valinge Resilient Flooring User Manual

June 15, 2024
valinge

valinge Resilient Flooring

Product Information

Specifications

  • Product Name: 5Gi – Herringbone
  • Type: LVT (Luxury Vinyl Tile)
  • Installation Method: Click System

Product Usage Instructions

Important Information
Before starting the installation, please note the following:

  • Do not install the product in temperatures exceeding 35 degrees Celsius.
  • Any damages or dents can be repaired using melting wax or a similar product.
  • Use office chair mats or 5cm wide wheels that do not discolor the floor (avoid rubber wheels).

Build Starting Triangles

  1. Take B-strips and A-strips and position them as shown in the diagram.
  2. The number of strips used will vary depending on their width.
  3. Install the strips precisely and in the order indicated by the numbers on the strips.
  4. Check the joints between the strips after adding each strip. Ensure there are no protruding edges.
  5. Cut the triangle according to the indicated red line. It may be useful to dismantle the triangle before sawing, depending on the type of saw used.
  6. The excess material below the line should be saved for the last row installation.

Measuring the Room
Before starting the installation, measure the room and define the wall from where you intend to start.

Calculating the Number of Triangles

  1. Measure the distance between the two straight lines originating from the corners of the strips.
  2. Divide this number by two to get the X measurement.
  3. Use the formula provided to calculate the number of needed starting triangles. Round up to the next full number.

Start Installation
Follow these steps to start the installation:

  1. Draw the installation line starting from the center of the room. Parallel offset the line using the X measurement as the distance.
  2. Lay out the triangles with their long side towards the starting wall. Align the center triangle top with the installation line. Ensure the underlay material is installed beforehand and the installation line remains visible.
  3. Use expansion wedges for the expansion gap.
  4. Cut the distances C-D and E-F from the remaining triangle(s) and position them accordingly.

Further Installation of Pattern
To continue installing the pattern, follow these steps:

  1. Lock the boards into one another using the 5Gi system. Use a rubber hammer to connect a new board.
  2. Measure the straightness of the installation along the green line.
  3. Use a rubber hammer to connect the short side of the boards. Start in the corner and work towards the end of the board.
  4. Install A-strips to connect all triangles. Check the joints between the A-strip and the triangle carefully. Ensure there are no protruding edges.

Herringbone Installation Instructions for Resilient Flooring

Important information

  • The flooring must be acclimated a minimum of 24 to 48 hours prior to installation in the room where the installation will take place
  • In larger rooms, the flooring must be installed in smaller sections with expansion joints.
  • The distance to walls and other permanent pieces of construction elements (such as pillars and kitchen islands) should be approximately 5 mm
  • Never install very heavy pieces of furniture such as kitchen islands/cabinets on top of the flooring
  • The indoor climate should have a temperature between 15-23 ° C and relative air humidity between 30-60%.
  • Always follow the floor manufacturers’ requirements and specifications regarding subfloor preparation.

Build starting triangles

  1. Take B-strips and A-strips and position them as shown above.
    Note! The number of strips varies depending on the width of the strips used.

  2. Install the strips precisely and in the order indicated by the numbers on the strips. Carefully check the joints between the strips after every strip that is added.
    Note! No protruding edge may be felt!

  3. Cut the triangle according to the indicated red line. Depending on the kind of saw you use, it may be useful to dismantle the triangle before sawing.
    Note! The excess (below the line) is to be saved for the last-row installation.

Measuring the room
Define the wall from where you intend to start the installation. Mark out the center of the room.

Calculating the number of triangles

  1. Measure the distance between the two straight lines, originating from the corners of the strips.
  2. Divide this number by two, and get the X measurement.
  3. Drawing the installation line Start from the center of the room. Parallel offset the line using the X measurement as distance.
  4. Calculate the number of needed starting triangles with the formula to the left. Note! Round up to the next full number.

Start installation

  • Lay out the triangles with their long side towards the starting wall.
  • Align the center triangle top with the installation line.
  • Make sure the underlay material is installed beforehand and the installation line remains visible.

Note! Use expansion wedges for the expansion gap.

Finalising the start row
Now cut the distances C-D and E-F from the remaining triangle(s), and position them.

Note! In case you have calculated and built an uneven number of triangles, leave the outer two triangles aside. For the case that you have built an even number of triangles, lay one aside.

Further installation of pattern

  1. The boards need to be locked into one another, using the 5Gi system. To connect a new board you have to use a rubber hammer.

  2. Use a rubber hammer and slightly knock at the 5Gi system to connect the short side. Start in the corner and work towards the end of the board.

  3. Install A-strips to connect all triangles. The joints between the A-strip and the triangle need to be checked very carefully. No protruding edge may be felt!
    Cut the most left piece to fit into the room, considering an expansion gap. Measure the straightness of the installation along the green line. Repeat that measuring with the straightedge progressively throughout the installation. Deviations need to be corrected, should they occur (see schematics below).

  4. Now install B- B-strips and cut the right piece to size.

**Last row installation

**

This alternating installation of A-strips and B-strips continues throughout the whole room. It is important to check frequently that:

  • all expansion wedges remain in their position.
  • all joints are closed and the strips are locked into one another.
  • you follow the installation line.
  • the tops of the strips in one line remain straight and perpendicular to the installation line

Note! Measure approximately every fifth row.

Excess pieces from starting triangles:
Dismantle the excess material from the starting triangles. Use it to close the open gaps to the finishing wall. Use the leftover from strips 1, 2 etc. consecutively and cut to size if necessary.

Installation around radiator/heating pipes

  • Drill holes two times larger than the diameter of the pipes. Remove a piece of the strip with a utility knife or a saw. Put the strip on one side of the pipes and the removed piece on the other side.

When angling is not possible

  • Remove the locking element according to the picture. Use an applicable glue to connect the strips. Press- place wedges between the glued strip and the wall.

www.5gfolddown.com

Copyright © 2019 Välinge Innovation

Frequently Asked Questions

Can I install the 5Gi - Herringbone product in high-temperature areas?

No, it is not recommended to install the product in temperatures exceeding 35 degrees Celsius.

How can damages or dents on the floor be repaired?

Damages or dents can be repaired using melting wax or a similar product.

What type of wheels should I use for my office chair to prevent floor discoloration?

Use office chair mats or 5cm wide wheels that do not have rubber material.

How do I connect the boards using the 5Gi system?

To connect the boards, use a rubber hammer and follow the instructions provided in the manual.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals