Sunco 2×2 LED Flat Panel Light Installation Guide

June 15, 2024
SUNCO

Sunco 2×2 LED Flat Panel Light

Sunco-2x2-LED-Flat-Panel-Light-PRODUCT

Specifications

  • Voltage: 110-277 VAC
  • Wattage: 40W
  • Moisture Rating: Damp Rated
  • Housing Material: SPCC+PC Lens
  • Weight: 4lbs
  • Warranty: 7 Years

Product Usage Instructions

Installation

  1. Turn off the switch and circuit breaker before installing the LED light fixture.
  2. Turn the ceiling panel face down on a flat surface.
    • Unscrew the (2) driver covers and set aside screws.
  3. Pop-out (2) knockouts of your choice from the available 6.
  4. Connect the supply wires to the ceiling panel wires using the included wire nuts:
    • Black to Black (live)
    • White to White (neutral)
    • Green to Green (ground)
  5. If using a dimmer (not included), connect the DIM+ and DIM wiring of the ceiling panel to your dimmer using the included wire nuts (optional).
  6. Replace the driver covers and tighten the screws firmly.
  7. Connect the conduit to each knockout and pass wires through.
  8. Locate (2) protective brackets on the back of the panel and bend them up 90 degrees.

Installation Tools

  • Drill
  • Ladder
  • Hammer
  • Pliers
  • Tape Measure
  • Pencil
  • Phillips Screwdriver

Mounting

  1. Install the LED ceiling panel light in the ceiling using the protective brackets.
  2. Turn on the circuit breaker and test the light.

FAQ

Q: Can I use this LED ceiling panel in a damp environment?

  • A: Yes, this LED ceiling panel is damp-rated and can be used in environments with moisture.

Q: What is the warranty for the 2X2 LED ceiling panel?

  • A: The warranty for the 2X2 LED ceiling panel is 7 years.

Q: Is the dimmer included with the ceiling panel?

  • A: No, the dimmer is not included with the ceiling panel. It needs to be purchased separately.

Q: What are the required tools for installation?

  • A: The required tools for installation are a drill, ladder, hammer, pliers, tape measure, pencil, and Phillips screwdriver.

INCLUDED HARDWARE

EASY INSTALLATION

RECESSED

  1. Turn off the switch and circuit breaker before installing this LED light fixture.
  2. Turn the ceiling panel face down on a flat surface.
    • Uns crew the (2) driver covers and set aside screws.
  3. Pop-out (2) knockouts (choice of 6).
  4. Connect supply wires to ceiling panel wires with included wire nuts.
    • Black to Black (live):
    • White to White (neutral);
    • reen to Green (ground).
  5. Replace driver covers.
    • Tighten screws firmly.
  6. Twist brackets 90° so hooks face the outside edge of the ceiling panel
  7. Connect the conduit to each knockout.
    • Pass wires through.
  8. (Optional) If using a dimmer (not included) connect DIM+ and DIM- wiring of the ceiling panel to your dimmer with included wire nuts.
  9. Locate (2) protective brackets on the back of the panel. Bend up 900.
  10. Install LED ceiling panel light in the ceiling, using protective brackets.
  11. Turn on the circuit breaker and test the light.

SPECIFICATIONS

  • Voltage: 110-277 VAC
  • Wattage:  40W
  • Moisture Rating: Damp Rated
  • Housing Material: SPCC+PC Lens
  • Weight: 4lbs
  • Warranty: 7 Years

WARNING

To reduce the risk of fire, electric shock, or physical injury:

  • This product should be installed by a qualified electrician familiar with the construction and operation of the product and the hazards involved.
  • Check for shipping damage before installing. If the product is damaged, do not use it.
  • Always turn off the switch and circuit breaker before installing. Proper grounding is required to ensure safety.
  • This fixture is not suitable for wet environments. LED must be installed in an appropriate environment to work. Harsh environments may shorten the life or damage the light.
  • Clean the fixture regularly to ensure proper operation and efficient lighting. Do not clean with harsh solvents.
  • Use safety precautions and abide by regional and local laws or regulations.
  • Safety eyeglasses and gloves are recommended.

FCC NOTES

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1.  This device may not cause harmful interference,
  2. this device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, according to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used under the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.