MICROMED MDIII Electrosurgical Unit User Manual

June 15, 2024
MICROMED

MICROMED MDIII Electrosurgical Unit

MICROMED-MDIII-Electrosurgical-Unit-product

Specifications

  • Product Name: HF-Electrosurgical Unit MD3
  • Suitable for: Surgical, veterinary, dermatological, dental, gynecological, and cosmetical applications
  • Therapy Modes: Monopolar, nonterminal, and bipolar
  • Number of Cut Modes: 2 (Smooth Cut and Encrusted Cut)
  • Number of Coagulation Modes: 3 (Contact Coagulation, Spray Coagulation, and Bipolar Coagulation)
  • Maximum Output Power: C ut 1 – 80 Watt, Cut 2 – 30 Watt, Coagulation 1 – 70 Watt, Coagulation 2 – 50 Watt

Product Description

The HF-Electrosurgical Unit MD3 is the ideal device for smaller surgical operations. Suitable for diverse ranges of application like surgical-, veterinary-, dermatological-, dental-, gynecological- and cosmetically applications. This device can be used for monopolar, nonterminal and bipolar therapies. A neutral electrode is necessary for the monopolar method. However the patient has to be carried in connection with the ground.

The unit is equipped with 2 cut-modes and 3 coagulation-modes

MICROMED-MDIII-Electrosurgical-Unit-01 The micro switch is used to reduce the maximum output power of the cut function 80 Watt down to 30 Watt when the bipolar mode ist activated, resp. down to 50 Watt in the coagulatin function. The reduction of output power is an advantage, because the range of power can be adjusted more exactly.
The device is equipped with a special interface for an electrode handle with push button or a handle wihout
push button. In this case the activison has to be done by a foot switch. The bipolar output can also be activated by a foot switch.
The neutral electrode interface is used to connect the small rubber neutral electrode or an electrode cable in connection with an one-piece/two-piece single use neutral electrode.

Product liability
The firm Micromed declares to take responsibility for the safety of Unit MD3 if the user keeps to the following points:

  • Fresh engagements and acts of fixing should be done by Micromed only.
  • The electrical installation of the room in which the unit is used, fulfills the specification of VDE 0107 or IEC 60364-710
  • The unit must be used after the annotations and rules of the user manual.

Environmental relevantly indications

  • Packaging
  • The complete packaging will be taken back by Micromed. If you do not want to make use of hereof, you can dispose of the packaging with the regular household bin.

Disposal of the device

  • When producing the device we used sparse composites. This way of production allows a high degree of recycling. We offer you to take back the old device and remove it properly.
  • We would like to point out that the conditions of the Directives for Electronic Scrap must be adhered to when removing the device.

Incoming materials inspection

Damage in transit

  • Please check after you received the unit immediately if there is any damage in transit or any defects.

Claim for damages

  • Claim for damages is valid, if the dealer or the firm Micromed are inforemed immediately. A protocoll of all damages has to be done without delay. Please send this protocoll to the dealer or directly to Micromed ,in order to work on the settlement of damages.

Back dispatch

  • The back dispatch of the unit is done if possible inside the original package to Micromed . Please add the following accompanying documents: Name and address of the despatcher, model number and device number, description

First Startup

  • The operator can only start using the device if the equipment was checked by an acceptance test at the operating place and the responsible person who uses that equipment was instructed in its handling. The electronic connection may only be connected by the supplied cable or by a qualitative comparable cable. The outlet must be a protective contact outlet. It is absolutely important that cable and outlet do have a protective contact.

Hints for safe application

  • Non observance of the descried hints of wrong handling, can cause incidents combined with serious injuries.
  • The HF-Electrosurgical unit is not determined for operations in areas which are in danger of explosions.
  • The use of flammable fluids and gases has to be avoided, or taken possessions that those fluids / gases cannot be inflamed by the high frequency voltage.
  • You can use this HF-Unit for monopolar and nonterminal therapies.
  • The temporary unused active electrode has to be place down far from the patient. Any contact to close cables must be avoided.
  • The performance setting must be adjusted as low as possible for the respective application.
  •  Skin-to-Skin touching, e.g. between must be adjusted as low as possible for the respective application.
  • n case of a malfunction exists the danger of an increased transference of HF-performance. Caution! Endangering due to burnings

Patients with pacemakers

The ambulant therapy of patients with pacemakers may not be executed in connection with HF-Current. Please ask every patient before the therapy with HF-Current, if he wears a pacemaker. Patients with pacemakers are endangered by HF-Cureent, because the function of the pacemaker can be jammed or even completely damaged.

