InfiRay G600 Uncooled Handheld Thermal Camera User Manual
- June 15, 2024
- InfiRay
Table of Contents
- InfiRay G600 Uncooled Handheld Thermal Camera
- Uncooled Handheld Thermal Camera for Gas Leak Detection
- Safety Information
- Notice to user
- Product Introduction
- Product Specifications
- Quick Start Guide
- User Interface
- Operation Instruction
- Screen Brightness
- Formatting the SD Card
- USB Mode
- Structural Drawings
- Cleaning Thermal Camera
- Worth comes from Service
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
InfiRay G600 Uncooled Handheld Thermal Camera
Specifications
- Product Name : Uncooled Handheld Thermal Camera for Gas Leak Detection
- Manufacturer: IRay Technology Co., Ltd.
- Website: www.infiray.com
- Main Products: IRFPA detectors, thermal imaging modules, and terminal thermal cameras and imagers
- Applications: Industrial thermography, outdoor night vision observation, AI, machine vision, automatic driving, security and fire control, Internet of Things, and epidemic prevention and control
Uncooled Handheld Thermal Camera for Gas Leak Detection
User Manual V1.0.3
Introduction to IRay Technology
- IRay Technology concentrates on developing infrared thermal imaging technologies and manufacturing relevant products, with completely independent intellectual property rights. IRay is committed to providing global customers with professional and competitive infrared thermal imaging products and solutions. The main products include IRFPA detectors, thermal imaging modules, and terminal thermal cameras and imagers.
- With R&D personnel accounts for 48% of all employees, 1760 intellectual property projects in terms of IRay have been authorized and accepted: 1099 patented technologies authorized and accepted in China (including those for integrated circuit chips, MEMS sensors design and manufacture, Matrix IV image algorithms and intelligent precise temperature measurement algorithms, etc.); 277 trade mark applications in China; 35 patents and patent applications overseas; 107 trade mark applications overseas; 191 software copyrights; and 51 integrated circuit layout designs.(The statistic data is up to August, 2022)
IRay products have been applied in various fields, including industrial thermography, outdoor night vision observation, AI, machine vision, automatic driving, security and fire control, Internet of Things, and epidemic prevention and control.
Legal Disclaimer
-
The thermal cameras manufactured by IRAY TECHNOLOGY CO., LTD. (Hereinafter referred to as “THE COMPANY” or “IRAY TECHNOLOGY”) are warranted for a period of two-year and the accessories are warranted for a period of three-month form the delivery date of the original purchase, provided such products have been under normal storage, use and maintenance.
-
This warranty extends only to the original purchaser and is not transferable. It is not applicable to any product which has be subjected to misuse, neglect, accident or abnormal conditions of operation.
In the case of a defect in a product covered by this warranty the product must not be further used or maintained in order to prevent additional damage. The purchaser shall promptly report any defect to IRAY -
TECHNOLOGY or this warranty will not apply.
-
IRAY TECHNOLOGY will, at its option, repair or replace any such defective product free of charge if, upon inspection, the product or accessories prove to be defective, the user can contact with after-sales service department of IRAY TECHNOLOGY within the said warranty period.
Copyright
- ©IRay Technology Co., Ltd. 2023. All rights reserved worldwide. All contents in this manual, including words, pictures, images, etc., belong to IRAY TECHNOLOGY. No part of the manual, in whole or part, may be copied, photocopied, translated, or transmitted without the prior written permission of IRAY TECHNOLOGY.
- This manual is used as a guide. The photos, graphics, diagrams and illustrations provided in the manual are only used to explain, which may be different from the specific product. The real product shall prevail. We try our best to make sure the contents in this manual are accurate. We do not provide any representations or warranties in this manual.
- IRAY TECHNOLOGY reserve the right to update the manual. If you need the latest version of this manual, please contact us. It is recommended that you use this manual with the guidance of professionals.
Quality Assurance
- The Quality Management System under which these products are developed and manufactured has been certified in accordance with the ISO9001 standard.
- We reserve the right to make changes and improvements on any of the products without prior notice.
Safety Information
WARNING
-
Make sure you read all applicable Material Safety Data Sheets (SDS) and warning labels on containers before you use a liquid. The liquids can be dangerous. Injury to persons can occur.
-
It is prohibited to use the product in a high temperature above 85 °C or in a low temperature below-45 °C.
-
It is forbidden to disassemble or refit the thermal camera at will.
