adiding 200W LED High Bay Light Instruction Manual
- June 15, 2024
- Adiding
Table of Contents
200W LED High Bay Light
LED HIGH BAY
LIGHTING
Instruction Manual
Thanks for your purchase
LED HIGH BAY LIGHT
Shark series
FEATURES
-
Intended use
The Adiding led high bay light is the affordable led solution for users who prefer a luminaire with the look and feel of a round form factor, gymnasiums, warehouses, packaging facilities and other industrial applications. All benefit from Adiding’s highly efficient design that saves up to 67% over traditional sources. -
Construction
Adiding features an aluminum heat sink to maximize heat dissipation, and extend the life of the luminaire by maximizing contact with the LEDS. Plastic optical enclosure (IP65 rated) protects the LEDs from dust and other air contaminants. -
Electrical
Standard 100-227V AC surge protection, tested in accordance with IEEE/ANSI standards. Input voltages include 100-277, without the use of a step-down transformer. Lumen maintenance at 50,000 hours 1(0)-10v dimming is standard for a dimming range from 10%(0%) to 100%. -
Ingtallation
Mounting options include steel hook & cord or options listings.
Working temperatures from -22 °F up to 122°F.
Parking Lot nght
- MaximLm power up to 300w,up to 39000 lumens
- Optimized mount kit allows single person installation
- Demountable design,easy for maintenance
- Up-to-date design. With verical lens and gather 4 LED in one bulb
- 5 years warranty
Stadium Light
- Unique “SSD” design, simple, and advanced. Ensures durability of the LED chip. All parts are individual, rugged and strong.
- Advanced, free-form, optics designed with unique-multi-scales lenses” to create uniform light distribution and glare-reduction. Advanced materials maximize light output.
- State-of-the art circuit system which works perfectly with other systems. Ultra-low EMI noise generation eliminates electrical interference.
- Seamless link between aerometal materials and numerous heat sink vents to improve heat management and ensure stability of lighting system.
- 5 years warranty
High Bay nght Wlth MOtlon Sensor
- 100-277V voltage compatible, 150Lm/W high LED light efficacy.
- Unique carabiner hook design for convenient installaion and uninstalied:
- Optional mation sensor and remote controller to select different modes
- IPB5 grads waterproof, sultable for indoor or outdoor, wet location, etc:
- 5 years warrenty
Dimmer without load
The light power supply is not powered by dimmer. This kind of connection mode is dimmer without load, which don’t need to consider load power and load current,only need to consider less than effective optical current 200mA. According to each 0/1-10v adjustable light power signal current of 10mA conservative estimates there are up to 2- dimming power sources can be connected in parallel.
Dimmer with load
-
The light power supply is powered by the dimmer. The light is the load of the dimmer power supply.
it is necessary to consider the load power and load current. The maximum eective load of the dimmer is 800watt and the current is 10A. -
When AC 120-277 input effective power is 800watt.current is 10A; When AC100-277V input effective power is 400watt, current is 10A.
-
The following is the number of dimmable power supply in parallel of two input voltages.
– When AC120-277V input:800W/100W=8pcs , 10A/2A=5pcs,take the minimum value, so it can parallel 5 dimming power supply.
– When AC120-277V input:400W/100W=4pcs,10A/2A=5pcs take the minimum value, so it can parallel 4 dimming power supply
Divension
Power| Lumens| Luminaire Efficacy| Diameter(inch)|
Height(inch)| Package Size(inch)
---|---|---|---|---|---
100W| 17000LM| 170Im/w| 1024| 4.9| 12.2412.246.9
150W| 25500LM| 4.9| 12.2412.26.9
200W| 34000LM| 5.7| 12.212.217.7
250W| 42500LM| 6.6| 12.2112.27.7
120° DISTRIBUTION
OTHER SPECIFICATION
Product/Parameter | 100W | I 150W I | 200W | 250W |
---|---|---|---|---|
Input Voltage | AC100-277V | |||
Power Frequency | 50/60hZ | |||
Power Efficiency | >93% | |||
Beam Angle | 120° | |||
LED Efficiency | 170LMNV | |||
CCT | 5000K | |||
C RI | >70Ra |
ATTENTION
Before you install
Please read these instructions completely and carefully
Warning/Avertissement
Risk of electric shock .
- Turn power off before inspectioninstallation or removal
- Property ground electrical enclosure
- Follow all NEC and local codes
- Use only OLC or IEC approved wire for input/output connections
Prepare Electrical wiring
Electrical Requirements
The led driver must be supplied with 100-277VAC, 50/60Hz per product grounded
branch circuit, protected by a 15 or 20 ampere circuit breaker.
Grounding Instructions
The grounding and bonding of the overall system shall be done in accordance
with national electric code (NEC) Article 600 and local codes.
Announcements
- This equipment is only for professional installation. Non-professional personnel shall not remove or install the equipment.
- Please read the instruction manual before installation and keep it for future reference.
- To avoid damage. falling, electric shock or fire, please do not modify the lamp or replace accessories without confirming with the supplier.
- Maintenance/installation and replacement of the lamps, please confirm to cut off the power supply, and the lamps have set up a cooling. Please make sure the lamps and has been properly installed before processing power.
- Ensure the accurate and reliable connection.
- Ensure that the product around the vent, the lamp cannot violate any fire prevention regulations when using.
INSTALLATION
-
Please check that the plug is in good condition.
Install the lamp and plug it into the socket.
Then you can test the light fixture: -
Please connect the input wire in correct way, black wire is L, white ire is N, green wire is ground connection Please also make sure the wire connection is fixed perfectly before using.
| | |
---|---|---|---
Drilling holes in the celing, and installthe expansion screws and hook.|
Hanging the fiture.| the dinmig cabie( need).
Plug the power cable and connect| ol the safety rope and tighten .