a closed metal container until they are completely cooled. No other waste should be placed in this container.

ENGLISH

CENDRES ASHES

NEVER STORE ASHES INDOORS OR IN A NON-METALLIC CONTAINER OR ON A WOODEN DECK.

5.6 Air Intake Control
Once the firewood, firebox and chimney are hot, air intake can be reduced to achieve a steady burn.
As the air intake is reduced, the burn rate decreases. This has the effect of distributing the thermal energy of the fuel over a longer period of time. In addition, the flow rate of exhaust through the appliance and flue pipe slows down, which increases the duration of the energy transfer of the exhaust gases. As the air intake is reduced, the flame slows down.
If the flames diminish to the point of disappearing, the air intake has been reduced too early in the combustion cycle or the wood used is too wet. If the wood is dry and the air control is used properly, the flames should decrease, but remain bright and stable.
On the other hand, too much air can make the fire uncontrollable, creating very high temperatures in the unit as well as in the chimney and seriously damaging them. A reddish glow on the unit and on the chimney components indicates overheating. Excessive temperatures can cause a chimney fire.
5.7 Fire Types
Using the air intake control is not the only way to match the fireplace heat output to the desired temperature in the house. A house will need far less heating in October than in January to maintain a comfortable temperature. Filling the firebox full in fall weather will overheat the space. Otherwise, the combustion rate will have to be reduced to a minimum and the fire will be smoky and inefficient.

Page 22

Installation and Operation Manual – Everest II

ENGLISH

Here are some suggestions for building fires suitable for different heating needs.

5.7.1 Flash Fire
To build a small fire that will produce a low heat output, use small pieces of firewood and load them crisscross in the firebox. The pieces should only be 3″ (76 mm) to 4″ (102 mm) in diameter. After raking the coals, lay two pieces parallel to each other diagonally in the firebox and lay two more across them in the other direction. Open the air control fully and only reduce the air after the wood is fully flaming.
This kind of fire is good for mild weather and should provide enough heat for up to four hours. Small fires like this are a good time to use softer wood species and avoid overheating the house.

5.7.2 Low and Long Output Fires
For a fire that will last up to eight hours but will not produce intense heat, use soft wood and place the logs compactly in the firebox. Before reducing the air intake, the load will have to burn at full heat for long enough for charring the surface of the logs. The flame must be bright before letting the fire burn by itself.

5.7.3 High Output Fires
When heating needs are high during cold weather, the fire should burn steadily and brightly. This is the time to use larger pieces of hardwood. Place the biggest pieces at the back of the firebox and place the rest of the pieces compactly. A densely built fire like this will produce the longest combustion this fireplace is capable of. Special attention must be paid when building fires like this since if the air intake is reduced too quickly, the fire could smoulder. The wood must be flaming brightly before leaving the fire to burn.

5.7.4 Maximum Burn Cycle Times

The burn cycle time is the period between loading wood on a coal bed and the consumption of that wood back to a coal bed of the same size. The flaming phase of the fire lasts for roughly the first half of the burn cycle and the second half is the coal bed phase during which there is little or no flame. The burning time expected from this fireplace, including both phases, will vary depending on a number of things, such as:

– firebox size, – the amount of wood loaded, – the species of wood, – the wood moisture content,

– the size of the space to be heated, – the climate zone where the house is, and – the time of the year.

The table below gives an approximate maximum burn cycle times, based on firebox volume.

Table 1 : Approximate Maximum Burn Cycle Time

FIREBOX VOLUME

MAXIMUM BURN CYCLE TIME

<1.5 cubic feet 1.5 c.f. to 2.0 c.f 2.0 c.f. to 2.5 c.f. 2.5 c.f. to 3.0 c.f.

3.0 c.f.

3 to 5 hours 5 to 6 hours 6 to 8 hours 8 to 9 hours 9 to 10 hours

Installation and Operation Manual – Everest II

Page 23

ENGLISH

A longer burning time is not necessarily an indication of efficient fireplace operation. It is preferable to build a smaller fire that will provide three or four hours of heating than to fully load the firebox for a much longer burn. Shorter burn cycles make it easier to match the heat output of the fireplace to the heat demand for the space.
5.7.5 Logs Orientation In a relatively square firebox, the wood can be loaded north-south (ends of the logs visible) or east-west (sides of the logs visible).
North-south loads allow more wood to be loaded at the same time. On the other hand, they break into smaller pieces faster. North-south loading is good for high output, long lasting fires for cold weather.
East-west loads allow a limited amount of wood since too many logs could cause them to fall on the glass. East-west loads, placed in a compact way, take a long time before breaking down. They are excellent for low-intensity, long- lasting fires in relatively mild weather.
5.7.6 Carbon Monoxide When there is no more flame in the firebox and there are still some unburned logs, check outside if there is smoke coming out of the chimney. If this is the case, it means that the fire is out of air to burn properly. In this situation, the level of CO increase and it is important to react. Open the door slightly and move the logs with a poker. Create a passage for the air below by making a trench with the ember bed. Add small pieces of wood to restart the combustion.
6. Maintenance
This heater will give many years of reliable service if used and maintained properly. Internal components of the firebox such as firebricks or refractory panels, baffle and air tubes will wear over time. Defective parts should always be replaced with original parts.
To avoid premature deterioration, follow the lighting and reloading procedures in section «5. Burning Wood Efficiently» and also avoid letting the heater run with the air intake fully open for entire burn cycles.
6.1 Cleaning and Painting
Painted and plated surfaces can be wiped down with a soft, damp cloth. If the paint is scratched or damaged, it is possible to repaint the fireplace with a heat-resistant paint. Do not clean or paint the fireplace when it is hot. Before painting, the surface should be sanded lightly with sandpaper and then wiped off to remove dust. Apply two thin layers of paint.
6.2 Refractory Material and Baffle
The intense heat of the fire can cause slight cracks in the refractory panels. It is possible to minimize the appearance of these cracks by hardening the panels as described in the section «5.1 First Use». Slight cracks will not reduce the effectiveness of the panels. On the other hand, if wider cracks appear, they must be replaced. Inspect the refractory panels and the baffle for damage periodically and replace anything that is cracked or broken.
Operation of the heater with a cracked or missing baffle may cause unsafe temperatures and hazardous conditions and will void the warranty.

Page 24

Installation and Operation Manual – Everest II

ENGLISH

6.3 Glass Door 6.3.1 Cleaning Under normal conditions, the door glass should stay relatively clear. If the firewood is dry enough and the operating instructions in this manual are followed, a whitish, dusty deposit will form on the inner surface of the glass after a week or so of use. This is normal and can be easily removed when the heater is cold by wiping with a damp cloth or paper towel and then drying.
When the fireplace runs at a low combustion rate, light brown stains may form, especially in the lower corners of the glass. This indicates that the fire has been smoky and some of the smoke has condensed on the glass. It also indicates incomplete combustion of the wood, which also means more smoke emissions and faster formation of creosote in the chimney.
The deposits that form on the glass are the best indication of the fuel quality and success in properly using the fireplace. These stains can be cleaned with a special wood stove glass cleaner. Do not use abrasive products to clean the glass.
The goal should be having a clear glass with no brown stains. If brown stains appear regularly on the glass, something about the fuel or the operating procedure needs to be changed. When brown streaks are coming from the edge of the glass, it is time to replace the gasket around the glass. Always replace the gasket with a genuine one.
Do not clean the glass when the fireplace is hot.
Do not abuse the glass door by striking or slamming shut.
Do not use the fireplace if the glass is broken.
6.3.2 Replacement The glass used is a ceramic glass, 5/32″ (4 mm) thick,12 ½” x 11 ” (319 mm x 283 mm) tested to reach temperatures up to 1400º F. If the glass breaks, it must be replaced with one having the same specification. Tempered glass or ordinary glass will not withstand the high temperatures of this unit.
To replace the glass, use the following procedure;
Remove the glass retaining screws (A) and clips (B) then the metal frames (C) that hold the glass (D) to the door frame (E). Lift out the glass (D) and pull off the old gasket. Do the same for the other door.
This is a good time to clean the glass thoroughly.

Installation and Operation Manual – Everest II

Page 25

ENGLISH

To remove or replace the glass (G):
1. Remove the door (H) and place it face-down on something soft. 2. Remove the glass retainers (E) held in place by the screws (D). 3. Remove the frames (F). 4. Remove the glass. If it is damaged install a new one in place. The
replacement glass must have a gasket all around. 5. Reinstall the glass, being careful to centre the glass in the door and not
to over-tightening the retaining screw.
The two main causes of broken door glass are uneven placement in the door and over-tightening the retaining screws.
6.3.3 Gasket The glass gasket is flat, adhesive-backed, woven fibreglass. The gasket must be centred on the edge of the glass.
1. Follow the steps of the previous section to remove the glass. 2. Remove the old gasket and clean the glass thoroughly. 3. Peel back a section of the paper covering the adhesive and place the gasket on a table with the
adhesive side up. 4. Stick the end of the gasket to the middle of one edge, then press the edge of the glass down onto
the gasket, taking care that it is perfectly centred on the gasket. 5. Peel off more of the backing and rotate the glass. The gasket must not be stretched during
installation. 6. Cut the gasket to the required length. Pinch the gasket onto the glass in a U-shape, all around
the glass.

Page 26

Installation and Operation Manual – Everest II

ENGLISH

6.4 Door

In order for the fireplace to burn at its best efficiency, the door must provide a perfect seal with the firebox. Therefore, the gasket should be inspected periodically to check for a good seal. The tightness of the door seal can be verified by closing and latching the door on a strip of paper. The test must be performed all around the door. If the paper slips out easily anywhere, either adjust the door or replace the gasket.

At the end of each heating season it is recommended to add a high temperature graphite paste on the threads of the door handles. This paste will protect the threads from rust and prevent dust accumulation that can prevent the handles from rotating freely.

6.4.1 Adjustment The door seal may be improved with a simple latch mechanism adjustment on the right door:

1. Remove the split pin by pulling and turning it using pliers.

2. Turn the handle one counterclockwise turn to increase pressure.
3. Reinstall the split pin with a small hammer.

Installation and Operation Manual – Everest II

Page 27

6.4.2 Gasket
Use the correct replacement gasket: (A) for the doors and (B) for the doors junction. Both can be purchased from your retailer. The diameter and density of the gasket is important to getting a good seal.
Place the doors face-down on something soft like a cushion of rags or piece of carpet. Remove the old gaskets from the door by pulling and prying it out with an old screw driver. Then use the screwdriver to scrape the old gasket adhesive from the door. Now run a 1/4″ (6 mm) bead of high temperature silicone in the door frame gasket groove of the door gasket. Starting from the middle of the hinge side, press the gasket into the groove. Do not stretch the gasket as you place it. Leave the gasket about 1/2″ long when you cut it and press the end into the groove. Tuck any loose fibres under the gasket and into the silicone. Do the same for center door gaskets. Repeat for the other door. Close the door and do not use the fireplace for 24 hours.

ENGLISH

Location On each door frame Center door gasket

Length 38″ (96 cm) 14″ (36 cm)

Dimension Round 5/8″ (16 mm) Round 1/4″ (6 mm) self-adhesive

6.5 Exhaust System
Wood smoke can condense inside the chimney, forming an inflammable deposit called creosote. If creosote builds up in the system, it can ignite when a hot fire is burned in the insert. A very hot fire can progress to the top of the chimney. Severe chimney fires can damage even the best chimneys. Smouldering, smoky fires can quickly cause a thick layer of creosote to form. When the insert is operated properly, the exhaust from the chimney is mostly clear and creosote builds up more slowly.

«Creosote – Formation and Need to Removal
When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cooler chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When ignited this creosote makes an extremely hot fire. The chimney connector and chimney should be inspected at least once every two months during the heating season to determine if a creosote buildup has occurred. If creosote has accumulated (” [3 mm] or more it should be removed to reduce the risk of a chimney fire»

Page 28

Installation and Operation Manual – Everest II

ENGLISH

6.5.1 Cleaning frequency It is not possible to predict how much or how quickly creosote will form in the chimney. It is important, therefore, to check the buildup in the chimney monthly until the rate of creosote formation is determined. Even if creosote forms slowly in the system, the chimney should be cleaned and inspected at least once each year. Establish a routine for the fuel, wood burner and firing technique. Check daily for creosote buildup until experience shows how often you need to clean to be safe. Be aware that the hotter the fire, the less creosote is deposited and weekly cleaning may be necessary in mild weather even though monthly cleaning may be enough in the coldest months. Contact your local municipal or provincial fire authority for information on how to handle a chimney fire. Have a clearly understood plan to handle a chimney fire.
6.5.2 Sweeping the Chimney Chimney sweeping can be a difficult and dangerous job. People with no chimney sweeping experience will often prefer to hire a professional chimney sweep to inspect and clean the system for the first time. After seeing the cleaning process, some will choose to do it themselves. The chimney should be checked regularly for creosote buildup. Inspection and cleaning of the chimney can be facilitated by removing the baffle. See «Appendix 8: Secondary Air Tubes and Baffle Installation» for more details.
6.5.3 Chimney Fire Regular chimney maintenance and inspection can prevent chimney fires. If you have a chimney fire, follow these steps:
1. Close the fireplace doors and the air intake control;
2. Alert the occupants of the house of the possible danger;
3. If you require assistance, alert the fire department;
4. If possible, use a dry chemical fire extinguisher, baking soda or sand to control the fire. Do not use water as it may cause a dangerous steam explosion;
Do not use the fireplace again until the fireplace and its chimney have been inspected by a qualified chimney sweep or a fire department inspector.

Installation and Operation Manual – Everest II

Page 29

ENGLISH

PART B ­ INSTALLATION
Install the fireplace only as described in these instructions and using only the following fireplace components and chimney components from chimney manufacturers listed in «Table 4 : Approved Chimneys».
· Fireplace; · Faceplate; · Overlay; · Insulated chimney made by the manufacturers listed in Table 4, with the corresponding specifications:
– Chimney lengths; – Elbows (where necessary); – Associated components as per these installation instructions.
Additional Equipment (optional)
· Forced air kit; · Traditional hot air gravity kit; · Fresh air intake kit; · Firescreen;
7. Safety Information and Standards
7.1 Safety
· The fireplace and chimney must be in an enclosure up to the attic.
· CAUTION: DO NOT ATTEMPT TO MODIFY OR ALTER THE CONSTRUCTION OF THE FIREPLACE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION OF CONSTRUCTION MAY VOID THE WARRANTY, LISTINGS AND APPROVAL OF THIS SYSTEM. IN THAT CASE, STOVE BUILDER INTERNATIONAL (SBI) WILL NOT BE RESPONSIBLE FOR DAMAGES. INSTALL THE FIREPLACE ONLY AS DESCRIBED IN THESE INSTRUCTIONS.
· Mixing of appliance components from different sources or modifying components are prohibited and will void the warranty. Any modification of the fireplace that has not been approved in writing by the testing authority is prohibited and violates CSA B365 (Canada) and NFPA 211 (USA) standards.
· The manufacturer grants no warranty, implied or stated, for the poor installation or lack of maintenance of the fireplace and assumes no responsibility for any consequential damages.
· Do not use a fireplace insert and other products not specified for use with this fireplace.
· Do not install in a mobile home (Canada) or a manufactured home (USA).
· Do not use materials other than those listed in the replacement parts section during installation as they may be safety hazards and a fire could result.
· WARNING : THIS FIREPLACE HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET. TO REDUCE THE RISK OF FIRE OR INJURY, DO NOT INSTALL AN UNVENTED GAS LOG SET INTO THIS FIREPLACE.

Page 30

Installation and Operation Manual – Everest II

7.2 Standards
When installed and operated as described in these instructions, this wood fireplace is suitable for use in residential installations.
In Canada, the CSA B365 «Installation Code for Solid Fuel Burning Appliances and Equipment» and the CSA C22.1 «Canadian National Electrical Code» are to be followed in the absence of local code requirements. In the USA, the ANSI NFPA 211 «Standard for Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances» and the ANSI NFPA 70 «National Electrical Code» are to be followed in the absence of local code requirements.
This fireplace is not approved for use with a so-called “positive flue connection” to the clay tile of a masonry chimney.
8. Fireplace Installation
8.1 Standoff Installation
Before installing the fireplace, it is mandatory to install the standoffs on the top (L) , on the sides and (O) and (P) the back (N) of the fireplace. The standoffs can be found in the fireplace firebox and and the screws (M) to install them can be found in the fireplace manual.