-
Do not use too long screws when installing the front/rear mounting bracket, which may damage the thermal camera.
CAUTION
- No matter there is a lens cover or not, do not point the infrared thermal camera towards strong light or equipment with laser radiation. This will affect the accuracy of the thermal camera and even damage the detector in the thermal camera.
- Do not use the product under conditions that doesn’t match the environmental requirements. For specific use environment requirements, see the product parameter table.
- Do not apply solvents or equivalent liquids to the camera, the cables, or other items.
- Be careful when you clean the infrared lenses. The lens has an anti-reflective coating which is easily damaged. Damage to the infrared lens can occur with too much force or cleaning with rough objects such as tissues.
Notice to user
Calibration
IRAY TECHNOLOGY recommends that you verify your calibration yearly in order to
ensure accuracy. You can verify the calibration through IRAY TECHNOLOGY or
third-party organizations.
Accuracy
- The G Series handheld thermal cameras have temperature measurement function, for very accurate temperature measurement results, we recommended that you wait 5 minutes after you have started the camera
- before measuring a temperature.
Video Teaching
- You can search for mount and use videos from our website.
Documentation Updates
- Our manuals are updated several times per year, and we also issue product-critical notifications of changes on a regular basis. Please visit our website to access the latest manuals and notifications.
Scope of Application
- This manual is applicable for all products in a range, which means that parts of the manual may not apply to a particular model.
- 4.Customer Help
FAQ
- You can find answers to FAQ about this model on the service support page of our official website.
Download
- You can download the following contents from our website: www.infiray.com
- Product Documentation
- Client Software
- Video Teaching Courses
Product Introduction
Camera View from the front)
Figure5.1 Introduction to Camera Components
No.|
Components
---|---
1| Infrared Lens
2| Digital Camera
3| Laser Pointer
4| Trigger
Note : the laser warning label is stuck on the lens cap.
Buttons View from the rear)
Figure5.2 Introduction to Buttons
No. | Components | Function Description |
---|---|---|
1 | Display screen | |
2 | Gallery button | Press to open the gallery. Long press to perform image |
uniformity correction.
3| Navigation button| Make selections for the menu, settings, gallery by
clicking up/down/left/right.
4| Power/Laser button| Click to turn on/ Long press to turn off. When it is
on, click to turn on/off the laser pointer.
5| Back button| Click to cancel the operation or return to the previous one.
Long press to perform image uniformity correction.
6| Enter button| Click OK to confirm the operation.
Table 5.2 Component Introduction (View from the Rear)
Connector and Memory Card
Figure5.3 Illustration of Connector and Memory Card
No. | Name | Description |
---|---|---|
1 | USB Interface |
- Connect a USB cable with the power adapter for charging.
- Connect a USB cable to a computer to charge or transfer data.
2| SD Card|
- Standard MicroSD card, standard 32GB, Max 512GB
- The SD card can be taken out and transfer data to PC or other devices with a card reader.
Table 5.3 Connector and Memory Card
Product Specifications
Technical Specifications | G600C | G600F |
---|---|---|
Thermal | Detector Type | Uncooled VOx infrared detector |
VOx infrared detector
Detector Resolution| 640×512| 640×512
Spectral Range| 7.0-8.5μm| Central wavelength 10.55μm
| Gases Detectable|
- Methane Nitrous oxide Sulfur dioxide Phenol
- Ethyl acrylate
- 2-Ethylhexyl acrylate R13
- R13B1 R123 R125 R134A R417A R422A R508A
| Sulfur hexafluoride Ammonia Ethylene
- Ethylene ether Vinyl chloride Trichloroethylene Methyl vinyl ketone Propylene
- Acrolein Acrylonitrile
- Ethyl cyanoacrylate Allyl fluoride
- Allyl chloride
- Allyl bromide Furan
---|---|---|---
Pixel Pitch| 12μm| 12μm
Thermal
Sensitivity
| 23mk@7-14um| 23mk@7-14um
IFOV ( spatial resolution )| 0.63mrad|
0.63mrad
Frame Rate| 25Hz| 25Hz
Focal Length| 19mm| 19mm
FoV| 23°x18°| 23°x18°
Focus Mode| Manual focus| Manual focus
Temperature Measurement Range| 20 ℃- 120 ℃| 20 ℃- 120 ℃
Temperature Measurement Accuracy| 2% or ±2℃| ±2% or ±2℃
The Temperature Increment| 0.1°C| 0.1°C
Camera Function| Temperature
Measurement Mode
| Center spot/hot and cold spot tracing and temperature display| Center
spot/hot and cold spot tracing and temperature display
---|---|---|---
Self-defined Spots, Lines and Areas Measurement| Movable
spot/line/area temperature measurement; Support 10 spots, 10 lines and 10
areas at most| Movable spot/line/area temperature measurement; Support 10
spots, 10 lines and 10 areas at most
Temperature Measurement Unit| Celsius, Fahrenheit, Kelvin|
Celsius, Fahrenheit, Kelvin
Emissivity Setting| 01-1.00, in 0.01 increment| 0.01-1.00, in 0.01
increment
Environmental l Temperature Setting| -10~50℃, in 1℃ increment|
-10~50℃, in 1℃ increment
Distance Setting| 1-20m, in 1m increment| 1-20m, in 1m increment
Image Mode| Infrared, visible, dual-spectrum fusion, PIP| Infrared,
visible,
dual-spectrum fusion, PIP
Color Palettes| 10 types| 10 types
Temperature Alarm| Yes| Yes
Alarm Type| Image Alarm| Image Alarm
Temperature Scale| Manual/Auto| Manual/Auto
Laser Pointer| Yes| Yes
Digital Camera| 5MP| 5MP
Video/Image Storage| XX-IR.jpg (infrared image with temperature
data) and XX-DC.jpg (visual image); Video without data| XX-IR.jpg (infrared
image with temperature data) and
XX-DC.jpg (visual image);
Video without data
Voice Annotation| Yes| Yes
| Language| Traditional Chinese, English, French, Spanish, Italian,
Brazilian Portuguese, German, Polish, Russian, Korean, Hungarian, Turkish,
Japanese.| Traditional Chinese, English, French, Spanish, Italian, Brazilian
Portuguese, German, Polish, Russian, Korean, Hungarian, Turkish, Japanese.
---|---|---|---
Display| 3.5-inch touch screen (480×640)| 3.5-inch touch screen
(480×640)
Image Naming| Automatic, manual, naming
by scanning QR code
| Automatic, manual, naming by
scanning QR code
Memory Card| Standard 32GB MicroSD card, support at most 512GB| Standard
32GB MicroSD card, support at most 512GB
Battery Type| Rechargeable and
removable Li-ion battery
| Rechargeable and removable
Li-ion battery
Power Interface| USB Type C| USB Type C
Connectivity Type| USB, SD card, Wi-Fi(AP
mode)
| USB, SD card, Wi-Fi(AP
mode)
Charging
Time
| About 3h| About 3h
Battery Life| About 3h| About 3h
Power Management| Automatic shutdown:5min,
10min, 20min or disabled
| Automatic shutdown:5min,
10min, 20min or disabled
Others| Analysis
Software
| PC&APP| PC&APP
Tripod
Support
| Yes| Yes
Operating Temperature
Range
| -10 to +50°C| -10 to +50°C
Storage
Temperature Range
| 20 to +60°C| -20 to +60°C
Relative Humidity| 10% ~ 95%,
non-condensing
| 10% ~ 95%,
non-condensing
| Drop| 2m| 2m
---|---|---|---
Encapsulatio
n Rating
| IP54(IEC 60529)| IP54(IEC 60529)
Shock & Vibration| Shock :25g(IEC
60068-2-27); Vibration: 2.5g(IEC60068-2-6)
| Shock :25g(IEC 60068-2-27);
Vibration: 2.5g(IEC60068-2-6)
Dimensions
( HxWxD )
| 256.4 x 105.1 x 105.3mm| 256.4 x 105.1 x 105.3mm
Weight| About 670g| About 670g
Certifications| CE/FCC/UKCA/ROHS/AT
EX
| CE/FCC/UKCA/ROHS/ATEX
**Accessories**| 5V 3A power adapter, USB cable, SD card, battery ×2,
QSG, calibration certificate, battery charger,
package list
| 5V 3A power adapter, USB cable, SD card, battery ×2, QSG, calibration certificate, battery charger, package list
Quick Start Guide
Please follow the procedures :
1.Charging
-
5V 3A power adapter and USB cable can be used to charge the device.
-
You can charge the device by connecting the USB cable in the accessory to the computer.
Note : This method of charging takes longer time than using the power adapter -
Charging base can also be used to charge the battery.
Power on
Click the power button to start the device.
