Daintree WOS3 Wireless Battery-Powered Ceiling Mounted Occupancy Sensor Installation Guide

June 4, 2024
Daintree

DAINTREE LOGO

Daintree WOS3 Wireless Battery-Powered Ceiling Mounted Occupancy Sensor

Product Overview

The Daintree® Wireless Battery-Powered Ceiling Mounted Occupancy and Daylight Sensor may be deployed in a Daintree EZ Connect or Daintree Networked application. The WOS3-PC device is designed for ceiling installation on suspended ceiling tiles, or to drywall. This device is designed for energy savings based on space occupancy status and ambient light level. The communication with the Daintree system utilizes a secure and reliable wireless connection which helps minimize installation costs and complexity

BEFORE YOU BEGIN
Read these instructions completely and carefully. Save these instructions for future use.

IMPORTANT

To ensure the product warranty is valid, please ensure all installation instructions and environmental conditions for storage and operation are complied with. Installation to be performed by factory trained or qualified personnel.

Save These Instructions
Use only in the manner intneded by the manufacturer. If you have any questions, contact the manufacturer.

Installation

Installation of Back Plate onto Wall

  • Counterclockwise rotation to separate the back plate from the device.
  • Remove the insulation sheet.
  • (This step is for installing on wood or cement, if installing on drywall, jump this step.)
  • Drill a hole vertically on the wall. The hole diameter equal to the size of the expansion bolt. (This step is for installing on wood or cement, if installing on drywall, jump this step.) Insert the expansion bolt into the hole.
  • For installing on drywall, pass the screws through the installingholes on the back plate.
  • For installing on wood or cement, screw should pass the screws and align with the hole drilled in step3.
  • For installing on drywall, lock the screw vertically on the wall.
  • For installing on wood or cement, lock the screw into expansion bolts.

Installation of Device onto Back Plate

  • Align the device with back plate by positioning hole.
  • Clockwise rotation to install the device onto back plate.

Battery Replacement

  • Unscrew the screw
  • Remove the cover of battery
  • Remove the elder battery

Install new battery. then reverse previous steps to finish the battery replacement. (Only use CR14505 for WOS3-PC)

Mask Replacement

  • Put the ring into track, the Lock icon should be 10 degree to the triangle. Then clockwise rotate the ring.
  • When triangle is pointed to the lock icon on the ring
  • Put the mask into track, the triangle icon on mask is pointed to the triangle icon on body. Then clockwise or counter-clockwise rotate the ring.
  • When the triangle icon on mask is 90 degree to the triangle icon on body, mask is locked.

Product Dimensions

Daintree WOS3 Wireless Battery-Powered Ceiling
Mounted Occupancy Sensor. 17

Product Operation

Button FunctionalityDaintree WOS3 Wireless Battery-Powered Ceiling
Mounted Occupancy Sensor. 18

LED Indicator in Red

Daintree WOS3 Wireless Battery-Powered Ceiling Mounted Occupancy Sensor.
19

LED Indicator in GreenDaintree WOS3 Wireless Battery-Powered Ceiling
Mounted Occupancy Sensor. 20

Technical Data

Product SpecificationsDaintree WOS3 Wireless Battery-Powered Ceiling
Mounted Occupancy Sensor. 21

Product Availablity

Daintree WOS3 Wireless Battery-Powered Ceiling Mounted Occupancy Sensor.
22

Product Certifications

The alkaline batteries supplied with your wireless switch are prone to leak over their lifetime, particularly when the battery is mostly depleted. In the event that your battery leaks alkaline into the battery compartment, the chemicals can damage the metal terminals. The chances of this happening can be reduced by changing the batteries in the switch promptly when the batteries are nearing their end of their useful life. If a battery leak should occur, however, it should be cleaned up to prevent damage to the wireless switch.

WARNING: THE CHEMICALS LEAKED FROM ALKALINE BATTERIES ARE CORROSIVE. WHEN HANDLING LEAKING BATTERIES, PROPER PERSONAL SAFETY EQUIPMENT SHOULD BE USED, INCLUDING RUBBER GLOVES AND EYE PROTECTION.

If it is discovered that the batteries have leaked, wearing rubber gloves and using eye protection, remove all of the batteries from the battery compartment and seal them in a plastic bag. The bag should be discarded in a manner in accordance with local laws and regulations. Then, using a small cloth lightly moistened with vinegar or other mild acid, carefully wipe all of the leaked battery chemicals from inside the battery compartment and allow it to dry. Once dry, the batteries may be replaced and the switch may be reinstalled.

Supplier’s Declaration of Conformity 47 CFR § 2.1077 Compliance Information

  • Product Name: Wireless Battery-Powered Ceiling Mounted Occupancy and Daylight Sensor
  • Model No: WOS3-PC
  • Supplier’s Name: Current Lighting Solutions, LLC
  • Supplier’s Website: www.gecurrent.com
  • Supplier’s Address (USA): Cleveland, Ohio
  • Supplier’s Phone: 1-866-855-8629

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  • This device may not cause harmful interference, and
  • this device must accept any interference received, including interference that may cause undesired operation.

This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic

Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions:

  • This device may not cause interference.
  • This device must accept any interference including interference that may cause undesired operation of the device.

FCC RF Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body.

ISED RF Radiation Exposure Statement:
This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body.

Caution : The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

FCC

Note : This equipment has been tested and found to comply with the limits for a Clas B digital device, pursuant to part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interterence by one or more of the following measures

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/ TV technician for help

NEED HELP

2021 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the General Electric Company and are used under license. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. DT041 -Daintree-WWD2-2IW-Wall-Dimmer-Installation-Guide www.gecurrent.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals