KitchenAid W11671285A Built In Gas Cooktop Installation Guide
- June 15, 2024
- KitchenAid
Table of Contents
KitchenAid W11671285A Built In Gas Cooktop
Product Information
Specifications
- Appliance: 30 Electric Single Wall Oven
- Width of Cooktop (A): 37 in / 93.6 cm
- Length of Cooktop (B): 21 5/8 in / 54.9 cm
- Width of Burner Box (C): 34 1/2 in / 87.6 cm
- Length of Burner Box (D): 19 1/4 in / 49 cm
- Height of Burner Box (E): 3 3/4 in / 9.6 cm
- Height of Burner Box (including Gas Inlet) (F): 4 1/4 in / 10.9 cm
- Width to Gas Inlet from edge (G): 1 1/2 in / 3.8 cm
- Length to Gas Inlet from edge (H): 4 3/8 in / 11 cm
Product Usage Instructions
Location Requirements
Before installing the cooktop, please observe the following:
- Ensure that the cooktop is installed away from strong draft areas, such as windows, doors, and heating vents or fans.
- All openings in the wall or floor where the cooktop is to be installed must be sealed.
Cabinet Dimensions
When installing the cooktop, please follow these guidelines:
- Use the provided cabinet opening dimensions as the minimum clearances.
- Ensure that there is a grounded electrical supply available. Refer to the Electrical Requirements section for more details.
- Make sure there is a proper gas supply connection available. Refer to the Gas Supply Requirements section for more details.
- The cooktop is designed to hang from the countertop by its side or rear flanges.
- Ensure that the gas and electric supply is accessible without requiring the removal of the cooktop.
- Provide a cutout in the right rear corner of the enclosure to provide clearance for the gas inlet, and power supply cord, and to allow the rating label to be visible.
- Consult with your builder or cabinet supplier to ensure that the materials used will not discolour, delaminate, or sustain other damage.
Mobile Home – Additional Installation Requirements
If installing the cooktop in a mobile home, please follow these additional
requirements:
- Conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 or use the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A, or local codes.
- In Canada, conform with the current standards CAN/CSA-Z240.1, latest edition, or with local codes.
FAQ
-
Q: Can I install a range hood or microwave hood combination above the cooktop?
A: Yes, you can install a range hood or microwave hood combination above the cooktop. Please follow the installation instructions for dimensional clearances above the cooktop surface provided by the range hood or microwave hood combination. -
Q: Where is the model/serial/rating plate located?
A: The model/serial/rating plate is located on the underside of the cooktop base. -
Q: Are there any specific electrical and gas supply requirements?
A: Yes, a grounded electrical supply is required. Please refer to the Electrical Requirements section for more details. Additionally, a proper gas supply connection must be available. Refer to the Gas Supply Requirements section for more details. -
Q: How should I hang the cooktop?
A: The cooktop is designed to hang from the countertop by its side or rear flanges. -
Q: Can I install the cooktop in a mobile home?
A: Yes, you can install the cooktop in a mobile home. Please follow the additional installation requirements specified for mobile homes.
APPLIANCE
APPLIANCE: | 30″ ELECTRIC SINGLE WALL OVEN |
---|---|
Units | |
A | Width of Cooktop |
B | Length of Cooktop |
C | Width of Burner Box |
D | Length of Burner Box |
E | Height of Burner Box |
F | Height of Burner Box (including Gas Inlet (Manifold)) |
G | Width to Gas Inlet (Manifold) from edge |
H | Length to Gas Inlet (Manifold) from edge |
OVERVIEW
IMPORTANT: Dimensional specifications are provided for planning purposes only. Do not make any cutouts based on this information. Refer to the Owner’s Manual before selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances. Do not obstruct flow of combustion and ventilation air.
- It is the installer’s responsibility to comply with installation clearances specified on the model/serial/rating plate. The model/serial/rating plate is located on the underside of the cooktop base.
- The cooktop should be installed in a location away from strong draft areas, such as windows, doors, and strong heating vents or fans.
- All openings in the wall or floor where cooktop is to be installed must be sealed.
- Cabinet opening dimensions that are shown must be used. Given dimensions are minimum clearances.
- Grounded electrical supply is required. See “Electrical Requirements” section. Proper gas supply connection must be available. See “Gas Supply Requirements” section.
- The cooktop is designed to hang from the countertop by its side or rear flanges.
- The gas and electric supply should be located as shown in “Cabinet Dimensions” section so that they are accessible without requiring removal of the cooktop.
- Provide cutout in right rear corner of cutout enclosure as shown to provide clearance for gas inlet, power supply cord, and to allow the rating label to be visible.
IMPORTANT: To avoid damage, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage.