Target Searchin
Point the thermal camera at the object of interest.
Image Capturing
Click the trigger button to capture the image, and record the video by long
pressing the trigger button.
User Interface
Figure 7.1 User Interface
No. | Name | Description |
---|---|---|
1 | Main Menu | Gas parameters, measurement parameters, measurement mode, image |
mode, color palettes and
other settings can be set.
2| Sub Menu| specific options can be set, such as a specific color
palette.
3| Temperature measurement spot| measurements of center spot, high/low temperature spot tracking, customize spot, customize line,
customize area measurement are available.
4| Center spot temperature| the temperature of the center spot is displayed.
5| Date and time| date and time are displayed.
6| Battery capacity| the remaining battery capacity is displayed.
7| Temperature range| the temperature range in the current screen can be
displayed.
Operation Instruction
Charging
Charge with a Power Adapter
- Plug the power adapter into the socket.
- Use a USB cable to connect the adapter and the camera to charge. Note:It takes about 3h to get the device fully charged.
Charge with a Computer
- Use a USB cable to connect the thermal camera to the computer to charge.
Note : when charging with a computer, the computer should be turned on, and the charging time is longer than using an adapter.
Charge with a Charging Base
- Connect the power adapter and the charging base with a USB cable, and plug the power adapter into the socket.
- Take out the battery and place it correctly in the charging base to charge.
Note : When the battery is not placed, the indicator of the charging base flashes; the indicator turns red when the battery is placed and charging; the indicator becomes green when the battery is fully charged.
Power On/Off
- Click the power button to start the device.
- Press the power button about 3 seconds to turn it off.
Focus Adjustment
- Make sure that the device is powered on, align the camera at the measured scene, rotate the focus ring beside the lens clockwise or counterclockwise, which can make the image clearer via focal length adjustment, see the following figure for the detailed adjustment method:
**Figure 8.1 Focus Adjustment Through Focus Ring**
Images/Videos Capture
- In the observation interface, adjust the focus ring till the image is clear. Short press the trigger button to take the photo. Long press the trigger button to start recording video, release the trigger button to continue recording, and long press the trigger button again to stop recording.
- Tap the save button on the touch screen or click the OK button or short press the trigger button to save the photos. Tap other buttons on the touch screen or use the navigation button + OK to scan the QR code to name the file, or cancel saving photos.
View Photos/Videos
The pictures you took are saved in the SD card, and you can follow the below
steps to view them at any time.
- Enter the photo gallery by clicking gallery button.
- Select the picture or video you want to view by pressing the navigation button or screen.
- Press OK or click the picture or video to view it in full screen. Select the delete option and then confirm to delete the current item. Select the rename option and confirm to rename the current item.
- When in the preview interface, click the multiple button in the upper right corner of the screen, then select the picture or video to be deleted, and delete the selected items by pressing the delete button.
- Return to observation interface by clicking the gallery button, back button or touch screen.
Set Gas Detection Mode
- On the observation interface, short press the OK button to show the main menu, and select the Gas Detection Mode option, press the OK button again to show the sub menu, select On or Off by navigating left or right, then click the OK button to configure the parameters, click the OK button again to enable the function.
- On the observation interface, click anywhere on the touch screen to show the main menu, click the Gas
- Detection Mode option, click On or Off, click the image area to enable the function.
Measurement Parameters
-
In the observation interface, press OK to enter the main menu, use the navigation button to select the
Parameter Setting , then press OK again to enter the secondary menu. Select different temperature measurement parameters by shifting left or right, and press the enter button to parameterize. After setting, press OK again to save your option. -
In the observation interface, click anywhere on the screen to enter the main menu. Click Parameter
-
Setting to set the parameter. After finishing the setting, click the screen area to take effect.
-
Emissivity : in order to obtain more accurate measurement results, you need to set the emissivity according to the target to be measured before each measurement, instead of using the default configuration. Emissivity refers to the ratio of the radiant ability of an object to the radiant ability of a blackbody at the same temperature, which is relative to the reflectivity of the object. The lower the emissivity, the higher the proportion of energy being reflected. The higher the emissivity, the lower the proportion of energy being reflected. For example, the emissivity of human skin is 0.98, and the emissivity of printed circuit boards is 0.91. For more information on emissivity, you can refer to the quick start guide in the package or inquire from other sources.
