TECHNICAL PARAMETERS
Voltage: AC110 ~ 240V, 50 / 60HZ
Sources: Bulbs
Dimming: 0-100% linear dimming
Strobe: Single chip strobe, electronic focusing
Color: 1 fixed color plate, 13 colors + white light, half step color
effect
Fixed image: 1 fixed pattern disk, 15 patterns + white light
Channel mode: 16 / 20 international standard DMX512 channels, master-
slave mode
LED DISPLAY
- Display
- Menu
- Down
- Enter
- Up
- Dmx in
- Dmx Out
- Power In
- Power Out
- Power switch
UNPACKING INSTRUCTIONS
When you receive the device, unpack it, check that the contents are complete and intact, notify the carrier immediately if it shows damage, and keep all packing materials for safe transportation of the device.
- 1 pcs moving head
- 1 manual
- 1 power cord
- 1 bracket
- 1 Screws (installed on the machine)
SAFETY INSTRUCTIONS AND OPERATING INSTRUCTIONS
After the power is plugged in and the switch is turned on, “rSt” is displayed. The moving headlights are being reset, please do not operate.
- Plugged into a grounded power outlet for indoor use only.
- Don’t expose the device to rain or moisture, avoid the risk of fire or electric shock. Make sure that no flammable objects near the device.
- Install the equipment in a well-ventilated place at least 50cm from any surface, and ensure that the ventilation slots are not blocked.
- Disconnect the equipment from the power supply before any operation.
- The ambient temperature should not exceed 40°C, and the maximum ambient temperature is 45°C. Don’t operate the device at higher temperatures.
- The equipment should be stopped immediately, if a fault occurs, and do not repair the equipment by yourself. Improper maintenance can result in damage and malfunction. Contact technical support for repair approval. Only the same accessories can be used with the original parts, and make sure the power cord is not blocked or damaged.
- Do not expose your eyes to light sources, which can be a sign of a seizure in sensitive people.
- The lamps are only used for decoration and not suitable for ordinary household lighting.
- Replacing the fuse: Unplug the device from the power supply, remove the fuse holder from its original position with a screwdriver, take out the burnt fuse, replace the fuse with the same characteristics, then re-rotate the screw, and connect the device to the power supply superior.
- WARNING: Stop using it if the fuse is still blowing after being replaced. Please contact customer support for further instructions, continued use may cause serious damage.
Please read this manual carefully before operating this product.
-
Fix the equipment with the screw holes on the bracket to ensure that the equipment is firmly fixed to prevent vibration and movement during operation, and always check whether the structure of the equipment is strong enough to withstand equipment that is at least ten times.
-
The equipment must be fixed by professionals in places that elders and children cannot reach, and no one can pass under or over the pedestrian crossing.
-
End-of-life of the product: This sign indicates that this product should not be thrown into household waste in European Community countries and that waste should be recycled to support the sustainable recycling of resources in order to protect the environment and human health Utilize. If you need to recycle used electrical appliances, please go to an electrical appliance collection center or contact the dealer where you purchased the product to ensure the ecological recycling of the product.
Remote Control: If you want to control the light by remote, please unplug the DMX cable and set Remote Control to ON. If you want to control the device via the menu, set the remote to off. -
Install the bow bracket with the bow bracket
-
Confirm that the bracket position is installed correct!
-
Position is installed successfully Confirm whether the bracket.
-
Install the bow bracket and fix it with screws.
Hook brackets are not included in the package
STARTUP STEPS FOR VARIOUS MODES
-
Automatic mode:
Press “up” or “down” to select “(setup) to enter the secondary menu, select” enter “in” run mode “, press ” up “or” down “to select” auto “for confirmation. -
Automatic mode selection:
Press “up” or “down” to select “(setup) to enter the secondary menu, select” enter “in” run mode “, press ” up “or” down “to select” auto “for confirmation.
CONSOLE MODE AND MASTERSLAVE MODE
Dmx out to No. 1 fixture dmx in; No. 1 fixture dmx out to No. 2 fixture dmx in; Press “menu” to find “addr”, press “enter”, display “a00l” Press “Up” or “Down” to select the console the value of.
