WTM W1 Electron Microscope User Manual
- June 15, 2024
- WTM
Table of Contents
Electron Microscope
WTM-W1-A User Instruction Manual
Please read this manual in detail !
Careful reading experience is better!
Please keep the user instruction manual properly!
Product Overview
Please read this manual carefully before using.
Do not use the microscope until you know the method.
Use Instructions
- Please read this instruction manual carefully, and use it correctly.
- Pay attention to protect the lens part. Close the lens lid aft using to avoid entering dust or strange objects.
- The microscope can be used in hand or inserted as a desktop, with attention to avoid damage to the components.
- When placing items, place them directly below the center of the lens as much as possible. Avoid not seeing objects clearly and bringing about a bad experience.
Instructions for Using the Microscope Installation
Microscopy Composition
Using Environment
| Please be at-10℃~45℃, Use under the environment
---|---
| Please avoid the dust from entering Microscope lens and interior
| Please avoid the microscope being wet with water, drinks, corrosive lamp
liquid
| Please avoid microscope scopy Impact and violent shaking
| Please avoid keeping the microscope close to the heat source, open flame,
flammable and explosive
gases (liquid)
At low temperatures, the available capacity of the battery decreases to varying degrees.
Charging Instructions
- When the microscope unit power is low, the power indicator light blue light flash.
- The red light is always on when charging, and the indicator light goes off when filling it up.
| You can use a daily mobile phone charger, computer, and charger to charge the microscope.
---|---
| The charging time should not exceed 12 hours to avoid affecting the battery life. - During the charging process, if the microscope shell and the battery are slightly heated, please rest assured to use the normal phenomenon.
Storage Environment
- Store it in a cool and dry place for daily use to avoid direct sunlight.
- Avoid storing the microscope in a place with the risk of falling, which may cause the deviation of the microscope lens inside or the damage to other components, and other irreparable damage problems.
Microscope Opening and Use
Before using the microscope, make sure your hands are secured, or use it on the desktop.
The Microscope is On and Off
- Press the boot button on the side for 3 seconds, the small light on the USB interface or the bottom light is on, It means that the microscope is already turned on. Press and hold the boot button on the side for 3 seconds, USB, the small light on the interface side is off or the bottom light is off, which means that the microscope has been off. (Note: the microscope monomer is closed, suspended after use, do not forget to cover the lens cover.)
Microscopic Magnification Regulation
| Counter-Clockwise
Rotation: multiple magnification| | Clockwise Rotation: multiple reduction
---|---|---|---
(Note: In case of any other problems, the reset hole will restore the factory setting. At the same distance, the rotating zoom cylinder has two magniations. To adjust more multiples, it can be adjusted up and down through the microscope base bracket.)
Accessories and Tools
The APP Use Guide
Use on Android / IOS Devices:
- Scan the QR code, click download and install.
Software to download the QR code
-
The mobile terminal is the IOS system, and you can search for ” Uni Lab” at APP Store for download
Turn On the Device
Long press the power button for 3s, and the blue light flashes under the button after turning on, indicating that the app has not been connected yet. -
Connect the Microscope to the Android / IOS Device
(1) Opens the Uni Lab APP, click WiFi, jump to the connection page of the Android / IOS device, select the corresponding WiFi name of the product “WTM-1-XXXXXX” (hotspot without encryption)
(2) Clicks on and connects to the hotspot. If the connection confirmation prompt appears, please click “Keep Connected”(Android version) / click “OK”
(3) After the connection is successful the microscope blue lights on, proving that the microscope has successfully connected to yourdevice. Return to the APP to use it only.
Note: Please open the phone / tablet location permission when the APP is connected to the microscope.
Introduction and Use of the APP Interface
Open the APP, and follow the indicated operation steps. (Select the content in
the red box)
- APP, Reading Interface
Because of the mobile phone model version is different, the pictures are for reference only
Take a photo: Select a photo mode
Recording: Select the recording mode
Zoom in: Click to zoom in on the screen (use when the screen is too small)
Zoom Out: Click to zoom out the screen (used when the screen is too large, the default is the smallest each time it is opened)
The Computer Interface Introduction and Use
- When the computer operating system is Windows 10 or higher, search in the Microsoft Store Download “Uni Lab”, (as shown in” “); when the computer system is Mac, please use the computer to Watch with a camera (as shown in “ “). The device camera button cannot be used, it can only be realized through software Photo recording function;
- Windows 7 and Windows XP system, please download the software from the following website”http://www.weetool.net”
(1) Log in the website and download UniLab software.
(2) The opens the software and selects the device.
(3) Open the software and select the device. (Mac)
Troubleshoot the Microscope
Problem Phenomenon | Cause | Processing Method |
---|---|---|
Heat up during the charging process | During the charging process, the current |
is relatively large, and the lithium battery heats up, which is a normal
phenomenon.| Normal status
The APP is not unconnected| 1. The is too far away from
2. The device without power
3. Equipment failure| 1. Close repeated connection L.z
2. To charge the device using c.
3. APP and the device are off, restart before use
The APP was suddenly disconnected| 1. The is too far away from ,-.,-,
2. The device without power
3. Equipment failure| 1. Close repeated connection
2. To charge the device using
3. APP and the device are off, restart before use
The device cannot be charged| 1. Charging interface is not firmly plugged in
2. No power access to
3. Device fault| 1. Replug interface
2. Power on
The lens shows a blurred image| The ambient temperature changes dramatically,
causing the lens to fog| Wait for the temperature balance, a period of fog
disappeared before use
The product cannot be turned down or the button fail| System halted| Please
plug in the power supply for reset and restart
Note: APP withdrawal is normal
Microscopy Overall Parameters
Project | Parameter |
---|---|
Product Magnification Ratio | 50X-lOOOX |
Lens Structure | 2G+IR |
Angle of Field | 16° ((depending on the lens) |
LED Quantity | 8 SMD 3528 bright white lights (brightness adjustable) |
Focus Mode and Focus Range | Manual adjustment, 0 to 40 mm |
Imaging Distance | 3mm to Infinity |
Sensor Size | 1/4″ |
Noise-signal Ratio | 37db |
Sensitivity | 4300mV/lux-sec |
Video Recording Format | AVI |
Video Resolution | 1920*1080 |
Picture Format | JPG |
Picture Size | 1920*1080 |
Working Range | 0-10m (Open scene, Sheltered scene will affect working range) |
Working Hours | ≥2h |
Power Supply Mode | 700mAh |
Charging Requirements | DC-5V-1A |
Charging Time l | 1.5h |
Working Current | ~260mA |
Sing e Machine Size | 125x32x32mm |
Product Color | Blue (subject to physical objects) |
The WiFi Workin gEnvironment | Android 4.0 and above systems,ios8.0 and above |
systems
WiFi,W orking environment, Supporting Equipment Requirements| Support for
2.4Ghz {8201. lb Ig/ n) wireless data transmission equipment
The USB Workin gEnvironment| Windos xp, win 7,win 8.1, and win10 (32,64-bit)
provide support for Mac
Working Temperature| oºC – 40ºC
Storage Temperature:| 20ºC – 60ºC
Working Humidity:| 30-60%RH
Electron Microscope
Product name: Electron Microscope | Input parameter: DCSV = |
---|---|
Product size: 125x95x55mm | Operating temperature: – 0°C-45°C |
Net weight: about 0.29kg | Wireless connection: Wi-FilEEE802.l |
Power supply mode: 700mAh | Certification information: CE FCC RoHS |
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>