-
Ambient temperature : the reflection temperature of the object surface will affect the measurement result, especially when the object emissivity is low or the object temperature and the reflection temperature differ greatly, this effect will increase. So the result needs to be compensated to eliminate influences of the surface reflection temperature. However, it is usually difficult to determine the reflected temperature of an object. The ambient temperature can be used to replace the reflected temperature in actual measurement.
-
Distance : distances have effects on the measurement results. In order to get accurate measurement, distance information of the object is necessary for the thermal camera to compensate the result
Palettes
- In the observation interface, short press OK to enter the main menu, and select Palette Setting with the navigation button. Press OK again to enter the sub menu, select different palettes by shifting left and right on the navigation button, and then press the enter button to save your option.
- In the observation interface, click anywhere on the touch screen to enter the main menu. Click Palette
- Setting to choose a palette and save your option by clicking the screen area.
mage Mode
Image Mode Introduction
Four image modes are available.
- Infrared : infrared image.
- Visible : visible image.
- PIP : infrared image superimposed at the center of the visible image
- Thermal Fusion: an image fused to a certain scale between an infrared image and a visible image Note: For better dual-light image effects, when in PIP or thermal fusion modes, you need to set the actual distance, that is, the approximate distance from the thermal camera to the object. If the preset registration parameters cannot meet the requirements, you can also manually perform fusion registration in the settings.
Setting Steps
- In the observation interface, press OK shortly to enter the main menu, and select image mode through the navigation button. Then press OK again to enter the secondary menu, there different image mode can be selected by shifting left or right on the navigation button. Save your option by pressing enter button.
- In the observation interface, click any place on the screen to enter the main menu. Click image mode and select the desired image mode, and then click on the screen area. The option is saved.
Non-uniformity Correction
Non-uniformity Correction Introduction
- Non-uniformity correction is used to compensate for non-uniformity of detector pixels or non-uniformity caused by other optical interference. When there are more noise in the image, non-uniformity correction is needed, which is common when the ambient temperature changes rapidly.
Non-uniformity Correction Operations
In the imaging interface , long press the back button or the gallery button to perform non-uniformity correction.
Contrast Adjustment
- In the observation interface, the contrast of the infrared image can by adjusted by sliding up and down the arrow button on the temperature scale on the right side of the screen. The default temperature scale is 24.2℃-34.6℃ in the auto mode.
After the lower limit is changed to 27.7℃ manually:
- Click the A button in the bottom right corner to return to the auto contrast mode, the upper limit and lower limit will adjust automatically according to the Min temperature and Max temperature on the image, and the image color will distribute based on the color of the temperature scale.
Digital Zoom
In observation interface, press the navigation button to perform Max.
8×digital zoom.
Note: this function is only enabled under infrared mode or visible mode.
Other Settings
Other settings include date and time, unit, language and other items.
- In the observation interface, short press the OK button to enter the main menu, and select Settings via the navigation button, then press the OK button to enter other settings.
- In the observation interface, tap anywhere on the screen to enter the main menu, and tap Settings to enter other settings
Temperature Measurement Mode.
-u20~120℃:the device supports thermal imaging between -20℃ and 120℃.
Above/Below Temperature Alarm
- High temperature alarm switch: click to enable or disable the function of high temperature alarm. Temperature setting for high temperature alarm: click on the pop-up keyboard and set the alarm temperature, 120℃ by default.
- Low temperature alarm switch: click to enable or disable the function of low temperature alarm. Function.
Temperature setting for low temperature alarm: click on the pop-up keyboard and set the alarm temperature, 0℃ by default.\
- Auto Alarm Snapshot: click to enable or disable, disable by default. Auto capture image during alarm.
- Time Interval: the time interval of alarm snapshot is 10s by default, click to perform custom setup.
- Number of Snapshot: 100 by default, click to perform custom setup
Wi-Fi Settings
Click and enter Wi-Fi settings interface.
- Hotspot Switch: turn on hotspot and set the network name and password, then click OK.
- The specialized app is needed while this function is enabled. You need connect the hotspot manually after turning hotspot on, and you can transmit the saved pictures or videos to mobile device to perform secondary analysis.
- Turn off hotspot when it is not used, or else the power consumption will be faster.
Photo Settings
- Auto save of manual snapshot switch: click to enable or disable the function of auto save of manual snapshot, disabled by default.
- Time-lapse snapshot: click to enable or disable the function of time-lapse snapshot.
- Time interval of time-lapse snapshot: 60s by default, click to perform custom setup.