Mobile Home – Additional Installation Requirements
The installation of this cooktop must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the
Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part
280). When such standard is not applicable, use the Standard for Manufactured
Home Installations, ANSI A225.1/NFPA 501A or local codes. In Canada, the
installation of this range must conform with the current standards
CAN/CSA-Z240.1, latest edition, or with local codes.
Cabinet Dimensions
IMPORTANT: If installing a range hood or microwave hood combination above
the cooktop, follow the range hood or microwave hood combination installation
instructions for dimensional clearances above the cooktop surface.
- A. 30″ (76.2 cm) on 30″ models; 36″ (91.4 cm) on 36″ models
- B. Combustible area above countertop (shown by dashed box above)
- C. 30″ (76.2 cm) minimum clearance between top of the cooktop platform and bottom of the uncovered wood or metal cabinet (24″ [61 cm] minimum clearance if the bottom of wood or metal cabinet is covered by not less than 1/4″ [6.4 mm] flame retardant billboard covered with not less than No. 28 MSG sheet steel, 0.015″ [0.04 mm] stainless steel, or 0.024″ [0.06 mm] aluminium or 0.020″ [0.05 mm] copper)
- D. 13″ (33 cm) recommended upper cabinet depth
- E. 21⁄8″ (5.4 cm)
- F. 19″ (48.3 cm)
- G. 18″ (45.7 cm) minimum clearance from upper cabinet to countertop within minimum horizontal clearances to cooktop
- H. Grounded outlet: locate within 24″ (61 cm) of right rear corner of cutout
- I. 29″ (73.7 cm) on 30″ models; 351⁄4″ (89.5 cm) on 36″ models
- J. 83⁄8″ (21.3 cm) minimum distance to nearest left and right side combustible surface
- K. 27⁄8″ (7.3 cm) minimum distance to rear combustible surface
- L. Gas line opening – wall: anywhere 5″ (12.7 cm) below underside of countertop. Cabinet floor: anywhere within 6″ (15.2 cm) of rear wall is recommended
- M. 24″ (61 cm) minimum countertop depth is required
NOTE: After making the countertop cutout, some installations may require notching down the base cabinet side walls to clear the cooktop base. To avoid this modification, use a base cabinet with sidewalls wider than the cutout. If cabinet has a drawer, a 4″ (10.2 cm) depth clearance from the countertop to the top of the drawer (or other obstruction) in base cabinet is required. The drawer depth may need to be shortened to avoid interfering with the regulator.
Electrical Requirements
WARNING – Electrical Shock Hazard
- Plug into a grounded 3 prong outlet.
- Do not remove ground prong.
- Do not use an adapter.
- Do not use an extension cord.
- Failure to follow these instructions can result in death, fire, or electrical shock.
IMPORTANT: The cooktop must be electrically grounded in accordance with
local codes and ordinances, or in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
This cooktop is equipped with an electronic ignition system that will not
operate if plugged into an outlet that is not properly polarized. If codes
permit and a separate ground wire is used, it is recommended that a qualified
electrical installer determine that the ground path is adequate. A copy of the
above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
- A 120 V, 60 Hz AC only, 15 A, fused electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this cooktop be provided.
- Electronic ignition systems operate within wide voltage limits, but proper grounding and polarity are necessary. Check that the outlet provides 120 V power and is correctly grounded.
- The wiring diagrams are provided with this cooktop. See the “Wiring Diagrams”.
Gas Supply Requirements
WARNING- Explosion Hazard
- Use a new CSA International approved gas supply line. Install a shut-off valve.
- Securely tighten all gas connections.
- If connected to propane, have a qualified person make sure gas pressure does not exceed 14ʺ (36 cm) water column.
- Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel.
- Failure to do so can result in death, explosion, or fire.
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes and
ordinances. In the absence of local codes, installation must conform with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54 or, in Canada, the Natural Gas and
Propane Installation Code, CSA B149.1 – latest edition.
IMPORTANT: Leak testing of the cooktop must be conducted according to the
manufacturer’s instructions.
Type of Gas
-
Natural Gas:
This cooktop is factory set for use with Natural gas. If converting to Propane gas, see the following “Propane Gas Conversion” section. The model/serial/rating plate located on the underside of the cooktop base has information on the types of gas that can be used. If the types of gas listed do not include the type of gas available, check with the local gas supplier. -
Propane Gas Conversion:
Conversion must be done by a qualified service technician. No attempt shall be made to convert the cooktop from the gas specified on the model/serial/rating plate for use with a different gas without consulting the serving gas supplier. See the Gas Conversion instructions provided in the package containing literature.
®/™ ©2023 KitchenAid. All rights reserved. Used under license in Canada. Tous droits réservés. Utilisé sous licence au Canada.