Placement of patients for monoterminal operations

  • The HF-Unit MD3 is a so called “BF-Type”, that means nonterminal applications are possible.
  • The therapeutic bensch on which the patient is lying on, must be electricially grounded. The neutral electrode must be always plugged in and placed on the patient’s body, otherwise the unit will deliver no power. The restiance values between patient and therapeutic bench must be the
  • same on every spot. If there is the slightest touch between and ground potential leading metal parts, e.g. at the bench on which he is lying, there is the danger of skinn irritation and burnings.
  • Because of that, it is very important to check before every therapy, that there is no direct contact to ground potential.

Placement of the patient for monopolar operations

  • The patient must be placed on the bench without any ground potential. The neutral electrode is necessary for electrical connection to the patient, because it allows a backflow of electrical current out of the human body.
  • The neutral electrode must be placed with its entire surface as close as possible to the treatment area. Furthermore it must be layed on the patient’s body absolutely reliable, otherwise the danger of skin irritation and burning exists.
  • The neutral electrode shouldn’t be put on apophysis, metal-implants, scared skin, massive cells of fett and on spots where fluids can flow together.
  • Do not use electrode gel.
  • The application surface must be clean, dry, free of hair growth and without any injuries.
  • The cables shouldn’t be in touch wiht the patient, nor have contact to any other cables.

Neutral electrode
The neutral electode must be put on the skin perfectly with its entire surface. We recommend the hips or the upper arms.

MICROMED-MDIII-Electrosurgical-Unit-02

  • An alert sound and a red signal will appear, if no plug of an neutral electrode is plugged in.
  • The neutral electrode shouldn’t be put on apophysis, metal-implants, scared skin, massive cells of fett and on spots where fluids can flow together.
  • The application area must be dry and clean, and should not include a big crop of hair.
  • The connection cable of the neutral electrode must not touch the patient or any different cables.
  • The superveillance electrodes from connected diagnose units must be placed as far as possible to the neutral electrode and active electrode.
  •  If there should be a power drain which is to low, which doesn’t match with the adjusted performance, please check the operation field and all other connecting cables, incl. special accessories.
  • The neutral electrode should not be disconnected from the patient by pulling the cable.
  • Always set the power output for the respective purpose as low as possible.

Medical range of application
This HF-Unit was conceived for the use up to 80 Watt power output, in the following disciplines:

  • General Surgery
  • Pediatric Surgery
  • Dental Surgery
  • Dermatology
  • Container Surgery
  • Gynaecology
  • HNO-, Jaw- and Face Surgery
  • Cosmetic applications
  • Microsurgery
  • Plastic Surgery
  • Accident Surgery
  • Veterinerian Surgery

Function of HF-Units
The HF-Unit produces thermic effects. The highfrequent electrical current heats the histoblasts. The tissue is beeing cut with more than 100°C., thereby all intra,- and extracellularly fluids and all cell substances get coagulated thermically. This stops all possible bleedings.
In the HF-Surgery there is a distinction between two types of electrical current: “Cut” and “Coagulation”. Because of the hight current density on the active electrode, it is possible to cut/coagulate the tissue. The current passes through the human body , leaves the body through the neutral electrode, and finally back to the HF-Unit.

Hints for operating

MICROMED-MDIII-Electrosurgical-Unit-03

  1. Micro-Button to reduce power
  2. Cut 1
  3. Cut 2
  4. Pilot lamp for Cut
  5. Coagulation 1
  6. Coagulation 2
  7. Pilot lamp for Coagulation
  8. Knop to adjust performance
  9. Power-Button On/Off
  10. Connection plug for neutral electrode
  11. Connection plug for electrode handle Connection plug for foot button
  12. Connection plug bipolar
  13. Pilot lamp for Bipolar Coagulation Bipolar Coagulation
  14. Type plate
  15. Mains fuse,
  16. 1,0 Ampere Power plug
  17. Potential balance

MICROMED-MDIII-Electrosurgical-Unit-04

Description of user elements

  • Cut1 creates a smooth cut with less sparkles and less encrustations.

  • Cut2 creates an encrusted cut with many sparkles. Suitable for very bloody tissue or fett cells.

  • Contact-Coagulation creates a powerless modulated current for the contact-coagulation.

  • Spray-Coagulation (Fulguration) creates a powerful modulated current for spray-coagulation or fulguration.

  • Bipolar-Coagulation This kind of coagulaton is working without use of a neutral electrode.

  • In this mode a low power output to the operating area allows a safe work.

  • Micro Switch The micro switch reduces intensely the power output. That hepls to adjust the lower performance range much easier.

  • Connector (monopolar) for electrode handles: suitable for handles with one/none button.
    Connector (bipolar) for forceps and bipolar instruments. Activation by foot switch.

  • Connector neutral electrode
    Connector foot swich to activate monopolar and bipolar jack.

  • Defibrilator safe for HF-Units in class BF.

    • Capacitive earth connection between HF-Unit and ground.
    • Caution! Read user manual!
  • Caution! High Voltage output

Start Up

  • The electrical connection of this unit may only be connected with the supplied mains connection cable to a socket which was correctly installed according to VDE 0107 resp. IEC 60364-710. Before using this machine the first time, the given mains voltage on the type plate has to match
  • with the voltage of your electrical system.
  • The HF-Unit is to activate by pushing the green power switch (9) with the inscription 01. From now on the green switch is flashing, and the user can choose one of the five types of current. The Micro-button must be pushed , to reduce the power. If you push this button, the micro-switch is
  • flashing green, and the maximum power output is reduced. That allows to adjust the power very precisely.
  • Caution, when the micro function is turned off, power output will increase enormously, for example from 30 Watt to 70 resp. 80 Watt with level 10. Because of that performance must be decreased immediately when micromodel is turned off.
  • The power output can only be activated when the one-piece neutral electrode ist plugged in, otherwise an alert will resound and the red signal will be blinking.

Disturbing emission of HF-Units

  • The HF-Units produce logically highfrequent and magnetic fields, which are sent out through the cables and can disturb electronic units around the operation field.

Guarantee

  • From the very first day on, beginning at the day of the delivery , we grant a guarantee of 24 months.

Restoration

  • The device contains two fuses that resides inside the power entry module on the backside.
  • To replace those fuses, the power plug must be disconnected from the socket. The fuse holder must be unlocked on both sides, afterwards the fuse holder can be pulled out. Check both fuses, replace the defective one.
  • The fixing of asserted defects inside the HF-Unit must be done by Micro med.

 Specifications

  • Power Supply Line
  • Power Supply Line (see type plate)
  • Mains frequency
  • Power consumption
  • Mains fuse 230V
  • HF-Output max.
  • Cut I max.
  • Cut II max.
  • Contact-Coagulation
  • Spray-Coagulation
  • Bipolar Coagulation
  • HF-Output Micro
  • Cut I max.
  • Cut II max.
  • Contact-Coagulation
  • Spray-Coagulation
  • Bipolar Coagulation

General Specifications

  • Nominal Frequency
  • Safety Class
  • Type
  • Classification MPG
  • Ratio encumbrunce time/break time
  • Weight
  • Breadth
  • Height
  • Depth

Transport- and storage conditions

  • Ambient temperature: -20°C until +70°C

  • Relative humidity: 10% until 100%

  • Air pressure: 500 until 1060hPa

  • 110-120/220-240 V~

  • 50-60 Hz

  • 180 VA

  • 1 Ampere, time-delayed, 2 x

  • 80 Watt, 400 Ohm 70
    Watt,1000 Ohm 70

  • Watt, 400 Ohm 5

  • Watt,1000 Ohm 70

  • Watt 125 Ohm

  • 30 Watt, 400 Ohm 30

  • Watt,1000 Ohm 30

  • Watt, 400 Ohm 20

  • Watt,1000 Ohm 50

  • Watt 125 Ohm

700 kHz

  • I
  • BF
  • II b
  • 10 / 30 sec.
  • 5,5 kg
  • 270 mm
  • 125 mm
  • 260 mm

Accessory

The HF-Unit may only be used with original Micromed accessories. The accessory must be examined before each operation. Damaged accessory can cause unwanted burnings.