- Number of time-lapse snapshots: 100 by default, click to perform custom settings.
- Index mode: the file name is Time_IndexDC/IR.jpg by default if the index mode is enabled; the file name is Time DC/IR.jpg if the index mode is disabled.
Dual-spectrum Alignment
- Dual-spectrum Fusion Alignment
- This function can be used to manually register infrared and visible images. First select coarse tuning and fine tuning, and then perform image alignment through navigation buttons. After finished, click OK or enter button to save the settings. (You can drag on the touch screen with one finger to achieve fusion alignment in dual-spectrum fusion mode).
Picture-in-picture Adjustment
- This function can be used to adjust the position of the picture-in-picture. First select coarse tuning and fine tuning, and then adjust the position of the picture-in-picture by the navigation buttons. When finished, click OK or enter button to save the settings. (You can move the PIP by dragging the picture with your one finger, and adjust the PIP size by dragging the picture edges).
Automatic Power-off
- 5Min: c lick to perform auto shut down after 5 minutes.
- 10Min: click to perform auto shut down after 10 minutes.
- 20Min: click to perform auto shut down after 20 minutes.
- Off: Click to disable the function of auto shutdown, this function is disabled by default
System Settings
-
Click to check model, version, SD card capacity and SD card remaining capacity.
-
Date & Time
Click to perform date and time settings. The year can be self-defined from the Year 2020 to the Year 2037, the month, day, hour and min can be changed. -
Unit
-
Temperature Unit: switch between Celsius, Fahrenheit and Kelvin.
-
Distance Unit: switch between meter and foot.
Screen Brightness
- High : click to set the screen brightness as high brightness.
- Medium : click to set the screen brightness as medium brightness, medium brightness by default.
- Low : click to set the screen brightness as low brightness.
Formatting the SD Card
Click and then press OK to format the SD card as FAT32.
USB Mode
There are two options for data transmission: U disk and USB camera.
- U disk mode: the saved images and videos can be read and analyzed when the camera is connected with other devices via a data cable in this mode.
- USB camera: the real-time image view and spot/line/region analysis can be achieved on the PC when the camera is connected with the PC via a data cable in this mode.
Restore Factory Settings
Click and then press OK, the camera will power off automatically a few seconds
later, the settings will restore to the factory default state after reboot.
Software Update
Download the latest software to Update file in SD memory, click Update from SD
memory to update. The camera will power off automatically, the software will
update to the latest version after reboot.
Structural Drawings
Cleaning Thermal Camera
Cleaning Camera Housing, Cables and Other Items
Camera Housing, Cables and Other Items
Liquids| One of the following liquids can be used. 1.Warm water
2.A Weak detergent solution
Cleaning Tools| A soft cloth
Cleaning Procedure| Please follow this procedure: 1.Soak a soft cloth in the
liquid.
2.Twist the cloth to remove excess liquid. 3.Clean the camera parts with the cloth.
CAUTION
- Do not apply solvents or similar liquids to the camera, the cables, or other items. This can cause damage.
Cleaning Infrared Lens
Cleaning Infrared Lens
Liquids| One of the following liquids can be used. 1.Commercial lens cleaning
liquid with more than 30% is opropyl alcohol. 2. 96% ethyl alcohol(C2H5OH).
Cleaning Tools| cotton wool
**** Cleaning Procedure|
- Please follow this procedure:Soak the cotton wool in the liquid.
- Twist the cotton wool to remove the excess liquid.
-
- Clean the lens one time only and discard the cotton wool.
CAUTION
Do not clean the infrared lens too vigorously. This can damage the anti- reflective coating.
Worth comes from Service
- 24h Hotline:
- 400-998-3088
Technical Support
- Hotline:
- 400-883-0800
- Customized Services
Uncooled Handheld Thermal Camera for Gas Leak Detection statement
Information to user.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Labeling requirements
- This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
§15.105 Information to the user.
For a Class A digital device or peripheral, the instructions furnished the
user shall include the following or similar statement, placed in a prominent
location in the text of the manual:
Note
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
Body-worn Operation
- This device was tested for typical body-support operations. To comply with RF exposure requirements, a minimum separation distance of 0.0cm must be maintained between the user’s body and the handset, including the antenna. Third-party belt-clips, holsters, and similar accessories used by this device should not contain any metallic components. Body accessories that do not meet these requirements may not comply with RF exposure requirements and should be avoided. Use only the supplied or an approved antenna.