ax-s AX290KA Standalone Access Control Keypad User Manual

June 15, 2024
ax-s

ACCESS CONTROL
AX290KA USER MANUALax s AX290KA Standalone Access Control
Keypadax s AX290KA Standalone Access Control
Keypad - Symbol41100294
v1.0.0

System Components

ax s AX290KA Standalone Access Control Keypad - Keypad
Reader| ax s AX290KA Standalone
Access Control Keypad - Hex Key
---|---
Proximity and Keypad Reader| 1x Hex Key
4 x Plastic wall plug
4 x Countersunk screws
1x Diode and 1 x Capacitor

Installation

ax s AX290KA Standalone Access Control Keypad - Installation
1| Release hex screw from the bottom of the keypad
---|---
ax s AX290KA Standalone Access Control Keypad - Installation
2| (Side View)
Push the keypad up to release from mount plate
ax s AX290KA Standalone Access Control Keypad - Installation
3| Thread system cable through the cable entry hole then make the system connections (as per the wiring diagram), mount the bracket to the surface and slide the keypad to the mountplate, re- fit the hex screw to secure into position.

Note: if using more than one keypad, ensure that the keypads are mounted a minimum 185cm apart

Wiring Example

ax s AX290KA Standalone Access Control Keypad - Wiring
Example

Advanced Programming Guide

How to set-up Access Pin Number and Tags

Step Number Action Keypad Indication
1 Enter Programming Long Tone
2 Enter a starting location number Double Tone
3 Enter a 4 digit pin (1234 not be used) Long Tone
4 Present the tags Tone
5 To end programming

How to set the length of the master Pin.

Step Number Action Keypad Indication
1 Enter Programming Long Tone
2
3 Long Tone
4 Enter number of digital 2-6 Long Tone
5 To end programming

Note: When the length of the master code is changed, all existing Pin and Tag will be deleted.
How to set-up Access Pin Number

Step Number Action Keypad Indication
1 Enter Programming Long Tone
2
3 Long Tone
4 Enter a starting location number Double Tone
5 Enter a 4 digit pin (1234 not be used) Long Tone
6 To end programming

How to set-up Tags in batches (Normal EM125KHz cards)

Step Number Action Keypad Indication
1 Enter Programming Long Tone
2
3 Long Tone
4 Enter a starting unused location number * Long Tone
5 Enter 3-digit number as quantity of tags to be registered Tone
6 Present all the tags one by one Tone
7 All tags will be auto register

To end programming|

*Each tag will use up a location number (the locations must)

How to set-up Tags in batches (Tags in consecutive numbers)

Step Number Action Keypad Indication
1 Enter Programming Long Tone
2
3 Long Tone
4 Enter an unused location number* Long Tone
5 Enter 3-digit number as quantity of tags to be registered Tone
6 Present the tag with the lowest serial number Tone
7 All other batch tags will auto register

To end programming|

*Each tag will use up a location number
Deleting Access Pin or Tag

Step Number Action Keypad Indication
1 Enter Programming Long Tone
2 Enter the location number of tag/pin
3 To delete
4 To end programming

Changing Programming Pin

Step Number Action Keypad Indication
1 Enter Programming Long Tone
2
3 Enter new 4 digit programming pin
4 Re-enter new 4 digit programming pin Long Tone
5 To end programming

Note:  To access keypad’s programming mode, the 4 digit programming code is entered in twice
If forgot the password, turn off the power, press and hold button , connect powert again until
Bi-sound is heard, the password will be reset to default one 1234
Clear all Pin and Tag Data Step Number

Step Number Action Keypad Indication
1 Enter Programming Long Tone
2
3 Long Tone
4 To end programming

Default to Factory Settings

Step Number Action Keypad Indication
1 Enter Programming Long Tone
2
3 Long Tone
4 To end programming

Lock 1 Output Operating Time

Step Number Action Keypad Indication
1 Enter Programming Long Tone
2
3 Enter number of seconds 00 or 1-99 Long Tone
4 To end programming

I.e.lf setting lock-time as 00 mean, Swipe card or input password once open the door, swipe card or input password again close the door.
Enable & Disable backlight

Step Number Action Keypad Indication
1 Enter Programming Long Tone
2
3 To enable Long Tone
4 To end programming

Default: Enabled the backlight
Enable ‘Buzzer’ Function

Step Number Action Keypad Indication
1 Enter Programming Long Tone
2
3 To enable
4 To end programming

*Once the “Buzzer” function is disabled, keypad operation becomes mute.
Enable ‘Tamper Alarm’ facility

Step Number Action Keypad Indication
1 Enter Programming Long Tone
2
3 To enable Long Tone
4 To end programming

Tamper alarm activates the keypad’s internal buzzer and ‘door bell’ output if the light sensor is exposed.
Access Pin Number for Lock 2 Output

Step Number Action Keypad Indication
1 Enter Programming Long Tone
2
3 Long Tone
4 Enter an unused location number Double Tone
5 Enter a 4 digit pin (1234 should not be used) Long Tone
6 To end programming

Deleting Access Pin for Lock 2

Step Number Action Keypad Indication
1 Enter Programming Long Tone
2
3 Enter the location number of pin
4 To delete
5 To end programming

Lock Output Operating Time for Lock 2 Output

Step Number Action Keypad Indication
1 Enter Programming Long Tone
2
3 Enter number of seconds 00 or 01-99 Long Tone
4 To end programming

I.e.lf setting lock-time as 00 mean, Swipe card or input password once open the door, swipe card or input password again close the door.

User Guide

To release Lock 1

ax s AX290KA Standalone Access Control Keypad - Relase
Lock

Technical Specification

DC input 12 – 24volts
AC input 12 – 24volts
Standby current 80 mA
Operating current (without lock) 110 mA
Working temperature -20c to +50c
Reader frequency 125KHz
IP rating 65
Dimension 120 x 76 x 28mm

www.ax-s.co.uk