Master-slave setting: No. I lamp is set to self-propelled or voice-activated function according to the startup mode; 2, 3, 4**** are set to DMX512 mode: OMX address code is 001;
16/20 CHANNEL
Channel1 | Channel2 | Name | Numerical value | Describe |
---|---|---|---|---|
CH 1 | CH 1 | Color | 0-4 | Whit light |
5-9 | Whit light + color 1 | |||
10-14 | Color1 | |||
15-19 | Color1 + color2 | |||
20-24 | Color2 | |||
25-29 | Color2 + color3 | |||
30-34 | Color3 | |||
35-39 | Color3 + Color4 | |||
40-44 | Color4 | |||
45-49 | Color4 + color5 | |||
50-54 | Color5 | |||
55-59 | Color5 + Color6 | |||
60-64 | Color6 | |||
65-69 | Color6 + color7 | |||
70-74 | Color7 | |||
75-79 | Color7 + color8 | |||
80-84 | Color8 | |||
85-89 | Color8 + color9 | |||
90-94 | Color9 | |||
95-99 | Color9 + color10 | |||
100-104 | Color10 | |||
105-109 | Color10 + color 11 | |||
110-114 | Color11 | |||
115-119 | Color11 + color12 | |||
120-124 | Color12 | |||
125-129 | Color12 + color 13 | |||
130-134 | Color13 | |||
135-139 | Color13 + white light | |||
140-200 | From fast to slow, forward flow | |||
201-255 | From slow to fast, flowing water | |||
CH 2 | CH 2 | Stroboscopic | 0-3 | Turn off |
--- | --- | --- | --- | --- |
4-103 | From slow to fast pulse strobe | |||
104-107 | Open | |||
108-207 | Gradually variable frequency flashing from slow to fast | |||
208-212 | Open | |||
213-251 | Random strobe from slow to fast | |||
252-255 | Open | |||
CH 3 | CH 3 | Dimming | 0-255 | 0-100% dimming |
CH 4 | CH 4 | pattern | 0-4 | White light |
5-9 | Pattern1 | |||
10-14 | Pattern2 | |||
15-19 | Pattern3 | |||
20-24 | Pattern4 | |||
25-29 | Pattern5 | |||
30-34 | Pattern6 | |||
35-39 | Pattern7 | |||
40-44 | Pattern8 | |||
45-49 | Pattern9 | |||
50-54 | Pattern10 | |||
55-59 | Pattern11 | |||
60-64 | Pattern12 | |||
65-69 | Pattern13 | |||
70-74 | Pattern14 | |||
75-113 | From fast to slow, forward flow | |||
114-117 | Stop(no pattern) | |||
118-159 | Reverse flow from slow to fast | |||
160-190 | Shake pattern 1 from slow to fast | |||
191-195 | Shake pattern 2 from slow to fast | |||
196-200 | Shake pattern 3 from slow to fast | |||
201-205 | Shake pattern 4 from slow to fast | |||
206-210 | Shake pattern 5 from slow to fast | |||
211-215 | Shake pattern 6 from slow to fast | |||
--- | --- | --- | --- | --- |
216-220 | Shake pattern 7 from slow to fast | |||
221-225 | Shake pattern 8 from slow to fast | |||
226-230 | Shake pattern 9 from slow to fast | |||
231-235 | Shake pattern 10 from slow to fast | |||
236-240 | Shake pattern 11 from slow to fast | |||
241-245 | Shake pattern 12 from slow to fast | |||
246-250 | Shake pattern 13 from slow to fast | |||
251-255 | Shake pattern 14 from slow to fast | |||
CH5 | CH5 | Prism | 0-127 | Remove the prism |
128-255 | Insert prism | |||
CH6 | CH6 | Prism Rotation | 0-127 | 0-400 degrees |
128-190 | From fast to slow, forward flow | |||
191-192 | Stop it | |||
193-255 | Reverse flow from slow to fast | |||
CH7 | CH7 | Colorful | 0-127 | nothing |
128-255 | Colorful | |||
CH8 | CH8 | atomization | 0-127 | nothing |
128-255 | atomization | |||
CH9 | CH9 | focusing | 0-255 | From far to near |
CH10 | CH10 | X axis | 0-255 | 0-540 ° |
CH11 | CH11 | X-axisfine adjustment | 0-255 | |
CH12 | CH12 | Y axis | 0-255 | 0-270° |
CH13 | CH13 | Y-axisfine adjustment | 0-255 | |
CH14 | CH14 | XY speed | 0-255 | From fast to slow |
CH15 | CH15 | reset | 128-255 | Reset the whole machine for more than 6 seconds |
CH16 | CH16 | Lightbulb | 26-100 | Turn off the light gun for more than 6 seconds |
101-255 | Turn on the light cannon for more than 6 seconds | |||
CH17 | retain |
CH18
| Color wheel speed|
0-255
|
From fast to slow
CH19| Focusing speed| 0-255| From fast to slow
CH20
| Chart disk speed| 0-255| From fast to slow
Read User Manual Online (PDF format)