ENGLISH

8.2 Optional Carrying Handles To facilitate the transport of the fireplace, handles sold as an option may be used. They are installed on each side of the fireplace. Wearing gloves is strongly recommended when moving the fireplace.
Installation and Operation Manual – Everest II

Page 31

ENGLISH

8.3 Location
The best location for the fireplace should consider the location of windows, doors, and circulation in the room. There must be enough space in front of the fireplace for the hearth extension and mantel and on the sides or back for the different heat distribution system, for the fresh air intake and for the chimney. Ideally, the chimney must be able to pass through the house without the need to cut floor joists or roof trusses.

8.4 Clearances to Combustibles
The clearances shown in this section have been determined by test according to procedures set out in safety standards ULC S610 (Canada) and UL127 (U.S.A.). When the fireplace is installed so that its surfaces are at or beyond the minimum clearances specified, combustible surfaces will not overheat under normal and even abnormal operating conditions.

No part of the fireplace may be located closer to the combustible than the minimum clearance given.

A material is considered non-combustible when made entirely of steel, iron, bricks, tiles, concrete, slate, glass or a combination of these materials. Materials corresponding to ASTM E136 and UL 763 are considered to be non- combustible materials with the exception of gypsum, which will be considered a non-combustible material only if it is certified to withstand an ambient temperature of use of 250°F and more.

– Maximum mantle depth 3″ (76 mm)

– Mantle minimum distance 8″ (203 mm) (measured from the door opening)

– Side wall distance 21″ (533 mm) (measured from the door opening)

– Minimum distance to the wall in front of the fireplace 48″ (1220 mm) in Canada and 36″ (914 mm) in USA
– Minimum ceiling height : 80″ (2,03 m) measured from the base of the fireplace.
Fireplace enclosure : – Back wall : 0″ – Sides : 0″ – Floor (underneath the fireplace) : 0″

3″ 76mm
45°

8″ 203mm

21″ 533mm

8.5 Framing Construction
The frame, on the sides and back of the fireplace, must be made of 2″x 3″ (5 cm x 8 cm) or larger. The front studs as well as headers on top of the fireplace must be made of non-combustible materials and be of a depth no more than the depth of the top standoffs. The standoffs can be installed either flush with the fireplace or setback of ½” depending on the thickness of the finishing material used.

Page 32

Installation and Operation Manual – Everest II

ENGLISH

Do not use combustible materials for the frame directly above the fireplace. This area should remain empty to a height of 80″ (2.03 m) measured from the base of the fireplace.

Build the fireplace frame using vertical studs placed on the sides of the fireplace, from the floor to the ceiling. The studs must be set back from the front edge of the fireplace by a space equivalent to the thickness of the finishing material, so that it is flush with the finish of the fireplace. Headers between studs should be installed as follows:

NON COMBUSTIBLE

COMBUSTIBLE

– The headers must be 2″ x 3″ (5 cm x 8 cm) or 2″ x 4″ (5 cm x 10 cm). Do not put wood or other material in the area above the fireplace.

– Install only the cripple studs needed to support

the finishing material and mantle.

41 3/4″ 953mm
MIN.

COMBUSTIBLE

VARIABLE

COMBUSTIBLE

8.5.1 Framing with gravity air kit install Non-combustible
E
F G

The framing dimensions are for reference only.
Framing touching the grills must be made from non-combustible materials (dark area). Finishing material covering the dark framing must be made from non- combustible materials. See facing section.
E: Minimum distance between the grill and the combustible ceiling (8″)
F: Minimum distance below the grill to noncombustible stud (14″)
F: Minimum distance between the grill and a non-combustible shelf (Not shown) (15″)
G: Distance between the framing and the first stud (3″)

Installation and Operation Manual – Everest II

Page 33

WARNING : DO NOT FILL THE REQUIRED EMPTY SPACE INSIDE THE ENCLOSURE WITH INSULATION OR ANY OTHER MATERIAL.

Cet espace doit rester vide
This space must remain empty

The fireplace must not be in contact with any insulation or loose filling material. Inside the chase, around the fireplace, insulation should be covered with drywall panels or any other finishing material except where noncombustible material is required.

80″ 2032mm

49 1/8″ 1248 mm

ENGLISH

VARIABLE
8.5.2 Fireplace Framing Framing dimensions should be used as a reference only If a finishing material is installed inside the enclosure, its thickness must be added to the following measurements. – Framing width 42 ¾” (1086 mm) – Framing height to the first header 49 5/8″
80″
(1260 mm) – Framing depth 24 ½” (622 mm) – Framing total height 80″ (2032 mm)
Page 34

Non Combustible
49 5/8″ 24 1/2″
42 3/4″
Installation and Operation Manual – Everest II

8.5.3 Framing with Fresh Air Intake14

ENGLISH

If a finishing material is installed inside the enclosure, its thickness must be added to the following measurements.
A : Fresh air intake duct15 (Fresh air intake can be installed on the right, left or underneath). B : Distance between framing and side fireplace standoff 12″ (305 mm) C : Framing width (Installation with centered fireplace) 60 ¾” (1543 mm)
8.5.4 Framing with forced air kit16

If a finishing material is installed inside the enclosure, its thickness must be added to the following measurements.

D : Forced air duct17 (Duct can be installed on the left [recommended] or on the right). E : Distance between framing and side fireplace standoff 18″ (457 mm) F : Framing width (Installation with centered fireplace) 72 ¾” (1848 mm)

14 Framing dimensions are for reference only. These measurements are recommended to prevent the ducts from being inside the standoff or have too tight duct curves. Smaller dimensions can be used depending on the size and type of duct as well as the configuration of the installation. 15 HVAC duct, as per ULC S110 or UL 181, class 0 or class 1, must withstand temperatures up to 250oF. 16 Framing dimensions are for reference only. These measurements are recommended to prevent the ducts from being inside the standoff or have too tight duct curves. Smaller dimensions can be used depending on the size and type of duct as well as the configuration of the installation. 17 HVAC duct, as per ULC S110 or UL 181, class 0 or class 1, must withstand temperatures up to 250oF.

Installation and Operation Manual – Everest II

Page 35

8.5.5 Framing with corner installation

ENGLISH

Framing configuration should be used as a reference only. If a finishing material is installed inside the enclosure, its thickness must be added to the following measurements. Theses values are minimum measurements and may need to be increased to allow the installation of the fresh air intake, the forced air kit or the type of finishing material used.

8.6 Hearth Extension Construction
This fireplace can be installed directly on the floor or on a raised base, combustible or not. The installation can be done according to one of the following options :

OPTION INSTALLATION TYPE

1

On floor level

2

Raised base of less than 4″

3

Raised base of 4″ or more

R FACTOR REQUIRED Yes (1.00) Yes (1.00)
No

NON-COMBUSTIBLE FLOOR PROTECTION DEPTH 16″ (406 mm) 16″ (406 mm) 16″ (406 mm)

8.6.1 Option #1 – Floor Level Installation

D D

When the fireplace is installed directly on the floor, a non-combustible floor protection of at least 16″ (A) with an R factor of 1.00 must be installed in front of the fireplace.

The joint between the floor protection and the

A

fireplace must be protected over the entire width

of the floor protection by a folded and continuous

metal sheet (D = min 2″ [51 mm]) (not supplied).

A clearance of 80″ (2.03 m) between the base of the fireplace and the ceiling must be respected.

The minimum floor height under the fireplace should match (or exceed) the height of noncombustible materials used for floor protection.

Page 36

Installation and Operation Manual – Everest II

ENGLISH

8.6.2 Option #2 – Raised Base Installation of Less Than 4″

When the fireplace is installed on a raised base of less than 4″ (E), a noncombustible floor protection of at least 16″ (A) with an R factor of 1.00 must be installed in front of the fireplace.

D E
D

The joint between the floor protection

A

F

and the fireplace must be protected over

the entire width of the floor protection

by a folded and continuous metal sheet

(D = min 2″ [51 mm]) (not supplied).

It is recommended to make the sheet

metal in one piece.
E

A clearance of 80″ (2.03 m) (F) between the base of the fireplace and the ceiling must be respected.

8.6.3

Option #3 – Raised Base Installation of 4″ or More
When the fireplace is installed on a raised base of 4″ or more (E), a noncombustible floor protection of at least 16″ (A) with no R factor must be installed in front of the fireplace.

D D E
D D

The upper and lower angle, for the
A
full width of the floor protection, must
F
be protected by 2″ horizontally and

vertically by a folded and continuous

metal sheet (D = 2″ [51 mm])

(not supplied). The sheet metal does

not have to cover the rest of the wall

between the base of the fireplace and

E

the floor. A clearance of 80″ (2.03 m) (F)

between the base of the fireplace and

the ceiling must be respected.

Installation and Operation Manual – Everest II

Page 37

ENGLISH

8.6.4 Floor Protection OPTION INSTALLATION TYPE

1 On floor level #2 Raised base of less than 4″ #3 Raised base of 4″ or more

R FACTOR REQUIRED Yes (1.00)
Yes (1.00)
No

A
16″ (406 mm)
16″ (406 mm)
16″ (406 mm)

B
36 ¾” (933 mm)
36 ¾» (933 mm)
36 ¾» (933 mm)

C
8″ (203 mm)
8″ (203 mm)
8″ (203 mm)

Regardless of the installation type, there must be at least 8″ (203 mm) on each side of the fireplace door opening (C).

Floor protection must be a continuous non-

combustible surface such as ceramic, concrete

board, brick or other equivalent material

approved as floor protection. If the ceramic

is used, it must be placed on a continuous

non-combustible panel to prevent spills from

being brought into contact with the floor

C

through cracks or gaps in the ceramic slurry.

Alternatives approved by the local building

code may also be used.

Do not leave carpets under the floor

protection.

B

A

Page 38

Installation and Operation Manual – Everest II

ENGLISH

8.6.5 R Factor

There are two ways to calculate the R-value of the floor protection. First, by adding the R-values of materials used, or by the conversion if the K factor and thickness of the floor protection are given.

To calculate the total R value from R values of the materials used, simply add the R-values of materials. If the result is equal to or greater than the R-value requirements, the combination is acceptable. R-values of some selected materials are shown below :

Table 2 : Thermal Characteristics of Common Floor Protection Materials18

MATERIAL

CONDUCTIVITY (K) RESISTANCE (R) PER INCH

PER INCH

THICKNESS

Micore® 160

0.39

2.54

Micore® 300

0.49

2.06

Durock®

1.92

0.52

Hardibacker®

1.95

0.51

Hardibacker® 500

2.3

0.44

Wonderboard®

3.23

0.31

Cement mortar

5.00

0.2

Common brick

5.00

0.2

Face brick

9.00

0.11

Marble

14.3 ­ 20.00

0.07 ­ 0.05

Ceramic tile

12.5

0.008

Concrete

1.050

0.950

Mineral wool insulation

0.320

3.120

Limestone

6.5

0.153

Ceramic board (Fibremax)

0.450

2.2

Horizontal still air (” [3 mm] thick)

0.135

0.92019

Example: Required floor protection R of 1.00. Proposed materials: four inches of brick and one inch of Durock® board.
Four inches of brick (R = 4 x 0,2 = 0,8) plus 1 inch of Durock® (R = 1 x 0.52 = 0.52). 0.8 + 0.52 = 1.32.
This R value is larger than the required 1.00 and is therefore acceptable.

In the case of a known K and thickness of alternative materials to be used in combination, convert all K values to R by dividing the thickness of each material by its K value. Add R values of the proposed materials as shown in the previous example.

Common brick K value = 5 Thickness = 4″ R value = Thickness/K = 4/5 = 0.8

Durock K value =1.92 Thickness = 1″ R value = Thickness/K = 1/1.92 = 0.52

Total R value = .8 + 0.52 = 1.32

18 Information as reported by manufacturers and other resources 19 Horizontal still air can’t be «stack» to accumulate R-values; each layer must be separated with another non-combustible material. Installation and Operation Manual – Everest II

Page 39

8.7 Facing
Non-combustible finishing materials such as brick or ceramic can be glued to the facade of the fireplace. Do not put a seal between the faceplate and the finishing material to facilitate the removal of the faceplate if necessary.

Unit without option

Unit with Hot air gravity kit

ENGLISH

Combustibles materials allowed in this zone Non combustible material only in this zone

Page 40

Installation and Operation Manual – Everest II

8.8 Shelf Installation

8.8.1 With the traditional faceplate (OA10619)
A combustible shelf with a depth of 6″ (152 mm) (C) can be installed at least 48″ (1219 mm) (B) from the base of the fireplace. Different shelf sizes are listed in the following table.

POSITIONING AND DEPTH OF THE SHELF

B

C

48″ (1,21 m)

6″ (152 mm)

50″ (1,27 m)

8″ (203 mm)

52″ (1,32 m)

10″ (254 mm)

54″ (1,37 m)

12″ (305 mm)

For a shelf dimension that does not appear in the table, add 42″ (1,07 m) to the depth of the shelf to find the safe position of the shelf. The height (A) should always be 80″ (2.03 m) from the base of the fireplace.

45°
C C

A

A

B B

48″ (Canada) 36″ (USA) 1219 mm 914 mm

ENGLISH

8.8.2 With the modern faceplate (OA10621)
A non-combustible shelf with a depth of 6″ (152 mm) to 12″ (305 mm) can be installed at least 48″ (1219 mm) from the base of the fireplace.

In order to install a combustible shelf with a depth of 6″ (152 mm) (A) at least 48″ (1219 mm) from the base of the fireplace (B), a metal heat shield must be installed 5″ below the combustible shelf (C). The depth (D) of the heat shield is equal to the depth of the combustible shelf minus one inch. Different shelf sizes are listed in the following table.

POSITIONING AND DEPTH OF THE SHELF

B

A

48″ (1,21 m)

6″ (152 mm)

50″ (1,27 m)

8″ (203 mm)

52″ (1,32 m)

10″ (254 mm)

54″ (1,37 m)

12″ (305 mm)

For a shelf dimension that does not appear in the table, add 42″ (1,07 m) to the depth of the shelf to find the safe position of the shelf. The height (E) should always be 80″ (2.03 m) from the base of the fireplace.

Installation and Operation Manual – Everest II

45°
C C

A

A

B B

48″ (Canada) 36″ (USA) 1219 mm 914 mm

Page 41

9. The Venting System
The venting system, acts as the engine that drives the wood-heating system. Even the best fireplace will not function safely and efficiently as intended if it is not connected to a suitable chimney. The heat in the flue gases that pass from the fireplace into the chimney is not waste heat. This heat is what the chimney uses to make the draft that draws in combustion air, keeps smoke inside the fireplace and safely vents exhaust to outside. Heat in the flue gas can be seen as the fuel the chimney uses to make draft.
9.1 Location The location of the chimney is crucial for the proper functioning of the appliance. The chimney should be installed within the house rather than up an outside wall and should rise straight up through the tallest part of the house. This installation benefits from being enclosed within the warm house environment, produce stronger draft, accumulate fewer creosote deposits and will be unaffected by cold temperatures or harsh winds.
Outside chimneys will lead to cold back drafting when there is no fire in the fireplace, slow kindling of new fires, and smoke roll-out when the door is open for loading.

ENGLISH

Page 42

Installation and Operation Manual – Everest II

9.2 Supply of Combustion Air
The safest and most reliable supply of combustion air for a fireplace is from the room in which it is installed. Room air is already preheated so it will not chill the fire, and its availability is not affected by wind pressures on the house. The only case in which the fireplace may not have adequate access to combustion air is if the operation of a powerful exhaust device (such as a kitchen range exhaust) causes the pressure in the house to become negative relative to outdoors.

ENGLISH

9.3 Chimney Installation
The chimney manufacturer’s installation manual takes precedence over the following installation instructions. To ensure a safe installation, please refer to it. Some non-illustrated parts may be required.

9.3.1 General Advices
· This wood burning fireplace has optimum performance and efficiency when connected to a chimney with a 6″ (150 mm) diameter flue, only the chimneys listed in the «Table 4 : Approved Chimneys» can be used.
· To insure a good draft, it is recommended to have a length of 18″ (457 mm) from the top of the unit to the first offset. However, starting using a 30° or 45° (Canada Only) elbow is also approved.
· A CHIMNEY VENTING A FIREPLACE SHALL NOT VENT ANY OTHER APPLIANCE.
· The minimum height of the chimney system is 15 feet (4.6 m) from the base of the appliance to the chimney cap. If only the minimum height of the chimney system is installed, the operating conditions must be optimal (interior chimney, minimum height of 18″ (457 mm) before any deviation, etc.).

Installation and Operation Manual – Everest II

Page 43

ENGLISH

· The chimney must have at least one support. The maximum chimney length that should be supported by the fireplace is 9 feet (2.75 m) for 2″ Solid Pack chimney (5 cm) and 12 feet (3.7 m) for 1″ Solid Pack chimney.
· The chimney must extend at least 3 ft. (92 cm) above its point of contact with the roof and at least 2 ft. (61 cm) higher than any wall, roof or building within 10 ft. (3.1 m) of it.
· WARNING : IF THE CHIMNEY IS INSTALLED IN AN ENCLOSURE ABOVE THE ROOF, IT MUST EXCEED THE STORM COLLAR HEIGHT BY AT LEAST 12 INCHES (30 CM). THE TOP OF THE ENCLOSURE MUST BE MADE OF NON-COMBUSTIBLE MATERIALS.
MORE THAN 10′ (3.1 M) LESS THAN 10′ (3.1 M)

CHIMNEY: 3′ (0.92 M) MINIMUM

10′ (3.1 M)
2′ (0.61 M) MINIMUM

2′ (0.61 M) MINIMUM
RIDGE

CHIMNEY: 3′ (0.92 M) MINIMUM

NOTE: HEIGHT ABOVE ANY ROOF SURFACE WITHIN 10′ (3.1 M) HORIZONTALLY

2′ (0.61 M) MNIMUM

CHIMNEY LESS THAN 10′ (3.1 M)
2′ (0.61 M) MINIMUM

CHIMNEY

CHIMNEY: 3′ (0.92 M) MINIMUM

MORE THAN 10′ (3.1 M)
NOTE: NO HEIGHT ABOVE PARAPET SHALL BE REQUIRED WHEN DISTANCE FROM WALLS OR PARAPET IS MORE THAN 10′ (3.1 M)

CHIMNEY

WALL OR PARAPET

CHIMNEY: 3′ (0.92 M) MINIMUM

CHIMNEY

CHIMNEY

WALL OR PARAPET

· Avoid deviations as much as possible, especially the sharp ones. Each deviation adds restriction to the system and can lead to draft problems.

· If the chimney extends higher than 5 ft. (1.5 m) above its point of contact with the roof, it must be secured using a roof brace.

· A rain cap must be installed on top of the chimney.

· A clearance of 2″ (50 mm) between the chimney and any combustible material is required outside the fireplace’s chase (see section 9.5.3, offset chimney installation, for clearances requirement inside the fireplace’s chase).This space must remain free, without insulation or other combustible material.The parts of the chimney that pass into inhabited spaces must be enclosed in an enclosure.

Page 44

Installation and Operation Manual – Everest II

ENGLISH

· For installations where more than one chimney is located in the same non- chase or within the same area, their terminations must be separated by at least 16″ (410 mm) horizontally, and 18″ (460 mm) vertically. This separation is to prevent smoke migrating from one chimney to a n o t h e r.
· Cut and frame square holes in all floors, ceilings, and roof that the chimney will go through to provide a 2″ (50 mm) minimum clearance between the chimney and any combustible materials. Do not fill this 2″ space with insulation or any other combustible material.
· In all cases, the chimney must start with a 6″ diameter anchor plate attached to the fireplace. · If the male anchor plate nozzle exceeds 2″ (50 mm) in length (A), it must be cut above the
lifting hooks welded inside the flue outlet so that it is sitting perfectly on the top of the fireplace.

Installation and Operation Manual – Everest II

Page 45

9.3.2 Ceiling Supported Installation
G F E
D C
B
A

A : Anchor plate B: Ceiling support C: Framing opening D: Attic insulation shield E: Roof flashing F: Storm collar G: Chimney cap

ENGLISH

1. Cut and frame square openings (C) in the ceiling, floor and roof where the chimney will pass. A 2″ clearance must be maintained between the chimney and any combustible materials. The 2″ space must remain empty, without insulation or any other combustible material. The size of the floor and ceiling holes must be in accordance with the chimney manufacturer’s instructions.
2. From underneath the ceiling, install a ceiling support (B) in each floor where the chimney will pass. In the attic, install an attic radiation shield from above (D).
3. Install an anchor plate (A) and a first chimney section on the fireplace. Install the number of chimney sections needed, making sure to lock each section in place.
4. When the desired height of the chimney is reached, install a roof support (not shown).
5. Put the roof flashing (E) in place and seal the joint between the roof and the flashing with roof sealant. For sloping roofs, place the flashing under the upper shingles and on top of the lower shingles. Nail the flashing to the roof, using roofing nails.
When a ventilated roof flashing is installed, precautions are to be taken not to caulk or seal the ventilating openings.
6. Place the storm collar (F) on the roof flashing and tighten it with the bolt. Seal the joint between the storm collar and the chimney, using silicone sealant.
7. Install the chimney cap (G).

Page 46

Installation and Operation Manual – Everest II

9.3.3 Offset Installation

1. Follow the instructions for a ceiling supported installation until the first elbow.

2. Install and turn the elbow in the right direction.

Attach to the chimney using three ½” (12 mm)

metal screws.

ATTIC

3. Install the appropriate number of chimney sections to obtain the necessary deviation. Secure the chimney sections together with three ½” (12 mm) screws. If the offset section 1ST FLOOR has two or more chimney sections, a bracket must be installed. If the chimney go through a wall, install a wall thimble.

4. Install another elbow to bring the chimney back

in a vertical position.

BASEMENT

5. Continue the installation following the instructions of the ceiling supported installation.

ELBOW FIREPLACE

RAIN CAP STORM COLLAR
FLASHING
WALL BAND
OFFSET SUPPORT ELBOW INSULATED WALL RADIATION SHIELD
CHIMNEY SECTION
CHIMNEY ADAPTOR

ENGLISH

Table 3 : Minimum system height when using elbows

Chimney model Vertical Installation Two (2) elbows Four (4) elbows

See Table 4 15 ft (4,6 m) 15 ft (4,6 m) 17 ft (5,2 m)

9.3.4 Masonry Chimney Installation
The masonry chimney must meet the minimum requirements of the local building code or equivalent for a safe installation. Contact a building inspector to learn about the requirements in the area.
Before starting the installation, the masonry chimney should be inspected for cracks, crumbling mortar, creosote layers, obstructions or other signs of deterioration. If signs of deterioration are noted, the chimney should be repaired and cleaned before installation.

Installation and Operation Manual – Everest II

Page 47

ENGLISH

C B
A

1. Position the fireplace in its location. Temporarily install the elbow or chimney section (A) on the top of the fireplace and, using a level, mark with an oval the location where the flue liner will enter the masonry chimney.
2. Mark where the flue will pass through the masonry chimney. Drill a hole in the masonry chimney to insert an insulated liner adapter (B).
3. Lower the liner (C) into the chimney to the level of the hole.
4. Slide an insulated 45° or 30° liner adapter and connect it to the liner.
5. Seal the opening around the liner with high temperature refractory cement.
6. Then, follow the chimney manufacturer’s instructions to connect the extended liner section to the special chimney connector.
The liner must extend at least 12″ (30 cm) above the masonry chimney.

9.4 Angled Wall Pass-Thru Installation
When passing through a combustible wall with the chimney at a 30° or 45° angle (Canada only), an angled wall pass-thru must be installed. Follow the chimney manufacturer’s installation instructions.
In cold climate locations, it is recommended to use the insulated wall pass- thru to maintain the home’s thermal barrier.

A Wall pass-thru B Interior wall C Exterior wall

9.5 Chimney Support Installation

9.5.1 Roof Support

The universal roof support can be used on:

· a roof to support the chimney; · a floor, ceiling, or roof over an offset to support the chimney or; · as additional support.

Always follow the manufacturer’s instructions for the maximum chimney height that can be supported by the support.

Page 48

Installation and Operation Manual – Everest II

9.5.2 Offset Support This support is used above a chimney offset. When the offset of the chimney pass through a wall, this support can be installed on the wall to support the chimney.
9.5.3 Offset chimney installation
It is permitted to offset the chimney when installing provided that the following measures are always respected. For a left or right deviation (A) there must always be a distance of 11″ between the chimney and combustible materials. For a forward deviation (C) there must always be a distance of 4 3/4″ between chimney and combustible material and rear deflection (B), there should be a 2″ distance between the chimney and combustible materials. It is permitted to offset the chimney when installing the two elbows directly on the anchor plate.

ENGLISH

For example, for the next installation, the chimney cannot be closer to the combustible materials than the value (A). Therefore, the enclosure should be 11 inches from the c h i m n e y.
Installation and Operation Manual – Everest II

Page 49

ENGLISH

9.6 Approved Chimneys

Table 4 : Approved Chimneys

CHIMNEY MANUFACTURER MODEL

TYPE

Olympia Chimney SBI Division Venting SBI Division Venting Olympia Chimney Olympia Chimney Selkirk Selkirk Selkirk Security Chimney DuraVent DuraVent DuraVent DuraVent DuraVent Metal Fab American Metal American Metal

Ventis
Nexvent Champion Chimney System Rockford Chimney Systems CF Sentinel (CF) Super Pro 2100 (ALT) Super Vent 2100 (JM) S-2100+ Dura Tech Dura Tech Canada DTC Dura Tech Premium Dura Plus HTC Dura Plus Temp Guard HSS HS

1″ Solid Pack
1″ Solid Pack 1″ Solid Pack 1″ Solid Pack 2″ Solid Pack 2″ Solid Pack 2″ Solid Pack 2″ Solid Pack 1″ Solid Pack 1″ Solid Pack 2″ Solid Pack 2″ Solid Pack AC Triple Wall 1″ Solid Pack AC Triple Wall AC Triple Wall

DIAMETER
6″ (15 cm)
6″ (15 cm) 6″ (15 cm) 6″ (15 cm) 6″ (15 cm) 6″ (15 cm) 6″ (15 cm) 6″ (15 cm) 6″ (15 cm) 6″ (15 cm) 6″ (15 cm) 6″ (15 cm) 6″ (15 cm) 6″ (15 cm) 6″ (15 cm) 6″ (15 cm)

Page 50

Installation and Operation Manual – Everest II

ENGLISH

CHIMNEY MANUFACTURER Olympia Chimney / SBI Venting Division Security Chimney
DuraVent
American Metal

Table 5 : LIST OF MANDATORY COMPONENTS

MANDATORY COMPONENTS

TYPE/MODEL

· Ventilated roof flashing.
· Requires insulated attic radiation shield unless chimney is enclosed at the attic level.
· Ventilated roof flashing.
· Chimney cannot be enclosed at the attic level.

1″ Solid Pack : Ventis, Nexvent, Champion Chimney System, Rockford Chimney Systems
2″ Solid Pack : S-2100+
1″ Solid Pack: Dura Tech, Dura Tech Canada DTC 2″ Solid Pack: Dura Tech Premium
AC Triple wall : HS AC Triple wall : HSS

9.6.1 Rafter protection
Rafter protectors, at the roof level, must be installed with this unit, if the chimney is enclosed at the attic level. Rafter protectors must be made of 22 ga or more galvanized steel and must have at least the dimension presented on the following diagram:

Installation and Operation Manual – Everest II

Page 51

APPENDIX 1: INSTALLING THE DOOR OVERLAY
In order to complete the assembly of your Everest II wood fireplace, you need to install the door overlay. See figure below for installation instructions:
Position the overlays on the door frames and secure them from the inside of the doors using the 8 included screws.
To facilitate the installation, do not tighten the screws until they are all installed.
Note: It is not necessary to remove the glass or any other component to install the overlay.

ENGLISH

Page 52

Installation and Operation Manual – Everest II

APPENDIX 2: FACEPLATE INSTALLATION
A faceplate must be installed on this fireplace. See the faceplate installation manual for more details.

ENGLISH

Installation and Operation Manual – Everest II

Page 53

ENGLISH

APPENDIX 3: OPTIONAL FRESH AIR INTAKE INSTALLATION
Follow the instructions below for connecting the fireplace to a fresh air intake:
· The insulated flexible pipe (D) should be of sufficient length (at least 10′) and of a configuration to prevent condensation.
· The outside wall register (E) must not be installed: – More than 50% of the total height of the chimney; – At more than 10′ (3 m) above the base of the fireplace; – More than 3′ (0.9 m) below the base of the fireplace.
· The fresh air must come from outside the house. The air intake should not take air in the attic, basement or garage.
· The duct and the air intake can be installed above or below the floor level.
· The air intake should be installed high enough not to be obstructed by snow. It should be protected from the wind, away from automobile exhaust, a gas meter or other air inlets or outlets.
The following items are included with the fireplace: – One (1) 4″ (76 mm) adapter (B); – Four (4) screws.
The following items are not included: – The outside wall register (E); – The two (2) adjustable collars (C);
Insulated duct length 4″ (D). (Duct must be HVAC type and must comply with ULC S110 or UL 181, Class 0 or Class 1 and must withstand temperatures up to 250° F).
Note: Only remove the knockout that will be used to connect the fresh air intake assembly.
The fresh air intake can be installed in two different locations on the fireplace. On the right side (1) of the fireplace (the most common) or underneath the fireplace (2).

Page 54

Installation and Operation Manual – Everest II

ENGLISH

Installation
It is strongly recommended to wear gloves to complete the installation.
1. To use the air intake on the right side, remove the knockout by cutting the micro-joints. Cut and remove the insulation and the other knockout inside the fireplace (1). To use the opening under the fireplace, only cut the knockout.
2. Install the adapter included in the fireplace (2) and align the notch of the adapter (T) with the one on the fireplace. Turn the adapter clockwise.

Fresh air intake on the right side

Fresh air intake underneath

Installation and Operation Manual – Everest II

Page 55

3. Install the flexible duct (D) on the fresh-air inlet adapter (B) using one hose clamp (C). Fix the other end to the outer wall register (E) using the second hose clamp (C). The outer wall register (E) must be installed outside the house.
To properly install the flexible duct, gently remove the insulation and plastic wrap to expose the duct. Fix the duct using clamps. Stick aluminum tape around the joint between the duct and adapter to make the connection airtight. Carefully replace the insulation and plastic wrap on the duct. Secure the plastic with aluminum tape.

ENGLISH

E

BC

D

C

4. To complete the installation, make a hole of ¼” to ½” (6 mm to 13 mm) bigger than the duct diameter on the outside wall of the house at the chosen location. From outside, place the outside wall register in the hole (open side down) and fasten the register to the wall, with screws.
Use the required length for the installation while respecting the maximum length of 30′ (9 m). To avoid condensation, it is recommended to use an insulated duct long enough and containing a «P-Trap» loop. This configuration can be done inside the chase, but must at all times maintain clearances to combustibles.

MIN 10 pi

MAX 3 pi

F

G

It is strongly recommended to install a mechanical shutter that closes the outside air inlet when the fireplace is not in use.

Page 56

Installation and Operation Manual – Everest II

APPENDIX 4: OPTIONAL TRADITIONAL HOT AIR GRAVITY KIT INSTALLATION

The kit includes:

– 2 hot air outlets (grilles (A) and frames (B));

– 2 90o elbows (C);

– 6 steel brackets (D) with fastening screws

(E) and self-tapping screws (F)

C

B

Parts not included in the kit:

A

– 8″ rigid ducting (G), 26 ga, galvanized steel.

G DEF

ENGLISH

Dimensions of hot air outlet frame with elbow

1″ 25mm
TYP.

10 1/4″ 259mm
TYP.
8 1/4″ 208mm
TYP.

18 1/2″ 468mm

5/8″ 14mm

15 1/8″ 383mm

Dimensions of hot air outlet decorative grille with elbow
10″ 254mm
TYP.

7/8″ 23mm
TYP.

5/8″ 14mm
MIN.

2″ 38mm
MAX.

Installation and Operation Manual – Everest II

O

8″ 204mm

Page 57

ENGLISH

Installation rules and advice
· The minimum height of the hot air duct is 68″ (1.7 m). It must be measured from the base of the fireplace to the top of the hot air outlets.
· Do not connect the hot air ducts to a central heating system. The malfunction of the heating system would overheat the fireplace.
· Do not use insulated flexible ducts as they may overheat.
· Do not use «T» fittings or anything other than those listed below.
· All ducts must be placed vertically or horizontally. Never route the ducting downwards.
· The flaps of the hot air outlet grills must point down to prevent overheating of the adjacent ceilings.
· Always install both hot air outlet grilles when the hot air gravity kit is installed.
· The hot air outlets can be installed in the same room as the fireplace, or both can be installed in adjacent rooms or upstairs. If the outlets are installed at different heights, the higher outlet will draw more heat.
· When forced air kit is installed in conjunction with a gravity kit, the forced air device will draw some of the air from the gravity kit ducting, therefore reducing its efficiency.
Clearances
· Maximum length of pipes, including elbows: 10′ (3 m) · The maximum number of elbows allowed per duct is two. · There shall be a clearance of at least 12″ (305 mm) between the hot air outlet frame and a ceiling,
side wall or mantle made of flammable material. · When the duct passes through a wall or floor made of flammable material, a firestop radiation shield
(same as the one used for a class A chimney) must be installed in the opening of the wall or floor. There must be a clearance of at least 2″ (50 mm) between the ducts and the firestop.

12″ MIN.

13″ X 13″ 330mm X 330mm

13″ X 13″ 330mm X 330mm

12″ MIN.
Page 58

Installation and Operation Manual – Everest II

Installation
It is strongly recommended to wear gloves to complete the installation.
A) Remove the knockout that close the 8″ (20 cm) diameter holes on top of the fireplace. Then cut and remove the insulation and the other set of knockout inside the fireplace.

ENGLISH

1 2

B) Screw 6 steel brackets (D) with 6 screws (E) onto the top of the fireplace (3 per duct). Insert the ducts (G) (not supplied) into each opening. Position the ducts as shown in the section view below, for optimal heat capture. Screw each duct in place in the brackets (D) with 6 self-drilling screws (F).

1D

G

E 6X 2 1/4″

56mm

2
6X
F

Installation and Operation Manual – Everest II

Page 59

APPENDIX 5: OPTIONAL FORCED AIR KIT INSTALLATION
It is possible to connect a forced air kit on the back or on either side of the Everest II. This kit allows distributing heat to another room up to 50 feet (15 m) of the fireplace. The insulated flexible pipe (not included in the kit) must be HVAC type pipe and must comply with ULC S110 and/or UL 181, Class 0 or Class 1 Standards and must withstand temperatures up to 250 °F.
For the complete installation procedure, see the installation manual provided with the kit. You can also download this manual at www.osburn-mfg.com.

ENGLISH

*The EPA standard states that it is necessary to perform certification testing with any ventilation that is likely to alter the units’ performance. For this reason, SBI has tested the effects of the forced air kit on the emissions of fine particles. Due to the design of our appliance and more specifically to the temperature sensor that is installed to control stops and starts, the forced art kit does not affect the emission results. In fact, this option promotes the recovery of excess heat to later redistribute it to other rooms. During our testing, it was noted that the convection blowers underneath the firebox had more of an effect on the fine particles emission due to the air being directed onto the firebox thus cooling the unit. However, this appliance has already been tested for emission

Page 60

Installation and Operation Manual – Everest II

APPENDIX 6: OPTIONAL FIRESCREEN INSTALLATION
A firescreen door can be installed on the fireplace. For more details, refer to the installation manual supplied with the firescreen. Warning: Never leave the fireplace unattended while in use with the firescreen. 1. Open the doors.
2. Hold the firescreen and bring it close to the door opening.

ENGLISH

3. Lean the upper part of the firescreen against the top door opening making sure to insert the top firescreen bracket behind the primary air deflector.
4. Lift the firescreen upwards and push the bottom part towards the fireplace then let the firescreen rest on the bottom of the door opening.
Installation and Operation Manual – Everest II

Page 61

ENGLISH

APPENDIX 7: REFRACTORY PANELS REMOVAL

1. Remove the floor refractory panels (E).

2. Using a power driver, remove the refractory panel brackets (G) and the side refractory panels (I).

3. Remove the back refractory panel (F).

Page 62

Installation and Operation Manual – Everest II

ENGLISH

APPENDIX 8: SECONDARY AIR TUBES AND BAFFLE INSTALLATION
1. Starting with the rear tube, lean and insert the right end of the secondary air tube into the rear right channel hole. Then lift and insert the left end of the tube into the rear left channel.
2. Align the notch in the left end of the tube with the key of the left air channel hole. Using a «Wise grip» hold the tube and lock it in place by turning the tube as shown. Make sure the notch reaches the end of the key way.
3. Repeat for center back tube. 4. Put the baffle in place. 5. Repeat steps 1 and 2 for the two front
tubes. 6. To remove the tubes use the above steps in
reverse order.
Note that secondary air tubes (A) can be replaced without removing the baffle board (B).

Installation and Operation Manual – Everest II

Page 63

APPENDIX 9: BLOWER REPLACEMENT

To facilitate the blower replacement, it is recommended to remove the faceplate first. Refer to the faceplate installation manual for more details.

1. Take off the faceplate

2. Cut the ty-rap. Lift the blower (A) located under the firebox towards the back. Turn 90° to pull out.

ENGLISH

3. Unplug the wires and unplug the blower’s electric wires (P) and (Q).

4. Repeat the steps in reverse order to reinstall the blower. Page 64

Installation and Operation Manual – Everest II

ENGLISH

Blower Connection The wiring should be done by a qualified electrician. Connect the wires from the power outlet to the terminal block, making sure that the white wire matches the white wire on the terminal. Connect the black wire with the black wire of the terminal block. The ground (green or skinned wire) must be attached to the fireplace metal frame.
AUTO MANUEL

Installation and Operation Manual – Everest II

Page 65

APPENDIX 10: EXPLODED DIAGRAM AND PARTS LIST

ENGLISH

58
57 56
55 51

54 53
52 47

59
60 61

50 36
35
33 32 31

49 37

48 45
44

34

27 26 24

23

28

25

22

29 30
67

66

62

46 43

42

41

40

69

63

39

38

64 68
65

23

20

21
19 19

10

17

11

9 12

18 16
17

11 10
9
8

13 14

76 5

4
3 1

15 6
2

Page 66

Installation and Operation Manual – Everest II

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your unit, please provide the model number and the serial number. We reserve the right to change parts due to technology upgrades or availability. Contact an authorized dealer to obtain any of these parts. Never use substitute materials. Use of non-approved parts can result in poor performance and safety hazards.

Item 1 OA10622 1 OA10620 2 30252 3 30025 4 30187 5 30898 6 SE36580 7 SE70409

8 SE24195 9 30101 10 AC06500 11 30877 12 40030 13 30124 14 30450 15 SE70410 16 SE24196 17 SE70001 18 AC06400 19 PL70000 20 SE63024 21 SE70479 22 SE70477 23 30143 24 PL70439 25 PL70425 26 30154 27 30506 28 PL70426 29 30556 30 SE70440 31 30220 32 PL70104 33 PL63954 34 PL70463

Description

Qty

BRUSHED NICKEL DOOR OVERLAY

1

BLACK DOOR OVERLAY

1

MECHANICAL SCREW 1/4-20 X 5/16″ BUTTONHEAD HEX DEEP #5/32 18-8 BLACK 8

1/4-20 X 1/2″ PAN-HEAD QUADREX BLACK SCREW

2

STAINLESS WASHER ID 17/64″ X OD 1/2″

2

ROUND WOODEN BLACK HANDLE DULL BLACK FINISH

2

LATCH KIT

2

LEFT HANDLE AND LATCH KIT

1

LEFT DOOR ASSEMBLY WITH GASKET AND HANDLE

1

SPRING TENSION PIN 5/32″Ø X 1 1/2″L

2

SILICONE AND 5/8″ X 8′ BLACK DOOR GASKET KIT

2

HINGE PIN 1/4″Ø X 2-1/2″L

2

6 mm GASKET

3

SCREW #8 – 32 X 5/16” TRUSS QUADREX ZINC

1

OSBURN DOOR LOGO

1

RIGHT HANDLE AND LATCH KIT

1

RIGHT DOOR ASSEMBLY WITH GASKET AND HANDLE

1

REPLACEMENT GLASS WITH GASKET 10 5/16” X 12 7/16”

2

3/4″ (FLAT) X 6′ BLACK SELF-ADHESIVE GLASS GASKET

1

GLASS RETAINER TRIM

4

GLASS RETAINER WITH SCREWS KIT (10 UNITS)

1

RIGHT CHARIOT ASSEMBLY

1

LEFT CHARIOT ASSEMBLY

1

SOCKET SET SCREW #10-32 X 1/2″

2

RIGHT PLUG FACEPLATE

1

LEFT PLUG FACEPLATE

1

BLACK SCREW #10 X 5/8″ QUADREX #2 TYPE A

2

SCREW PAN TORX TYPE F 1/4-20 X 1″ BLACK

4

ASH TRAY

1

AIR CONTROL FINISHING TIP

1

AIR CONTROL ASSEMBLY

1

FLANGED LOCKNUT 1/4-20

2

AIR INLET

2

4″ ADAPTOR

1

SIDE STAND-OFF

4

Item

Description

Qty

35 PL70424

SIDE REAR STAND-OFF

2

36 PL70452

REAR STAND-OFF

2

37 PL70453

TOP STAND-OFF

2

38 44207

DOUBLE CAGE BLOWER 176 CFM (CLASS H)

1

39 44028

CERAMIC THERMODISC F110-20F

1

40 44080

RHEOSTAT WITHOUT NUT (MODEL KBMS-13BV)

1

41 PL70113

TERMINAL COVER

1

42 44091

ROCKER SWITCH 2 POSITION MSR-8

1

43 44085

RHEOSTAT KNOB

1

44 44087

RHEOSTAT NUT

1

45 44131

SPEED CONTROL (2.5 A)

1

46 44121

FORCED AIR KIT BLOWER 6” – 2.4A

1

47 VA4460

FORCED AIR KIT

1

48 22354

RIGHT FLOOR REFRACTORY

1

49 22353

LEFT FLOOR REFRACTORY

1

50 22355

LEFT REFRACTORY

1

51 22357

REAR REFRACTORY

1

52 22356

RIGHT REFRACTORY

1

53 PL70107

FRONT SECONDARY AIR TUBE

1

54 PL70407

CENTER FRONT SECONDARY AIR TUBE

1

55 PL70408

CENTER SECONDARY AIR TUBE

1

56 PL70108

REAR CENTER SECONDARY AIR TUBE

1

57 PL70109

REAR SECONDARY AIR TUBE

1

58 SE36511

RIGID CERAMIC BAFFLE KIT 2000 SERIE (3 PCES)

1

59 AC01375

HOT AIR GRAVITY KIT – TRADITIONAL

1

60 30640

GALVANISED BOX FOR HOT AIR GRAVITY KIT 8″

2

61 30540

HOT AIR GRAVITY KIT GRILL

2

62 30767

SPRING 1/2”Ø OUTSIDE X 8”L

2

63 30472

SPRING 1/2” OUTSIDE Ø X 3”L

2

64 OA10619

TRADITIONAL STYLE FACEPLATE

1

65 AC01379

FIRESCREEN DOOR

1

66 AC05959

METALLIC BLACK STOVE PAINT – 342 g (12oz) AEROSOL

1

67 SE46186

EVEREST II INSTRUCTION MANUAL KIT

1

68 OA10621

MODERN FACEPLATE

1

OSBURN LIMITED LIFETIME WARRANTY
OSBURN LIMITED LIFETIME WARRANTY

The warranty of the manufacturer extends only to the original retail purchaser and is not transferable. This warranty covers brand new products only, which have not been altered, modified nor repaired since shipment from factory. Proof of purchase (dated bill of sale), model name and serial number must be supplied when making any warranty claim to your OSBURN dealer.
This warranty applies to normal residential use only. This warranty is void if the unit is used to burn material other than cordwood (for which the unit is not certified by EPA) and void if not operated according to the owner’s manual. Damages caused by misuse, abuse, improper installation, lack of maintenance, over firing, negligence or accident during transportation, power failures, downdrafts, venting problems or under-estimated heating area are not covered by this warranty. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.
This warranty does not cover any scratch, corrosion, distortion, or discoloration. Any defect or damage caused by the use of unauthorized or other than original parts voids this warranty. An authorized qualified technician must perform the installation in accordance with the instructions supplied with this product and all local and national building codes. Any service call related to an improper installation is not covered by this warranty.
The manufacturer may require that defective products be returned or that digital pictures be provided to support the claim. Returned products are to be shipped prepaid to the manufacturer for investigation. Transportation fees to ship the product back to the purchaser will be paid by the manufacturer. Repair work covered by the warranty, executed at the purchaser’s domicile by an authorized qualified technician requires the prior approval of the manufacturer. All parts and labour costs covered by this warranty are limited according to the table below.
The manufacturer, at its discretion, may decide to repair or replace any part or unit after inspection and investigation of the defect. The manufacturer may, at its discretion, fully discharge all obligations with respect to this warranty by refunding the wholesale price of any warranted but defective parts. The manufacturer shall, in no event, be responsible for any uncommon, indirect, consequential damages of any nature, which are in excess of the original purchase price of the product. A one-time replacement limit applies to all parts benefiting from lifetime coverage. This warranty applies to products purchased after June 1st, 2015.

DESCRIPTION

WARRANTY APPLICATION*

PARTS

LABOUR

Combustion chamber (welds only) and cast iron door frame Ceramic glass, plating (manufacturing defect), and convector air-mate Surrounds, heat shields, ash drawer, steel legs, pedestal, trims (aluminum extrusions), vermiculite, C-Cast or equivalent baffle, secondary air tubes, removable stainless steel combustion chamber, deflectors, and supports Handle assembly, glass retainers and air control mechanism Removable carbon steel combustion chamber components Standard and optional blower, heat sensors, switches, rheostat, wiring, and electronics Paint (peeling), gaskets, insulation, ceramic fiber blankets, refractory bricks (fireplace only**), and other options All parts replaced under the warranty
Subject to limitations above
Picture required ***limited to one replacement

Lifetime Lifetime
7 years***
5 years 5 years 2 years
1 year 90 days

5 years N/A
N/A
3 years N/A 1 year
N/A N/A

Labour cost and repair work to the account of the manufacturer are based on a predetermined rate schedule and must not exceed the wholesale price of the replacement part.
Shall your unit or a components be defective, contact immediately your OSBURN dealer. To accelerate processing of your warranty claim, make sure to have on hand the following information when calling:

· Your name, address and telephone number · Bill of sale and dealer’s name · Installation configuration

· Serial number and model name as indicated on the nameplate fixed to the back of your unit
· Nature of the defect and any relevant information

Before shipping your unit or defective component to our plant, you must obtain an Authorization Number from your OSBURN dealer. Any merchandise shipped to our plant without authorization will be refused automatically and returned to sender.

Wood_Revision: June 2021

This document is available for free download on the manufacturer’s website. It is a copyrighted document. Resale is strictly prohibited. The manufacturer may update this document from time to time and cannot be responsible for problems, injuries, or damages arising out of the use of information contained in any document obtained from unauthorized sources.

Stove Builder International inc. 250, De Copenhague street, St-Augustin-de- Desmaures (Québec), Canada G3A 2H3 1-877-356-6663 www.osburn-mfg.com/en tech@sbi-international.com

References