  • 100-001-016 MicroPen, Handle without buttons, for 1,6mm electrodes
  • 100-001-040 MicroPen, Handle without buttons, for 4,0mm electrodes
  • 100-101-016 MicroPen, Handle with one button, for 1,6mm electrodes
  • 100-101-040 MicroPen, Handle with one button, for 4,0mm electrodes
  • 101-020-200 Connecting cable MicroPen, length 2m
  • 101-020-300 Connecting cable MicroPen, length 3m
  • 101-020-400 Connecting cable MicroPen, length 4m
  • 101-020-500 Connecting cable MicroPen, length 5m
  • 120-XXX-XXX Electrode Ø 4,0 mm, please see HF-Catalogue Micromed
  • 121-XXX-XXX Electrode Ø 1,6 mm, please see HF-Catalogue Micromed
  • 122-XXX-XXX Electrode Ø 4,0 mm, please see HF-Catalogue Micromed
  • 110-103-400 Rubber neutral electrode with 4m connecting cable
  • 110-101-075 Rubber band, punched, length 75cm, (material contains latex)
  • 110-101-100 Rubber band, punched, length 100cm, (material contains latex)
  • 110-102-000 Knop for rubber band
  • 152-811-010 Foot switch
  • 129-001-001 Suitcase HF-Unit MD3
  • 140-XXX-XXX Bipolar Forceps
  • 151-003-001 Accessory Dermatology
  • 151-003-002 Accessory Set Cosmetic Bipolar
  • 151-003-003 Accessory Surgery
  • 151-003-004 Accessory Set Dental
  • 151-003-006 Monopolar ENT Accessory Set
  • 151-003-007 Bipolar ENT Accessory Set

Waste disposal

The HF-Electrosurgical units contain no electronic parts and materials which are more harmful to the environment compared to the usual extent. The construction is built up in a way that facilitates the recycling of different materials like iron, synthetic parts and electronics.

 Disinfection

HF-Unit
The disinfection of this HF-Unit can be done by the usual wipe- and spray disinfectant. Keep to manufacturer data.

HF-Accessory

  • Cleaning, disinfection and sterilization of HF-Accessories can also be done with the same chemical disinfectant. The statement of the pertaining manufacturers must paid attention.
  • The mechanical cleaning can be done up to 95°C.
  •  The electrode handle MicroPen, connecting cable and the electrodes can be sterilized up to 134°C.
  • Sterilization with hot air is not permitted.

Safety Controls

The safety-relevant controls for this HF-Unit must be done at least every 24 months. The tests have to be done by authorized personnel or directly by Micromed. The following issues must be checke

  • The resultes from the safety controls have to be documented in the equipment book.
  • Visual Control HF-Unit and accessories
  • The readability of all-safety relevant epigrams must be checked.
  • The fuses must be checked concerning rated current and fusion character.
  • Constant energy transference corresponds to the increasing values from the performance setting at the rotary knob.
  • The maximum transfered performance must be compared f or all four current types, with or without microswitch to the scheduled value. If necessary the power output must be adjusted once again.
  • The test must be processed according to EN IEC 60601-1.

Certificates

conformable to 93/42/EWG

 Charts of output power

The upper performance curve describes level 10, the inferior curve the maximum performance at level 5.

MICROMED-MDIII-Electrosurgical-Unit-19

 Charts of output power with Micro mode

MICROMED-MDIII-Electrosurgical-Unit-20

Additional Charts. Additional Charts

The following charts show the relating power output as a function of the setting concerning a determined resistance of 500 Ohm (Cut1, Coagulation1) resp. 1000 Ohm (Cut2, Coagulation2).

MICROMED-MDIII-Electrosurgical-Unit-21

 Information about electromagnetic compatibility (EMC)

MICROMED-MDIII-Electrosurgical-Unit-22

999-004-001 Printed in Germany 11.10
© Copyright by Micromed Medizintechnik GmbH

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals